Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
1.
JACC Asia ; 4(4): 306-319, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38660100

RESUMEN

Background: Few reports on pre-existing left bundle branch block (LBBB) in patients undergoing transcatheter aortic valve replacement (TAVR) are currently available. Further, no present studies compare patients with new onset LBBB with those with pre-existing LBBB. Objectives: This study aimed to investigate the association between pre-existing or new onset LBBB and clinical outcomes after TAVR. Methods: Using data from the Japanese multicenter registry, 5,996 patients who underwent TAVR between October 2013 and December 2019 were included. Patients were classified into 3 groups: no LBBB, pre-existing LBBB, and new onset LBBB. The 2-year clinical outcomes were compared between 3 groups using Cox proportional hazards models and propensity score analysis to adjust the differences in baseline characteristics. Results: Of 5,996 patients who underwent TAVR, 280 (4.6%) had pre-existing LBBB, while 1,658 (27.6%) experienced new onset LBBB. Compared with the no LBBB group, multivariable Cox regression analysis showed that pre-existing LBBB was associated not only with a higher 2-year all-cause (adjusted HR: 1.39; 95% CI: 1.06-1.82; P = 0.015) and cardiovascular (adjusted HR: 1.60; 95% CI: 1.04-2.48; P = 0.031) mortality, but also with higher all-cause (adjusted HR: 1.43, 95% CI: 1.07-1.91; P = 0.016) and cardiovascular (adjusted HR: 1.81, 95% CI:1.12-2.93; P = 0.014) mortality than the new onset LBBB group. Heart failure was the most common cause of cardiovascular death, with more heart failure deaths in the pre-existing LBBB group. Conclusions: Pre-existing LBBB was independently associated with poor clinical outcomes, reflecting an increased risk of cardiovascular mortality after TAVR. Patients with pre-existing LBBB should be carefully monitored.

3.
Circ J ; 88(4): 451-459, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-36754386

RESUMEN

BACKGROUND: This study investigated the impact and predictive factors of concomitant significant tricuspid regurgitation (TR) and evaluated the roles of right ventricle (RV) function and the etiology of TR in the clinical outcomes of patients with severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI).Methods and Results: We assessed grading of TR severity, TR etiology, and RV function in pre- and post-TAVI transthoracic echocardiograms for 678 patients at Keio University School of Medicine. TR etiology was divided into 3 groups: primary TR, ventricular functional TR (FTR), and atrial FTR. The primary outcomes were all-cause and cardiovascular death. At baseline, moderate or greater TR was found in 55 (8%) patients and, after adjustment for comorbidities, was associated with increased all-cause death (hazard ratio [HR] 2.11; 95% confidence interval [CI] 1.19-3.77; P=0.011) and cardiovascular death (HR 2.29; 95% CI 1.06-4.99; P=0.036). RV dysfunction (RVD) also remained an independent predictor of cardiovascular death (HR 2.06; 95% CI 1.03-4.14; P=0.042). Among the TR etiology groups, patients with ventricular FTR had the lowest survival rate (P<0.001). Patients with persistent RVD after TAVI had a higher risk of cardiovascular death than those with a normal or recovered RV function (P<0.001). CONCLUSIONS: The etiology of TR and RV function play an important role in predicting outcomes in concomitant TR patients undergoing TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Insuficiencia de la Válvula Tricúspide , Disfunción Ventricular Derecha , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Insuficiencia de la Válvula Tricúspide/cirugía , Resultado del Tratamiento , Disfunción Ventricular Derecha/etiología , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Estudios Retrospectivos , Válvula Aórtica/cirugía
5.
JACC Cardiovasc Interv ; 16(1): 79-91, 2023 01 09.
Artículo en Inglés | MEDLINE | ID: mdl-36599591

RESUMEN

BACKGROUND: Several trials demonstrated that aspirin monotherapy compared with aspirin plus clopidogrel is associated with a lower incidence of bleeding without an increased risk of ischemic events in patients after transcatheter aortic valve replacement (TAVR); however, there remains a paucity of data to prove the necessity of even aspirin monotherapy. OBJECTIVES: This study aimed to compare clinical outcomes and valve performance of the 3 different antithrombotic strategies post-TAVR from the OCEAN-TAVI (Optimized transCathEter vAlvular iNtervention) registry. METHODS: Patients who received anticoagulation or had procedural complications were excluded. The remaining patients were classified into 3 groups according to the antithrombotic regimen at discharge: 1) nonantithrombotic therapy (None); 2) single-antiplatelet therapy (SAPT); and 3) dual-antiplatelet therapy (DAPT). The primary outcome was the incidence of net adverse clinical events (NACEs) (ie, cardiovascular death, stroke, myocardial infarction, and life-threatening or major bleeding). RESULTS: Overall, 3,575 TAVR patients were included (None, 293; SAPT, 1,354; DAPT, 1,928). The median follow-up period was 841 days (IQR: 597-1,340 days). The incidence of NACEs did not differ between the groups (None vs SAPT: adjusted HR [aHR]: 1.18; P = 0.45; None vs DAPT: aHR: 1.09; P = 0.67). There was a lower incidence of all bleeding in patients with no antithrombotics (None vs SAPT: aHR: 0.63; P = 0.12; None vs DAPT: aHR: 0.51; P = 0.04). The valve performance was similar among the groups. Leaflet thrombosis was detected in 8.5% of the nonantithrombotic group. CONCLUSIONS: Compared with SAPT/DAPT, the nonantithrombotic strategy was not associated with an increased risk of NACEs and potentially reduced the risk of bleeding events. The nonantithrombotic strategy may be an acceptable alternative to SAPT/DAPT in selected patients with TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Inhibidores de Agregación Plaquetaria/efectos adversos , Resultado del Tratamiento , Quimioterapia Combinada , Aspirina/efectos adversos , Hemorragia/inducido químicamente , Sistema de Registros , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía
6.
J Am Heart Assoc ; 11(23): e026334, 2022 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-36444836

RESUMEN

Background Subclinical leaflet thrombosis, characterized by hypoattenuated leaflet thickening (HALT) on multidetector computed tomography, is common after transcatheter aortic valve replacement (TAVR). Because little is known about the long-term natural history of subclinical HALT, we aimed to investigate this in patients who underwent TAVR without using additional anticoagulation. Methods and Results We retrospectively evaluated patients who underwent TAVR with the Edwards SAPIEN-XT at our institute between October 2013 and December 2015. Patients were grouped according to the presence or absence of HALT within 1 year after TAVR (HALT and No-HALT groups). The primary outcome, defined as the composite of all-cause mortality, heart failure readmission, and ischemic stroke, was compared. Valve performance was assessed over time by transthoracic echocardiography. Among 124 patients (men: 29.1%; median age, 85 years), 27 (21.8%) showed HALT on multidetector computed tomography within 1 year after TAVR. No patient required additional anticoagulation for treating HALT because of the absence of valve-related symptomatic deterioration. During the median follow-up period of 4.7 years (interquartile range, 4.0-5.6), the rate of primary outcome and valve performance was not statistically different between the 2 groups (37.0% versus 38.1%; log-rank test P=0.92; mean pressure gradient, 9 mm Hg [8-14 mm Hg] versus 10 mm Hg [7-15 mm Hg]; P=0.51, respectively). Conclusions Approximately 20% of patients after TAVR had HALT within 1 year; however, that did not change the risk of subsequent adverse cardiovascular events or the valve performance with statistical significance for up to 5 years despite no additional anticoagulation therapy.


Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano de 80 o más Años , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estudios de Seguimiento , Estudios Retrospectivos
7.
ESC Heart Fail ; 9(4): 2695-2702, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35674410

RESUMEN

AIMS: Transcatheter aortic valvular replacement (TAVR) is increasingly being performed for elderly patients with aortic stenosis (AS), and current guidelines acknowledge the importance of shared decision-making in their management. This study aimed to evaluate elderly symptomatic severe AS patients' perspectives on their treatment goals and identify factors that influence their treatment choice. METHODS AND RESULTS: We performed a pre-procedural cross-sectional survey using a questionnaire at a single university hospital. The questionnaire included three primary domains: (i) symptom burden, (ii) goals and important factors related to treatment, and (iii) preferred place of residence after treatment. We investigated 98 symptomatic severe AS patients who underwent TAVR (median age 86 years, 26% men). None of the patients died during hospitalization, and most of them (94%) were discharged home. Prior to TAVR, the three most common symptom burdens were poor mobility (52%), shortness of breath (52%), and weakness (44%). The reported preferred treatment goals were symptom burden reduction (78%), independence maintenance (68%), ability to perform a specific activity/hobby (62%), and improvement in prognosis (58%). In total, 54% of the patients rated 'in alignment with my values' as the factor that affected their decision to undergo TAVR. Nearly all patients (95%) stated that they preferred to live at home after TAVR. CONCLUSIONS: Among elderly AS patients with varying symptoms who underwent TAVR, symptom burden reduction was the most cited patient-reported goal. Nearly all the patients preferred to live at home after the procedure. Encouraging patients to define their specific goals may improve the quality of shared decision-making in such settings.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Estudios Transversales , Femenino , Objetivos , Humanos , Masculino , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/métodos
8.
Cardiovasc Interv Ther ; 37(4): 717-724, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35129792

RESUMEN

Several studies have demonstrated better hemodynamic stability of mechanically expanding valves following transcatheter aortic valve replacement (TAVR). This study aims to assess the expansion or recoil of transcatheter aortic valves using multidetector computed tomography (MDCT). This was a retrospective study. Among 873 patients who underwent TAVR with balloon-expandable (SAPIEN 3) or mechanically expanding valves (LOTUS) at Keio University Hospital between 2013 and 2020, those who underwent serial MDCT and echocardiographic assessment (pre-procedure, discharge, 6 months, 1 year, and 2 years post-TAVR) as our hospital protocol were included in this analysis (N = 30; LOTUS = 12; SAPIEN 3 = 18). The pre- and post-procedural echocardiographic data and the valve expansion rate evaluated by MDCT were compared between the groups. In LOTUS valves, late-phase expansion was observed on computed tomography (mean expansion rate, 83.8% at discharge and 86.8%, 2 years postoperative, p < 0.001), and a gradual increase in the aortic valve area was observed on echocardiography (aortic valve area: 1.45 cm2 at discharge and 1.51 cm2, 2 years postoperative, p = 0.01). Conversely, in SAPIEN 3, valve expansion was not seen in the late phase (mean expansion rate, 84.5% at discharge and 83.8%, 2 years postoperative) with a decrease in the aortic valve area (1.41 cm2 at discharge and 1.37 cm2, 2 years postoperative, p = 0.04). The expansion of the middle portion of the LOTUS valves was attributed to the increase in the aortic valve area. In conclusion, this study demonstrated the greater late-phase expansion and better valve performance of mechanically expanding valves.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
9.
CJC Pediatr Congenit Heart Dis ; 1(5): 241-244, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37969434

RESUMEN

The prevalence of atrial tachyarrhythmia is high in patients with atrial septal defect (ASD), and catheter ablation (CA) is often performed before percutaneous ASD closure. We aimed to clarify the effect of CA on the ASD size. We analysed 16 patients with secundum ASD who had a history of CA for atrial tachyarrhythmia and underwent ASD size evaluation before and after CA. The size of ASD significantly decreased after CA. Younger age and lower tricuspid regurgitation pressure gradients and pulmonary arterial systolic pressures were associated with size reduction. These factors are crucial for making strategies of percutaneous ASD closure.


La prévalence de la tachyarythmie auriculaire est élevée chez les patients qui présentent une communication interauriculaire (CIA), et l'on pratique souvent une ablation par cathéter avant la fermeture percutanée de la CIA. Notre objectif consistait à éclaircir l'effet de l'ablation par cathéter sur la taille de la CIA. Pour ce faire, nous avons analysé 16 patients présentant une CIA de type ostium secundum, ayant déjà subi une ablation par cathéter et chez qui la taille de la CIA a été évaluée avant et après l'intervention. La taille de la CIA a diminué de manière significative après l'ablation par cathéter. Les facteurs associés à la réduction de la taille de la communication comprennent un âge plus jeune, des gradients de pression plus faibles pour l'insuffisance tricuspidienne et une pression artérielle systolique moins élevée. Il est crucial de tenir compte de ces facteurs lors de l'établissement d'une stratégie pour la fermeture percutanée d'une CIA.

10.
Open Heart ; 8(2)2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34810275

RESUMEN

OBJECTIVE: Transcatheter aortic valve replacement (TAVR) improves clinical symptoms in most patients with severe aortic stenosis (AS). However, some patients do not benefit from the symptom-reducing effects of TAVR. We assessed the predictors and clinical outcomes of poor symptomatic improvement (SI) after TAVR. METHODS: A total of 1749 patients with severe symptomatic AS undergoing transfemoral TAVR were evaluated using the Japanese multicentre TAVR registry. Poor SI was defined as readmission for heart failure (HF) within 1 year after TAVR or New York Heart Association (NYHA) class ≥3 after 1 year. A logistic regression model was used to identify predictors of poor SI. One-year landmark analysis after TAVR was used to evaluate the association between poor SI and clinical outcomes. RESULTS: Among the overall population (mean age, 84.5 years; female, 71.3%; mean STS score, 6.3%), 6.6% were categorised as having poor SI. Atrial fibrillation, chronic obstructive pulmonary disease, Clinical Frailty Scale ≥4, chronic kidney disease and moderate to severe mitral regurgitation were independent predictors of poor SI. One-year landmark analysis demonstrated that poor SI had a higher incidence of all-cause death and readmission for HF compared with SI (p<0.001). Poor SI with preprocedural NYHA class 2 had a worse outcome than SI with preprocedural NYHA class ≥3. CONCLUSIONS: Poor SI was associated with worse outcomes 1 year after the procedure. It had a greater impact on clinical outcomes than baseline symptoms. TAVR may be challenging for patients with many predictors of poor SI. TRIAL REGISTRATION NUMBER: This registry, associated with the University Hospital Medical Information Network Clinical Trials Registry, was accepted by the International Committee of Medical Journal Editors (UMIN-ID: 000020423).


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Insuficiencia Cardíaca/epidemiología , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Causas de Muerte/tendencias , Ecocardiografía , Insuficiencia Cardíaca/etiología , Humanos , Incidencia , Japón/epidemiología , Estudios Prospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Tasa de Supervivencia/tendencias
11.
J Cardiol ; 78(6): 533-541, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34348863

RESUMEN

BACKGROUND: Dialysis patients with aortic stenosis are generally considered as being at extreme or high surgical risk. Herein, the first clinical trial was conducted to investigate clinical safety and effectiveness of transcatheter aortic valve replacement (TAVR) using the balloon-expandable transcatheter aortic valve (SAPIEN 3, Edwards Lifesciences, Irvine, CA, USA) in Japanese dialysis patients. METHODS: The clinical trial is a single arm, prospective, open, non-randomized, Japanese multicenter study. The primary purpose of this trial is to evaluate the efficacy and safety of TAVR using SAPIEN 3 in 28 Japanese dialysis patients. RESULTS: Mean age was 79.2 years and 67.9% were male (Mean STS score was 14.3%). Transfemoral and transapical approaches were performed in 25 (89.3%) and 3 patients (10.7%), respectively. All bioprostheses were successfully implanted. Median intensive care unit stay and hospital stay after TAVR were 1.4 days and 6.3 days, respectively. In-hospital mortality was 3.6% and freedom from all-cause mortality at 1 year was 89.3%. Disabling stroke and life-threatening bleeding at 1 year was 7.7% and 8.5%, respectively. There was no structural valve deterioration during follow-up. New York Heart Association functional status, six-minute walk test, and EuroQOL visual analogue scale score significantly improved through 1 year compared with baseline. CONCLUSIONS: TAVR using SAPIEN 3 is safe and effective for the treatment of Japanese dialysis patients with symptomatic severe aortic valve stenosis.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Japón/epidemiología , Masculino , Estudios Prospectivos , Diseño de Prótesis , Diálisis Renal , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
13.
Circ Cardiovasc Interv ; 14(5): e010097, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-34003663

RESUMEN

BACKGROUND: Current guidelines recommend dual antiplatelet therapy for the first 1 to 6 months after transcatheter aortic valve replacement (TAVR); however, recent studies have reported better outcomes with single antiplatelet therapy than with dual antiplatelet therapy in the occurrence of bleeding events, while not increasing thrombotic events. However, no data exist about optimal single antiplatelet therapy following TAVR. METHODS: Patients who underwent TAVR between October 2013 and May 2017 were enrolled from the OCEAN-TAVI Japanese multicenter registry (Optimized Transcatheter Valvular Intervention). After excluding 1759 patients, 829 who received aspirin (100 mg/d) or clopidogrel (75 mg/d) after TAVR were identified and stratified according to the presence or absence of anticoagulation. Propensity score matching was performed to adjust the baseline characteristics between the aspirin and clopidogrel groups. Outcomes of interest were all-cause and cardiovascular deaths, stroke, and life-threatening or major bleeding within 2 years following TAVR. RESULTS: After propensity score matching, 98 and 157 pairs of patients without and with anticoagulation, respectively, were identified. Falsification end points of pneumonia, urinary tract infection, and hip fracture were evaluated, and their rates were not different between groups. All-cause deaths were not statistically different between the groups in patients with (aspirin, 17.5%; clopidogrel, 11.1%; log-rank P=0.07) and without (aspirin, 29.6%; clopidogrel, 20.1%; log-rank P=0.15) anticoagulation at 2 years post-TAVR, whereas clopidogrel was associated with a lower cardiovascular mortality at 2 years in patients with (aspirin, 8.5%; clopidogrel, 2.7%; log-rank P=0.03) and without (aspirin, 18.0%; clopidogrel, 5.2%; log-rank P=0.02) anticoagulation. CONCLUSIONS: We demonstrated that clopidogrel monotherapy was associated with a lower incidence of cardiovascular death compared with aspirin monotherapy during the 2-year follow-up after TAVR regardless of anticoagulation use. REGISTRATION: URL: https://upload.umin.ac.jp; Unique identifier: UMIN000020423.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Aspirina/efectos adversos , Clopidogrel/efectos adversos , Fibrinolíticos/efectos adversos , Humanos , Inhibidores de Agregación Plaquetaria/efectos adversos , Sistema de Registros , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
14.
Heart Lung Circ ; 30(9): 1406-1413, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33863668

RESUMEN

BACKGROUND: New-onset atrial tachyarrhythmia (ATA) often develops after atrial septal defect (ASD) closure. Its development raises some potential concerns such as stroke and bleeding complications caused by anticoagulant therapy and limited access to the left atrium for catheter ablation. Although it is essential to identify the risk factors of new-onset ATA, few studies have examined these factors. This study investigated unknown risk factors for the development of new-onset ATA after transcatheter ASD closure in patients without a history of ATA. METHODS: A total of 238 patients without a history of ATA, aged ≥18 years and who underwent transcatheter ASD closure at the current hospital were reviewed. Patient characteristics were compared between the groups with and without new-onset ATA. The factors associated with new-onset ATA were examined using univariate and multivariable analyses. RESULTS: Thirteen (13) (5.5%) patients experienced ATA during follow-up (mean, 21±14 months). Compared with patients without new-onset ATA, patients with new-onset ATA were older (48±18 vs 66±11 years; p<0.001) and had high brain natriuretic peptide (BNP) levels (36±36 vs 177±306 pg/mL; p<0.001). On multivariable analysis, BNP ≥40 pg/mL before ASD closure was associated with new-onset ATA after adjusting for age (OR, 4.91; 95% CI, 1.22-19.8; p=0.025). CONCLUSION: Patients with BNP levels >40 pg/mL before transcatheter ASD closure may have a higher risk of developing new-onset ATA.


Asunto(s)
Cateterismo Cardíaco , Defectos del Tabique Interatrial , Adolescente , Adulto , Cateterismo Cardíaco/efectos adversos , Atrios Cardíacos/diagnóstico por imagen , Defectos del Tabique Interatrial/epidemiología , Defectos del Tabique Interatrial/cirugía , Humanos , Taquicardia/epidemiología , Taquicardia/etiología , Resultado del Tratamiento
15.
J Am Heart Assoc ; 10(7): e019543, 2021 04 06.
Artículo en Inglés | MEDLINE | ID: mdl-33749309

RESUMEN

Background In patients undergoing transcatheter aortic valve replacement (TAVR), those with small left ventricle (LV) may have an increased risk of poor outcomes, because small LV is associated with low-flow (LF), left ventricular hypertrophy. However, the impact of small LV on patients undergoing TAVR remains unknown. Methods and Results We examined 2584 patients who underwent TAVR between October 2013 and May 2017 using data from the Japanese multicenter registry. On the basis of the American Society of Echocardiography guidelines, small LV was defined as left ventricular end-diastolic dimension <42.0 mm for men or <37.8 mm for women. The 2-year clinical outcomes were compared between patients with and without small LV using multivariable Cox regression analyses and propensity score matching. Subgroup analyses by LF, left ventricular hypertrophy were performed. Of 2584 patients who underwent TAVR, 466 (18.0%) had small LV. Patients with small LV had smaller body size and less comorbidity, and were more likely to have LF status compared with those without. Small LV was associated with a higher 2-year all-cause (20.8% versus 14.3%; adjusted hazard ratio [HR],1.58 [95% CI, 1.20-2.09]; P=0.0013) and cardiovascular mortality (8.8% versus 5.5%; adjusted HR, 1.93 [95% CI, 1.25-2.98]; P=0.0028). Propensity score matching analysis showed consistent findings. In subgroup analyses, LF, left ventricular hypertrophy did not interact with small LV. Conclusions Small LV, determined by a simple echocardiographic parameter, was associated with poorer clinical outcomes after TAVR regardless of LF, left ventricular hypertrophy. LV size may be useful for assessing clinical outcomes after TAVR. Registration URL: https://www.umin.ac.jp/ctr/index.htm; Unique identifier: UMIN000020423.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Sistema de Registros , Volumen Sistólico/fisiología , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Función Ventricular Izquierda/fisiología , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/fisiopatología , Diástole , Ecocardiografía , Femenino , Estudios de Seguimiento , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Tamaño de los Órganos , Puntaje de Propensión , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad
16.
CJC Open ; 3(1): 124-126, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32984799

RESUMEN

Thrombosis, especially venous thromboembolism, is a complication often associated with coronavirus disease 2019 (COVID-19). However, there have been relatively few reports of arterial thrombosis. Here, we describe a case of non-severe COVID-19 in a patient with dilated cardiomyopathy. After admission, symptoms, laboratory data, and imaging findings improved, but D-dimer levels gradually increased. Contrast computed tomography and echocardiography revealed a left ventricular thrombus. Anticoagulant treatment diminished the thrombus, and the patient recovered and was discharged. Although a left ventricular thrombus is a rare COVID-19 complication, performing appropriate diagnostic tests could improve COVID-19 mortality in patients with dilated cardiomyopathy.


La thrombose, en particulier la maladie thromboembolique veineuse, est une complication souvent associée à la maladie à coronavirus 2019 (COVID-19). Cependant, il y a eu relativement peu de cas rapportés de thrombose artérielle. Nous décrivons ici un cas non grave de COVID-19 chez un patient atteint de cardiomyopathie dilatée. Après admission, des améliorations ont été constatées concernant les symptômes, les résultats des tests de laboratoire et les résultats d'imagerie, mais les taux de D-dimères ont progressivement augmenté. La tomodensitométrie avec produit de contraste et l'échocardiographie ont révélé un thrombus ventriculaire gauche. Un traitement anticoagulant a réduit le thrombus, et le patient s'est remis et a reçu son congé. Bien qu'un thrombus ventriculaire gauche soit une complication rare de la COVID-19, la réalisation de tests diagnostiques appropriés pourrait diminuer la mortalité due à la COVID-19 chez les patients atteints de cardiomyopathie dilatée.

17.
Catheter Cardiovasc Interv ; 97(6): E875-E886, 2021 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-32926552

RESUMEN

OBJECTIVES: To compare safety, efficacy, and hemodynamics of transfemoral transcatheter aortic valve replacement (TAVR) using self-expanding and balloon-expandable transcatheter heart valves (THVs) in patients with a small aortic annulus. BACKGROUND: Few studies have directly compared TAVR outcomes using third-generation THVs, focusing on patients with small aortic annuli. METHODS: In a multicenter TAVR registry, we analyzed data from 576 patients with a small annulus and who underwent transfemoral TAVR using third-generation THVs. Propensity score matching was used to adjust baseline clinical characteristics. RESULTS: The device success rate in the overall cohort was 92.0% (Evolut R: 92.1% vs. Sapien 3:92.0%, p = 0.96). One year after TAVR, patients treated with Evolut R maintained a lower mean pressure gradient (mPG) and a higher indexed effective orifice area (iEOA) in the matched cohort {mPG: 9.0 [interquartile range (IQR): 6.0-11.9] vs. 12.0 [IQR: 9.9-16.3] mmHg, p < .001; iEOA: 1.20 [IQR: 1.01-1.46] vs. 1.08 [IQR: 0.90-1.28] cm2 /m2 , p < .001}. However, no significant differences were reported in the incidence of severe prosthesis-patient mismatch and aortic regurgitation at 1 year. Furthermore, both groups showed comparable outcomes with no differences in terms of all-cause mortality (log-lank test, p = .81). CONCLUSIONS: TAVR for patients with a small annulus using third-generation THVs was associated with high device success. Evolut R seems to be superior to Sapien 3 in hemodynamic performance for patients with a small annulus and body surface area up to 1 year after TAVR. Nevertheless, all-cause mortality at 1 year was similar between both groups.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Hemodinámica , Humanos , Japón , Diseño de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
18.
Int J Cardiovasc Imaging ; 37(4): 1159-1168, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33151513

RESUMEN

Detail morphological evaluation for ASD is essential to achieve successful transcatheter closure. Three-dimensional transesophageal echocardiography (3D-TEE) is emerging, but few studies have comprehensively verified the usefulness of 3D-TEE. We divided 329 patients who underwent transcatheter ASD closure at our university hospital into 157 in the Conventional group evaluated with 2-dimensional transesophageal echocardiography and balloon sizing (BS), and 172 in the 3D-TEE group evaluated with 3D-TEE additionally. We assessed usefulness of 3D-TEE and consider appropriate device selection procedure. Overall, the percentage with re-sizing of device tended to be lower in the 3D-TEE group than in the Conventional group (10.1% vs 6.0%, p = 0.187). Among preprocedural modalities, the device size was mainly decided based on the BS diameter. A logistic regression analysis demonstrated that large atrial septum aneurysms (ASA) were associated with a ≥ 2 mm discrepancy of the BS diameter from the preprocedural 3D-TEE diameter (p < 0.05). Compared to the Amplatzer Septal Occluder, the differences in device size and the preprocedural ASD measurement were greater when using the Occlutech Figulla Flex II Occluder (FFII). Particularly, among the patients implanted with FFIIs, the discrepancies of the device size from the 3D-TEE measurement were greater in patients with large ASA than those with small ASA. Preprocedural 3D-TEE is useful to select the appropriate device size. Particularly, it is necessary to select a much larger device than that derived from the preprocedural 3D-TEE measurement when using FFII in patients with a septal aneurysm.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Defectos del Tabique Interatrial/diagnóstico por imagen , Defectos del Tabique Interatrial/terapia , Dispositivo Oclusor Septal , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/efectos adversos , Niño , Toma de Decisiones Clínicas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Diseño de Prótesis , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
19.
Open Heart ; 7(2)2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32641381

RESUMEN

OBJECTIVE: There is paucity of data on optimal medical treatment, including use of beta blockers for patients undergoing transcatheter aortic valve replacement (TAVR). The study aimed to investigate the association of beta blockers and clinical outcomes following TAVR. METHODS: We examined data of 2563 patients who underwent TAVR between October 2013 and May 2017 obtained from a prospective multicentre cohort registry, the optimised catheter valvular intervention-TAVI registry. We compared the 2-year cardiovascular and non-cardiovascular mortality and in-hospital outcomes between patients with and without preprocedural beta-blocker administration by propensity score matching (PSM). RESULTS: Preprocedural beta blockers were prescribed in 867 patients (33.8%). After PSM, the incidence of in-hospital congestive heart failure was significantly lower in patients with preprocedural beta blocker (p=0.046). No differences were found in 2-year cardiovascular and non-cardiovascular mortality. In the subgroup analyses, beta-blocker administration was associated with a lower cardiovascular mortality within 2 years in patients with a history of coronary artery bypass grafting (CABG; log-rank p=0.017), presence of peripheral artery disease (PAD; log-rank p=0.003) and brain natriuretic peptide (BNP) ≥400 pg/mL (log-rank p=0.003). When stratified by postprocedural left ventricular ejection fraction (post-LVEF), beta-blocker administration was associated with a lower cardiovascular mortality among patients with post-LVEF <50% (log-rank p=0.024). CONCLUSIONS: Preprocedural beta-blocker administration was not associated with 2-year cardiovascular and non-cardiovascular mortality in overall, but was associated with a lower 2-year cardiovascular mortality in patients with a history of CABG, presence of PAD, BNP ≥400 pg/mL and post-LVEF <50%. The findings must be validated using randomised trials.


Asunto(s)
Antagonistas Adrenérgicos beta/uso terapéutico , Estenosis de la Válvula Aórtica/cirugía , Insuficiencia Cardíaca/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter , Antagonistas Adrenérgicos beta/efectos adversos , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Volumen Sistólico/efectos de los fármacos , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Función Ventricular Izquierda/efectos de los fármacos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...