Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Tipo de estudio
Intervalo de año de publicación
1.
Phys Rev Lett ; 125(4): 044803, 2020 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-32794783

RESUMEN

Energy recovery has been achieved in a multipass linear accelerator, demonstrating a technology for more compact particle accelerators operating at higher currents and reduced energy consumption. Energy delivered to the beam during the first four passes through the accelerating structure was recovered during four subsequent decelerating passes. High-energy efficiency was achieved by the use of superconducting accelerating cavities and permanent magnets. The fixed-field alternating-gradient optical system used for the return loop successfully transported electron bunches of 42, 78, 114, and 150 MeV in a common vacuum chamber. This new kind of accelerator, an eight-pass energy recovery linac, has the potential to accelerate much higher current than existing linear accelerators while maintaining small beam dimensions and consuming much less energy per electron.

2.
Phys Rev Lett ; 99(15): 154801, 2007 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-17995173

RESUMEN

Acceleration of polarized protons in the energy range of 5 to 25 GeV is challenging. In a medium energy accelerator, the depolarizing spin resonances are strong enough to cause significant polarization loss but full Siberian snakes cause intolerably large orbit excursions and are also not feasible since straight sections usually are too short. Recently, two helical partial Siberian snakes with double pitch design have been installed in the Brookhaven Alternating Gradient Synchrotron (AGS). With a careful setup of optics at injection and along the energy ramp, this combination can eliminate the intrinsic and imperfection depolarizing resonances otherwise encountered during acceleration to maintain a high intensity polarized beam in medium energy synchrotrons. The observation of partial snake resonances of higher than second order will also be described.

3.
Phys Rev Lett ; 96(17): 174801, 2006 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-16712305

RESUMEN

The Brookhaven Relativistic Heavy Ion Collider (RHIC) has been providing collisions of polarized protons at a beam energy of 100 GeV since 2001. Equipped with two full Siberian snakes in each ring, polarization is preserved during acceleration from injection to 100 GeV. However, the intrinsic spin resonances beyond 100 GeV are about a factor of 2 stronger than those below 100 GeV making it important to examine the impact of these strong intrinsic spin resonances on polarization survival and the tolerance for vertical orbit distortions. Polarized protons were first accelerated to the record energy of 205 GeV in RHIC with a significant polarization measured at top energy in 2005. This Letter presents the results and discusses the sensitivity of the polarization survival to orbit distortions.

4.
Phys Rev Lett ; 84(6): 1184-7, 2000 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-11017474

RESUMEN

A new type of spin depolarization resonance has been observed at the Brookhaven Alternating Gradient Synchrotron (AGS). This spin resonance is identified as a strong closed-orbit sideband around the dominant intrinsic spin resonance. The strength of the resonance was proportional to the 9th harmonic component of the horizontal closed orbit and proportional to the vertical betatron oscillation amplitude. This "hybrid" spin resonance cannot be overcome by the partial snake at the AGS, but it can be corrected by the harmonic orbit correctors.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA