Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Vojnosanit Pregl ; 69(1): 43-8, 2012 Jan.
Artículo en Serbio | MEDLINE | ID: mdl-22397296

RESUMEN

BACKGROUND/AIM: Military personnel is a population group at special risk of exposure to sexually transmitted diseases (STD). In peacetime, STD infection rates among service members are generally 2 to 5 times higher than among civilian population. In time of conflict, the differences can be 50 or more times greater. This study describes sexual behavior as a risk factor for STD in the Armed Forces of Serbia. METHODS: The sample of 5 617 voluntary blood donors from the Armed Forces of Serbia gave blood and filled World Health Organization Questionnaire about sexual behavior within January 2007 - December 2008 period. The mandatory testing of voluntary blood donors was performed in the Institute of Transfusiology Military Medical Academy in Belgrade, by the specific immunoenzyme tests and polymerasa chain reaction tests for HIV, hepatitis B, C and syphilis. Statistical analysis of data was done using State for Windows 93, USA, 1996. RESULTS: We identified 36 soldiers with some form of STDs. This study showed that 1 668 (29.7%) tested soldiers reported always using condoms, 1 725 (30.72%) almost always, 1 238 (20.04%) sometimes, 495 (8.81%) almost never and 490 (8.73%) never. Among the sample, 449 (7.99%) soldiers reported sexual contacts with partners with high risk of sexual behavior, whilst 22 (0.37%) of them reported homosexual and bisexual contacts. CONCLUSION: This study reported STDs found in voluntary blood donors among the service members of the Armed Forces of Serbia, but none of them was identified to be HIV positive. Soldiers with the most frequent risk behavior were reported to be those with inconsistent condom use. In the future, the STD Control and Prevention Program should be more intensively conducted among the members of the Armed Forces of Serbia.


Asunto(s)
Infecciones por VIH/epidemiología , Personal Militar , Enfermedades de Transmisión Sexual/epidemiología , Síndrome de Inmunodeficiencia Adquirida/epidemiología , Adolescente , Adulto , Donantes de Sangre , Condones/estadística & datos numéricos , Femenino , Infecciones por VIH/diagnóstico , Hepatitis B/diagnóstico , Hepatitis B/epidemiología , Hepatitis C/diagnóstico , Hepatitis C/epidemiología , Humanos , Masculino , Serbia/epidemiología , Conducta Sexual , Enfermedades de Transmisión Sexual/diagnóstico , Sífilis/diagnóstico , Sífilis/epidemiología , Adulto Joven
2.
Vojnosanit Pregl ; 68(12): 1041-6, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22352265

RESUMEN

BACKGROUND/AIM: Bacterial contamination of blood components, primarily platelet concentrates (PCs), has been identified as one of the most frequent infectious complications in transfusion practice. PC units have a high risk for bacterial growth/multiplication due to their storage at ambient temperature (20 +/- 2 degrees C). Consequences of blood contamination could be effectively prevented or reduced by pathogen inactivation systems. The aim of this study was to determine the Mirasol pathogen reduction technology (PRT) system efficacy in PCs using an artificial bacteria-contamination model. METHODS: According to the ABO blood groups, PC units (n = 216) were pooled into 54 pools (PC-Ps). PC-Ps were divided into three equal groups, with 18 units in each, designed for an artificial bacteria-contamination. Briefly, PC-Ps were contaminated by Staphylococcus epidermidis, Staphylococcus aureus or Escherichia coli in concentrations 10(2) to 10(7) colony forming units (CFU) per unit. Afterward, PC-Ps were underwent to inactivation by Mirasol PRT system, using UV (lambda = 265-370 nm) activated riboflavin (RB). All PC-Ps were assayed by BacT/Alert Microbial Detection System for CFU quantification before and after the Mirasol treatment. Samples from non-inactivated PC-P units were tested after preparation and immediately following bacterial contamination. Samples from Mirasol treated units were quantified for CFUs one hour, 3 days and 5 days after inactivation. Results. A complete inactivation of all bacteria species was obtained at CFU concentrations of 10(2) and 10(3) per PC-P unit through storage/investigation period. The most effective inactivation (10(5) CFU per PC-P unit) was obtained in Escherichia coli setting. Contrary, inactivation of all the three tested bacteria species was unworkable in concentrations of > or = 10(6) CFU per PC-P unit. CONCLUSION: Efficient inactivation of investigated bacteria types with a significant CFU depletion in PC-P units was obtained--3 Log for all three tested species, and 5 Log for Escherichia coli. The safety of blood component therapy, primarily the clinical use of PCs can be improved using the Mirasol PRT system.


Asunto(s)
Plaquetas , Escherichia coli/efectos de la radiación , Transfusión de Plaquetas , Staphylococcus/efectos de la radiación , Rayos Ultravioleta , Infecciones Bacterianas/etiología , Infecciones Bacterianas/prevención & control , Humanos , Transfusión de Plaquetas/efectos adversos
3.
Vojnosanit Pregl ; 67(12): 998-1002, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21417103

RESUMEN

BACKGROUND: In countries without a national organization for retrieval and distribution of organs of the deceased donors, problem of organ shortage is still not resolved. In order to increase the number of kidney transplantations we started with the program of living unrelated - spousal donors. The aim of this study was to compare treatment outcome and renal graft function in patients receiving the graft from spousal and those receiving ghe graft from living related donors. METHOD: We retrospectively identified 14 patients who received renal allograft from spousal donors between 1996 and 2009 (group I). The control group consisted of 14 patients who got graft from related donor retrieved from the database and matched than with respect to sex, age, kidney disease, immunological and viral pretransplant status, the initial method of the end stage renal disease treatment and ABO compatibility. In the follow-up period of 41 +/- 38 months we recorded immunosuppressive therapy, surgical complications, episodes of acute rejection, CMV infection and graft function, assessed by serum creatinine levels at the beginning and in the end of the follow-up period. All patients had pretransplant negative cross-match. In ABO incompatible patients pretransplant isoagglutinine titer was zero. RESULTS: The patients with a spousal donor had worse HLA matching. There were no significant differences between the groups in surgical, infective, immunological complications and graft function. Two patients from the group I returned to hemodialysis after 82 and 22 months due to serious comorbidities. CONCLUSION: In spite of the worse HLA matching, graft survival and function of renal grafts from spousal donors were as good as those retrieved from related donors.


Asunto(s)
Trasplante de Riñón , Donadores Vivos , Esposos , Femenino , Histocompatibilidad , Humanos , Trasplante de Riñón/efectos adversos , Masculino , Persona de Mediana Edad
4.
Vojnosanit Pregl ; 65(7): 545-51, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18700465

RESUMEN

BACKGROUND/AIM: The use of peripheral blood as a source of hematopoietic stem cells (SCs) is progressively increasing and has nearly supplanted bone marrow transplantation. Interpatient variability in the degree and kinetics of SC mobilization into peripheral blood is an expected event after conventional chemotherapy-based treatment, followed by sequential administration of recombinant granulocyte-colony-stimulating factor (rHu-CSF). In this study, specific factors associated with the application of two different SC-harvesting approaches, including the use of large volume leukapheresis (LVL) vs. repetitive conventional apheresis (RCA), were analyzed. The basic goal of the study was to evaluate the influence of apheresis protocol (collection timing, processed blood volume and cell yield) upon the clinical outcome of transplantation. METHODS: Results obtained by LVL (76 pts) and RCA (20 pts--control group) were compared. The SC mobilizing regimen used was cyclophosphamide (4-7 g/m2) or polychemotherapy and rHuG-CSF 10-16 microg/kg of body mess (bm) per day. Cell harvesting was performed using Caridian-BCT Spectra (Gambro, USA). The volume of processed blood in LVL setting was > or = 3.5-fold of the patient's circulating blood quantity (ranged from 12.7 to 37.8 l). All patients tolerated well the use of intensive treatment, without any side or adverse effects. Our original controlled-rate cryopreservation was carried out with 10% dimethyl sulfoxide (DMSO) using Planer R203/200R or Planer 560-16 equipments (Planer Products Ltd, UK). Total nucleated cell (NC) and mononuclear cell (MNC) counts were examined by flow cytometry (Advia-2120 Bayer, Germany; Technicon H-3 System, USA). The CD34+ cell surface antigen was investigated by the EPICS XL-MCL device (Coulter, Germany). RESULTS: Performing LVL-apheresis, high-level MNC and CD34+ cell yields (7.6 +/- 4.6 x 10(8)/kg bm and 11.8 +/- 6.5 x 10(6)/kg bm, respectively) were obtained. As a result, rapid hematopoietic reconstitution ("graft-healing")--on the 9.4th and 12.4th day for granulocytes and platelets, respectively was achieved. Using repetitive conventional apheresis (2-3 procedures), the total MNC count was high (8.2 +/- 7.0 x 10(8)/kg bm), but the total CD34+ yield was lower 10.8 +/- 9.9 due to inferior CD34+ vs. MNC ratio. CONCLUSION: The results obtained suggest that well-timed LVL-apheresis increased SC-yield in cell harvest, resulting in faster bone marrow repopulation and hematological reconstitution, as well as better overall clinical outcome of transplantation. These results necessitate additional examinations of CD34+ subsets ratio in cell harvest.


Asunto(s)
Citaféresis/métodos , Movilización de Célula Madre Hematopoyética , Trasplante de Células Madre Hematopoyéticas , Adolescente , Adulto , Ciclofosfamida/administración & dosificación , Femenino , Factor Estimulante de Colonias de Granulocitos/administración & dosificación , Humanos , Leucaféresis/métodos , Masculino , Persona de Mediana Edad , Proteínas Recombinantes , Trasplante Autólogo
5.
Transfus Apher Sci ; 36(3): 225-33, 2007 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-17572153

RESUMEN

There is a need for improvement of the detection and treatment of the antibody-mediated graft rejection for ABO-incompatible kidney transplant recipients. With the development of novel pre-conditioning protocols, which employ anti-CD20 antibody, therapeutic plasma exchange plus extracorporeal immunoadsorption and standard immunosuppression application, together with the use of more sensitive and objective assays for immunological monitoring, patients that were not candidates for kidney transplant in the past, are now being transplanted. We have designed a pre-conditioning protocol for ABO-incompatible kidney transplants based on TPE plus our own simple "closed-circuit" immunoadsorption technique - combined by anti-CD20, standard immunosuppressive treatment, and without splenectomy. The results obtained in this study strongly support our hypothesis leading to the conclusion that this protocol can be used successfully, with high-quality ABO antibody depletion (p<0.001) and beneficial clinical findings. The application of this protocol is safe, and not associated with alteration in normal plasma constituent levels or with occurrence of any side effects of apheresis or clinical consequences. Finally, this pre-conditioning protocol radically reduces the treatment-cost. Definitive conclusions can only be drawn from larger, randomized, controlled clinical trials.


Asunto(s)
Sistema del Grupo Sanguíneo ABO/inmunología , Anticuerpos/uso terapéutico , Incompatibilidad de Grupos Sanguíneos/tratamiento farmacológico , Técnicas de Inmunoadsorción , Trasplante de Riñón/métodos , Adulto , Antígenos CD20/inmunología , Femenino , Rechazo de Injerto/prevención & control , Humanos , Trasplante de Riñón/inmunología , Masculino , Persona de Mediana Edad , Proyectos Piloto
6.
Vojnosanit Pregl ; 63(3): 261-8; discussion 269-70, 2006 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-16605192

RESUMEN

BACKGROUND/AIM: Thermodynamical and cryobiological parameters responsible for cell damages during cryopreservation (cryoinjuries) have not yet been completely explained. Thus, freezing procedures should be revised, exactly optimized to obtain an enhanced structural and functional recovery of frozen-thawed cells. The aim of this study was to compare microprocessor-controlled (controlled-rate) with the compensation of the released fusion heat and "dump-freezing" (uncontrolled-rate) of the platelet and lymphocyte cryopreservation efficacy. METHODS: Platelet quantitative recovery (post-thaw vs. unfrozen cell count), viability (using hypotonic shock response--HSR), morphological score (PMS), ultrastructural (electron microscopy) properties and expression of different surface antigens were investigated. In lymphocyte setting, cell recovery and viability (using trypan blue exclusion test) as well as functionality (by plant mitogens) were determined. Controlled-rate freezing and uncontrolled-rate cryopreservation were combined with 6% (platelets) and 10% (lymphocytes) dimethyl sulfoxide (DMSO). RESULTS: Platelet recovery and functionality were superior in the controlled-rate system. The majority of surface antigen expression was reduced in both freezing groups vs. unfrozen cells, but GP140/CD62p was significantly higher in controlled-rate vs. uncontrolled-rate setting. Controlled-rate freezing resulted with better lymphocyte recovery and viability (trypan blue-negative cell percentage). In mitogen-induced lymphocyte proliferative response no significant intergroup difference (controlled-rate vs. uncontrolled-rate) were found. CONCLUSION: The data obtained in this study showned the dependence of cell response on the cryopreservation type. Controlled-rate freezing provided a superior platelet quantitative and functional recovery. Lymphocyte recovery and viability were better in the controlled-rate group, although only a minor intergroup difference for cell proliferative response was obtained.


Asunto(s)
Plaquetas , Criopreservación , Linfocitos , Plaquetas/citología , Plaquetas/ultraestructura , División Celular , Supervivencia Celular , Criopreservación/métodos , Humanos , Linfocitos/citología , Linfocitos/ultraestructura
7.
Transfusion ; 46(2): 230-5, 2006 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-16441600

RESUMEN

BACKGROUND: Cryobiologic variables responsible for cell injuries and freezing techniques applicable in medical cryopractice should be revised and/or reengineered for minimizing cryoinjuries and maximizing cell recovery. In this study, the efficacy of different cryopreservation protocols based on platelet (PLT) recovery was evaluated. STUDY DESIGN AND METHODS: PLTs (n = 33) were prepared from whole-blood units. Cell count and viability, PLT morphologic score (PMS), and hypotonic shock response were determined. PLT surface antigens were measured by flow cytometry. Controlled-rate (with compensated fusion heat) and uncontrolled-rate freezing methods combined with 6 percent dimethyl sulfoxide were used. RESULTS: PLT recovery was superior in the controlled-rate setting (91.0 +/- 5.5 vs. 86.0 +/- 6.5; p < 0.05). PMS was significantly better in controlled-rate freezing (p < 0.01). GPIb/CD42b expression was reduced in both freezing groups versus control. GP140/CD62p expression was significantly (p < 0.05) lower in the controlled-rate group and in both frozen groups was significantly higher than in the control groups. CONCLUSION: The use of strictly equalized (1 degrees C/min) controlled-rate freezing, combined with an intensified cooling rate (2 degrees C/min) during the liquid-to-solid-phase transition period, allows advanced quantitative and qualitative PLT recovery, even though the minor intergroup differences for some variables were observed.


Asunto(s)
Plaquetas/citología , Conservación de la Sangre/métodos , Criopreservación/métodos , Adulto , Antígenos de Plaqueta Humana/metabolismo , Plaquetas/metabolismo , Forma de la Célula , Supervivencia Celular , Citometría de Flujo , Congelación , Humanos , Masculino
8.
Transfusion ; 44(8): 1197-203, 2004 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-15265124

RESUMEN

BACKGROUND: Whole-blood (WB) leukoreduction filters in current use retain the majority of PLTs. A new whole-blood filter, which retains significantly fewer of the PLTs (or saves PLTs [WB-SP]), has been developed. The performance characteristics of the WB-SP filter have been evaluated in a multicenter study. STUDY DESIGN AND METHODS: A total of 617 units of WB was collected into quadruple bag sets with an integrated WB-SP filter, leukoreduced, and processed into leukoreduced RBCs (LR-RBC), plasma (LR-PL), and buffy coats (LR-BC) from which, pooled, leukoreduced, PLT concentrates (LR-PCs) were produced. Recovery, yield, and residual WBCs were assessed in prepared blood components. RESULTS: The median residual WBC number in the LR-RBCs was 0.05 x 10(6) (range, <0.05-3.8), exceeding 1 x 10(6) in 0.6 percent of the units. Median Hb content in LR-RBC was 50 g (range, 34-72), reflecting a final RBC recovery of 81 +/- 6 percent. The median WBC content of the LR-PC was 0.05 x 10(6) (range, <0.05-0.28), with none exceeding 1 x 10(6). The median PLT content of the LR-PC, per individual donation, was 6.4 x 10(10) (range, 4.1-10.7), representing a final recovery of 62 +/- 10 percent. The mean FVIII activity was 104 +/- 25 percent and 83 +/- 11 percent in plasma separated from fresh or overnight stored WB, respectively. CONCLUSION: Use of the WB-SP filter makes it possible to obtain three leukoreduced blood components with only one filtration step. The WB-SP filter showed good leukoreduction performance and recovery of all blood components including PLTs.


Asunto(s)
Eliminación de Componentes Sanguíneos/instrumentación , Plaquetas , Filtración/métodos , Leucocitos , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA