Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 14(1): 12564, 2024 05 31.
Artículo en Inglés | MEDLINE | ID: mdl-38822053

RESUMEN

Next-generation sequencing (NGS) is emerging as a powerful tool for molecular diagnostics but remains limited by cumbersome and inefficient sample preparation. We present an innovative automated NGS library preparation system with a simplified mechanical design that exploits both macro- and microfluidic properties for optimizing heat transfer, reaction kinetics, mass transfer, fluid mechanics, adsorption-desorption rates, and molecular thermodynamics. Our approach introduces a unique two-cannula cylindrical capillary system connected to a programmable syringe pump and a Peltier heating element able to execute all steps with high efficiency. Automatic reagent movement, mixing, and magnetic bead-based washing with capillary-based thermal cycling (capillary-PCR) are completely integrated into a single platform. The manual 3-h library preparation process is reduced to less than 15 min of hands-on time via optimally pre-plated reagent plates, followed by less than 6 h of instrument run time during which no user interaction is required. We applied this method to two library preparation assays with different DNA fragmentation requirements (mechanical vs. enzymatic fragmentation), sufficiently limiting consumable use to one cartridge and one 384 well-plate per run. Our platform successfully prepared eight libraries in parallel, generating sequencing data for both human and Escherichia coli DNA libraries with negligible coverage bias compared to positive controls. All sequencing data from our libraries attained Phred (Q) scores > 30, mapping to reference genomes at 99% confidence. The method achieved final library concentrations and size distributions comparable with the conventional manual approach, demonstrating compatibility with downstream sequencing and subsequent data analysis. Our engineering design offers repeatability and consistency in the quality of sequence-able libraries, asserting the importance of mechanical design considerations that employ and optimize fundamental fluid mechanics and heat transfer properties. Furthermore in this work, we provide unique insights into the mechanisms of sample loss within NGS library preparation assays compared with automated adaptations and pinpoint areas in which the principles of thermodynamics, fluid mechanics, and heat transfer can improve future mechanical design iterations.


Asunto(s)
Biblioteca de Genes , Secuenciación de Nucleótidos de Alto Rendimiento , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Calor , Humanos , Termodinámica , Análisis de Secuencia de ADN/métodos
2.
ACS Appl Mater Interfaces ; 16(21): 26984-26997, 2024 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-38753459

RESUMEN

Lipid nanoparticles (LNPs) are clinically advanced nonviral gene delivery vehicles with a demonstrated ability to address viral, oncological, and genetic diseases. However, the further development of LNP therapies requires rapid analytical techniques to support their development and manufacturing. The method developed and described in this paper presents an approach to rapidly and accurately analyze LNPs for optimized therapeutic loading by utilizing an electrophoresis microfluidic platform to analyze the composition of LNPs with different clinical lipid compositions (Onpattro, Comirnaty, and Spikevax) and nucleic acid (plasmid DNA (pDNA) and messenger RNA (mRNA)) formulations. This method enables the high-throughput screening of LNPs using a 96- or 384-well plate with approximate times of 2-4 min per sample using a total volume of 11 µL. The lipid analysis requires concentrations approximately between 109 and 1010 particles/mL and has an average precision error of 10.4% and a prediction error of 19.1% when compared to using a NanoSight, while the nucleic acid analysis requires low concentrations of 1.17 ng/µL for pDNA and 0.17 ng/µL for mRNA and has an average precision error of 4.8% and a prediction error of 9.4% when compared to using a PicoGreen and RiboGreen assay. In addition, our method quantifies the relative concentration of nucleic acid per LNP. Utilizing this approach, we observed an average of 263 ± 62.2 mRNA per LNP and 126.3 ± 21.2 pDNA per LNP for the LNP formulations used in this study, where the accuracy of these estimations is dependent on reference standards. We foresee the utility of this technique in the high-throughput characterization of LNPs during manufacturing and formulation research and development.


Asunto(s)
ADN , Lípidos , Nanopartículas , Plásmidos , ARN Mensajero , ARN Mensajero/genética , Nanopartículas/química , Plásmidos/genética , ADN/química , Lípidos/química , Humanos , Microfluídica/métodos , Técnicas de Transferencia de Gen , Electroforesis , Liposomas
3.
Electrophoresis ; 2024 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-38571381

RESUMEN

The recent rise in nucleic acid-based vaccines and therapies has resulted in an increased demand for plasmid DNA (pDNA). As a result, there is added pressure to streamline the manufacturing of these vectors, particularly their design and construction, which is currently considered a bottleneck. A significant challenge in optimizing pDNA production is the lack of high-throughput and rapid analytical methods to support the numerous samples produced during the iterative plasmid construction step and for batch-to-batch purity monitoring. pDNA is generally present as one of three isoforms: supercoiled, linear, or open circular. Depending on the ultimate use, the desired isoform may be supercoiled in the initial stages for cell transfection or linear in the case of mRNA synthesis. Here, we present a high-throughput microfluidic electrophoresis method capable of detecting the three pDNA isoforms and determining the size and concentration of the predominant supercoiled and linear isoforms from 2 to 7 kb. The limit of detection of the method is 0.1 ng/µL for the supercoiled and linear isoforms and 0.5 ng/µL for the open circular isoform, with a maximum loading capacity of 10-15 ng/µL. The turnaround time is 1 min/sample, and the volume requirement is 10 µL, making the method suitable for process optimization and batch-to-batch analysis. The results presented in this study will enhance the understanding of electrophoretic transport in microscale systems dependent on molecular conformations and potentially aid technological advances in diverse areas relevant to microfluidic devices.

4.
Analyst ; 149(5): 1509-1517, 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38265070

RESUMEN

The versatility, rapid development, and ease of production scalability of mRNA therapeutics have placed them at the forefront of biopharmaceutical research. However, despite their vast potential to treat diseases, their novelty comes with unsolved analytical challenges. A key challenge in ensuring sample purity has been monitoring residual, immunostimulatory dsRNA impurities generated during the in vitro transcription of mRNA. Here, we present a method that combines an enzyme, S1 nuclease, to identify and isolate dsRNA from an mRNA sample with a microfluidic electrophoresis analytical platform to characterize the impurity. After the method was developed and optimized, it was tested with clinically relevant, pseudouridine-modified 700 and 1800 bp dsRNA and 818-4451 nt mRNA samples. While the treatment impacted the magnitude of the fluorescent signal used to analyze the samples due to the interference of the buffer with the labeling of the sample, this signal loss was mitigated by 8.8× via treatment optimization. In addition, despite the mRNA concentration being up to 400× greater than that of the dsRNA, under every condition, there was a complete disappearance of the main mRNA peak. While the mRNA peak was digested, the dsRNA fragments remained physically unaffected by the treatment, with no change to their migration time. Using these samples, we detected 0.25% dsRNA impurities in mRNA samples using 15 µL with an analytical runtime of 1 min per sample after digestion and were able to predict their size within 8% of the expected length. The short runtime, sample consumption, and high throughput compatibility make it suitable to support the purity assessment of mRNA during purification and downstream.


Asunto(s)
Microfluídica , Vacunas de ARNm , ARN Bicatenario/genética , Electroforesis , ARN Mensajero/genética
5.
ACS Omega ; 9(3): 4027-4036, 2024 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-38284067

RESUMEN

Despite recent advances in nucleic acid delivery systems with the success of LNP vehicles, adeno-associated virus (AAV) remains the leading platform for targeted gene delivery due to its low immunogenicity to humans, high transduction efficiency, and range of serotypes with varying tropisms. Depending on the therapeutic goals and serotype used, different production conditions may be more amenable, generating an ever-growing need for rapid yet robust analytical techniques to support the high-quality manufacturing of AAV. A critical bottleneck exists for assessing full capsids where rapid, high-throughput techniques capable of analyzing a range of serotypes are needed. Here, we present a rapid, high-throughput analytical technique, microfluidic electrophoresis, for the assessment of full capsids compatible with AAV1, AAV2, AAV6, AAV8, and AAV9 without the need for assay modifications or optimizations, and AAV5 with some constraints. The method presented in this study uses a mathematical formulation we developed previously with a reference standard to combine the independently obtained capsid protein and single-stranded DNA (ssDNA) profiles to estimate the percentage of full capsids in a sample of unknown concentration. We assessed the ability to use a single serotype (AAV8) as the reference standard regardless of the serotype of the sample being analyzed so long as the melting temperature (Tm) of the capsids is within 12 °C from the Tm of AAV8. Using this method, we are able to characterize samples ±6.1% with an average analytical turnaround time of <5 min/sample, using only 10 µL/sample at a concentration of 2.5 × 1012 VG/mL.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA