Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Polymers (Basel) ; 14(12)2022 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-35745882

RESUMEN

The development of anti-corrosion polymeric coatings has grown exponentially in the fields of material science, chemistry, engineering, and nanotechnology during the last century and has prompted the evolution of efficient characterization techniques. Nowadays, polymeric coatings represent a well-established protection system that provides a barrier between a metallic substrate and the environment. However, the increase in complexity and functionality of these coatings requires high-precision techniques capable of predicting failures and providing smart protection. This review summarizes the state of the art for the main electrochemical techniques, emphasizing devices that track the anti-corrosion properties of polymeric coatings from the macroscale to the nanoscale. An overview of the advances in accelerated corrosion testing and the electrochemical characterization of coatings is explored, including insights into their advantages and limitations. In addition, the challenges and potential applications of the theoretical approaches are summarized based on current knowledge. Finally, this work provides the reader with the trends and challenges of designing future technologies and models capable of tracking corrosion and predicting failures.

2.
Mater Sci Eng C Mater Biol Appl ; 116: 111149, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32806280

RESUMEN

Organic-inorganic hybrid coatings deposited on different types of metallic alloys have shown outstanding anticorrosive performance. The incorporation of osteoconductive additives such as hydroxyapatite (HA) and ß-tricalcium phosphate (ß-TCP) into organic-inorganic hybrid coatings is promising to improve the osseointegration and corrosion resistance of Ti6Al4V alloys, which are the most widely used metallic orthopedic and dental implant materials today. Therefore, this study evaluated the capability of poly(methyl methacrylate) (PMMA)-TiO2 and PMMA-ZrO2 hybrid coatings modified with HA and ß-TCP to act as bioactive and corrosion protection coatings for Ti6Al4V alloys. In terms of cell growth and mineralization, osteoblast viability, Ca+2 deposition and alkaline phosphatase assays revealed a significant improvement for the HA and ß-TCP modified coatings, compared to the bare alloy. This can be explained by an increase in nanoscale roughness and associated higher surface free energy, which lead to enhanced protein adsorption to promote osteoblast attachment and functions on the coatings. The effect of HA and ß-TCP additives on the anticorrosive efficiency was studied by electrochemical impedance spectroscopy (EIS) in a simulated body fluid (SBF) solution. The coatings presented a low-frequency impedance modulus of up to 430 GΩ cm2, 5 decades higher than the bare Ti6Al4V alloy. These findings provide clear evidence of the beneficial role of HA and ß-TCP modified hybrid coatings, improving both the biocompatibility and corrosion resistance of the Ti6Al4V alloy.


Asunto(s)
Materiales Biocompatibles Revestidos , Durapatita , Polimetil Metacrilato , Aleaciones/farmacología , Fosfatos de Calcio , Materiales Biocompatibles Revestidos/farmacología , Corrosión , Ensayo de Materiales , Propiedades de Superficie , Titanio
3.
Mater Sci Eng C Mater Biol Appl ; 110: 110713, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32204025

RESUMEN

Ti6Al4V is the mostly applied metallic alloy for orthopedic and dental implants, however, its lack of osseointegration and poor long-term corrosion resistance often leads to a secondary surgical intervention, recovery delay and toxicity to the surrounding tissue. As a potential solution of these issues poly(methyl methacrylate)-silicon dioxide (PMMA-silica) coatings have been applied on a Ti6Al4V alloy to act simultaneously as an anticorrosive barrier and bioactive film. The nanocomposite, composed of PMMA covalently bonded to the silica phase through 3-(trimethoxysilyl)propyl methacrylate (MPTS), has been synthesized combining the sol-gel process with radical polymerization of methyl methacrylate. The 5 µm thick coatings deposited on Ti6Al4V have a smooth surface, are homogeneous, transparent, free of pores and cracks, and show a strong adhesion to the metallic substrate (11.6 MPa). Electrochemical impedance spectroscopy results proved an excellent anticorrosive performance of the coating, with an impedance modulus of 26 GΩ cm2 and long-term durability in simulated body fluid (SBF) solution. Moreover, after 21 days of immersion in SBF, the PMMA-silica coating presented apatite crystal deposits, which suggests in vivo bone bioactivity. This was confirmed by biological characterization showing enhanced osteoblast proliferation, explained by the increased surface free energy and protein adsorption. The obtained results suggest that PMMA-silica hybrids can act in a dual role as efficient anticorrosive and bioactive coating for Ti6Al4V alloys.


Asunto(s)
Materiales Biocompatibles Revestidos , Ensayo de Materiales , Nanocompuestos/química , Polimetil Metacrilato , Dióxido de Silicio , Titanio , Aleaciones , Línea Celular , Materiales Biocompatibles Revestidos/química , Materiales Biocompatibles Revestidos/farmacología , Corrosión , Humanos , Polimetil Metacrilato/química , Polimetil Metacrilato/farmacología , Dióxido de Silicio/química , Dióxido de Silicio/farmacología , Titanio/química , Titanio/farmacología
4.
ACS Appl Mater Interfaces ; 11(43): 40629-40641, 2019 Oct 30.
Artículo en Inglés | MEDLINE | ID: mdl-31589404

RESUMEN

In this work, structural and active corrosion inhibition effects induced by lithium ion addition in organic-inorganic coatings based on poly(methyl methacrylate) (PMMA)-silica sol-gel coatings have been investigated. The addition of increasing amounts of lithium carbonate (0, 500, 1000, and 2000 ppm), yielded homogeneous hybrid coatings with increased connectivity of nanometric silica cross-link nodes, covalently linked to the PMMA matrix, and improved adhesion to the aluminum substrate (AA7075). Electrochemical impedance spectroscopy (EIS), performed in 3.5% NaCl aqueous solution, showed that the improved structural properties of coatings with higher lithium loadings result in an increased corrosion resistance, with an impedance modulus up to 50 GΩ cm2, and revealed that the lithium induced self-healing ability significantly improves their durability. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) and X-ray photoelectron spectroscopy (XPS) suggest that the regeneration process occurs by means of lithium ions leaching from the adjacent coating toward the corrosion spot, which is restored by a protective layer of precipitated Li rich aluminum hydroxide species. An analogue mechanism has been proposed for artificially scratched coatings presenting an increase of the impedance modulus after salt spray test compared to the lithium free coating. These results evidence the active role of lithium ions in improving the passive barrier of the PMMA-silica coating and in providing through the self-restoring ability a significantly extended service life of AA7075 alloy exposed to saline environment.

5.
J Colloid Interface Sci ; 513: 617-628, 2018 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-29202281

RESUMEN

HYPOTHESIS: The fraction of the silica/siloxane phase is a crucial parameter, which determines the structure and thus the properties of epoxy-siloxane-silica hybrid coatings. A careful adjustment of the colloidal precursor formulation allows tuning the nanostructure towards a highly condensed and cross-linked hybrid nanocomposite, suitable as an efficient anticorrosive coating. EXPERIMENTS: Novel epoxy-siloxane-silica hybrids have been prepared through the curing reaction of poly(bisphenol A-co-epichlorohydrin) (DGEBA) with diethyltriamine (DETA) and (3-glycidoxypropyl)methyltriethoxysilane (GPTMS), followed by hydrolytic condensation of tetraethoxysilane (TEOS) and GPTMS. At a constant proportion of the organic phase, the effects of the varying molar proportions of siloxane (GPTMS) and silica (TEOS) on the film properties have been investigated. FINDINGS: A detailed structural analysis suggests for intermediate TEOS to GPTMS ratios a structure of highly condensed silica-siloxane domains covalently bonded to the embedding epoxy phase. The homogeneous distribution of the quasi-spherical sub-nonmetric silica-siloxane nodes is in agreement with low surface roughness (<5 nm), observed by atomic force microscopy. This dense nanostructure results in high thermal stability (>300 °C), strong adhesion to steel substrate and excellent barrier property in saline solution, with corrosion resistance in the GΩ cm2 range.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...