Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Radiology ; 301(2): 295-308, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34427465

RESUMEN

Background Suppression of background parenchymal enhancement (BPE) is commonly observed after neoadjuvant chemotherapy (NAC) at contrast-enhanced breast MRI. It was hypothesized that nonsuppressed BPE may be associated with inferior response to NAC. Purpose To investigate the relationship between lack of BPE suppression and pathologic response. Materials and Methods A retrospective review was performed for women with menopausal status data who were treated for breast cancer by one of 10 drug arms (standard NAC with or without experimental agents) between May 2010 and November 2016 in the Investigation of Serial Studies to Predict Your Therapeutic Response with Imaging and Molecular Analysis 2, or I-SPY 2 TRIAL (NCT01042379). Patients underwent MRI at four points: before treatment (T0), early treatment (T1), interregimen (T2), and before surgery (T3). BPE was quantitatively measured by using automated fibroglandular tissue segmentation. To test the hypothesis effectively, a subset of examinations with BPE with high-quality segmentation was selected. BPE change from T0 was defined as suppressed or nonsuppressed for each point. The Fisher exact test and the Z tests of proportions with Yates continuity correction were used to examine the relationship between BPE suppression and pathologic complete response (pCR) in hormone receptor (HR)-positive and HR-negative cohorts. Results A total of 3528 MRI scans from 882 patients (mean age, 48 years ± 10 [standard deviation]) were reviewed and the subset of patients with high-quality BPE segmentation was determined (T1, 433 patients; T2, 396 patients; T3, 380 patients). In the HR-positive cohort, an association between lack of BPE suppression and lower pCR rate was detected at T2 (nonsuppressed vs suppressed, 11.8% [six of 51] vs 28.9% [50 of 173]; difference, 17.1% [95% CI: 4.7, 29.5]; P = .02) and T3 (nonsuppressed vs suppressed, 5.3% [two of 38] vs 27.4% [48 of 175]; difference, 22.2% [95% CI: 10.9, 33.5]; P = .003). In the HR-negative cohort, patients with nonsuppressed BPE had lower estimated pCR rate at all points, but the P values for the association were all greater than .05. Conclusions In hormone receptor-positive breast cancer, lack of background parenchymal enhancement suppression may indicate inferior treatment response. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Philpotts in this issue.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/tratamiento farmacológico , Quimioterapia Adyuvante/métodos , Medios de Contraste , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Terapia Neoadyuvante/métodos , Adulto , Anciano , Mama/diagnóstico por imagen , Estudios de Cohortes , Femenino , Humanos , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
2.
J Breast Imaging ; 3(1): 44-56, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33543122

RESUMEN

OBJECTIVE: The A6702 multisite trial confirmed that apparent diffusion coefficient (ADC) measures can improve breast MRI accuracy and reduce unnecessary biopsies, but also found that technical issues rendered many lesions non-evaluable on diffusion-weighted imaging (DWI). This secondary analysis investigated factors affecting lesion evaluability and impact on diagnostic performance. METHODS: The A6702 protocol was IRB-approved at 10 institutions; participants provided informed consent. In total, 103 women with 142 MRI-detected breast lesions (BI-RADS assessment category 3, 4, or 5) completed the study. DWI was acquired at 1.5T and 3T using a four b-value, echo-planar imaging sequence. Scans were reviewed for multiple quality factors (artifacts, signal-to-noise, misregistration, and fat suppression); lesions were considered non-evaluable if there was low confidence in ADC measurement. Associations of lesion evaluability with imaging and lesion characteristics were determined. Areas under the receiver operating characteristic curves (AUCs) were compared using bootstrapping. RESULTS: Thirty percent (42/142) of lesions were non-evaluable on DWI; 23% (32/142) with image quality issues, 7% (10/142) with conspicuity and/or localization issues. Misregistration was the only factor associated with non-evaluability (P = 0.001). Smaller (≤10 mm) lesions were more commonly non-evaluable than larger lesions (p <0.03), though not significant after multiplicity correction. The AUC for differentiating benign and malignant lesions increased after excluding non-evaluable lesions, from 0.61 (95% CI: 0.50-0.71) to 0.75 (95% CI: 0.65-0.84). CONCLUSION: Image quality remains a technical challenge in breast DWI, particularly for smaller lesions. Protocol optimization and advanced acquisition and post-processing techniques would help to improve clinical utility.

3.
Radiology ; 298(1): 60-70, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33201788

RESUMEN

Background The Eastern Cooperative Oncology Group and American College of Radiology Imaging Network Cancer Research Group A6702 multicenter trial helped confirm the potential of diffusion-weighted MRI for improving differential diagnosis of suspicious breast abnormalities and reducing unnecessary biopsies. A prespecified secondary objective was to explore the relative value of different approaches for quantitative assessment of lesions at diffusion-weighted MRI. Purpose To determine whether alternate calculations of apparent diffusion coefficient (ADC) can help further improve diagnostic performance versus mean ADC values alone for analysis of suspicious breast lesions at MRI. Materials and Methods This prospective trial (ClinicalTrials.gov identifier: NCT02022579) enrolled consecutive women (from March 2014 to April 2015) with a Breast Imaging Reporting and Data System category of 3, 4, or 5 at breast MRI. All study participants underwent standardized diffusion-weighted MRI (b = 0, 100, 600, and 800 sec/mm2). Centralized ADC measures were performed, including manually drawn whole-lesion and hotspot regions of interest, histogram metrics, normalized ADC, and variable b-value combinations. Diagnostic performance was estimated by using the area under the receiver operating characteristic curve (AUC). Reduction in biopsy rate (maintaining 100% sensitivity) was estimated according to thresholds for each ADC metric. Results Among 107 enrolled women, 81 lesions with outcomes (28 malignant and 53 benign) in 67 women (median age, 49 years; interquartile range, 41-60 years) were analyzed. Among ADC metrics tested, none improved diagnostic performance versus standard mean ADC (AUC, 0.59-0.79 vs AUC, 0.75; P = .02-.84), and maximum ADC had worse performance (AUC, 0.52; P < .001). The 25th-percentile ADC metric provided the best performance (AUC, 0.79; 95% CI: 0.70, 0.88), and a threshold using median ADC provided the greatest reduction in biopsy rate of 23.9% (95% CI: 14.8, 32.9; 16 of 67 BI-RADS category 4 and 5 lesions). Nonzero minimum b value (100, 600, and 800 sec/mm2) did not improve the AUC (0.74; P = .28), and several combinations of two b values (0 and 600, 100 and 600, 0 and 800, and 100 and 800 sec/mm2; AUC, 0.73-0.76) provided results similar to those seen with calculations of four b values (AUC, 0.75; P = .17-.87). Conclusion Mean apparent diffusion coefficient calculated with a two-b-value acquisition is a simple and sufficient diffusion-weighted MRI metric to augment diagnostic performance of breast MRI compared with more complex approaches to apparent diffusion coefficient measurement. © RSNA, 2020 Online supplemental material is available for this article.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética/métodos , Adulto , Anciano , Mama/diagnóstico por imagen , Diagnóstico Diferencial , Femenino , Humanos , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Sociedades Médicas , Adulto Joven
4.
NMR Biomed ; 27(7): 760-73, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24798066

RESUMEN

Shutter-speed pharmacokinetic analysis of dynamic-contrast-enhanced (DCE)-MRI data allows evaluation of equilibrium inter-compartmental water interchange kinetics. The process measured here - transcytolemmal water exchange - is characterized by the mean intracellular water molecule lifetime (τi). The τi biomarker is a true intensive property not accessible by any formulation of the tracer pharmacokinetic paradigm, which inherently assumes it is effectively zero when applied to DCE-MRI. We present population-averaged in vivo human breast whole tumor τi changes induced by therapy, along with those of other pharmacokinetic parameters. In responding patients, the DCE parameters change significantly after only one neoadjuvant chemotherapy cycle: while K(trans) (measuring mostly contrast agent (CA) extravasation) and kep (CA intravasation rate constant) decrease, τi increases. However, high-resolution, (1 mm)(2), parametric maps exhibit significant intratumor heterogeneity, which is lost by averaging. A typical 400 ms τi value means a trans-membrane water cycling flux of 10(13) H2O molecules s(-1)/cell for a 12 µm diameter cell. Analyses of intratumor variations (and therapy-induced changes) of τi in combination with concomitant changes of ve (extracellular volume fraction) indicate that the former are dominated by alterations of the equilibrium cell membrane water permeability coefficient, PW, not of cell size. These can be interpreted in light of literature results showing that τi changes are dominated by a PW (active) component that reciprocally reflects the membrane driving P-type ATPase ion pump turnover. For mammalian cells, this is the Na(+), K(+)-ATPase pump. These results promise the potential to discriminate metabolic and microenvironmental states of regions within tumors in vivo, and their changes with therapy.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/metabolismo , Espacio Intracelular/metabolismo , Imagen por Resonancia Magnética/métodos , Biomarcadores de Tumor/metabolismo , Neoplasias de la Mama/patología , Neoplasias de la Mama/terapia , Tamaño de la Célula , Medios de Contraste , Femenino , Humanos , Cinética , Permeabilidad , Agua
5.
Magn Reson Imaging ; 30(9): 1257-67, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22770687

RESUMEN

Three dimensional bilateral imaging is the standard for most clinical breast dynamic contrast-enhanced (DCE) MRI protocols. Because of high spatial resolution (sRes) requirement, the typical 1-2 min temporal resolution (tRes) afforded by a conventional full-k-space-sampling gradient echo (GRE) sequence precludes meaningful and accurate pharmacokinetic analysis of DCE time-course data. The commercially available, GRE-based, k-space undersampling and data sharing TWIST (time-resolved angiography with stochastic trajectories) sequence was used in this study to perform DCE-MRI exams on thirty one patients (with 36 suspicious breast lesions) before their biopsies. The TWIST DCE-MRI was immediately followed by a single-frame conventional GRE acquisition. Blinded from each other, three radiologist readers assessed agreements in multiple lesion morphology categories between the last set of TWIST DCE images and the conventional GRE images. Fleiss' κ test was used to evaluate inter-reader agreement. The TWIST DCE time-course data were subjected to quantitative pharmacokinetic analyses. With a four-channel phased-array breast coil, the TWIST sequence produced DCE images with 20 s or less tRes and ~ 1.0×1.0×1.4 mm(3) sRes. There were no significant differences in signal-to-noise (P=.45) and contrast-to-noise (P=.51) ratios between the TWIST and conventional GRE images. The agreements in morphology evaluations between the two image sets were excellent with the intra-reader agreement ranging from 79% for mass margin to 100% for mammographic density and the inter-reader κ value ranging from 0.54 (P<.0001) for lesion size to 1.00 (P<.0001) for background parenchymal enhancement. Quantitative analyses of the DCE time-course data provided higher breast cancer diagnostic accuracy (91% specificity at 100% sensitivity) than the current clinical practice of morphology and qualitative kinetics assessments. The TWIST sequence may be used in clinical settings to acquire high spatiotemporal resolution breast DCE-MRI images for both precise lesion morphology characterization and accurate pharmacokinetic analysis.


Asunto(s)
Neoplasias de la Mama/patología , Medios de Contraste/farmacología , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Anciano de 80 o más Años , Angiografía , Biopsia/métodos , Neoplasias de la Mama/diagnóstico , Medios de Contraste/farmacocinética , Femenino , Humanos , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Relación Señal-Ruido , Procesos Estocásticos , Factores de Tiempo
6.
Radiology ; 261(2): 394-403, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21828189

RESUMEN

PURPOSE: To assess the accuracy of the shutter-speed approach compared with standard approach dynamic contrast material-enhanced magnetic resonance (MR) imaging pharmacokinetic analysis for breast cancer diagnosis. MATERIALS AND METHODS: This study was approved by the institutional review board and was HIPAA compliant. Informed consent was obtained from 89 high-risk women (age range, 28-83 years) who had 92 suspicious lesions with negative findings at mammography (but visible at MR imaging). Each underwent a research dynamic contrast-enhanced MR imaging examination just prior to a clinical MR imaging-guided interventional procedure. Tumor region of interest (ROI) averaged and (for some) pixel-by-pixel dynamic contrast-enhanced time-course data, together with mean arterial input function, were subjected to serial standard and shutter-speed approach analyses to extract pharmacokinetic parameters, including rate constant for passive contrast reagent transfer between plasma and interstitium (K(trans)) and interstitial space volume fraction, or v(e). Pathologic findings were used as reference standards. Diagnostic accuracy was assessed with receiver operating characteristic analyses. RESULTS: The pathologic analyses revealed 20 malignant and 72 benign lesions. Positive predictive value of the institutional clinical breast MR imaging protocol was 22%. At 100% sensitivity, ROI-averaged shutter-speed approach K(trans) had significantly (P = .008) higher diagnostic specificity than standard approach K(trans): 86.1% versus 77.8%. The difference in the ROI-averaged K(trans) parameter value, or ΔK(trans) (≡ K(trans) [shutter-speed approach] - K(trans) [standard approach]), had even higher specificity (88.9%). Combined use of ROI analysis and pixel-by-pixel mapping of ΔK(trans) achieved 98.6% specificity at 100% sensitivity. CONCLUSION: The use of the shutter-speed dynamic contrast-enhanced MR imaging method has the potential to improve breast cancer diagnostic accuracy and reduce putatively unnecessary biopsy procedures that yield benign pathologic findings. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11102413/-/DC1.


Asunto(s)
Enfermedades de la Mama/patología , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de la Mama/patología , Medios de Contraste/farmacocinética , Diagnóstico Diferencial , Femenino , Gadolinio DTPA/farmacocinética , Humanos , Aumento de la Imagen/métodos , Mamografía , Persona de Mediana Edad , Curva ROC , Sensibilidad y Especificidad
7.
Proc Natl Acad Sci U S A ; 105(46): 17943-8, 2008 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-19004780

RESUMEN

The pharmacokinetic analysis of dynamic-contrast-enhanced (DCE) MRI data yields K(trans) and k(ep), two parameters independently measuring the capillary wall contrast reagent transfer rate. The almost universally used standard model (SM) embeds the implicit assumption that equilibrium transcytolemmal water exchange is effectively infinitely fast. In analyses of routine DCE-MRI data from 22 patients with suspicious breast lesions initially ruled positive by institutional screening protocols, the SM K(trans) values for benign and malignant lesions exhibit considerable overlap. A form of the shutter-speed model (SSM), which allows for finite exchange kinetics, agrees with the SM K(trans) value for each of the 15 benign lesions. However, it reveals that the SM underestimates K(trans) for each of the seven malignant tumors in this population. The fact that this phenomenon is unique to malignant tumors allows their complete discrimination from the benign lesions, as validated by comparison with gold-standard pathology analyses of subsequent biopsy tissue samples. Likewise, the SM overestimates k(ep), particularly for the benign tumors. Thus, incorporation of the SSM into the screening protocols would have precluded all 68% of the biopsy/pathology procedures that yielded benign findings. The SM/SSM difference is well understood from molecular first principles.


Asunto(s)
Neoplasias de la Mama/irrigación sanguínea , Imagen por Resonancia Magnética/instrumentación , Neoplasias de la Mama/patología , Medios de Contraste/farmacocinética , Femenino , Humanos
8.
Proc Natl Acad Sci U S A ; 105(46): 17937-42, 2008 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-19008355

RESUMEN

The passage of a vascular-injected paramagnetic contrast reagent (CR) bolus through a region-of-interest affects tissue (1)H(2)O relaxation and thus MR image intensity. For longitudinal relaxation [R(1) identical with (T(1))(-1)], the CR must have transient molecular interactions with water. Because the CR and water molecules are never uniformly distributed in the histological-scale tissue compartments, the kinetics of equilibrium water compartmental interchange are competitive. In particular, the condition of the equilibrium trans cytolemmal water exchange NMR system sorties through different domains as the interstitial CR concentration, [CR(o)], waxes and wanes. Before CR, the system is in the fast-exchange-limit (FXL). Very soon after CR(o) arrival, it enters the fast-exchange-regime (FXR). Near maximal [CR(o)], the system could enter even the slow-exchange-regime (SXR). These conditions are defined herein, and a comprehensive description of how they affect quantitative pharmacokinetic analyses is presented. Data are analyzed from a population of 22 patients initially screened suspicious for breast cancer. After participating in our study, the subjects underwent biopsy/pathology procedures and only 7 (32%) were found to have malignancies. The transient departure from FXL to FXR (and apparently not SXR) is significant in only the malignant tumors, presumably because of angiogenic capillary leakiness. Thus, if accepted, this analysis would have prevented the 68% of the biopsies that proved benign.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Medios de Contraste , Imagen por Resonancia Magnética/métodos , Neoplasias de la Mama/patología , Carcinoma Intraductal no Infiltrante/diagnóstico , Medios de Contraste/farmacocinética , Femenino , Humanos , Espectroscopía de Resonancia Magnética
9.
Radiology ; 232(2): 585-91, 2004 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-15205478

RESUMEN

PURPOSE: To prospectively determine if a combined magnetic resonance (MR) protocol that includes T1-weighted dynamic contrast agent-enhanced (DCE) MR imaging, hydrogen 1 (1H) MR spectroscopy, and T2*-weighted perfusion MR imaging improves specificity in the diagnosis of breast cancer. MATERIALS AND METHODS: The combined MR imaging-MR spectroscopy protocol was performed in 50 patients after positive findings at mammography but prior to biopsy. Single-voxel proton MR spectroscopy and perfusion MR imaging were conducted only if DCE MR images showed rapid contrast enhancement in the lesion. Biopsy results were used as the reference for comparison with MR results and for calculation of sensitivity and specificity in the detection of breast malignancy. RESULTS: DCE MR imaging alone showed 100% sensitivity and 62.5% specificity. The specificity improved to 87.5% with the addition of 1H MR spectroscopy and to 100% with the further addition of perfusion MR imaging. Twenty-eight patients underwent both MR spectroscopy and perfusion MR imaging. Two patients underwent MR spectroscopy but declined to undergo perfusion MR imaging. The remaining 20 patients had negative results at DCE MR imaging and therefore did not undergo the additional examinations. CONCLUSION: The combined MR protocol of DCE MR imaging, 1H MR spectroscopy, and perfusion MR imaging has high sensitivity and specificity in the diagnosis of breast cancer.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Aumento de la Imagen , Procesamiento de Imagen Asistido por Computador , Angiografía por Resonancia Magnética , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Mamografía , Adulto , Anciano , Biopsia , Mama/irrigación sanguínea , Mama/patología , Neoplasias de la Mama/irrigación sanguínea , Neoplasias de la Mama/patología , Medios de Contraste/administración & dosificación , Femenino , Gadolinio DTPA , Humanos , Persona de Mediana Edad , Neovascularización Patológica/diagnóstico , Neovascularización Patológica/patología , Sensibilidad y Especificidad , Técnica de Sustracción
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...