Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Phys Rev E ; 100(4-1): 043207, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31770899

RESUMEN

The free-free opacity in dense systems is a property that both tests our fundamental understanding of correlated many-body systems, and is needed to understand the radiative properties of high energy-density plasmas. Despite its importance, predictive calculations of the free-free opacity remain challenging even in the condensed matter phase for simple metals. Here we show how the free-free opacity can be modelled at finite-temperatures via time-dependent density functional theory, and illustrate the importance of including local field corrections, core polarization, and self-energy corrections. Our calculations for ground-state Al are shown to agree well with experimental opacity measurements performed on the Artemis laser facility across a wide range of extreme ultraviolet wavelengths. We extend our calculations across the melt to the warm-dense matter regime, finding good agreement with advanced plasma models based on inverse bremsstrahlung at temperatures above 10 eV.

2.
Rev Sci Instrum ; 85(10): 103117, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25362381

RESUMEN

We present a simple electron time of flight spectrometer for time resolved photoelectron spectroscopy of liquid samples using a vacuum ultraviolet (VUV) source produced by high-harmonic generation. The field free spectrometer coupled with the time-preserving monochromator for the VUV at the Artemis facility of the Rutherford Appleton Laboratory achieves an energy resolution of 0.65 eV at 40 eV with a sub 100 fs temporal resolution. A key feature of the design is a differentially pumped drift tube allowing a microliquid jet to be aligned and started at ambient atmosphere while preserving a pressure of 10(-1) mbar at the micro channel plate detector. The pumping requirements for photoelectron (PE) spectroscopy in vacuum are presented, while the instrument performance is demonstrated with PE spectra of salt solutions in water. The capability of the instrument for time resolved measurements is demonstrated by observing the ultrafast (50 fs) vibrational excitation of water leading to temporary proton transfer.


Asunto(s)
Espectroscopía de Fotoelectrones/instrumentación , Soluciones/química , Rayos Ultravioleta , Vacio , Calibración , Diseño de Equipo , Factores de Tiempo
3.
Phys Chem Chem Phys ; 14(18): 6289-97, 2012 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-22322861

RESUMEN

Laser induced acoustic desorption (LIAD) has been used for the first time to study the parent ion production and fragmentation mechanisms of a biological molecule in an intense femtosecond (fs) laser field. The photoacoustic shock wave generated in the analyte substrate (thin Ta foil) has been simulated using the hydrodynamic HYADES code, and the full LIAD process has been experimentally characterised as a function of the desorption UV-laser pulse parameters. Observed neutral plumes of densities >10(9) cm(-3) which are free from solvent or matrix contamination demonstrate the suitability and potential of the source for studying ultrafast dynamics in the gas phase using fs laser pulses. Results obtained with phenylalanine show that through manipulation of fundamental femtosecond laser parameters (such as pulse length, intensity and wavelength), energy deposition within the molecule can be controlled to allow enhancement of parent ion production or generation of characteristic fragmentation patterns. In particular by reducing the pulse length to a timescale equivalent to the fastest vibrational periods in the molecule, we demonstrate how fragmentation of the molecule can be minimised whilst maintaining a high ionisation efficiency.


Asunto(s)
Acústica , Gases/química , Rayos Láser , Fenilalanina/química , Temperatura , Cinética , Tantalio/química
4.
Phys Rev Lett ; 107(17): 177402, 2011 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-22107580

RESUMEN

We use time- and angle-resolved photoemission spectroscopy with sub-30-fs extreme-ultraviolet pulses to map the time- and momentum-dependent electronic structure of photoexcited 1T-TaS(2). This compound is a two-dimensional Mott insulator with charge-density wave ordering. Charge order, evidenced by splitting between occupied subbands at the Brillouin zone boundary, melts well before the lattice responds. This challenges the view of a charge-density wave caused by electron-phonon coupling and Fermi-surface nesting alone, and suggests that electronic correlations play a key role in driving charge order.

5.
Rev Sci Instrum ; 82(4): 043103, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21528991

RESUMEN

In this paper an algorithm for extracting spectral information from signals containing a series of narrow periodic impulses is presented. Such signals can typically be acquired by pickup detectors from the image-charge of ion bunches oscillating in a linear electrostatic ion trap, where frequency analysis provides a scheme for high-resolution mass spectrometry. To provide an improved technique for such frequency analysis, we introduce the CHIMERA algorithm (Comb-sampling for High-resolution IMpulse-train frequency ExtRAaction). This algorithm utilizes a comb function to generate frequency coefficients, rather than using sinusoids via a Fourier transform, since the comb provides a superior match to the data. This new technique is developed theoretically, applied to synthetic data, and then used to perform high resolution mass spectrometry on real data from an ion trap. If the ions are generated at a localized point in time and space, and the data is simultaneously acquired with multiple pickup rings, the method is shown to be a significant improvement on Fourier analysis. The mass spectra generated typically have an order of magnitude higher resolution compared with that obtained from fundamental Fourier frequencies, and are absent of large contributions from harmonic frequency components.

6.
Opt Express ; 18(7): 6853-62, 2010 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-20389704

RESUMEN

We report observations and analysis of high harmonic generation driven by a superposition of fields at 1290 nm and 780 nm. These fields are not commensurate in frequency and the superposition leads to an increase in the yield of the mid-plateau harmonics of more than two orders of magnitude compared to using the 1290 nm field alone. Significant extension of the cut-off photon energy is seen even by adding only a small amount of the 780 nm field. These observations are explained by calculations performed in the strong field approximation. Most importantly we find that enhancement is found to arise as a consequence of both increased ionization in the sum-field and modification of the electron trajectories leading to an earlier return time. The enhanced yield even when using modest intensity fields of 5 x 10(13) Wcm(-2) is extended to the 80 eV range and is a promising route to provide a greater photon number for applications in XUV imaging and time-resolved experiments at a high repetition rate.


Asunto(s)
Óptica y Fotónica , Óxido de Aluminio/química , Campos Electromagnéticos , Electrones , Diseño de Equipo , Iones , Rayos Láser , Dinámicas no Lineales , Distribución Normal , Fotones , Física/métodos , Titanio/química
7.
Opt Express ; 18(3): 3174-80, 2010 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-20174156

RESUMEN

The emerging techniques of molecular spectroscopy by high order harmonic generation have hitherto been conducted only with Ti:Sapphire lasers which are restricted to molecules with high ionization potentials. In order to gain information on the molecular structure, a broad enough range of harmonics is required. This implies using high laser intensities which would saturate the ionization of most molecular systems of interest, e.g. organic molecules. Using a laser at 1300 nm, we are able to extend the technique to molecules with relatively low ionization potentials (approximately 11 eV), observing wide harmonic spectra reaching up to 60 eV. This energy range improves spatial resolution of the high harmonic spectroscopy to the point where interference minima in harmonic spectra of N(2)O and C(2)H(2) can be observed.

8.
Phys Rev Lett ; 98(20): 203007, 2007 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-17677693

RESUMEN

The effects of electronic structure and symmetry are observed in laser driven high-order harmonic generation for laser aligned conjugated polyatomic molecular systems. The dependence of the harmonic yield on the angle between the molecular axis and the polarization of the driving laser field is seen to contain the fingerprint of the highest occupied molecular orbitals in acetylene and allene, a good quantitative agreement with calculations employing the strong field approximation was found. These measurements support the extension of the recently proposed molecular orbital imaging techniques beyond simple diatomic molecules to larger molecular systems.

9.
Phys Rev Lett ; 98(16): 163001, 2007 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-17501417

RESUMEN

The experimental study of molecular dissociation of H2+ by intense laser pulses is complicated by the fact that the ions are initially produced in a wide range of vibrational states, each of which responds differently to the laser field. An electrostatic storage device has been used to radiatively cool HD+ ions enabling the observation of above threshold dissociation from the ground vibrational state by 40 fs laser pulses at 800 nm. At the highest intensities used, dissociation through the absorption of at least four photons is found to be the dominant process.

10.
Phys Med Biol ; 47(19): 3543-55, 2002 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-12408481

RESUMEN

The efficiency of producing biological damage varies with radiation quality. Conventional explanations rely on spatial differences in the radiation track structure; generally however there are also very large temporal differences in delivery of the radiation at the cellular level. High-LET radiation normally deposits substantial amounts of energy by individual heavily ionizing tracks on a timescale of the order of picoseconds. By contrast each low-LET radiation track deposits a small amount of energy. Many of these tracks, distributed over the whole cell, are required to deliver an equivalent dose to a high-LET track and they are usually delivered over much longer timescales (typically seconds) during which chemical, biochemical and biological processes are occurring. In this paper the design, characterization and initial application of a high-brightness, laser-plasma ultrasoft x-ray source is described. This has been used to investigate the importance of the temporal differences by irradiating mammalian cells with an energy deposition with spatial properties of low-LET radiation and temporal properties similar to high-LET radiation. The present system delivers a typical dose, to the incident surface of the cells, of 0.12 Gy per pulse delivered in <10 ps. The capabilities of the x-ray source were tested by determining the survival of V79-4 hamster cells irradiated with picosecond pulses of ultrasoft x-rays under aerobic and anaerobic conditions, which were found to be consistent with previously published non pulsed data with x-rays of similar energy. These results support the expectation that the disappearance of an oxygen effect for high-LET radiation particles is due to their spatial properties rather than the very short timescale of each particle traversal. For other effects, particularly non-targeted phenomena such as induced genomic instability, expectations may be less clear cut.


Asunto(s)
Transferencia de Energía , Animales , Línea Celular , Cricetinae , Relación Dosis-Respuesta en la Radiación , Rayos Láser , Oxígeno/metabolismo , Radiometría , Factores de Tiempo , Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...