Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Diagnostics (Basel) ; 11(11)2021 Nov 12.
Artículo en Inglés | MEDLINE | ID: mdl-34829438

RESUMEN

The correct differential diagnosis of dementia has an important impact on patient treatment and follow-up care strategies. Tc-99m-ECD SPECT imaging, which is low cost and accessible in general clinics, is used to identify the two common types of dementia, Alzheimer's disease (AD) and Lewy body dementia (LBD). Two-stage transfer learning technology and reducing model complexity based on the ResNet-50 model were performed using the ImageNet data set and ADNI database. To improve training accuracy, the three-dimensional image was reorganized into three sets of two-dimensional images for data augmentation and ensemble learning, then the performance of various deep learning models for Tc-99m-ECD SPECT images to distinguish AD/normal cognition (NC), LBD/NC, and AD/LBD were investigated. In the AD/NC, LBD/NC, and AD/LBD tasks, the AUC values were around 0.94, 0.95, and 0.74, regardless of training models, with an accuracy of 90%, 87%, and 71%, and F1 scores of 89%, 86%, and 76% in the best cases. The use of transfer learning and a modified model resulted in better prediction results, increasing the accuracy by 32% for AD/NC. The proposed method is practical and could rapidly utilize a deep learning model to automatically extract image features based on a small number of SPECT brain perfusion images in general clinics to objectively distinguish AD and LBD.

2.
Ann Nucl Med ; 35(8): 889-899, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34076857

RESUMEN

OBJECTIVE: To develop a practical method to rapidly utilize a deep learning model to automatically extract image features based on a small number of SPECT brain perfusion images in general clinics to objectively evaluate Alzheimer's disease (AD). METHODS: For the properties of low cost and convenient access in general clinics, Tc-99-ECD SPECT imaging data in brain perfusion detection was used in this study for AD detection. Two-stage transfer learning based on the Inception v3 network model was performed using the ImageNet dataset and ADNI database. To improve training accuracy, the three-dimensional image was reorganized into three sets of two-dimensional images for data augmentation and ensemble learning. The effect of pre-training parameters for Tc-99m-ECD SPECT image to distinguish AD from normal cognition (NC) was investigated, as well as the effect of the sample size of F-18-FDG PET images used in pre-training. The same model was also fine-tuned for the prediction of the MMSE score from the Tc-99m-ECD SPECT image. RESULTS: The AUC values of w/wo pre-training parameters for Tc-99m-ECD SPECT image to distinguish AD from NC were 0.86 and 0.90. The sensitivity, specificity, precision, accuracy, and F1 score were 100%, 75%, 76%, 86%, and 86%, respectively for the training model with 1000 cases of F-18-FDG PET image for pre-training. The AUC values for various sample sizes of the training dataset (100, 200, 400, 800, 1000 cases) for pre-training were 0.86, 0.91, 0.95, 0.97, and 0.97. Regardless of the pre-training condition ECD dataset used, the AUC value was greater than 0.85. Finally, predicting cognitive scores and MMSE scores correlated (R2 = 0.7072). CONCLUSIONS: With the ADNI pre-trained model, the sensitivity and accuracy of the proposed deep learning model using SPECT ECD perfusion images to differentiate AD from NC were increased by approximately 30% and 10%, respectively. Our study indicated that the model trained on PET FDG metabolic imaging for the same disease could be transferred to a small sample of SPECT cerebral perfusion images. This model will contribute to the practicality of SPECT cerebral perfusion images using deep learning technology to objectively recognize AD.


Asunto(s)
Enfermedad de Alzheimer , Fluorodesoxiglucosa F18 , Encéfalo , Cisteína/análogos & derivados , Humanos , Masculino , Compuestos de Organotecnecio , Tomografía de Emisión de Positrones , Tomografía Computarizada de Emisión de Fotón Único
3.
PLoS One ; 14(4): e0216054, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31022255

RESUMEN

The aim of this study was to develop a geometric calibration method capable of eliminating the reconstruction artifacts of geometric misalignments in a tomosynthesis prototype with dual-axis scanning geometry. The potential scenarios of geometric misalignments were demonstrated, and their effects on reconstructed images were also evaluated. This method was a phantom-based approach with iterative optimization, and the calibration phantom was designed for specific tomosynthesis scanning geometry. The phantom was used to calculate a set of geometric parameters from each projection, and these parameters were then used to evaluate the geometric misalignments of the dual-axis scanning-geometry prototype. The simulated results revealed that the extracted geometric parameters were similar to the input values and that the artifacts of reconstructed images were minimized due to geometric calibration. Additionally, experimental chest phantom imaging results also indicated that the artifacts of the reconstructed images were suppressed and that object structures were preserved through calibration. And the quantitative analysis result also indicated that the MTF can be further improved with the geometric calibration. All the simulated and experimental results demonstrated that this method is effective for tomosynthesis with dual-axis scanning geometry. Furthermore, this geometric calibration method can also be applied to other tomography imaging systems to reduce geometric misalignments and be used for different geometric calibration phantom configurations.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Tórax/diagnóstico por imagen , Calibración , Simulación por Computador , Humanos , Fantasmas de Imagen , Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...