Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
EJNMMI Res ; 11(1): 69, 2021 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-34312736

RESUMEN

BACKGROUND: Bronchoscopy serves as direct visualisation of the airway. Virtual bronchoscopy provides similar visual information using a non-invasive imaging procedure(s). Early and accurate image-guided diagnosis requires the possible highest performance, which might be approximated by combining anatomical and functional imaging. This communication describes an advanced functional virtual bronchoscopic (fVB) method based on the registration of PET images to high-resolution diagnostic CT images instead of low-dose CT images of lower resolution obtained from PET/CT scans. PET/CT and diagnostic CT data were collected from 22 oncological patients to develop a computer-aided high-precision fVB. Registration of segmented images was performed using elastix. RESULTS: For virtual bronchoscopy, we used an in-house developed segmentation method. The quality of low- and high-dose CT image registrations was characterised by expert's scoring the spatial distance of manually paired corresponding points and by eight voxel intensity-based (dis)similarity parameters. The distribution of (dis)similarity parameter correlating best with anatomic scoring was bootstrapped, and 95% confidence intervals were calculated separately for acceptable and insufficient registrations. We showed that mutual information (MI) of the eight investigated (dis)similarity parameters displayed the closest correlation with the anatomy-based distance metrics used to characterise the quality of image registrations. The 95% confidence intervals of the bootstrapped MI distribution were [0.15, 0.22] and [0.28, 0.37] for insufficient and acceptable registrations, respectively. In case of any new patient, a calculated MI value of registered low- and high-dose CT image pair within the [0.28, 0.37] or the [0.15, 0.22] interval would suggest acceptance or rejection, respectively, serving as an aid for the radiologist. CONCLUSION: A computer-aided solution was proposed in order to reduce reliance on radiologist's contribution for the approval of acceptable image registrations.

2.
EJNMMI Phys ; 8(1): 28, 2021 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-33738627

RESUMEN

BACKGROUND: Regular and precise inspection of the realization of the local nuclear medicine standard operation procedures (SOPs) is very complex and time-consuming, especially when large amount of patient data is obtained from a wide scale of different scan procedures on a daily basis. DICOM metadata comprise a complete set of data related to the patient and the imaging procedure, and consequently all information necessary to evaluate the compliance with the actual SOP. METHODS: Q-Bot, an automatic DICOM metadata monitoring tool which is capable to verify SOP conformities, was tested for 11 months at two nuclear medicine departments. Relevant parameters, such as patient ID, patient mass and height, injected activity, and uptake time, were investigated in the case of adult 18F-FDG whole-body PET/CT and 99mTc-MDP gamma camera bone scans on a daily basis. Q-Bot automatically inspected the actual SOP compliance of these relevant DICOM parameters. Q-Bot graphical user interface (GUI) provided a summary of the outliers in a table format to be investigated by a dedicated technologist. In addition, information related to the error handling was also collected for retrospective analysis of long-term tendencies. RESULTS: In total, 6702 PET/CT and 2502 gamma camera scans were inspected, from which 8581 were confirmed as valid patient study without errors. Discrepancies related to the lack of a parameter, not appropriate format, or improper scan procedures were found in 623 cases, and 156 out of these were corrected before the medical reading and reporting. SOP non-conformities explored with Q-Bot were found to be non-correctable in 467 cases. Systematic errors to our practice turned out to be the manual radiopharmaceutical injection, the allowance to use both SI and non-SI units, and the clear definition of decimal point symbol to use. CONCLUSION: The daily evaluation of Q-Bot results provided early detection of errors and consequently ensured the minimization of error propagation. Integration of a QM software that inspects protocol compliance at a nuclear medicine department provides significant support to detect non-conformities for technologists, and much higher confidence in image quality for physicians.

3.
Med Dosim ; 45(4): e1-e8, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32505630

RESUMEN

The human brain as an organ has numerous functions; some of them can be visualized by functional imaging techniques (e.g., functional MRI [fMRI] or positron emission tomography). The localization of the appropriate activity clusters requires sophisticated instrumentation and complex measuring protocol. As the inclusion of the activation pattern in modern self-tailored 3D based radiotherapy has notable advantages, this method is applied frequently. Unfortunately, no standardized method has been published yet for the integration of the fMRI data into the planning process and the detailed description of the individual applications is usually missing. Thirteen patients with brain tumors, receiving fMRI based RT planning were enrolled in this study. The delivered dose maps were exported from the treatment planning system and processed for further statistical analysis. Two parameters were introduced to measure the geometrical distance Hausdorff Distance (HD), and volumetric overlap Dice Similarity Coefficient (DSC) of fMRI corrected and not corrected dose matrices as calculated by 3D planning to characterize similarity and/or dissimilarity of these dose matrices. Statistical analysis of bootstrapped HD and DSC data was performed to determine confidence intervals of these parameters. The calculated confidence intervals for HD and DSC were (5.04, 7.09), (0.79, 0.86), respectively for the 40 Gy and (5.2, 7.85), (0.74, 0.83), respectively for the 60 Gy dose volumes. These data indicate that in the case of HD < 5.04 and/or DSC > 0.86, the 40 Gy dose volumes obtained with and without fMRI activation pattern do not show a significant difference (5% significance level). The same conditions for the 60 Gy dose volumes were HD < 5.2 and/or DSC > 0.83. At the same time, with HD > 7.09 and/or DSC < 0.79 for 40 Gy and HD > 7.85 and/or DSC < 0.74 for 60 Gy the impact of fMRI utilization in RT planning is excessive. The fMRI activation clusters can be used in daily RT planning routine to spare activation clusters as critical areas in the brain and avoid their high dose irradiation. Parameters HD (as distance) and DSC (as overlap) can be used to characterize the difference and similarity between the radiotherapy planning target volumes and indicate whether the fMRI delivered activation patterns and consequent fMRI corrected planning volumes are reliable or not.


Asunto(s)
Radioterapia Conformacional , Radioterapia de Intensidad Modulada , Mapeo Encefálico , Humanos , Imagen por Resonancia Magnética , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
4.
PLoS One ; 14(1): e0207658, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30682024

RESUMEN

The aim of this work was to develop a novel phantom that supports the construction of highly reproducible phantoms with arbitrary activity distributions for PET imaging. It could offer a methodology for answering questions related to texture measurements in PET imaging. The basic idea is to move a point source on a 3-D trajectory in the field of view, while continuously acquiring data. The reconstruction results in a 3-D activity concentration map according to the pathway of the point source. A 22Na calibration point source was attached to a high precision robotic arm system, where the 3-D movement was software controlled. 3-D activity distributions of a homogeneous cube, a sphere, a spherical shell and a heart shape were simulated. These distributions were used to measure uniformity and to characterize reproducibility. Two potential applications using the lesion simulation method are presented: evaluation in changes of textural properties related to the position in the PET field of view; scanner comparison based on visual and quantitative evaluation of texture features. A lesion with volume of 50x50x50 mm3 can be simulated during approximately 1 hour. The reproducibility of the movement was found to be >99%. The coefficients of variation of the voxels within a simulated homogeneous cube was 2.34%. Based on 5 consecutive and independent measurements of a 36 mm diameter hot sphere, the coefficient of variation of the mean activity concentration was 0.68%. We obtained up to 18% differences within the values of investigated textural indexes, when measuring a lesion in different radial positions of the PET field of view. In comparison of two different human PET scanners the percentage differences between heterogeneity parameters were in the range of 5-55%. After harmonizing the voxel sizes this range reduced to 2-16%. The general activity distributions provided by the two different vendor show high similarity visually. For the demonstration of the flexibility of this method, the same pattern was also simulated on a small animal PET scanner giving similar results, both quantitatively and visually. 3-D motion of a point source in the PET field of view is capable to create an irregular shaped activity distribution with high reproducibility.


Asunto(s)
Fantasmas de Imagen , Tomografía de Emisión de Positrones , Humanos , Imagenología Tridimensional , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X
5.
PLoS One ; 11(10): e0164113, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27736888

RESUMEN

Textural analysis might give new insights into the quantitative characterization of metabolically active tumors. More than thirty textural parameters have been investigated in former F18-FDG studies already. The purpose of the paper is to declare basic requirements as a selection strategy to identify the most appropriate heterogeneity parameters to measure textural features. Our predefined requirements were: a reliable heterogeneity parameter has to be volume independent, reproducible, and suitable for expressing quantitatively the degree of heterogeneity. Based on this criteria, we compared various suggested measures of homogeneity. A homogeneous cylindrical phantom was measured on three different PET/CT scanners using the commonly used protocol. In addition, a custom-made inhomogeneous tumor insert placed into the NEMA image quality phantom was imaged with a set of acquisition times and several different reconstruction protocols. PET data of 65 patients with proven lung lesions were retrospectively analyzed as well. Four heterogeneity parameters out of 27 were found as the most attractive ones to characterize the textural properties of metabolically active tumors in FDG PET images. These four parameters included Entropy, Contrast, Correlation, and Coefficient of Variation. These parameters were independent of delineated tumor volume (bigger than 25-30 ml), provided reproducible values (relative standard deviation< 10%), and showed high sensitivity to changes in heterogeneity. Phantom measurements are a viable way to test the reliability of heterogeneity parameters that would be of interest to nuclear imaging clinicians.


Asunto(s)
Fluorodesoxiglucosa F18/análisis , Neoplasias Pulmonares/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Radiofármacos/análisis , Humanos , Pulmón/patología , Neoplasias Pulmonares/patología , Fantasmas de Imagen , Reproducibilidad de los Resultados , Estudios Retrospectivos , Carga Tumoral
6.
Z Med Phys ; 25(4): 353-367, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26279292

RESUMEN

BACKGROUND: Clinical practice often requires simultaneous information obtained by two different imaging modalities. Registration algorithms are commonly used for this purpose. Automated procedures are very helpful in cases when the same kind of registration has to be performed on images of a high number of subjects. Radiotherapists would prefer to use the best automated method to assist therapy planning, however there are not accepted procedures for ranking the different registration algorithms. PURPOSE: We were interested in developing a method to measure the population level performance of CT-MRI registration algorithms by a parameter of values in the [0,1] interval. MATERIALS AND METHODS: Pairs of CT and MRI images were collected from 1051 subjects. Results of an automated registration were corrected manually until a radiologist and a neurosurgeon expert both accepted the result as good. This way 1051 registered MRI images were produced by the same pair of experts to be used as gold standards for the evaluation of the performance of other registration algorithms. Pearson correlation coefficient, mutual information, normalized mutual information, Kullback-Leibler divergence, L1 norm and square L2 norm (dis)similarity measures were tested for sensitivity to indicate the extent of (dis)similarity of a pair of individual mismatched images. RESULTS: The square Hellinger distance proved suitable to grade the performance of registration algorithms at population level providing the developers with a valuable tool to rank algorithms. CONCLUSIONS: The developed procedure provides an objective method to find the registration algorithm performing the best on the population level out of newly constructed or available preselected ones.


Asunto(s)
Algoritmos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Radioterapia Guiada por Imagen/métodos , Técnica de Sustracción , Tomografía Computarizada por Rayos X/métodos , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
7.
Appl Radiat Isot ; 94: 77-81, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25113536

RESUMEN

Excel2Genie, a simple and user-friendly Microsoft Excel interface, has been developed to the Genie-2000 Spectroscopic Software of Canberra Industries. This Excel application can directly control Canberra Multichannel Analyzer (MCA), process the acquired data and visualize them. Combination of Genie-2000 with Excel2Genie results in remarkably increased flexibility and a possibility to carry out repetitive data acquisitions even with changing parameters and more sophisticated analysis. The developed software package comprises three worksheets: display parameters and results of data acquisition, data analysis and mathematical operations carried out on the measured gamma spectra. At the same time it also allows control of these processes. Excel2Genie is freely available to assist gamma spectrum measurements and data evaluation by the interested Canberra users. With access to the Visual Basic Application (VBA) source code of this application users are enabled to modify the developed interface according to their intentions.


Asunto(s)
Algoritmos , Bases de Datos Factuales , Almacenamiento y Recuperación de la Información/métodos , Lenguajes de Programación , Programas Informáticos , Espectrometría gamma/métodos , Interfaz Usuario-Computador , Sistemas de Administración de Bases de Datos , Diseño de Software , Validación de Programas de Computación , Espectrometría gamma/instrumentación
8.
Phys Med Biol ; 59(11): 2727-46, 2014 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-24800813

RESUMEN

The contrast recovery coefficients (CRC) were evaluated for five different small animal PET scanners: GE Explore Vista, Genisys4, MiniPET-2, nanoScan PC and Siemens Inveon. The NEMA NU-4 2008 performance test with the suggested image quality phantom (NU4IQ) does not allow the determination of the CRC values for the hot regions in the phantom. This drawback of NU4IQ phantom motivated us to develop a new method for this purpose. The method includes special acquisition and reconstruction protocols using the original phantom, and results in an artificially merged image enabling the evaluation of CRC values. An advantageous feature of this method is that it stops the cold wall effect from distorting the CRC calculation. Our suggested protocol results in a set of CRC values contributing to the characterization of small animal PET scanners. GATE simulations were also performed to validate the new method and verify the evaluated CRC values. We also demonstrated that the numerical values of this parameter depend on the actual object contrast of the hot region(s) and this mainly comes from the spillover effect. This effect was also studied while analysing the background activity level around the hot rods. We revealed that the calculated background mean values depended on the target contrast in a scanner specific manner. Performing the artificially merged imaging procedure and additional simulations using the micro hollow sphere (MHS) phantom geometry, we also proved that the inactive wall around the hot spheres can have a remarkable impact on the calculated CRC. In conclusion, we have shown that the proposed artificial merging procedure and the commonly used NU4IQ phantom prescribed by the NEMA NU-4 can easily deliver reliable CRC data otherwise unavailable for the NU4IQ phantom in the conventional protocol or the MHS phantom.


Asunto(s)
Frío , Fantasmas de Imagen , Tomografía de Emisión de Positrones/instrumentación , Animales , Artefactos , Método de Montecarlo
9.
Orv Hetil ; 150(47): 2133-8, 2009 Nov 22.
Artículo en Húngaro | MEDLINE | ID: mdl-19910278

RESUMEN

UNLABELLED: In the past few decades Hodgkin lymphoma (HL) has become a highly curable malignant disease, as a result of using modern polychemotherapy and irradiation. Differentiation of active tumor from fibrosis or necrosis within residual radiographic masses represents a problem of interpretation. AIMS: The aim of this retrospective study is to assess the value of FDG-PET for prediction of remission or relapse in HL. PATIENTS AND METHODS: Data of 128 patients, who had residual masses on CT after completion of their planned treatment, have been analyzed. FDG-PET was performed between January 1995 and February 2005. RESULTS: The median duration of the follow-up from PET was 75.5 months (range: 20-180 months). 89 (70%) patients had negative and 39 (30%) patients had positive FDG-PET results. The numbers of true-positive, true-negative, false-positive and false-negative subjects were 29, 83, 10 and 6, respectively. Sensitivity of post-treatment FDG-PET was 83%, specificity 93%, positive predictive value 74%, negative predictive value 93%, and accuracy 88%. The difference between the event free survival of PET positive and negative cases is highly significant (p = 0.0000), according to the Mantel-Cox test. CONCLUSION: Our results, in accordance with literature, clearly indicate that patients with negative FDG-PET results are unlikely to progress or relapse during a long follow-up. However, false positive uptake is a problem. We have investigated the effect of age, histological subtype, clinical stage and the type of treatment on the accuracy, but on the basis of these facts we could not find any significant difference. However, the date of the investigation influenced the results: before 2000 the number of false results was significantly higher than after that time, which shows the importance of investigators' experience.


Asunto(s)
Fluorodesoxiglucosa F18 , Enfermedad de Hodgkin/diagnóstico por imagen , Tomografía de Emisión de Positrones , Adolescente , Adulto , Anciano , Reacciones Falso Negativas , Reacciones Falso Positivas , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Tomografía de Emisión de Positrones/métodos , Valor Predictivo de las Pruebas , Pronóstico , Radiofármacos , Recurrencia , Inducción de Remisión , Estudios Retrospectivos , Factores de Tiempo , Adulto Joven
10.
Appl Radiat Isot ; 67(10): 1806-11, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19674913

RESUMEN

We studied how very short (10-40min) incubation with anthracycline derivatives modifies the accumulation of PET tumor-diagnostic radiotracers in cancer cells. The human ovarian A2780 and A2780AD, human B lymphoid JY, human epidermoid KB-3-1 and KB-V-1, and smooth muscle DDT1 MF-2 cells were pre-incubated with daunorubicin and doxorubicin, and the uptake of [(18)F]FDG and [(11)C]choline was measured. Anthracycline treatment decreased remarkably the [(11)C]choline accumulation in a concentration dependent manner, while it did not modify significantly the [(18)F]FDG uptake of the cells.


Asunto(s)
Colina/metabolismo , Daunorrubicina/farmacología , Doxorrubicina/farmacología , Radioisótopos de Carbono , Línea Celular Tumoral , Fluorodesoxiglucosa F18 , Humanos
11.
J Neuroimaging ; 19(3): 253-8, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19021848

RESUMEN

BACKGROUND AND PURPOSE The antiakinetic effect of internal Globus pallidus deep brain stimulation (Gpi-DBS) in Parkinson's disease is not clear and not either how this effect is modulated by L-dopa. METHODS Left Gpi-DBS and/or L-dopa effect was studied with auditory paced right-handed sequential movements on (15)O-butanol positron emission tomography (PET) in five patients. Rest and for conditions during movements (DBS off/L-dopa off; DBS on/L-dopa off; DBS off/L-dopa on; DBS on/L-dopa on) were compared with statistical parametric mapping. RESULTS Gpi-DBS activated the right supplementary motor area/premotor (SMA/PMC), and right insular cortex (IC), and as L-dopa decreased the left sensorimotor cortex (M1/S1) activity. L-dopa increased the left ventrolateral thalamus (VLTH), and decreased the left superior parietal cortex (PC) activity. Gpi-DBS and L-dopa interaction showed right SMA/PMC, IC, and left PC activation, decrease of left VLTH, PMC, and dorsolateral prefrontal cortex (PFC) activity. CONCLUSIONS The improvement of bradykinesia with Gpi-DBS is secondary and contributed to the regress of M1/S1-related rigidity and compensatory SMA/PMC, and IC activation. L-dopa and Gpi-DBS alone each reduces M1/S1 overactivity. Interaction ignores this effect, moreover has akinetic effect in the left VLTH, PMC, and PFC. Motor improvement possibly related to left PC and compensatory right SMA/PMC, and IC activation.


Asunto(s)
Antiparkinsonianos/uso terapéutico , Encéfalo/diagnóstico por imagen , Estimulación Encefálica Profunda , Levodopa/uso terapéutico , Enfermedad de Parkinson/terapia , Análisis de Varianza , Encéfalo/fisiopatología , Mapeo Encefálico , Butanoles , Progresión de la Enfermedad , Femenino , Globo Pálido/diagnóstico por imagen , Globo Pálido/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Actividad Motora/efectos de los fármacos , Actividad Motora/fisiología , Radioisótopos de Oxígeno , Enfermedad de Parkinson/diagnóstico por imagen , Enfermedad de Parkinson/tratamiento farmacológico , Tomografía de Emisión de Positrones , Tiempo de Reacción , Análisis y Desempeño de Tareas
12.
Circ Cardiovasc Imaging ; 1(2): 94-103, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19808526

RESUMEN

BACKGROUND: Porcine bone marrow-derived mesenchymal stem cells (MSCs) were stably transfected with a lentiviral vector for transgene expression of the trifusion protein renilla luciferase, red fluorescent protein and herpes simplex truncated thymidine kinase (LV-RL-RFP-tTK; positron emission tomography [PET] reporter gene) for in vivo noninvasive tracking of the intramyocardially delivered MSC fate. METHODS AND RESULTS: A closed-chest, reperfused myocardial infarction was created in farm pigs. Sixteen days after myocardial infarction, LV-RL-RFP-tTK-MSCs were injected intramyocardially using electromechanical mapping guidance in the infarct border zone (n=7). PET-computed tomographic metabolic and perfusion imaging was performed after an intravenous injection of 10 mCi [18F]-FHBG and 13N-ammonia PET at 30+/-2 hours and 7 days after LV-RL-RFP-tTK-MSC treatment. Fusion imaging of the [18F]-FHBG PET-computed tomography with MRI was used to determine the myocardial location of the injected LV-RL-RFP-tTK-MSCs. Seven days after injections, [18F]-FHBG PET showed a decreased cardiac uptake with a mild increased pericardial and pleura uptake in the treated animals, which was confirmed by the measurement of luciferase activity. At 10 days, infarct size by MRI in the LV-RL-RFP-tTK-MSC-treated animals was smaller than controls (n=7) (23.3+/-1.5% versus 30.2+/-3.5%, P<0.005). The presence of the LV-RL-RFP-tTK-MSCs (5.8+/-1.1% of the injected cells) in the myocardium 10 days after intramyocardial delivery was confirmed histologically. CONCLUSIONS: Reporter gene imaging enables the tracking of the persistence of viable LV-RL-RFP-tTK-MSC in the peri-infarcted porcine myocardium at 10 days after delivery using clinical PET scanners.


Asunto(s)
Expresión Génica , Genes Reporteros , Corazón/diagnóstico por imagen , Trasplante de Células Madre Mesenquimatosas , Infarto del Miocardio/terapia , Tomografía de Emisión de Positrones , Transfección , Transgenes , Animales , Radioisótopos de Flúor , Guanina/análogos & derivados , Inyecciones , Imagen por Resonancia Magnética , Infarto del Miocardio/patología , Miocardio/patología , Sus scrofa
14.
Eur J Pharm Sci ; 30(1): 56-63, 2007 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-17125978

RESUMEN

AIM: To establish the effects of Na(+)/Ca(2+) exchanger (NCX) blockers on 2-[(18)F]fluoro-2-deoxy-D-glucose ((18)FDG) and (11)C-choline accumulation in different cancer cells. METHODS: The tumor cells were incubated with NCX inhibitors, and the uptakes of (18)FDG and (11)C-choline were measured. Flow cytometric measurements of intracellular Ca(2+) and Na(+) concentrations were carried out. The presence of the NCX antigen in the cancer cells was proved by Western blotting, flow cytometry and confocal laser scanning microscopy. RESULTS: The NCX is expressed at a noteworthy level in the cytosol and on the cytoplasmic membrane of the examined cells. Incubation of the cells with three chemically unrelated NCX blockers (bepridil, KB-R7943 or 3',4'-dichlorobenzamil hydrochloride) resulted in an increase in the intracellular Ca(2+) concentration, with a simultaneous decrease in the intracellular Na(+) concentration. The treatment with the NCX inhibitors increased the energy consumption of the tumor cells by 50-100%. Thapsigargin abolished the NCX-induced (18)FDG accumulation in the cells. The NCX blockers applied decreased the (11)C-choline accumulation of all the investigated cancer cells by 60-80% relative to the control. CONCLUSION: A possible masking effect of NCX medication must be taken into consideration during the diagnostic interpretation of PET scans.


Asunto(s)
Colina/farmacocinética , Fluorodesoxiglucosa F18/farmacocinética , Tomografía de Emisión de Positrones , Intercambiador de Sodio-Calcio/antagonistas & inhibidores , Bepridil/farmacología , Calcio/metabolismo , Radioisótopos de Carbono , Línea Celular Tumoral , Citometría de Flujo , Humanos , Microscopía Confocal , Microscopía Fluorescente , Neoplasias/diagnóstico , Neoplasias/metabolismo , Trazadores Radiactivos , Sodio/metabolismo , Intercambiador de Sodio-Calcio/biosíntesis , Tapsigargina/farmacología
16.
Eur J Pharm Sci ; 28(3): 249-56, 2006 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16574387

RESUMEN

AIM: To study how paclitaxel treatment modifies the accumulation of tumor-diagnostic radiotracers in P-glycoprotein (P-gp) positive and negative cancer cells. METHODS: The accumulations of different P-gp substrates, including rhodamine 123, daunorubicin and [(99m)Tc]hexakis-2-methoxybutyl isonitrile ((99m)Tc-MIBI), were measured in P-gp-positive (A2780AD) and P-gp-negative human ovarian carcinoma cells (A2780) and JY human lymphoid B cells. The uptakes of the tumor-diagnostic tracers (11)C-choline and 2-[(18)F]fluoro-2-deoxy-d-glucose ((18)FDG) were measured in the same cell lines. The P-gp expression and function were demonstrated by flow-cytometry. RESULTS: The (18)FDG measurements revealed that the glucose metabolic rate was significantly higher (p<0.01) in the P-gp-positive A2780AD cells than in the P-gp-negative cells. Paclitaxel (1-70microM) increased the (18)FDG uptake (up to 200%) of both P-gp-positive and P-gp-negative cells, whereas it did not modulate their (11)C-choline uptake. Paclitaxel reinstated the (99m)Tc-MIBI accumulation of the A2780AD cells (to 1500% of the control) in a concentration-dependent manner, while it increased the uptake of the P-gp-negative cells to a lesser extent (to a maximum of 200% of the control). CONCLUSION: Paclitaxel modifies the uptake of tumor-diagnostic tracers in both P-gp-dependent and independent manners. Interpretation of the multifactorial effects of paclitaxel may promote a correct in vivo diagnosis of P-gp-positive and P-gp-negative tumors.


Asunto(s)
Miembro 1 de la Subfamilia B de Casetes de Unión a ATP/metabolismo , Antineoplásicos Fitogénicos/metabolismo , Paclitaxel/metabolismo , Radiofármacos/metabolismo , Sitios de Unión , Transporte Biológico , Línea Celular Tumoral/metabolismo , Resistencia a Antineoplásicos , Fluorodesoxiglucosa F18/metabolismo , Humanos , Cinética , Unión Proteica , Trazadores Radiactivos , Tecnecio Tc 99m Sestamibi/metabolismo
17.
Pediatr Neurol ; 34(4): 270-5, 2006 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-16638500

RESUMEN

Resting cerebral glucose metabolism was assessed by 18[F]-fluorodeoxyglucose in 11 Down syndrome patients. Standardized uptake values were determined on a pixel-by-pixel basis from the measured tissue-activity data. The results revealed a mean overall 18[F]-fluorodeoxyglucose uptake in the Down syndrome patients close to that observed in the control group, consisting of children and young adults. However, the standard deviation of the standardized uptake values was much higher in the Down syndrome group in almost all voxels relating to the gray matter. The statistical parametric mapping method was applied to compare the cerebral 18[F]-fluorodeoxyglucose accumulation patterns of the Down syndrome and control groups. Six regions (clusters) were found for which the glucose uptake was higher in the Down syndrome patients than in the control group. The anatomic localization of these clusters was based on magnetic resonance investigations and a brain-atlas technique. The localization of the identified clusters with an increased glucose metabolism in the Down syndrome patients suggests that these subjects have an enhanced resting neuronal activity in cortical areas involved in reasoning, cognition, and speech as compared with normal subjects.


Asunto(s)
Síndrome de Down/metabolismo , Glucosa/metabolismo , Telencéfalo/metabolismo , Adolescente , Adulto , Estudios de Casos y Controles , Niño , Preescolar , Síndrome de Down/diagnóstico por imagen , Femenino , Fluorodesoxiglucosa F18/farmacocinética , Humanos , Masculino , Tomografía de Emisión de Positrones , Radiofármacos/farmacocinética , Descanso/fisiología , Telencéfalo/diagnóstico por imagen
18.
Artículo en Inglés | MEDLINE | ID: mdl-16410035

RESUMEN

OBJECTIVE: Cognitive deficit is an essential feature of schizophrenia. One of the generally used simple cognitive tasks to characterize specific cognitive dysfunctions is the auditory "oddball" paradigm. During this task, two different tones are presented with different repetition frequencies and the subject is asked to pay attention and to respond to the less frequent tone. The aim of the present study was to apply positron emission tomography (PET) to measure the regional brain blood flow changes induced by an auditory oddball task in healthy volunteers and in stable schizophrenic patients in order to detect activation differences between the two groups. METHOD: Eight healthy volunteers and 11 schizophrenic patients were studied. The subjects carried out a specific auditory oddball task, while cerebral activation measured via the regional distribution of [15O]-butanol activity changes in the PET camera was recorded. RESULTS AND DISCUSSION: Task-related activation differed significantly across the patients and controls. The healthy volunteers displayed significant activation in the anterior cingulate area (Brodman Area - BA32), while in the schizophrenic patients the area was wider, including the mediofrontal regions (BA32 and BA10). The distance between the locations of maximal activation of the two populations were 33 mm and the cluster size was about twice as large in the patient group. CONCLUSIONS: The present results demonstrate that the perfusion changes induced in the schizophrenic patients by this cognitive task extends over a larger part of the mediofrontal cortex than in the healthy volunteers. The different pattern of activation observed during the auditory oddball task in the schizophrenic patients suggests that a larger cortical area - and consequently a larger variety of neuronal networks--is involved in the cognitive processes in these patients. The dispersion of stimulus processing during a cognitive task requiring sustained attention and stimulus discrimination may play an important role in the pathomechanism of the disorder.


Asunto(s)
Encéfalo/irrigación sanguínea , Tomografía de Emisión de Positrones , Flujo Sanguíneo Regional/fisiología , Esquizofrenia/fisiopatología , Estimulación Acústica/métodos , Adulto , Encéfalo/fisiopatología , Electroencefalografía , Potenciales Evocados/fisiología , Femenino , Humanos , Masculino , Pruebas Neuropsicológicas/estadística & datos numéricos
19.
Cell Motil Cytoskeleton ; 63(2): 66-76, 2006 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-16374831

RESUMEN

A number of cell functions, such as flagellar beating, swimming velocity, acrosome reaction, etc., are triggered by a Ca2+ influx across the cell membrane. For appropriate physiological functions, the motile human sperm maintains the intracellular free calcium concentration ([Ca2+]i) at a submicromolar level. The objective of this study was to determine the role of the Na+/Ca2+ exchanger (NCX) in the maintenance of [Ca2+]i in human spermatozoa. Spermatozoa maintained in extracellular medium containing>or=1 microM Ca2+ exhibited motility similar to that of the control. In addition to several calcium transport mechanisms described earlier, we provide evidence that the NCX plays a crucial role in the maintenance of [Ca2+]i. Three chemically unrelated inhibitors of the NCX (bepridil, DCB (3',4'-dichlorobenzamil hydrochloride), and KB-R7943) all blocked human sperm motility in a dose and incubation time dependent manner. The IC50 values for bepridil, DCB, and KB-R7943 were 16.2, 9.8, and 5.3 microM, respectively. The treatment with the above-mentioned blockers resulted in an elevated [Ca2+]i and a decreased [Na+]i. The store-operated calcium channel (SOCC) inhibitor SKF 96365 also blocked the sperm motility (IC50=2.44 microM). The presence of the NCX antigen in the human spermatozoa was proven by flow cytometry, confocal laser scanning microscopy, and immunoblotting techniques. Calcium homeostasis of human spermatozoa is maintained by several transport proteins among which the SOCC and the NCX may play a major role.


Asunto(s)
Calcio/metabolismo , Homeostasis/fisiología , Intercambiador de Sodio-Calcio/metabolismo , Motilidad Espermática/fisiología , Bepridil/farmacología , Bloqueadores de los Canales de Calcio/farmacología , Canales de Calcio/efectos de los fármacos , Canales de Calcio/metabolismo , Relación Dosis-Respuesta a Droga , Inhibidores Enzimáticos/farmacología , Citometría de Flujo , Homeostasis/efectos de los fármacos , Humanos , Masculino , Potenciales de la Membrana/efectos de los fármacos , Microscopía Confocal , Intercambiador de Sodio-Calcio/efectos de los fármacos , Motilidad Espermática/efectos de los fármacos , Espermatozoides/efectos de los fármacos , Espermatozoides/metabolismo , Espermatozoides/ultraestructura , Tapsigargina/farmacología , Tiourea/análogos & derivados , Tiourea/farmacología
20.
Neurol Res ; 28(8): 864-70, 2006 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-17288747

RESUMEN

OBJECTIVES: The aim was to elucidate whether aneurysmal subarachnoid hemorrhage (SAH)-induced vasospasm induces changes of regional glucose uptake in surgically treated, asymptomatic cases. METHODS: (18)FDG uptake (standardized uptake value, SUV) was analysed with PET in eight surgically treated aneurismal patients with a mean middle cerebral artery flow velocity >120 cm/seconds measured with transcranial Doppler ultrasound. Data were compared with a healthy control group using Statistical Parametric Mapping (SPM99b). RESULTS: Six of the eight patients had no focal neurological signs. The inhomogeneous bilateral increase in SUV (p<0.0001) was asymmetrical, with an almost 70% larger volume on the operated side. Reduced glucose uptake was found in the frontal and temporobasal regions of the two patients with neurological deficits (p<0.0001); the affected volume was 40% larger on the operated side. DISCUSSION: SAH-induced vasospasm results in widespread increase of glucose uptake-probably reflecting increased glycolysis. This was earlier than neurological focal signs appear. Decreased glucose uptake can be detected in severe cases of vasospasm reflected by neurological deficit. Although the changes are more prominent where surgery had taken place our results suggest that not only the surgery, but also subarachnoid blood might have resulted in our findings.


Asunto(s)
Fluorodesoxiglucosa F18/metabolismo , Vasoespasmo Intracraneal/diagnóstico por imagen , Adulto , Mapeo Encefálico , Diagnóstico por Computador , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tomografía de Emisión de Positrones , Hemorragia Subaracnoidea/complicaciones , Vasoespasmo Intracraneal/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...