Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Eur Radiol Exp ; 7(1): 38, 2023 08 03.
Artículo en Inglés | MEDLINE | ID: mdl-37532922

RESUMEN

BACKGROUND: Heterotopic ossification (HO) is a frequent and debilitating complication of traumatic musculoskeletal injuries and orthopedic procedures. Prophylactic dosing of botulinum toxin type A (BTxA) holds potential as a novel treatment option if accurately distributed throughout soft-tissue volumes where protection is clinically desired. We developed a high-resolution, microcomputed tomography (microCT)-based imaging strategy to assess drug distribution and validated this platform by quantifying distribution achieved via a prototype delivery system versus a single-bolus injection. METHODS: We injected an iodine-containing contrast agent (iodixanol 320 mg I/mL) into dissected rabbit musculature followed by microCT imaging and analysis. To contrast the performance of distributed versus bolus injections, a three-dimensional (3D) 64-cm3-printed soft-tissue holder was developed. A centered 2-cm3 volume of interest (VOI) was targeted with a single-bolus injection or an equal volume distributed injection delivered via a 3D-printed prototype. VOI drug coverage was quantified as a percentage of the VOI volume that was < 1.0 mm from the injected fluid. RESULTS: The microCT-based approach enabled high-resolution quantification of injection distribution within soft tissue. The distributed dosing prototype provided significantly greater tissue coverage of the targeted VOI (72 ± 3%, mean ± standard deviation) when compared to an equal volume bolus dose (43 ± 5%, p = 0.031) while also enhancing the precision of injection targeting. CONCLUSIONS: A microCT-based imaging technique precisely quantifies drug distribution within a soft-tissue VOI, providing a path to overcome a barrier for clinical translation of prophylactic inhibition of HO by BTxA. RELEVANCE STATEMENT: This platform will facilitate rapid optimization of injection parameters for clinical devices used to effectively and safely inhibit the formation of heterotopic ossification. KEY POINTS: • MicroCT provides high-resolution quantification of soft-tissue drug distribution. • Distributed dosing is required to maximize soft-tissue drug coverage. • Imaging platform will enable rapid screening of 3D-printed drug distribution prototypes.


Asunto(s)
Yodo , Osificación Heterotópica , Animales , Conejos , Microtomografía por Rayos X/métodos , Sistemas de Liberación de Medicamentos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...