Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Stud Health Technol Inform ; 310: 1364-1365, 2024 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-38270045

RESUMEN

Alzheimer's disease and other dementias are becoming more prevalent and placing increasing burdens on the community. The ADNeT Screening and Trials initiative aims to improve research outcomes by identifying people with an increased risk of developing these diseases and directing them to suitable clinical trials. To support the initiative, we have developed a modular informatics platform utilizing private cloud deployment to securely manage operational and research data across six clinical sites.


Asunto(s)
Enfermedad de Alzheimer , Humanos , Australia , Enfermedad de Alzheimer/diagnóstico , Enfermedad de Alzheimer/terapia , Informática
2.
MAGMA ; 36(5): 823-836, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36847989

RESUMEN

OBJECTIVE: The Fluid And White matter Suppression (FLAWS) MRI sequence provides multiple T1-weighted contrasts of the brain in a single acquisition. However, the FLAWS acquisition time is approximately 8 min with a standard GRAPPA 3 acceleration factor at 3 T. This study aims at reducing the FLAWS acquisition time by providing a new sequence optimization based on a Cartesian phyllotaxis k-space undersampling and a compressed sensing (CS) reconstruction. This study also aims at showing that T1 mapping can be performed with FLAWS at 3 T. MATERIALS AND METHODS: The CS FLAWS parameters were determined using a method based on a profit function maximization under constraints. The FLAWS optimization and T1 mapping were assessed with in-silico, in-vitro and in-vivo (10 healthy volunteers) experiments conducted at 3 T. RESULTS: In-silico, in-vitro and in-vivo experiments showed that the proposed CS FLAWS optimization allows the acquisition time of a 1 mm-isotropic full-brain scan to be reduced from [Formula: see text] to [Formula: see text] without decreasing image quality. In addition, these experiments demonstrate that T1 mapping can be performed with FLAWS at 3 T. DISCUSSION: The results obtained in this study suggest that the recent advances in FLAWS imaging allow to perform multiple T1-weighted contrast imaging and T1 mapping in a single [Formula: see text] sequence acquisition.


Asunto(s)
Sustancia Blanca , Humanos , Sustancia Blanca/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Neuroimagen , Cabeza , Procesamiento de Imagen Asistido por Computador
3.
Hum Brain Mapp ; 42(18): 5911-5926, 2021 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-34547147

RESUMEN

Quadrantanopia caused by inadvertent severing of Meyer's Loop of the optic radiation is a well-recognised complication of temporal lobectomy for conditions such as epilepsy. Dissection studies indicate that the anterior extent of Meyer's Loop varies considerably between individuals. Quantifying this for individual patients is thus an important step to improve the safety profile of temporal lobectomies. Previous attempts to delineate Meyer's Loop using diffusion MRI tractography have had difficulty estimating its full anterior extent, required manual ROI placement, and/or relied on advanced diffusion sequences that cannot be acquired routinely in most clinics. Here we present CONSULT: a pipeline that can delineate the optic radiation from raw DICOM data in a completely automated way via a combination of robust pre-processing, segmentation, and alignment stages, plus simple improvements that bolster the efficiency and reliability of standard tractography. We tested CONSULT on 696 scans of predominantly healthy participants (539 unique brains), including both advanced acquisitions and simpler acquisitions that could be acquired in clinically acceptable timeframes. Delineations completed without error in 99.4% of the scans. The distance between Meyer's Loop and the temporal pole closely matched both averages and ranges reported in dissection studies for all tested sequences. Median scan-rescan error of this distance was 1 mm. When tested on two participants with considerable pathology, delineations were successful and realistic. Through this, we demonstrate not only how to identify Meyer's Loop with clinically feasible sequences, but also that this can be achieved without fundamental changes to tractography algorithms or complex post-processing methods.


Asunto(s)
Imagen de Difusión Tensora/métodos , Interpretación de Imagen Asistida por Computador/métodos , Vías Visuales/anatomía & histología , Vías Visuales/diagnóstico por imagen , Adulto , Lobectomía Temporal Anterior/métodos , Femenino , Humanos , Masculino , Cuidados Preoperatorios/métodos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...