Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Bioengineering (Basel) ; 10(10)2023 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-37892868

RESUMEN

This study aims to highlight recent research work on topics around prosthetic feet through a scientometric analysis and historical review. The most cited publications from the Clarivate Analytics Web of Science Core Collection database were identified and analyzed from 1 January 2000 to 31 October 2022. Original articles, reviews with full manuscripts, conference proceedings, early access documents, and meeting abstracts were included. A scientometric visualization analysis of the bibliometric information related to the publications, including the countries, institutions, journals, references, and keywords, was conducted. A total of 1827 publications met the search criteria in this study. The related publications grouped by year show an overall trend of increase during the two decades from 2000 to 2022. The United States is ranked first in terms of overall influence in this field (n = 774). The Northwestern University has published the most papers on prosthetic feet (n = 84). Prosthetics and Orthotics International has published the largest number of studies on prosthetic feet (n = 151). During recent years, a number of studies with citation bursts and burst keywords (e.g., diabetes, gait, pain, and sensor) have provided clues on the hotspots of prosthetic feet and prosthetic foot trends. The findings of this study are based on a comprehensive analysis of the literature and highlight the research topics on prosthetic feet that have been primarily explored. The data provide guidance to clinicians and researchers to further studies in this field.

2.
Gait Posture ; 90: 283-288, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34537497

RESUMEN

BACKGROUND: Hallux valgus orthoses are available in a wide range of designs and materials, but the effects of their design on functional performance have not been fully investigated. RESEARCH QUESTION: This present study aims to comprehensively analyze the immediate effects of soft and semi-rigid hallux valgus orthoses on balance, plantar pressure, hallux valgus angle, and subjective sensations. METHODS: Sixteen female subjects have participated in the study, including 10 subjects with healthy feet and 6 with hallux valgus. Three conditions are tested, including in the barefoot and using two types of commercially available hallux valgus orthoses. The subjects participate in static and dynamic (walking) tests with the use of the Novel Pedar® system. The peak pressure values in the hallux, lateral toes, first metatarsophalangeal joint, 2-4th metatarsal heads, 5th metatarsal head, medial midfoot, lateral midfoot and rearfoot in the various foot conditions are examined and compared. The hallux valgus angle of each subject is measured based on their footprint. Their subjective feelings towards the orthoses are also evaluated. A repeated-measures analysis of variance, and independent-sample t-test are performed. RESULTS: The correction of the hallux valgus angle is statistically significant when the subjects with hallux valgus use the orthoses. In comparing the two types of orthoses, the use of the orthosis made of soft materials results in correction in the hallux valgus angle and higher wear comfort, and lower plantar pressure in hallux area. SIGNIFICANCE: The results provide insights into the design of hallux valgus orthoses, thus offering practical reference for the selection of hallux valgus orthosis with compromise between functional performance and wear comfort.


Asunto(s)
Hallux Valgus , Huesos Metatarsianos , Femenino , Pie , Humanos , Aparatos Ortopédicos , Presión
3.
BMJ Open ; 11(8): e047273, 2021 08 18.
Artículo en Inglés | MEDLINE | ID: mdl-34408037

RESUMEN

OBJECTIVE: The treatment effect of orthoses for hallux valgus (HV) is unclear with little interventional studies, the design involves multiple complex factors, and therefore a systematic analysis with meta-analysis is necessary. The objective of this systematic review and meta-analysis is to determine whether current foot orthoses are effective in treating HV. DESIGN: Systematic review with meta-analysis. DATA SOURCES: Electronic databases (PubMed, Scopus, Cinahl and Medline) are searched up to February 2020. ELIGIBILITY CRITERIA FOR SELECTING STUDIES: Interventional studies with content focus on HV orthosis design and any of the outcomes related to effectiveness for treating HV are included. The standardised mean differences are calculated. The risk of bias in included studies is assessed using the Cochrane Collaboration's risk of bias tools. RESULTS: In total, 2066 articles are identified. Among them, nine are selected and quality rated, and data are extracted and closely examined. A meta-analysis is conducted, where appropriate. The main causes of potential bias are missing outcome data and outcome measurement error. The results show that orthosis with a toe separator has the best effect of correcting the HV angle (standardised mean difference: 0.50, 95% CI: 0.189 to 0.803). CONCLUSION: The orthoses design with a toe separator or an element that allows for the foot anatomic alignment is critical for reducing the HV angle and relieving foot pain. The results contribute to a better selection of treatment for patients. PROSPERO REGISTRATION NUMBER: CRD42021260403.


Asunto(s)
Ortesis del Pié , Hallux Valgus , Tirantes , Pie , Hallux Valgus/terapia , Humanos , Calidad de Vida
4.
Ann Biomed Eng ; 46(8): 1194-1205, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29691786

RESUMEN

Smart materials have attracted considerable attention in the medical field. In particular, shape memory alloys (SMAs) are most commonly utilized for their superelasticity (SE) in orthopaedic treatment. In this study, the resin struts of a flexible brace for adolescent idiopathic scoliosis (AIS) are replaced with different conventional materials and an SMA. The corrective mechanism mainly depends on the compressive force applied by the brace at the desired location. Therefore, the mechanical properties of the materials used and the interface pressure are both critical factors that influence the treatment effectiveness. The results indicate that titanium is the most rigid among the five types of materials, whereas the brace with SMA struts presents the best recovery properties and the most stable interface pressure. A radiographic examination of two patients with AIS is then conducted to validate the results, which shows that the SMA struts can provide better correction of thoracic curvature. These findings suggest that SMAs can be applied in orthoses because their SE allows for continuous and controllable corrective forces.


Asunto(s)
Aleaciones , Tirantes , Elasticidad , Escoliosis/diagnóstico por imagen , Escoliosis/terapia , Tomografía Computarizada por Rayos X , Adolescente , Femenino , Humanos
5.
Sci Rep ; 7(1): 14431, 2017 10 31.
Artículo en Inglés | MEDLINE | ID: mdl-29089528

RESUMEN

Adolescent idiopathic scoliosis (AIS) is a multifactorial, three-dimensional deformity of the spine and trunk. School scoliosis screening (SSS) is recommended by researchers as a means of early detection of AIS to prevent its progression in school-aged children. The traditional screening technique for AIS is the forward bending test because it is simple, non-invasive and inexpensive. Other tests, such as the use of Moiré topography, have reduced the high false referral rates. The use of infrared (IR) thermography for screening purposes based on the findings of previous studies on the asymmetrical paraspinal muscle activity of scoliotic patients compared with non-scoliotic subjects was explored in this study. IR thermography is performed with an IR camera to determine the temperature differences in paraspinal muscle activity. A statistical analysis showed that scoliotic subjects demonstrate a statistically significant difference between the left and right sides of the regions of interest. This difference could be due to the higher IR emission of the convex side of the observed area, thereby creating a higher temperature distribution. The findings of this study suggest the feasibility of incorporating IR thermography as part of SSS. However, future studies could also consider a larger sample of both non-scoliotic and scoliotic subjects to further validate the findings.


Asunto(s)
Escoliosis/diagnóstico por imagen , Adolescente , Niño , Programas de Detección Diagnóstica , Progresión de la Enfermedad , Electromiografía , Femenino , Humanos , Cifosis , Masculino , Tamizaje Masivo , Músculo Esquelético , Postura/fisiología , Columna Vertebral , Termografía/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...