1.
Eur J Cardiovasc Nurs ; 22(8): 773-779, 2023 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-36346102

RESUMEN

AIMS: Implantable cardiac monitors (ICMs) can generate false-positive (FP) alerts. Although these devices have an extended programmability, there are no recommendations on their optimization to reduce not-relevant activations.We tested a strategic programming optimization guide based on the type of FP and investigated the safety and feasibility of the nurse-led insertion of ICMs with a long-sensing vector. METHODS AND RESULTS: Consecutive patients implanted by trained nurses with long-sensing vector ICM were enrolled in a 1-month observational stage (Phase A). Patients who had ≥10 FP episodes underwent ICM reprogramming based on the predefined guide and were followed for an additional month (Phase B). A total of 78 patients had successful ICM insertion by nurses with a mean R wave amplitude of 0.96 ± 0.43 mV and an 86% P wave visibility. Only one patient reported a significant device-related issue, and nurse-delivered ICM was generally well accepted by the patients. During Phase A, 11 patients (14%) generated most of FP (3,627/3,849; 94%) and underwent ICM reprogramming. In the following month (Phase B), five patients (45%) were free from FP and six (55%) transmitted 57 FP alerts (98% reduction compared with Phase A). The median number of FP per patient was significantly reduced after reprogramming [195 (interquartile range, 50-311) vs. one (0-10), P = 0.0002]. CONCLUSION: A strategic reprogramming of ICM in those patients with a high FP alert burden reduces the volume of erroneous activations with potential benefits for the remote monitoring service. No concerns were raised regarding nurse-led insertion of ICMs with a long-sensing vector.


Asunto(s)
Fibrilación Atrial , Electrocardiografía Ambulatoria , Humanos , Arritmias Cardíacas , Electrocardiografía , Electrocardiografía Ambulatoria/métodos , Rol de la Enfermera , Prótesis e Implantes , Estudios de Factibilidad
2.
Diagnostics (Basel) ; 12(4)2022 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-35454042

RESUMEN

No studies have investigated whether optimizing implantable cardiac monitors (ICM) programming can reduce false-positive (FP) alerts. We identified patients implanted with an ICM (BIOMONITOR III) who had more than 10 FP alerts in a 1-month retrospective period. Uniform adjustments of settings were performed based on the mechanism of FP triggers and assessed at 1 month. Eight patients (mean age 57.5 ± 23.2 years; 37% female) were enrolled. In 4 patients, FPs were caused by undersensing of low-amplitude premature ventricular contractions (PVCs). No further false bradycardia was observed with a more aggressive decay of the dynamic sensing threshold. Furthermore, false atrial fibrillation (AF) alerts decreased in 2 of 3 patients. Two patients had undersensing of R waves after high-amplitude PVCs; false bradycardia episodes disappeared or were significantly reduced by limiting the initial value of the sensing threshold. Finally, the presence of atrial ectopic activity or irregular sinus rhythm generated false alerts of AF in 2 patients that were reduced by increasing the R-R variability limit and the confirmation time. In conclusion, adjustments to nominal settings can reduce the number of FP episodes in ICM patients. More research is needed to provide practical recommendations and assess the value of extended ICM programmability.