Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
J Clin Med ; 13(7)2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-38610707

RESUMEN

Background/Objectives: There is a lack of reliable biomarkers for diagnosis of infection eradication prior to second-stage reimplantation in two-stage exchange arthroplasty for periprosthetic joint infections (PJIs). The aim of this study was to assess the diagnostic accuracy of rotational thromboelastometry (ROTEM) for persistent infection in two-stage exchange arthroplasties. Methods: A pilot, retrospective analysis was performed including 70 patients who underwent a two-stage exchange arthroplasty for PJI. They were categorized as patients without (n = 64) or patients with persistent infection (n = 6) prior to reimplantation. Definition of persistent infection prior to reimplantation was based on the 2018 ICM criteria. Conventional coagulation biomarkers and ROTEM parameters were compared between groups. Results: Higher FIBTEM MCF values were associated with persistent infection (odds ratio [OR], 1.30, 95% confidence interval [CI], 1.04-1.63; p = 0.020), and FIBTEM MCF had the highest diagnostic accuracy for persistent infection prior to second-stage reimplantation (AUC, 0.907; 95% CI, 0.812-1.000). A cut-off value ≥ 18 mm for FIBTEM MCF was found to have 100.0% sensitivity and 73.4% specificity for diagnosing persistent infection prior to second-stage reimplantation. Moreover, the diagnostic accuracy of FIBTEM MCF was higher than that of fibrinogen levels (p = 0.036) and D-dimer (p = 0.006). Conclusions: Our findings indicate that ROTEM parameters have the potential to identify persistent infections before reimplantation in two-stage exchange arthroplasties for PJI. Such coagulation biomarkers could provide guidance regarding the optimal timing for reimplantation. Further studies in larger populations are warranted to validate the diagnostic accuracy of ROTEM parameters for persistent PJI.

2.
Eur J Orthop Surg Traumatol ; 34(3): 1557-1562, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38280074

RESUMEN

PURPOSE: Glenoid tumors are extremely rare, and reconstruction remains very challenging. The aim of this study is to present the clinical and functional outcomes, of a new glenoid reconstruction method using 3-dimensional-printed implant. METHODS: Four patients with primary glenoid tumors underwent reconstruction using 3-dimensional-printed glenoid implant linked with reverse shoulder arthroplasty. We retrospectively reviewed the clinical and functional outcome, using MSTS and DASH score, as well as complications' rate. RESULTS: Wide excision was achieved in all patients. No local recurrence or distant metastasis was diagnosed at the follow-up period. The mean MSTS score was 80.5%, and DASH score was 15.2%. According to Hendersons' classification, there were no postoperative complications. CONCLUSION: The use of 3-dimensional-printed implants, can be a very reliable solution with satisfying clinical and functional outcomes for reconstruction, in patients with musculoskeletal malignancies of the glenoid. Level of evidence IV Treatment Study.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Neoplasias , Articulación del Hombro , Humanos , Estudios Retrospectivos , Escápula/diagnóstico por imagen , Escápula/cirugía , Neoplasias/etiología , Neoplasias/patología , Neoplasias/cirugía , Prótesis e Implantes , Impresión Tridimensional , Resultado del Tratamiento , Artroplastía de Reemplazo de Hombro/efectos adversos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía
3.
J Bone Joint Surg Am ; 105(24): 1980-1986, 2023 12 20.
Artículo en Inglés | MEDLINE | ID: mdl-37903295

RESUMEN

BACKGROUND: Periprosthetic joint infections (PJIs) are associated with altered hemostatic dynamics; therefore, coagulation laboratory methods such as rotational thromboelastometry (ROTEM) may be valuable in their diagnosis. The aim of this study was to evaluate the diagnostic role of ROTEM in PJI. METHODS: A diagnostic study was conducted including 65 patients who underwent revision total hip arthroplasty or total knee arthroplasty due to PJI (30 patients) or aseptic loosening (35 patients). Preoperative laboratory evaluation included conventional coagulation studies, inflammatory markers, and ROTEM analysis. These parameters were compared between patients with PJI and patients with aseptic loosening. RESULTS: Several ROTEM parameters differed in the patients with PJI, indicating a higher coagulation potential associated with PJI. Specifically, the development of PJI was associated with higher EXTEM maximum clot firmness (MCF) (odds ratio [OR], 1.12 [95% confidence interval (CI), 1.04 to 1.20]; p = 0.001). Among the ROTEM parameters, EXTEM MCF was found to have the highest diagnostic accuracy for PJI (area under the receiver operating characteristic curve, 0.850; sensitivity, 76.6%; specificity, 91.4%), which was comparable with C-reactive protein (CRP) (p = 0.22) and erythrocyte sedimentation rate (ESR) (p = 0.65), but higher than D-dimer (p = 0.037). Moreover, the combined diagnostic accuracy of elevated EXTEM MCF and CRP was improved compared with CRP alone (p = 0.019). CONCLUSIONS: Our results indicate that ROTEM analysis might be helpful for the detection of the hemostatic derangements that are associated with the development of PJI. However, because of the small size of this pilot study, further research is needed to investigate the value of incorporating viscoelastic studies in diagnostic scores for PJI. LEVEL OF EVIDENCE: Diagnostic Level III . See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Artritis Infecciosa , Artroplastia de Reemplazo de Cadera , Hemostáticos , Infecciones Relacionadas con Prótesis , Humanos , Proyectos Piloto , Tromboelastografía/efectos adversos , Infecciones Relacionadas con Prótesis/etiología , Proteína C-Reactiva/análisis , Artroplastia de Reemplazo de Cadera/efectos adversos , Artritis Infecciosa/complicaciones , Sedimentación Sanguínea , Biomarcadores , Sensibilidad y Especificidad
4.
J Thromb Thrombolysis ; 55(3): 536-544, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36843157

RESUMEN

Surgical resection of malignant bone tumors is associated with a high risk of venous thromboembolism (VTE). The purpose of this study was to evaluate the association between rotational thromboelastometry (ROTEM) parameters and VTE following oncologic resections, and to evaluate their prognostic capacity for this complication. A prospective observational study was conducted including 113 patients who underwent surgical resection of malignant bone tumors. ROTEM analysis and conventional coagulation studies were performed preoperatively and on the 2nd postoperative day, while patients were followed for the development of VTE. Logistic regression was used to assess the association between ROTEM parameters and occurrence of VTE. The area under the receiver operating characteristic curve (AUC), sensitivity and specificity were calculated as measures of discrimination and predictive accuracy. Fourteen patients (12.4%) developed symptomatic VTE. Development of VTE was associated with shortened INTEM CFT (Odds Ratio [OR] 0.90, 95% Confidence Interval [CI] 0.84 - 0.96, p = 0.004), higher INTEM A10 (OR 1.21, 95% CI 1.07 - 1.36, p = 0.002), higher INTEM MCF (OR 1.22, 95% CI 1.08 - 1.37, p = 0.001) and higher INTEM LI60 (OR 2.10, 95% CI 1.38 - 3.21, p = 0.001). An INTEM LI60 value indicative of fibrinolysis shutdown (≥ 98%) had the best predictive accuracy for VTE (AUC = 0.887, 95% CI 0.824 - 0.951, sensitivity = 100%, specificity = 67.0%), higher than that of D-dimer levels (p = 0.028). ROTEM parameters were promising predictors of symptomatic VTE. Fibrinolysis shutdown as reflected by ROTEM LI60 and high D-dimer levels can aid the identification of high-risk patients. Future studies should evaluate whether the addition of ROTEM findings to an expanded risk-assessing model can improve the predictive capacity and provide better guidance in thromboprophylaxis.


Asunto(s)
Trastornos de la Coagulación Sanguínea , Neoplasias Óseas , Tromboembolia Venosa , Humanos , Pronóstico , Tromboembolia Venosa/diagnóstico , Tromboembolia Venosa/etiología , Fibrinólisis , Anticoagulantes , Tromboelastografía , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Neoplasias Óseas/complicaciones
5.
Semin Thromb Hemost ; 49(2): 134-144, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36055277

RESUMEN

The frequency of red blood cell (RBC) transfusions is high in total joint arthroplasties, and the hemorrhagic risk is associated with both surgery- and patient-related factors. This study aims to assess the ability of rotational thromboelastometry (ROTEM) to identify patients at high risk for transfusion and excessive bleeding. A prospective observational study was conducted including 206 patients who underwent total knee or hip arthroplasties. Assessment of the coagulation status was performed preoperatively and immediately postoperatively using ROTEM analysis and conventional coagulation tests. The number of RBC transfusions and the postoperative hemoglobin drop were recorded. ROTEM findings were compared between transfused and nontransfused patients, and also between patients with and without excessive bleeding. Higher values of postoperative FIBTEM maximum clot firmness (MCF) were associated with lower risks of transfusion (odds ration [OR]: 0.66, 95% confidence interval [CI]: 0.57-0.78, p<0.001) and excessive bleeding (OR: 0.58, 95% CI: 0.36-0.94, p=0.028). A postoperative FIBTEM MCF value ≤10mm had 80.1% (95% CI: 73.1-85.9%) sensitivity with 75.5% (95% CI: 60.4-87.1%) specificity to predict transfusion requirements, and 70.5% (95% CI: 63.6-76.8%) sensitivity with 88.8% (95% CI: 51.7-99.7%) specificity to predict excessive bleeding. The estimated average probability of transfusion in patients with FIBTEM MCF values of 0 to 4mm is 86.3%. ROTEM assay demonstrated high predictive ability for transfusion and excessive bleeding. Identification of patients at risk for transfusion could allow blood banks to ensure adequate blood supply, while also more intense blood-salvaging strategies could be implemented in these patients.


Asunto(s)
Hemorragia , Tromboelastografía , Humanos , Pruebas de Coagulación Sanguínea , Transfusión Sanguínea , Artroplastia
6.
Curr Oncol ; 31(1): 211-228, 2023 12 29.
Artículo en Inglés | MEDLINE | ID: mdl-38248099

RESUMEN

BACKGROUND: The triad of 3D design, 3D printing, and xReality technologies is explored and exploited to collaboratively realize patient-specific products in a timely manner with an emphasis on designs with meta-(bio)materials. METHODS: A case study on pelvic reconstruction after oncological resection (osteosarcoma) was selected and conducted to evaluate the applicability and performance of an inter-epistemic workflow and the feasibility and potential of 3D technologies for modeling, optimizing, and materializing individualized orthopedic devices at the point of care (PoC). RESULTS: Image-based diagnosis and treatment at the PoC can be readily deployed to develop orthopedic devices for pre-operative planning, training, intra-operative navigation, and bone substitution. CONCLUSIONS: Inter-epistemic symbiosis between orthopedic surgeons and (bio)mechanical engineers at the PoC, fostered by appropriate quality management systems and end-to-end workflows under suitable scientifically amalgamated synergies, could maximize the potential benefits. However, increased awareness is recommended to explore and exploit the full potential of 3D technologies at the PoC to deliver medical devices with greater customization, innovation in design, cost-effectiveness, and high quality.


Asunto(s)
Oncología Médica , Sistemas de Atención de Punto , Humanos , Pelvis
7.
Orthopedics ; 45(6): e335-e341, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36098572

RESUMEN

Prosthetic reconstruction after wide resection of tumors of the proximal humerus presents a unique challenge. The shoulder is a complex articulation, and patients have high expectations for postoperative function. The goal of this study is to compare functional outcomes, oncologic outcomes, and complication rates for 2 reconstructive methods. Forty patients with proximal humeral tumors were reviewed retrospectively. Proximal humeral endoprosthesis (PHE) was used for 21 patients, and reverse shoulder arthroplasty (RSA) was used for 19 patients. Clinical results, oncologic outcomes, and complication rates were assessed. The functional outcomes of the patients were assessed with the Musculoskeletal Tumor Society scoring system (MSTS), the shortened version of the Disabilities of the Arm, Shoulder and Hand (QuickDASH) score, and shoulder range of motion. The mean follow-up was 62±15 months. Shoulder dislocations occurred among 8 patients with PHE and 1 patient with RSA (P=.021). The other complication rates were similar for the 2 groups (P<.05). At the latest follow-up, the mean MSTS score was 68±10.3 for those with PHE and 76±7.7 for the patients with RSA (P=.72). However, the QuickDASH score was significantly better (P=.031) for those with RSA (mean, 19±6.3) compared with patients with PHE (mean, 30±4.8). Additionally, shoulder active abduction and forward flexion were significantly greater for the RSA group (P=.04 and P=.03, respectively). Five patients had local recurrence. Prosthetic reconstruction after oncologic re-section of the proximal humerus is associated with significant limitation of shoulder range of motion and a high rate of revision surgery. However, in this study, RSA was associated with fewer dislocations, improved Quick-DASH score, and greater abduction and forward flexion compared with PHE. [Orthopedics. 2022;45(6):e335-e341.].


Asunto(s)
Artroplastía de Reemplazo de Hombro , Neoplasias Óseas , Fracturas del Hombro , Articulación del Hombro , Humanos , Hombro/cirugía , Articulación del Hombro/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Húmero/patología , Artroplastía de Reemplazo de Hombro/efectos adversos , Neoplasias Óseas/patología , Rango del Movimiento Articular , Fracturas del Hombro/cirugía
8.
Cancers (Basel) ; 14(16)2022 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-36010924

RESUMEN

Introduction: A detailed evaluation of the malignancy-associated coagulopathy (MAC) in surgical patients with bone tumors may allow for more effective thromboprophylactic measures. The purpose of this study was to assess the perioperative hemostatic changes in patients with bone tumors, using rotational thromboelastometry (ROTEM). Methods: An observational study was performed, including 50 patients with bone tumors who underwent oncologic resection and 30 healthy controls, matched for age and gender. The preoperative and postoperative laboratory evaluation of coagulation in both groups included conventional coagulation tests and a ROTEM analysis. The results of the conventional coagulation tests and the ROTEM analysis were compared between the two groups. Results: The results of the conventional coagulation tests were comparable between the tumor patients and the healthy controls. However, compared to the healthy adults, the tumor patients had lower CT (p < 0.001) and CFT (p < 0.001) values suggesting a rapid induction of the coagulation cascade, elevated A10 (p < 0.001) and MCF (p < 0.001) values indicating a higher clot strength and platelet activation, and elevated LI60 (p < 0.001) values indicating hypofibrinolysis in patients with bone tumors. The multiple linear regression analysis (controlling for potential confounding factors) confirmed the independent association of bone tumors with these hemostatic changes. Conclusions: Our results support the advantageous use of a ROTEM in patients with bone tumors over conventional coagulation tests because the qualitative changes in the hemostatic profile of these patients that can be detected by a ROTEM analysis cannot be identified by conventional tests. The ROTEM results indicate that the hypercoagulable state in patients with bone tumors is caused by the malignancy-associated activation of the coagulation cascade, platelet activation, and hypofibrinolysis.

9.
Thromb Haemost ; 122(6): 895-904, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34719014

RESUMEN

BACKGROUND: Hip fracture surgeries are associated with considerable blood loss, while the perioperative coagulopathy is associated with the bleeding risk of these patients. We aimed to evaluate the ability of rotational thromboelastometry (ROTEM) to detect patients at high risk for excessive bleeding and increased transfusion requirements. METHODS: We conducted a prospective observational study of 221 patients who underwent hip fracture surgeries. ROTEM analysis was performed preoperatively and immediately postoperatively. Blood loss parameters including blood loss volume, number of transfused red blood cell (RBC) units, and drop in hemoglobin levels were recorded. ROTEM parameters were compared between patients with and without excessive bleeding, and between patients with and without increased transfusion requirements (i.e., ≥2 RBC units). RESULTS: The postoperative FIBTEM MCF value ≤15 mm had 66.6% (95% confidence interval [CI]: 59.7-74.1%) sensitivity and 92.0% (95% CI: 80.7-97.7%) specificity to prognose excessive bleeding, and preoperative FIBTEM MCF value ≤15 mm had 80.4% (95% CI: 73.5-86.2%) sensitivity and 91.2% (95% CI: 80.7-97.0%) specificity to prognose increased transfusion requirements. Preoperative FIBTEM MCF ≤11 mm and postoperative FIBTEM MCF ≤15 mm were associated with considerably increased risks of excessive bleeding (odds ratio [OR]: 44.8, 95% CI: 16.5-121.3, p < 0.001; and OR: 23.0, 95% CI: 7.8-67.0, p < 0.001, respectively). CONCLUSION: ROTEM parameters demonstrated high prognostic accuracy for excessive bleeding and increased transfusion requirements. This can enable implementation of blood sparing strategies in high-risk patients, while blood banks could be better prepared to ensure adequate blood supply.


Asunto(s)
Trastornos de la Coagulación Sanguínea , Tromboelastografía , Transfusión Sanguínea , Hemorragia/etiología , Humanos , Pronóstico
10.
Cancers (Basel) ; 13(16)2021 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-34439106

RESUMEN

BACKGROUND: An endoprosthetic reconstruction in musculoskeletal oncology patients is associated with significant blood loss. The purpose of this study is to evaluate the safety and efficacy of tranexamic acid (TXA) for these patients and to assess any changes in their hemostatic profile using rotational thromboelastometry (ROTEM). METHODS: A retrospective observational study was performed including 61 patients with primary or metastatic bone tumors who underwent surgery. Group A (n = 30) received both intravenous and local TXA whereas Group B (n = 31) was the control group. The primary outcomes were perioperative blood loss and blood unit transfusions and the secondary outcomes included the incidence of thromboembolic complications and a change in blood coagulability as reflected by ROTEM parameters. RESULTS: The median difference in blood loss between the two groups was 548.5 mL, indicating a 29.2% reduction in the 72 h blood loss following TXA administration (p < 0.001). TXA also led to a reduced transfusion of 1 red blood cell (RBC) unit per patient (p < 0.001). The two groups had similar rates of thromboembolic complications (p = 0.99). The antifibrinolytic properties of TXA were confirmed by the significantly higher INTEM, FIBTEM and EXTEM LI60 (p < 0.001, p = 0.005 and p < 0.001, respectively) values in the TXA group. CONCLUSION: Tranexamic acid was associated with a significant reduction in perioperative blood loss and transfusion requirements without a complete shutdown of the fibrinolysis. Larger studies are warranted to assess the frequency of these outcomes in musculoskeletal oncology patients.

11.
J Clin Med ; 10(15)2021 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-34362178

RESUMEN

INTRODUCTION: Coronavirus disease 2019 (COVID-19) in patients with hip fractures is associated with increased incidence of venous thromboembolism (VTE). The purpose of this study was to evaluate the hemostatic alterations of COVID-19 that are associated with a higher thrombotic risk using rotational thromboelastometry (ROTEM). METHODS: A retrospective observational study was performed including 20 COVID-19 patients with hip fractures. To compare the coagulopathy of patients with mild COVID-19 and hip fractures with the coagulopathy associated with each of these two conditions separately, we used two previously recruited groups of patients; 198 hip fracture patients without COVID-19 and 21 COVID-19 patients without hip fractures. The demographics, clinical parameters, conventional coagulation parameters and ROTEM findings of the three groups were analyzed and compared. RESULTS: COVID-19 hip fracture patients had higher amplitude of clot firmness at 10 min (p < 0.001), higher alpha angle (p < 0.001), higher lysis index at 60 min (p < 0.001), and shorter clot formation time (p < 0.001) than non-COVID-19 hip fracture patients, indicating increased clot strength and impaired fibrinolysis due to COVID-19. The value of lysis index at 60 min (99%) in COVID-19 patients with hip fractures was consistent with fibrinolysis shut down. Multivariable linear regression analysis further confirmed that COVID-19 resulted in increased amplitude of clot firmness at 10 min (p < 0.001), increased maximum clot firmness (p < 0.001), increased lysis index at 60 min (p < 0.001) and increased alpha angle (p < 0.001), but significantly shortened clot formation time (p < 0.001). DISCUSSION: The higher thrombotic risk in COVID-19 patients with hip fractures is characterized by increased clot strength and fibrinolysis shutdown, as shown by ROTEM findings. Further prospective studies are warranted to evaluate the need for modification of thromboprophylaxis to balance the hemostatic derangements of COVID-19 patients with hip fractures.

12.
Clin Orthop Relat Res ; 479(11): 2457-2467, 2021 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-34076610

RESUMEN

BACKGROUND: Venous thromboembolism is a common complication after hip fractures. However, there are no reliable laboratory assays to identify patients at risk for venous thromboembolic (VTE) events after major orthopaedic surgery. QUESTION/PURPOSES: (1) Are rotational thromboelastometry (ROTEM) findings associated with the presence or development of symptomatic VTE after hip fracture surgery? (2) Were any other patient factors associated with the presence or development of symptomatic VTE after hip fracture surgery? (3) Which ROTEM parameters were the most accurate in terms of detecting the association of hypercoagulability with symptomatic VTE? METHODS: This retrospective study was conducted over a 13-month period. In all, 354 patients with femoral neck and peritrochanteric fractures who underwent hip hemiarthoplasty or cephallomedullary nailing were assessed for eligibility. Of those, 99% (349 of 354) were considered eligible for the study, 1% (3 of 354) of patients were excluded due to coagulation disorders, and another 1% (2 of 354) were excluded because they died before the postoperative ROTEM analysis. An additional 4% (13 of 354) of patients were lost before the minimum study follow-up of 3 months, leaving 95% (336 of 354) for analysis. A ROTEM analysis was performed in all patients at the time of their hospital admission, within hours of the injury, and on the second postoperative day. The patients were monitored for the development of symptoms indicative of VTE, and the gold standard tests for diagnosing VTE, such as CT pulmonary angiography or vascular ultrasound, were selectively performed only in symptomatic patients and not routinely in all patients. Therefore, this study evaluates the association of ROTEM with only clinically evident VTE events and not with all VTE events. ROTEM results did not affect the clinical surveillance of the study group and the decision for further work up. To determine whether ROTEM findings were associated with the presence or development of symptomatic VTE, ROTEM parameters were compared between patients with and without symptomatic VTE. To establish whether any other patient factors were associated with the presence or development of symptomatic VTE after hip fracture surgery, clinical parameters and conventional laboratory values were also compared between patients with and without symptomatic VTE. Finally, to determine which ROTEM parameters were the most accurate in terms of detecting the association of hypercoagulability with symptomatic VTE, the area under the curve (AUC) for certain cut off values of ROTEM parameters was calculated. RESULTS: We found several abnormal ROTEM values to be associated with the presence or development of symptomatic VTE. The preoperative maximum clot firmness was higher in patients with clinically evident VTE than in patients without these complications (median [interquartile range] 70 mm [68 to 71] versus 65 mm [61 to 68]; p < 0.001). The preoperative clot formation time was lower in patients with clinically evident VTE than those without clinically evident VTE (median 61 seconds [58 to 65] versus 70 seconds [67 to 74]; p < 0.001), and also the postoperative clot formation time was lower in patients with clinically evident VTE than those without these complications (median 52 seconds [49 to 59] versus 62 seconds [57 to 68]; p < 0.001). Increased BMI was also associated with clinically evident VTE (odds ratio 1.26 [95% confidence interval 1.07 to 1.53]; p < 0.001). We found no differences between patients with and without clinically evident VTE in terms of age, sex, smoking status, comorbidities, and preoperative use of anticoagulants. Lastly, preoperative clot formation time demonstrated the best performance for detecting the association of hypercoagulability with symptomatic VTE (AUC 0.89 [95% CI 0.81 to 0.97]), with 81% (95% CI 48% to 97%) sensitivity and 86% (95% CI 81% to 89%) specificity for clot formation time ≤ 65 seconds. CONCLUSION: ROTEM's performance in this preliminary study was promising in terms of its association with symptomatic VTE. This study extended our earlier work by demonstrating that ROTEM has a high accuracy in detecting the level of hypercoagulability that is associated with symptomatic VTE. However, until its performance is validated in a study that applies a diagnostic gold standard (such as venography, duplex/Doppler, or chest CT) in all patients having ROTEM to confirm its performance, ROTEM should not be used as a regular part of clinical practice. LEVEL OF EVIDENCE: Level IV, diagnostic study.


Asunto(s)
Fracturas de Cadera/diagnóstico por imagen , Complicaciones Posoperatorias/etiología , Tromboelastografía/estadística & datos numéricos , Tromboembolia Venosa/etiología , Anciano , Femenino , Fijación Interna de Fracturas/efectos adversos , Factores de Riesgo de Enfermedad Cardiaca , Hemiartroplastia/efectos adversos , Fracturas de Cadera/fisiopatología , Fracturas de Cadera/cirugía , Humanos , Masculino , Complicaciones Posoperatorias/diagnóstico , Valor Predictivo de las Pruebas , Periodo Preoperatorio , Estudios Retrospectivos , Medición de Riesgo , Tromboembolia Venosa/diagnóstico
13.
Int J Lab Hematol ; 43(3): 477-484, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33231378

RESUMEN

INTRODUCTION: Trauma-induced coagulopathy has been extensively investigated in the multitrauma setting, but only sparsely following moderate orthopedic trauma. The purpose of this study was to evaluate changes in the hemostatic profile of patients with hip fractures, using rotational thromboelastometry (ROTEM). METHODS: 198 patients with hip fractures who underwent surgery were included in the study. A matched group of 52 healthy individuals was also enrolled. Demographics, conventional laboratory assays, and ROTEM parameters were recorded and compared between patients and healthy adults. The preoperative and postoperative ROTEM values of fractured patients were also compared. RESULTS: The conventional coagulation assays were similar for the 2 groups. However, several ROTEM parameters including EXTEM MCF (P < .001), EXTEM alpha angle (P < .001), INTEM MCF (P < .001), INTEM A10 (P < .001), and INTEM alpha angle (P < .001) significantly differed between the 2 groups indicating a higher coagulation potential following hip fractures. Also, fractured patients had significantly lower INTEM and EXTEM CT values (P = .008 and P = .012, respectively) and significantly lower INTEM and EXTEM CFT values (P < .001). Adjusted analysis for confounders further confirmed the direct relationship between hip fracture and higher coagulation activity. Last, INTEM CT and CFT significantly decreased (P = .008 and P < .001, respectively), while INTEM MCF, A10, and alpha angle significantly increased (P < .001) postoperatively, indicating that surgery further increases the coagulation potential. CONCLUSION: A higher coagulation activity following hip fractures and surgical treatment can be detected by ROTEM shortly after the injury, even when this is undetectable by conventional coagulation assays.


Asunto(s)
Coagulación Sanguínea , Fracturas de Cadera/sangre , Tromboelastografía , Trombofilia/sangre , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Femenino , Fracturas de Cadera/complicaciones , Fracturas de Cadera/cirugía , Humanos , Masculino , Periodo Posoperatorio , Periodo Preoperatorio , Tromboelastografía/métodos , Trombofilia/complicaciones
14.
J Long Term Eff Med Implants ; 30(1): 69-76, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33389918

RESUMEN

The aim of the study was to evaluate the outcomes of pedestal cup and METS coned hemipelvis implants for periacetabular reconstruction after type II pelvic resections, including complications, failure rates, and functional outcomes. We retrospectively reviewed 25 patients, divided in two groups, who underwent internal hemipelvectomy and periacetabular reconstruction using either a pedestal cup (Group A = 13) or a METS coned hemipelvis (Group B = 12). The clinical, radiological, and oncological outcomes, as well as the complications, were assessed. There were no differences between the two groups regarding capacity for independent walking at 12 months and functional results. Mechanical and nonmechanical complication rates were also similar for the two groups. The two-year cumulative incidence of failure was 7.6% (95% CI 0.3-18.3) for group A and 8.8% (95% CI 1.7-20.1) for group B, while the four-year cumulative incidence of failure was 11% (95% CI 0.2-28.9) and 14.1% (95% CI 2.2-33.1), respectively. This study showed that both types of pelvic implants are reliable options for periacetabular reconstruction of bone defects after type II oncologic pelvic resections, having similar complication rates and functional results.


Asunto(s)
Neoplasias Óseas , Neoplasias Óseas/cirugía , Humanos , Complicaciones Posoperatorias/epidemiología , Diseño de Prótesis , Estudios Retrospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...