Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Arthrosc Sports Med Rehabil ; 6(2): 100888, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38356465

RESUMEN

Purpose: To investigate the simultaneous effect of 3-dimensional (3D) hinge axis (HA) orientation on alignment parameters in all 3 anatomical planes in high tibial osteotomy. Methods: A computed tomography-based 3D model of a human tibia/fibula was used to establish a 3D tibial coordinate system based on the tibial mechanical axis. In here, an HA was positioned and an opening-wedge high tibial osteotomy with a rotation angle of 10° over the HA was simulated. HA rotation in the axial plane ranged from 0° to 90° and HA tilt relative to the axial plane ranged from -20° to +20°. The study quantified the simultaneous effect of HA orientation on change of alignment parameters in all anatomical reference planes. Results: HA rotation within the tibial axial plane between orientations perpendicular to the coronal and sagittal planes primarily affected both coronal and sagittal plane alignment, with an inverse relationship between these planes (range: 0°-9.7°); the effect of HA rotation on the change in axial plane alignment was maximally 0.9°. In contrast, HA tilt relative to the tibial axial plane primarily affected axial alignment (maximum change: 6.9°); the effect on change in both coronal and sagittal plane alignment was maximally 0.6°. Conclusions: HA rotation in the tibial axial plane primarily affects sagittal and coronal plane alignment, and HA tilt relative to the tibial axial plane primarily affects axial plane alignment. Clinical Relevance: Integrating 3D HA orientation in malalignment planning and correction offers the potential to minimize unintended corrections in nontargeted planes in uniplanar correction osteotomies and to facilitate intentional multiplanar correction with a single osteotomy.

2.
J Hand Surg Eur Vol ; : 17531934231213790, 2023 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-37987680

RESUMEN

Two-dimensional (2-D) plain radiographs may be insufficient for the evaluation of distal radial malunion, as it is a three-dimensional (3-D) deformity. This study introduced a 3-D measuring method that outputs radial inclination, ulnar variance, palmar tilt and axial rotation. To this end, a standardized and clearly defined coordinate system was constructed that allowed 3-D measurements closely resembling the conventional 2-D method in 35 patients. Mean differences between 3-D and 2-D measurements in affected wrists were 1.8° for radial inclination, 0.8 mm for ulnar variance and 3.7° for palmar tilt. In addition, inter- and intra-observer reproducibility of all 3-D and 2-D measurements were good or excellent (intraclass correlation coefficient >0.75), with 3-D reproducibility always better than 2-D. Axial rotation was present in all patients with a mean of 7.9° (SD 6.9). Although the differences between 2-D and 3-D measurements were small, 3-D evaluation enables the assessment of axial rotation and brings us closer to a routine 3-D evaluation of malunion.Level of evidence: III.

3.
Anal Bioanal Chem ; 415(24): 5997-6007, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37505238

RESUMEN

The incidence of osteoarthritis (OA) has been expected to increase due to an aging population, as well as an increased incidence of intra-articular (osteo-) chondral damage. Lipids have already been shown to be involved in the inflammatory process of OA. This study aims at revealing region-specific lipid profiles of the infrapatellar fat pad (IPFP) of OA or cartilage defect patients by matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI), which could be used as biomarkers for early OA detection. A higher presence of phospholipids was found in OA patients compared with cartilage defect patients. In addition, a higher abundance of ether-linked phosphatidylethanolamines (PE O-s) containing arachidonic acid was specifically found in OA patients compared with cartilage defect patients. These lipids were mainly found in the connective tissue of the IPFP. Specific lipid species were associated to OA patients compared with cartilage defect patients. PE O-s have been suggested as possible biomarkers for OA. As these were found more abundantly in the connective tissue, the IPFP's intra-tissue heterogeneity might play an important role in biomarker discovery, implying that the amount of fibrous tissue is associated with OA.


Asunto(s)
Osteoartritis de la Rodilla , Humanos , Anciano , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/patología , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Tejido Adiposo/patología , Biomarcadores , Biopsia , Cartílago/patología , Lípidos , Rayos Láser
4.
Disabil Rehabil Assist Technol ; : 1-9, 2023 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-36897133

RESUMEN

PURPOSE: To interpret the Medical Device Regulation for occupational therapists in the Netherlands involved in prescribing and manufacturing custom-made assistive devices and to develop a roadmap for implementation. MATERIALS AND METHODS: Four online iterative co-design workshops were organized under supervision of a senior quality manager to assist in the interpretation of the MDR framework with a focus on custom-made assistive devices; and to assist the implementation by generating guidelines and forms. The workshops for seven participating occupational therapists had an interactive character with Q&A, small and homework assignments, and oral evaluations. Next to occupational therapists, participants with different backgrounds joined such as 3D printing experts, engineers, managers, and researchers. RESULTS: The participants experienced the interpretation of the MDR as informative, but also as complex . Complying with the MDR requires considerable documentation activities that are currently not part of care professionals tasks. This initially raised concerns regarding implementation in daily practice. To facilitate the MDR implementation, forms were created and evaluated for a selected design case together with the participants for future reference. Additionally, instructions were given which forms should be filled out only once per organization, which forms could be reused for similar types of custom-made devices, and which forms should be filled out for each individual custom-made device. CONCLUSIONS: This study provides practical guidelines and forms to support occupational therapists in the Netherlands to prescribe and manufacture custom-made medical devices complying with the MDR. It is recommended to involve engineers and/or quality managers in this process.IMPLICATIONS FOR REHABILITATIONOccupational therapists are considered legal manufacturer when they prescribe and manufacture custom-made medical devices for their clients. As such they are legally obliged to meet the Medical Device Regulation (MDR).When designing and manufacturing "in-house" custom-made medical devices, care organizations need to follow and document activities to demonstrate compliance with the MDR. This study offers practical guidelines and forms to facilitate this.

5.
Life (Basel) ; 13(2)2023 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-36836713

RESUMEN

BACKGROUND: In vivo diffuse reflectance spectroscopy provides additional contrast in discriminating nerves embedded in adipose tissue during surgery. However, large datasets are required to achieve clinically acceptable classification levels. This study assesses the spectral similarity between ex vivo porcine and in vivo human spectral data of nerve and adipose tissue, as porcine tissue could contribute to generate large datasets. METHODS: Porcine diffuse reflectance spectra were measured at 124 nerve and 151 adipose locations. A previously recorded dataset of 32 in vivo human nerve and 23 adipose tissue locations was used for comparison. In total, 36 features were extracted from the raw porcine to generate binary logistic regression models for all combinations of two, three, four and five features. Feature selection was performed by assessing similar means between normalized features of nerve and of adipose tissue (Kruskal-Wallis test, p < 0.05) and for models performing best on the porcine cross validation set. The human test set was used to assess classification performance. RESULTS: The binary logistic regression models with selected features showed an accuracy of 60% on the test set. CONCLUSIONS: Spectral similarity between ex vivo porcine and in vivo human adipose and nerve tissue was present, but further research is required.

6.
Rheumatol Int ; 43(10): 1767-1779, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-36513849

RESUMEN

For knee osteoarthritis and related conditions, analysis of biomarkers hold promise to improve early diagnosis and/or offer patient-specific treatment. To compare biomarker analyses, reliable, high-quality biopsies are needed. The aim of this work is to summarize the literature on the current best practices of biopsy of the synovium and synovial fluid arthrocentesis. Therefore, PubMed, Embase and Web of Science were systematically searched for articles that applied, demonstrated, or evaluated synovial biopsies or arthrocentesis. Expert recommendations and applications were summarized, and evidence for superiority of techniques was evaluated. Thirty-one studies were identified for inclusion. For arthrocentesis, the superolateral approach in a supine position, with a 0°-30° knee flexion was generally recommended. 18-gage needles, mechanical compression and ultrasound-guidance were found to give superior results. For blind and image-guided synovial biopsy techniques, superolateral and infrapatellar approaches were recommended. Single-handed tools were preconized, including Parker-Pearson needles and forceps. Sample quantity ranged approximately from 2 to 20. Suggestions were compiled for arthrocentesis regarding approach portal and patient position. Further evidence regarding needle size, ultrasound-guidance and mechanical compression were found. More comparative studies are needed before evidence-based protocols can be developed.


Asunto(s)
Artrocentesis , Líquido Sinovial , Humanos , Artrocentesis/métodos , Articulación de la Rodilla/diagnóstico por imagen , Biopsia , Membrana Sinovial/diagnóstico por imagen
7.
Anal Biochem ; 662: 115018, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36521559

RESUMEN

Mass spectrometry imaging (MSI) is a powerful technique enabling the visualization of the spatial distribution of different molecules in tissue biopsies with different pathologies. Sample handling and preparing adipose tissue for MSI is challenging and prone to molecular delocalization due to tissue melting. In this work, we developed a method for matrix-assisted laser desorption/ionization (MALDI)-MSI to study lipids in human infrapatellar fat pad (IPFP), a biomarker source in musculoskeletal pathologies, while preserving molecular spatial distribution. Cryosectioning at 15 µm with a temperature below -30 °C, thaw-mounting, and sublimation, was demonstrated to preserve IPFP's heterogeneous appearance and spatial distribution of lipids.


Asunto(s)
Diagnóstico por Imagen , Manejo de Especímenes , Humanos , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Lípidos/análisis , Rayos Láser
8.
Foot Ankle Orthop ; 7(3): 24730114221112945, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35898795

RESUMEN

Background: The objective consisted of 2 elements, primarily to define 2 bone geometry variations of the ankle that may be of prognostic value on ankle instability and secondly to translate these bone variations from a 3D model to a simple 2D radiographic measurement for clinical use. Methods: The 3D tibial and talar shape differences derived from earlier studies were translated to two 2D radiographic parameters: the medial malleolar height angle (MMHA) and talar convexity angle (TCA) respectively to ensure clinical use. To assess validity, the MMHA and TCA were measured on 3D polygons derived from lower leg computed tomographic (CT) scans and 2D digitally reconstructed radiographs (DRRs) of these polygons. To assess reliability, the MMHA and TCA were measured on standard radiographs by 2 observers calculating the intraclass correlation coefficient (ICC). Results: The 3D angle measurements on the polygons showed substantial to excellent agreement with the 2D measurements on DRR for both the MMHA (ICC 0.84-0.93) and TCA (ICC 0.88-0.96). The interobserver reliability was moderate with an ICC of 0.58 and an ICC of 0.64 for both the MMHA and TCA, respectively. The intraobserver reliability was excellent with an ICC of 0.96 and 0.97 for the MMHA and the TCA, respectively. Conclusion: Two newly defined radiographic parameters (MMHA and TCA) are valid and can be assessed with excellent intraobserver reliability on standard radiographs. The interobserver reliability was moderate and indicates training is required to ensure uniformity in measurement technique. The current method may be used to translate more variations in bone shape prior to implementation in clinical practice. Level of Evidence: Level III, cohort study.

9.
J Am Soc Mass Spectrom ; 33(1): 111-122, 2022 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-34882413

RESUMEN

The analysis of samples with large height variations remains a challenge for mass spectrometry imaging (MSI), despite many technological advantages. Ambient sampling and ionization MS techniques allow for the molecular analysis of sample surfaces with height variations, but most techniques lack MSI capabilities. We developed a 3D MS scanner for the automated sampling and imaging of a 3D surface with laser-assisted rapid evaporative ionization mass spectrometry (LA-REIMS). The sample is moved automatically with a constant distance between the laser probe and sample surface in the 3D MS Scanner. The topography of the surface was scanned with a laser point distance sensor to define the MS measurement points. MS acquisition was performed with LA-REIMS using a surgical CO2 laser coupled to a qTOF instrument. The topographical scan and MS acquisition can be completed within 1 h using the 3D MS scanner for 300 measurement points on uneven samples with a spatial resolution of 2 mm in the top view, corresponding to 22.04 cm2. Comparison between the automated acquisition with the 3D MS scanner and manual acquisition by hand showed that the automation resulted in increased reproducibility between the measurement points. 3D visualizations of molecular distributions related to structural differences were shown for an apple, a marrowbone, and a human femoral head to demonstrate the imaging feasibility of the system. The developed 3D MS scanner allows for the automated sampling of surfaces with uneven topographies with LA-REIMS, which can be used for the 3D visualization of molecular distributions of these surfaces.

10.
Expert Rev Proteomics ; 18(8): 693-706, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34228576

RESUMEN

INTRODUCTION: Knee osteoarthritis (OA) is a joint disease, affecting multiple tissues in the joint. Early detection and intervention may delay OA development and avoid total knee arthroplasty. Specific biomarker profiles for early detection and guiding clinical decision-making of OA have not yet been identified. One technique that can contribute to the finding of this 'OA biomarker' is mass spectrometry (MS), which offers the possibility to analyze different molecules in tissues or fluids. Several proteomic, lipidomic, metabolomic and other - omic approaches aim to identify these molecular profiles; however, variation in methods and techniques complicate the finding of promising candidate biomarkers. AREAS COVERED: In this systematic review, we aim to provide an overview of molecules in knee OA patients. Possible biomarkers in several tissue types of OA and non-OA patients, as well as current limitations and possible future suggestions will be discussed. EXPERT OPINION: According to this review, we do not believe one specific biomarker will function as predictive molecule for OA. Likely, a group of molecules will give insight in OA development and possible therapeutic targets. For clinical implementation of MS-analysis in clinical decision-making, standardized procedures, large cohort studies and sharing protocols and data is necessary.


Asunto(s)
Osteoartritis de la Rodilla , Tejido Adiposo , Biomarcadores , Humanos , Articulación de la Rodilla , Espectrometría de Masas , Proteómica
11.
J Mech Behav Biomed Mater ; 113: 104157, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33187871

RESUMEN

OBJECTIVES: Reconstruction plates, used to bridge segmental defects of the mandible after tumor resection or traumatic bone tissue loss, are subjected to repeated stresses of mastication. High stress concentrations in these plates can result in hardware failure. Topology optimization (TO) could reduce the peak stress by computing the most optimal material distribution in a patient-specific implant (PSI) used for mandibular reconstruction. The objective of this study was biomechanical validation of a TO-PSI. METHODS: A computer-aided design (CAD) model with a segmental defect was created based on the geometry of a polyurethane mandible model. A standard-PSI was designed to bridge the defect. A TO-PSI was then designed with a maximum stress equal to the ultimate tensile stress of Ti6Al4V (930 MPa) during a loading condition of 378 N. Finite element analysis (FEA) was used to analyze stresses in both PSI designs during loading. The standard-PSI and TO-PSI designs were produced in triplicate by selective laser melting of Ti6Al4V, fixated to polyurethane mandible models with segmental defects identical to the CAD model, and subsequently subjected to continuous compression with a speed of 1 mm/min on a universal testing machine, while recording the load. Peak loads before failure in the TO-PSI group within a 30% range of the predicted peak load (378 N) were considered a successful biomechanical validation. RESULTS: Fracture of the TO-PSI occurred at a median peak load of 334 N (range 304-336 N). These values are within the 30% range of the predicted peak load. Fracture of the mandible model in the standard-PSI group occurred at a median peak load of 1100 N (range 1010-1460 N). Failure locations during biomechanical testing of TO-PSI and standard-PSI samples corresponded to regions in the FEA where stresses exceeded the ultimate tensile strength of titanium and polyurethane, respectively. CONCLUSION: This study demonstrates a successful preliminary biomechanical validation of TO in the design process for mandibular reconstruction plates. Further work is needed to refine the finite element model, which is necessary to ultimately design TO-PSIs for clinical use.


Asunto(s)
Reconstrucción Mandibular , Fenómenos Biomecánicos , Placas Óseas , Análisis de Elementos Finitos , Humanos , Mandíbula , Estrés Mecánico
12.
Cartilage ; 13(2_suppl): 1627S-1636S, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-31646879

RESUMEN

OBJECTIVE: Surgical microfracture is considered a first-line treatment for talar osteochondral defects. However, current rigid awls and drills limit access to all locations in human joints and increase risk of heat necrosis of bone. Using a flexible water jet instrument to drill holes can improve the reachability of the defect without inducing thermal damage. The aim of this feasibility study is to determine whether water jet drilling is potentially safe compared with conventional microfracture awls by studying side effects and perioperative complications, as well as the quality of cartilage repair tissue. DESIGN: Talar chondral defects with 6-mm diameter were created bilaterally in 6 goats (12 samples). One defect in each goat was treated with microfracture created with conventional awls, the contralateral defect was treated with holes created with 5-second water jet bursts at a pressure of 50 MPa. Postoperative complications were recorded and after 24 weeks analyses were performed using the ICRS (International Cartilage Repair Society) macroscopic score and modified O'Driscoll histological score. RESULTS: Several practical issues using the water jet in the operating theatre were noted. Water jet drilling resulted in fibrocartilage repair tissue similar to the repair tissue from conventional awls. CONCLUSIONS: These results suggest that water jet drilling gives adequate fibrocartilage repair tissue. Furthermore, the results highlight essential prerequisites for safe application of surgical water jet drilling: stable water pressure, water jet beam coherence, stable positioning of the nozzle head when jetting, and minimizing excessive fluid extravasation.


Asunto(s)
Enfermedades de los Cartílagos , Fracturas por Estrés , Animales , Enfermedades de los Cartílagos/cirugía , Estudios de Factibilidad , Cabras , Agua
13.
JSES Int ; 4(4): 1031-1036, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33345253

RESUMEN

PURPOSE: Ulnar nerve injury is the most common neurologic complication of elbow arthroscopy. The purpose of this cadaveric study was to quantify the ability of surgeons to locate the ulnar nerve behind the posteromedial capsule during elbow arthroscopy using sole arthroscopic vision. METHODS: Twenty-one surgeons were asked to pin the ulnar nerve at the medial gutter and the posteromedial compartment using arthroscopic visualization of the medial capsule only. Pinning of the ulnar nerve was performed from extra-articular. Then, the cadaveric specimens were dissected and the shortest distances between the pins and ulnar nerve measured. RESULTS: Median pin-to-nerve distances at the medial gutter and posteromedial compartment were 0 mm (interquartile range [IQR], 0-3 mm) and 2 mm (IQR, 0-6 mm), respectively. The ulnar nerve was pinned by 11/21 surgeons (52%) at the medial gutter, and 7/21 surgeons (33%) at the posteromedial compartment. Three of 21 surgeons (14%) pinned the ulnar nerve at both the medial gutter and the posteromedial compartment. Surgeon's experience and operation volume did not affect these outcomes (P > .05). CONCLUSIONS: Surgeons' ability to locate the ulnar nerve behind the posteromedial capsule using sole arthroscopic visualization, without external palpation, is poor. We recommend to proceed carefully when performing arthroscopic procedures in the posteromedial elbow, and identify and mobilize the ulnar nerve prior to any posteromedial capsular procedures.

14.
Arthroscopy ; 35(8): 2385-2390, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31053458

RESUMEN

PURPOSE: To determine the face and construct validity as well as educational value and user-friendliness of the Simendo knee arthroscopy virtual reality simulator. METHODS: Sixty participants were recruited and equally divided into novices (0 arthroscopic procedures), intermediates (1-59 arthroscopic procedures), and experts (60 or more arthroscopic procedures). Participants were excluded if they had previously trained with the studied simulator. Construct validity, that is, the ability to discriminate between different levels of expertise, was examined by a navigation task. All participants were asked to perform 5 navigation trials within 10 minutes. Face validity, educational value, and user-friendliness were examined by questionnaires before and after the navigation trials. Face validity is the subjective impression of how closely the simulation replicates the real environment. RESULTS: The novices were significantly slower than the intermediates in the first (P < .001) and the third (P = .031) trial. The novices were significantly slower than the experts in all trials (P = .016), except for the fifth (P = .054). The experts were significantly faster than the intermediates in every trial except for the fourth (P = .069). Median task time for the fifth trial was 63 seconds (44-80 seconds) for novices, 58 seconds (46-80 seconds) for intermediates, and 41 seconds (33-55 seconds) for experts. Ninety-two percent of all participants agreed that the simulator can be used to train for surgical inspection, and 95% indicated sufficient user-friendliness. CONCLUSIONS: Based on the results, this knee simulator can be applied to train the basic arthroscopic hand-eye coordination skills at the start of resident education programs. Further testing is necessary to determine whether the skills are retained. CLINICAL RELEVANCE: The simulator is partly validated, which contributes to training of basic arthroscopic skills without compromising patient safety.


Asunto(s)
Artroscopía/métodos , Articulación de la Rodilla/cirugía , Realidad Virtual , Adulto , Competencia Clínica , Simulación por Computador , Diseño de Equipo , Femenino , Humanos , Internado y Residencia , Masculino , Persona de Mediana Edad , Seguridad del Paciente , Examen Físico , Reproducibilidad de los Resultados , Encuestas y Cuestionarios , Interfaz Usuario-Computador , Adulto Joven
15.
J Orthop Res ; 37(9): 1892-1902, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31042001

RESUMEN

Bone shapes, particularly those defining the subtalar joint (STJ), have not received much attention yet as a risk factor for developing chronic ankle instability (CAI) after sustaining a lateral ankle sprain (LAS). This study aimed to compare three-dimensional (3D) shape variations in the STJ bones within individuals with CAI and healthy controls. 3D statistical shape models (SSMs) of the STJ bones were built to describe the bone shape variations observed within a population consisting of 26 individuals with unilateral CAI and 26 healthy controls. Using the SSMs and analysis of covariance test, age- and gender-adjusted shape variations in the bones were compared within individuals with CAI and healthy controls. The mean age of the CAI patients (14 males and 12 females) and healthy controls (12 males and 14 females) was 29 (standard deviation [SD] = 11) and 36 years (SD = 11), respectively. Tali and calcanei did not significantly vary between ipsilateral CAI and their contralateral ankle. Two shape modes, one for the talus (p = 0.015, variations in the curvature of the talar lateral process and the inclination angle of the talar neck relative to the body) and one for the calcaneus (p = 0.003, variations in the medial and lateral tuberosities, and the contour of the anterior articular surface), described significant shape differences between the CAI patients and healthy controls. The CAI patients generally had flatter talar joint surfaces and a flattened calcaneal ground-contact surface. These findings suggest that specific bone shapes may increase the risk of developing CAI after sustaining a LAS. © 2019 The Authors. Journal of Orthopaedic Research® Published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society. J Orthop Res 37:1892-1902, 2019.


Asunto(s)
Articulación del Tobillo , Inestabilidad de la Articulación/patología , Articulación Talocalcánea/anatomía & histología , Adolescente , Adulto , Calcáneo/anatomía & histología , Enfermedad Crónica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Astrágalo/anatomía & histología , Adulto Joven
16.
J Anat ; 234(1): 132-144, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30393864

RESUMEN

The bones forming the talocrural joint (TCJ) and subtalar joint (STJ) are often assumed to be bilaterally symmetric. Therefore, the contralateral limb (i.e. the fibula, tibia, calcaneus and talus) is used as a template or an intra-subject control in clinical and research practice. However, the validity of the symmetry assumption is controversial, because insufficient information is available on the shape variations and bilateral (a)symmetry of the fibula, tibia, calcaneus and talus. Using three-dimensional spatially dense sampled representations of bone shapes extracted from bilateral computed tomography scans of 66 individuals (55 male, mean age: 61 ±â€…10 years; 11 female, mean age: 53 ±â€…15 years), we analyzed whether: (i) similar shape patterns exist in the left and right bones of the same type; (ii) gender has an effect on bone shape variations; (iii) intra-subject shape variation is smaller than that of inter-subject for a given shape variance direction. For the first set of analyses, all left and right instances of the same type of bone were considered as two separate groups, and statistically compared with each other on multiple aspects including group location (central tendency), variance-covariance scale (dispersion) and orientation (covariance structure) using distance-based permutational tests. For the second and third sets of analyses, all left and right bones of the same type were pooled into one group, and shape variations in the TCJ and STJ bones were extracted using principal component analysis. The effects of gender on age-adjusted bone shape differences were assessed using an analysis of covariance. Moreover, intra-class correlation was employed to evaluate intra- and inter-subject bone shape variations. For each bone type, both sides had similar shape patterns (Ppermutational -values > 0.05). After Bonferroni adjustment, gender led to shape differences, which were mainly in the lateral and medial condyles of the tibia (P = 0.003), the length and height of the calcaneus (P < 0.001), the posterior and anterior talar articular surfaces of the calcaneus (P = 0.001), and in the posterior aspect of the talus (P = 0.001). Intra-subject shape variations in the tibial tuberosity together with the diameter of the tibia, and the curvature of the fibula shaft and the diameter of the fibula were as high as those of inter-subject. This result suggests that the shape symmetry assumption could be violated for some specific shape variations in the fibula and tibia.


Asunto(s)
Calcáneo/anatomía & histología , Peroné/anatomía & histología , Imagenología Tridimensional/métodos , Astrágalo/anatomía & histología , Tibia/anatomía & histología , Adulto , Anciano , Calcáneo/diagnóstico por imagen , Femenino , Peroné/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Astrágalo/diagnóstico por imagen , Tibia/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos
17.
J Exp Orthop ; 5(1): 45, 2018 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-30315425

RESUMEN

BACKGROUND: Elbow arthroscopy is a difficult surgical technique. Objective metrics can be used to improve safe and effective training in elbow arthroscopy. Force exerted on the elbow tissue during arthroscopy can be a measure of safe tissue manipulation. The purpose of this study was to determine the force magnitude and force direction used by experts during arthroscopic elbow navigation in cadaveric specimens and assess their applicability in elbow arthroscopy training. METHODS: Two cadaveric elbows were mounted on a Force Measurement Table (FMT) that allowed 3-dimensional measurements (x-, y-, and z-plane) of the forces exerted on the elbow. Five experts in elbow arthroscopy performed arthroscopic navigation once in each of two cadaveric elbows, navigating through the posterior, posterolateral and anterior compartment in a standardized fashion with visualization of three to four anatomic landmarks per compartment. The total absolute force (Fabs) and force direction exerted (α and ß) on the elbow during arthroscopy were recorded. α being the angle in the horizontal plane and ß being the angle in the vertical plane. The 10th-90th percentiles of the data were used to set threshold levels for training. RESULTS: The median Fabs was 24 N (19 N - 30 N), 27 N (20 N - 33 N) and 29 N (23 N - 32 N) for the posterior, posterolateral and anterior compartment, respectively. The median α was - 29° (- 55° - 5°), - 23° (- 56° - -1°) and 4° (- 22° - -18°) for the posterior, posterolateral and anterior compartment, respectively. The median ß was - 71° (- 80° - -65°), - 76° (- 86° - -69°) and - 75° (- 81° - -71°) for the posterior, posterolateral and anterior compartment, respectively. CONCLUSION: Expert data on force magnitude and force direction exerted on the elbow during arthroscopic navigation in cadaveric specimens were collected. The proposed maximum allowable force of 30 N (smallest 90th percentile of Fabs) exerted on the elbow tissue, and the 10th-90th percentile range of the force directions (α and ß) for each compartment may be used to provide objective feedback during arthroscopic skills training.

18.
Sensors (Basel) ; 18(7)2018 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-30037099

RESUMEN

A rigid surface⁻volume registration scheme is presented in this study to register computed tomography (CT) and free-hand tracked ultrasound (US) images of the talocrural joint. Prior to registration, bone surfaces expected to be visible in US are extracted from the CT volume and bone contours in 2D US data are enhanced based on monogenic signal representation of 2D US images. A 3D monogenic signal data is reconstructed from the 2D data using the position of the US probe recorded with an optical tracking system. When registering the surface extracted from the CT scan to the monogenic signal feature volume, six transformation parameters are estimated so as to optimize the sum of monogenic signal features over the transformed surface. The robustness of the registration algorithm was tested on a dataset collected from 12 cadaveric ankles. The proposed method was used in a clinical case study to investigate the potential of US imaging for pre-operative planning of arthroscopic access to talar (osteo)chondral defects (OCDs). The results suggest that registrations with a registration error of 2 mm and less is achievable, and US has the potential to be used in assessment of an OCD' arthroscopic accessibility, given the fact that 51% of the talar surface could be visualized.


Asunto(s)
Articulación del Tobillo/diagnóstico por imagen , Imagenología Tridimensional/métodos , Tomografía Computarizada por Rayos X , Ultrasonografía , Algoritmos , Humanos , Países Bajos
19.
J Mech Behav Biomed Mater ; 62: 495-503, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-27288662

RESUMEN

Using water jets for orthopedic procedures that require bone drilling can be beneficial due to the absence of thermal damage and the always sharp cut. Previously, the influence of the water jet diameter and bone architectural properties on the drilling depth have been determined. To develop water jet instruments that can safely drill in orthopedic surgery, the impact of the two remaining primary factors were determined: the jet time (tjet [s]) and pressure (P [MPa]). To this end, 84 holes were drilled in porcine tali and femora with water jets using Ø 0.4mm nozzle. tjet was varied between 1, 3 and 5s and P between 50 and 70MPa. Drilling depths Lhole (mm), diameters Dhole (mm) and the volume of mineralized bone per unit volume (BV/TV) were determined with microCT scans. A non-linear regression analysis resulted in the predictive equation: Lhole= 0.22 * tjet(0.18) * (1.2-BV/TV) * (P-29) (R(2)=0.904). The established relation between the machine settings and drilling depth allows surgeons to adjust jet time and pressure for the patient׳s BV/TV to drill holes at a predetermined depth. For developers, the relation allows design decisions to be made that influence the dimensions, flexibility and accuracy of water jet instruments. For a pressure of 50MPa, the potential hole depth spread indicated by the 95% confidence interval is <1.6mm for all tested jet times. This maximum variance is smaller than the accuracy required for bone debridement treatments (2-4mm deep), which confirms that water jet drilling can be applied in orthopedic surgery to drill holes in bone with controlled depth.


Asunto(s)
Huesos , Procedimientos Ortopédicos/métodos , Animales , Desbridamiento , Humanos , Presión , Porcinos , Factores de Tiempo , Microtomografía por Rayos X
20.
Am J Sports Med ; 44(1): 171-6, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26589838

RESUMEN

BACKGROUND: A new type of ankle brace (EXO-L) has recently been introduced. It is designed to limit the motion of most sprains without limiting other motions and to overcome problems such as skin irritation associated with taping or poor fit in the sports shoe. PURPOSE: To evaluate the claimed functionality of the new ankle brace in limiting only the motion of combined inversion and plantar flexion. STUDY DESIGN: Controlled laboratory study. METHODS: In 12 patients who received and used the new ankle brace, the mobility of the joints was measured with a highly accurate and objective in vivo 3-dimensional computed tomography (3D CT) stress test. Primary outcomes were the ranges of motion as expressed by helical axis rotations without and with the ankle brace between the following extreme positions: dorsiflexion to plantar flexion, and combined eversion and dorsiflexion to combined inversion and plantar flexion. Rotations were acquired for both talocrural and subtalar joints. A paired Student t test was performed to test the significance of the differences between the 2 conditions (P ≤ .05). RESULTS: The use of the ankle brace significantly restricted the rotation of motion from combined eversion and dorsiflexion to combined inversion and plantar flexion in both the talocrural (P = .004) and subtalar joints (P < .001). No significant differences were found in both joints for the motion from dorsiflexion to plantar flexion. CONCLUSION: The 3D CT stress test confirmed that under static and passive testing conditions, the new ankle brace limits the inversion-plantar flexion motion that is responsible for most ankle sprains without limiting plantar flexion or dorsiflexion. CLINICAL RELEVANCE: This test demonstrated its use in the objective evaluation of braces.


Asunto(s)
Traumatismos del Tobillo/fisiopatología , Tirantes , Adulto , Traumatismos del Tobillo/diagnóstico por imagen , Traumatismos del Tobillo/terapia , Articulación del Tobillo/diagnóstico por imagen , Articulación del Tobillo/fisiología , Fenómenos Biomecánicos , Diseño de Equipo , Prueba de Esfuerzo/métodos , Femenino , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Rango del Movimiento Articular/fisiología , Rotación , Zapatos , Articulación Talocalcánea/diagnóstico por imagen , Articulación Talocalcánea/fisiología , Huesos Tarsianos/diagnóstico por imagen , Huesos Tarsianos/fisiopatología , Tomografía Computarizada por Rayos X , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...