Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Am J Otolaryngol ; 45(4): 104294, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38657534

RESUMEN

PURPOSE: The number of cochlear implant (CI) surgeries is growing over time, with the risk of overloading CI centers in the post-surgical management. Telemedicine is a possible solution to address this phenomenon. Remote Check (RC) is an application that is specific for CI recipients monitoring. The aim of this study is to evaluate the feasibility of application, potential economic impact and patients' acceptance of RC. METHODS: The study is retrospective investigation, data on clinical, audiological features (from remote and on-site evaluation), and satisfaction surveys of 66 consecutive patients were collected; costs required for RC and for on-site evaluations were recorded as well. RESULTS: One hundred and ninety RC sessions were completed by the patients (2.88 sessions per patient). RC and on-site audiometry significantly correlated except for the 500 Hz frequency. Estimated costs for the Italian National Health System for RC review and on-site evaluations were 1.32€ and 3.49€ per minute, respectively. High satisfaction for RC was reached in 91 % of patients. CONCLUSION: RC revealed to be a reliable, cost-effective and well accepted tool in CI monitoring. This study preliminarily supports the hypothesis that RC could be a valid instrument to reduce CI management overload in the outpatient clinic.

2.
Audiol Res ; 14(2): 239-253, 2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-38525683

RESUMEN

The etiology of sensorineural hearing loss is heavily influenced by genetic mutations, with approximately 80% of cases attributed to genetic causes and only 20% to environmental factors. Over 100 non-syndromic deafness genes have been identified in humans thus far. In non-syndromic sensorineural hearing impairment, around 75-85% of cases follow an autosomal recessive inheritance pattern. In recent years, groundbreaking advancements in molecular gene therapy for inner-ear disorders have shown promising results. Experimental studies have demonstrated improvements in hearing following a single local injection of adeno-associated virus-derived vectors carrying an additional normal gene or using ribozymes to modify the genome. These pioneering approaches have opened new possibilities for potential therapeutic interventions. Following the PRISMA criteria, we summarized the AAV gene therapy experiments showing hearing improvement in the preclinical phases of development in different animal models of DFNB deafness and the AAV gene therapy programs currently in clinical phases targeting autosomal recessive non syndromic hearing loss. A total of 17 preclinical studies and 3 clinical studies were found and listed. Despite the hurdles, there have been significant breakthroughs in the path of HL gene therapy, holding great potential for providing patients with novel and effective treatment.

3.
Audiol Res ; 14(2): 227-238, 2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-38525682

RESUMEN

OBJECTIVES: The objectives were to present the real-time estimated values of cochlear implant (CI) electrode insertion speed (IS) during intraoperative sessions using the Cochlear Nucleus SmartNav System to assess whether this measure affected CI outcomes and to determine whether real-time feedback assists expert surgeons in achieving slow insertion. METHODS: The IS was measured in 52 consecutive patients (65 implanted ears) using the CI632 electrode. The IS values were analyzed in relation to procedure repetition over time, NRT ratio, and CI audiological outcomes. RESULTS: The average IS was 0.64 mm/s (SD = 0.24); minimum and maximum values were 0.23 and 1.24 mm/s, respectively. The IS significantly decreased with each array insertion by the operator (p = 0.006), and the mean decreased by 24% between the first and last third of procedures; however, this reduction fell within the error range of SmartNav for IS (+/-0.48 mm/s). No correlation was found between IS and the NRT ratio (p = 0.51), pure-tone audiometry (PTA) at CI activation (p = 0.506), and PTA (p = 0.94) or word recognition score (p = 0.231) at last evaluation. CONCLUSIONS: The estimated IS reported by SmartNav did not result in a clinically significant reduction in insertion speed or an improvement in CI hearing outcomes. Real-time feedback of IS could potentially be used for training, but its effectiveness requires confirmation through additional studies and more accurate tools. Implementation of IS assessment in clinical practice will enable comparisons between measurement techniques and between manual and robot-assisted insertions. This will help define the optimal IS range to achieve better cochlear implant (CI) outcomes.

4.
Am J Otolaryngol ; 45(2): 104124, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38035465

RESUMEN

PURPOSE: Evaluate the hearing outcomes of bilateral deaf children implanted simultaneously and define the most appropriate timing for surgery. MATERIALS AND METHODS: Audiological CI results were retrieved in both the short-term and long-term period and compared by stratifying the patients into different subcohorts according to their age at surgery. Additional data collected were age at implant activation, etiology and timing of onset of deafness, presence of psychomotor delay. RESULTS: fifty-six bilaterally implanted children were included. The short-term outcomes differed significantly when comparing groups of different ages at implantation: younger patients achieved better aided pure tone audiometry results. Considering long-term follow-up, a significant correlation was identified between an early age at implantation and the hearing outcome at ages 2 to 5 years. Perceptive levels were better at 4 years of age in the younger group. No significant differences were found between children implanted at before 12 months and between 12 and 16 months of age. CONCLUSIONS: The results of the analyzed follow-up data support the hypothesis that children implanted at before 24 months are expected to have better hearing performances. Nevertheless, these results are referred to a widely heterogeneous group of patients and the duration of auditory deprivation should be considered.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Sordera , Percepción del Habla , Niño , Humanos , Sordera/cirugía , Implantación Coclear/métodos , Audiometría de Tonos Puros , Factores de Edad
5.
Audiol Res ; 13(4): 627-635, 2023 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-37622930

RESUMEN

(1) Background: Several types of hearing aids are available for the rehabilitation of vestibular-schwannoma (VS)-related hearing loss. There is a lack of recently published papers regarding this theme. The aim of the present work is to organize current knowledge. (2) Methods: A review of the literature regarding the topics "vestibular schwannoma", "hearing loss", and "hearing aid" was performed. Nineteen studies were thus considered. (3) Results: Conventional hearing aids, contralateral routing of signal (CROS) aids, bone anchored hearing aids (BAHA), and others are available options for hearing rehabilitation in VS patients. The speech discrimination score (SDS) is considered the best measure to assess candidacy for rehabilitation with hearing aids. The best hearing rehabilitative conditions in VS patients when using conventional hearing aid devices are a mild-moderate hearing loss degree with good word recognition (more than 50% SDS). CROS-Aid and BAHA are reported to be beneficial. CROS-Aid expands on the area of receiving hearing. BAHA aids use direct bone-conduction stimulation. Unfortunately, there are no available studies focused specifically on VS patients that compare CROS and BAHA technologies. (4) Conclusions: Hearing aids, CROS, and BAHA are viable options for rehabilitating hearing impairment in VS, but require an accurate case-by-case audiological evaluation for rehabilitating hearing impairment in VS. Further studies are needed to prove if what is currently known about similar hearing illnesses can be confirmed, particularly in the case of VS.

6.
Acta Otorhinolaryngol Ital ; 43(3): 221-226, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37204847

RESUMEN

Objective: To assess the hearing benefit with a unilateral bone conduction hearing aid in a cohort of children with unilateral aural atresia. Methods: Cross-sectional case series pilot study involving 7 children (median age: 10 years, range 6-11). All patients underwent pure-tone, speech, aided sound field and aided speech audiometry and Simplified Italian Matrix Test (SIMT) with and without bone conduction hearing aid (Baha 5® CochlearTM). Cognitive abilities were assessed in 5 patients. Results: The mean air conduction pure-tone average (PTA) of the atretic ear was 63.2 ± 6.9 dB, while the bone conduction PTA was 12.6 ± 4.7 dB. Speech discrimination score of the atretic ear was 88.6 ± 3.8 dB, while with the hearing aid it was 52.8 ± 1.9 dB. In the contralateral ear, there was no significant air-bone gap, and PTAs for air and bone conduction thresholds were within normal range (PTA ≤ 25 dB). The mean aided air conduction hearing threshold was 26.2 ± 7.97. Mean speech recognition threshold without the hearing aid was -5.1 ± 1.9 dB, and -6.0 ± 1.7 dB with the hearing aid tested with the SIMT. The mean score of the cognitive test was 46.8 ± 42.8. Conclusions: These preliminary findings should encourage clinicians in proposing a unilateral bone conduction hearing aid in children with unilateral atresia.


Asunto(s)
Audífonos , Percepción del Habla , Humanos , Niño , Conducción Ósea , Estudios Transversales , Proyectos Piloto , Oído/anomalías , Pérdida Auditiva Conductiva , Resultado del Tratamiento
8.
Front Pediatr ; 11: 1027045, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36923273

RESUMEN

About 20% of children with congenital hearing loss present malformations of the inner ear. In the past few years much has been understood about the morphology and function of the anterior part of the labyrinth, since hearing loss may have a dramatic effect on the overall development of a child. Nowadays, for most of them, a chance for hearing rehabilitation is available, making hearing loss a treatable condition. The anomalies range from the lack of development of the whole inner ear to specific anomalies of isolated structures. Despite the frequent concomitant involvement of the posterior part of the labyrinth, this part of the inner ear is frequently neglected while discussing its morphology and dysfunction. Even though vestibular and balance function/dysfunction may have a significant impact on the global development of children, very little is known about these specific disorders in patients with inner ear malformations. The aim of this review is to summarize the available literature about vestibular anomalies and dysfunctions in children with inner ear malformations, discussing what is currently known about the topic.

9.
Am J Audiol ; 32(1): 52-58, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36538514

RESUMEN

PURPOSE: Unilateral cochlear implants (CIs) can restore binaural hearing in single-sided deafness (SSD). Direct stimulation of the CI can be obtained via the Bluetooth connection of a device to the CI, thus excluding the typical-hearing ear. This study aims to investigate the use of CI connectivity features as a rehabilitative strategy in a small cohort of children affected by SSD. METHOD: A newly developed training protocol was presented to children with SSD who have less than 2 years of experience with CI. We developed a user-friendly and short-term (six sessions within 20 days) training protocol for speech perception that patients themselves can manage independently at home using CI connectivity systems. Children were telematically tested before and after the training by trained speech and language therapists. RESULTS: Four patients met the inclusion criteria. They all showed better results in the final online assessment, when compared with the initial one. CONCLUSIONS: To our knowledge, this is the first clinical focus article presenting an auditory training protocol for SSD patients with CI using the Bluetooth connectivity systems for teletherapy. The results, although preliminary, support the efficacy of this rehabilitative strategy. Further research is needed to support our findings.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Sordera , Pérdida Auditiva Unilateral , Percepción del Habla , Humanos , Niño , Percepción del Habla/fisiología , Sordera/rehabilitación , Pérdida Auditiva Unilateral/rehabilitación , Ruido , Implantación Coclear/métodos
10.
J Am Acad Audiol ; 33(2): 105-114, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-35577055

RESUMEN

BACKGROUND: Impedance is a basic parameter registered at any cochlear implant (CI) fitting section. It is useful in monitoring electrode functioning and the status of the surrounding anatomical structures. PURPOSE: The main aim of this study is to evaluate the 5-year impedance-value trend in patients affected by congenital genetically determined profound hearing loss implanted with Cochlear Nucleus devices. RESEARCH DESIGN: Observational, retrospective, monocentric study. STUDY SAMPLE: Twenty-seven consecutive patients (9 females: 12.0 ± 7.6 years old; range: 4.2-40.4) with genetic diagnosis of GJB2 mutation causing congenital profound hearing loss who underwent cochlear implantation from 2010 to 2020 with good auditory benefit. INTERVENTION: Impedance values of the CIs were obtained from the CIs' programming software that registers those parameters for each follow-up section of each patient. DATA COLLECTION AND ANALYSIS: Impedance values were measured over time (activation, 6, 12, 24, and 60 months after cochlear implantation), for each of the 22 electrodes, in common ground, monopolar 1, monopolar 2, and monopolar 1 + 2 stimulation modes. RESULTS: A significant variation was found between CI activation and 6-month follow-up. This difference was found for each of the 22 electrodes. Electrodes 1 to 4 showed higher impedance values compared with all other electrodes in each time interval. Repeated-measures analysis of variance ruled out significant variations in impedance values from 6-month to 5-year follow-up. CONCLUSIONS: Impedance values were extremely stable after activation, at least for the first 5 years. In these cases, even minimal impedance variations should be carefully evaluated for their possible implications on hearing performance.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Pérdida Auditiva , Adolescente , Adulto , Niño , Preescolar , Impedancia Eléctrica , Femenino , Pérdida Auditiva/rehabilitación , Humanos , Estudios Retrospectivos , Adulto Joven
11.
Otolaryngol Head Neck Surg ; 166(2): 217-218, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-33940979

RESUMEN

Pediatric hearing loss early diagnosis and treatment have been limited by the current restrictions due to the coronavirus disease 2019 pandemic. The difficulty in accessing the multiple facilities required for the rehabilitative process is influencing the timing of each step of the process. Auditory hearing screening programs, etiological characterization, surgical timing, and speech therapies have all been limited in the past year. The current conditions have forced us to adopt different strategies to overcome the necessary social distancing prescriptions. Although their efficacy should be proved over time, some of these resources will be probably useful even in a nonpandemic future.


Asunto(s)
COVID-19 , Accesibilidad a los Servicios de Salud , Pérdida Auditiva/terapia , Niño , Implantes Cocleares , Pérdida Auditiva/diagnóstico , Pérdida Auditiva/rehabilitación , Humanos
13.
Otol Neurotol ; 43(1): 101-104, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-34699400

RESUMEN

OBJECTIVE: To investigate the prevalence-rate of oval window bulging in the common cavity and its association with bacterial meningitis. PATIENTS: CT and clinical files of 29 children with preliminary diagnosis of common cavity deformity were collected from 13 Italian centers. INTERVENTION: A retrospective case review study was conducted with a centralized evaluation of the temporal bone CT imaging was performed at Azienda Ospedale - Università Padova, Padova, Italy. MAIN OUTCOME MEASURE: Diagnosis of common cavity was reviewed; in addition, a fluid protrusion into the middle-ear cavity through the oval window at CT imaging was considered as oval window bulging. Its association with the history of bacterial meningitis was investigated. RESULTS: Common cavity deformity was confirmed in 14/29 children (mean-age 11.4 ±â€Š3.8; age-range 5-20; nine females) referred with this diagnosis. In 7/14 patients, the common cavity deformity was bilateral (i.e., 21 common cavities). Oval window bulging was found in 3/19 common cavities (concomitant middle-ear effusive otitis hampered the evaluation in two cases), while the internal acoustic meatus fundus was defective in 10/21 cases. History of bacterial meningitis was found in three children (21%) and two of them had oval window bulging at CT. In the case unrelated to oval window bulging, meningitis occurred late at the age of 12 during acute otitis contralateral to common cavity deformity (ipsilaterally to incomplete partition type 1). CONCLUSION: Patients harboring common cavity deformity have a high risk of meningitis in their first years of life. Oval window bulging seems to be associated with a higher risk of meningitis. This information might be important for appropriate surgical planning.


Asunto(s)
Meningitis Bacterianas , Tomografía Computarizada por Rayos X , Adolescente , Niño , Cóclea , Oído Medio , Femenino , Humanos , Meningitis Bacterianas/complicaciones , Meningitis Bacterianas/diagnóstico por imagen , Meningitis Bacterianas/epidemiología , Ventana Oval , Estudios Retrospectivos
14.
Audiol Res ; 11(4): 524-536, 2021 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-34698066

RESUMEN

Inner ear malformations are present in 20% of patients with sensorineural hearing loss. Although the first descriptions date to the 18th century, in recent years the knowledge about these conditions has experienced terrific improvement. Currently, most of these conditions have a rehabilitative option. Much less is known about the etiology of these anomalies. In particular, the evolution of genetics has provided new data about the possible relationship between inner ear malformations and genetic anomalies. In addition, in syndromic condition, the well-known presence of sensorineural hearing loss can now be attributed to the presence of an inner ear anomaly. In some cases, the presence of these abnormalities should be considered as a characteristic feature of the syndrome. The present paper aims to summarize the available knowledge about the possible relationships between inner ear malformations and genetic mutations.

15.
Int J Pediatr Otorhinolaryngol ; 149: 110876, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34385039

RESUMEN

BACKGROUND: Little is known regarding fitting parameters and receptive and expressive language development in cochlear-implanted children (CCI) with profound sensorineural hearing loss (SHL) who are diagnosed with Autism Spectrum Disorder (ASD). The aim of the study was to evaluate a group of ASD CCI users in order to describe their ASD clinical features and CCI outcomes; report on the average electrical charge requirements; and evaluate the possible correlations between electrical and psychophysical outcomes with ASD characteristics. MATERIALS AND METHODS: A multicentre observational study of 22 ASD children implanted in four cochlear implant (CI) centers. Data concerning profound SHL diagnosis, ASD diagnosis, CI timing and CI compliance were collected. Sound Field (SF) was assessed through repeated behavioural measurements. Categories of Auditory Perception (CAP) and Categories of Language (CL) were used to evaluate speech perception and language skills at short (≤2 yrs), medium (5 yrs) and long term (>10 yrs) follow-up. Fitting parameters such as comfortable thresholds, pulse-width (pw, µsec) and clinical units converted into units of charge/phase were collected. The diagnosis of ASD was acquired by the referral neuropsychiatric department and severity was assessed through the Diagnostic and Statistical Manual of Mental Disorders (DSM-V) and the Childhood Autism Rating Scale (CARS). RESULTS: At the final follow-up session the median SF threshold for CI outcomes was 30 dB HL (min 15 - max 60). CAP score was extremely variable: 45.5% showed no improvement over time and only 22% of children reached CAP scores of 5-7. CL 45.5% showed no improvement over time and score was 1-2 in the majority of ASD children (72.7%), while only 18.2% reached the highest level of language skills. There were no statistically significant differences at each follow-up between subjects with or without comorbidities. CAP and CL were inversely correlated with DSM-V A and B domains, corresponding to lower speech and language scores in children with more severe ASD symptoms, and maintained their correlation at mid and long follow-ups whilst controlling for age at CI. Electrical charge requirements did not correlate with SF or age at implant but did inversely correlate with ASD severity. With regards to CI compliance: only 13.6% children (3) with severe DSM-V A/B levels and CARS score were partial/intermittent users. CONCLUSION: The present study is a targeted contribution to the current literature to support clinical procedures for CI fitting and audiological follow-up in children with ASD. The findings indicate that the outcomes of CI use and the fitting procedures are both influenced by the severity of the ASD symptoms rather than the demographic variables or associated disorders.


Asunto(s)
Trastorno del Espectro Autista , Implantación Coclear , Implantes Cocleares , Sordera , Percepción del Habla , Trastorno del Espectro Autista/complicaciones , Trastorno del Espectro Autista/diagnóstico , Niño , Sordera/cirugía , Humanos
17.
Aging Clin Exp Res ; 33(5): 1157-1161, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33725340

RESUMEN

During COVID-19 pandemic, protective measures such as social distancing and face masks posed a challenge in daily communication, in this context the elderly are one of the most at risk categories as widely exposed to hearing loss. This article focuses on how the COVID-19 pandemic affected verbal communication, especially on those people that even in normal conditions present an increased difficulty in speech perception. Special attention has been paid to hearing aids and cochlear implant users, these devices indeed can be affected by a speech intelligibility reduction and could be uncomfortable if used together with face masks. Possible alternatives and solutions will be proposed to reduce the negative impacts of face coverings on communication, to enhance speech intelligibility and to manage wearability of hearing rehabilitation devices.


Asunto(s)
COVID-19 , Implantes Cocleares , Percepción del Habla , Anciano , Humanos , Pandemias , Distanciamiento Físico , SARS-CoV-2
19.
Laryngoscope ; 131(1): 179-185, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-31904878

RESUMEN

Two hundred and fifty years have passed since the birth of Ludwig van Beethoven, and the enigma about his hearing loss and overall health status seems to be not completely solved. However, the admission to the hospital of a 64-year-old woman in 2018 with symptoms extremely similar to those experienced by the great composer may add further evidence to a theory previously underestimated. The health issues of the modern patient were found to be due to chronic lead intoxication. The lead was released during daily cooking using a ceramic-coated frying pan with worn surface that poisoned her breakfast most probably for years. Abdominal pain, asthenia, and hearing loss affecting the high frequencies with a many impact on speech intelligibility tormented the patient, as they had Beethoven. An extensive review of the music and medical literature was performed, as well as re-examination of manuscripts, correspondence, and autopsy reports of the famous composer; and great similarities have been found. The soundness of the most-cited classical theories about Beethoven's hearing loss will be discussed. After close scrutiny of the theories, our analysis points toward a progressive sensorineural hearing loss due to lead intoxication as the most probable cause of not only Beethoven's hypoacusis but his overall health status as well. Laryngoscope, 131:179-185, 2021.


Asunto(s)
Personajes , Pérdida Auditiva Sensorineural/diagnóstico , Femenino , Alemania , Historia del Siglo XVIII , Historia del Siglo XIX , Humanos , Persona de Mediana Edad
20.
Audiol Neurootol ; 26(3): 157-163, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33352559

RESUMEN

INTRODUCTION: Non-syndromic hereditary hearing loss is characterized by extreme genetic heterogeneity. So far, more than 100 pathogenic or likely pathogenic variants in TMC1 gene have been reported in patients with autosomal recessive hearing loss (HL) DFNB7/11. The prevailing auditory phenotype of individuals with DFNB7/11 is congenital, profound, bilateral HL, but the functional outcome after cochlear implantation (CI) described in the literature is variable. The objective of this work is to evaluate the auditory outcome after CI in pediatric patients with DFNB7/11, born to non-consanguineous parents. METHODS: A retrospective analysis of genetic and audiological data of DFNB7/11 patients followed up in a single Italian otolaryngology clinic was performed. Cases with biallelic pathogenic variants in TMC1 were selected from the cohort of children with non-syndromic hearing loss who had undergone CI and had been molecularly characterized by multigene panel testing. All patients underwent extensive audiological assessment, and the auditory outcome after CI was evaluated. RESULTS: DFNB7/11 was diagnosed in a total of 3 patients from 2 non-consanguineous families; a novel disease-causing variant in TMC1 was detected [c.962G>A p.(Trp321*)]. All the affected children showed the typical DFNB7/11 phenotype characterized by prelingual, severe-to-profound HL. The patients showed an excellent functional outcome after CI; speech perception, nonverbal cognition, and speech performance were comparable to those of patients with DFNB1 deafness. DISCUSSION/CONCLUSION: Our results do not support the variable auditory outcome reported in the literature, which may be affected by several social and environmental factors and by the genetic background.


Asunto(s)
Implantación Coclear , Pérdida Auditiva Sensorineural/cirugía , Proteínas de la Membrana/genética , Niño , Preescolar , Femenino , Pérdida Auditiva Sensorineural/genética , Humanos , Fenotipo , Estudios Retrospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...