Bone Joint J ; 100-B(12): 1579-1584, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30499327

RESUMEN

AIMS: The introduction of a novel design of total knee arthroplasty (TKA) must achieve outcomes at least as good as existing designs. A novel design of TKA with a reducing radius of the femoral component and a modified cam-post articulation has been released and requires assessment of the fixation to bone. Radiostereometric analysis (RSA) of the components within the first two postoperative years has been shown to be predictive of medium- to long-term fixation. The aim of this study was to assess the stability of the tibial component of this system during this period of time using RSA. PATIENTS AND METHODS: A cohort of 30 patients underwent primary, cemented TKA using the novel posterior stabilized fixed-bearing (ATTUNE) design. There was an even distribution of men and women (15:15). The mean age of the patients was 64 years (sd 8) at the time of surgery; their mean body mass index (BMI) was 35.4 kg/m 2 (sd 7.9). RSA was used to assess the stability of the tibial component at 6, 12, and 24 months compared with a six-week baseline examination. Patient-reported outcome measures were also assessed. RESULTS: The mean maximum total point motion (MTPM) of the tibial component between 12 and 24 months postoperatively was 0.08 mm (sd 0.08), which is well below the published threshold of 0.2 mm (p < 0.001). Patient-reported outcome measures consistently improved. CONCLUSION: The tibial component of this novel design of TKA showed stability between assessment 12 and 24 months postoperatively, suggesting an acceptably low risk of medium- to long-term failure due to aseptic loosening.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Cementos para Huesos , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla , Análisis Radioestereométrico/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/cirugía , Periodo Posoperatorio , Diseño de Prótesis , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
2.
Knee ; 20(6): 388-96, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23583666

RESUMEN

BACKGROUND: The surface characteristics of the femoral component affect polyethylene wear in modular total knee replacements. In the present retrieval study, the surface characteristics of cobalt-chromium (CoCr) alloy and oxidized zirconium (OxZr) femoral components were assessed and compared. METHODS: Twenty-six retrieved CoCr alloy femoral components were matched with twenty-six retrieved OxZr femoral components for implantation period, body-mass index, patient gender, implant type, and polyethylene insert thickness. The surface damage on the retrieved femoral components was evaluated using a semi-quantitative assessment method, scanning electron microscopy, and contact profilometry. RESULTS: The retrieved CoCr alloy femoral components showed less posterior surface gouging than OxZr femoral components; however, at a higher magnification, the grooving damage features on the retrieved CoCr alloy femoral components confirmed an abrasive wear mechanism. The surface roughness values Rp, Rpm, and Rpk for the retrieved CoCr alloy femoral components were found to be significantly higher than those of the retrieved OxZr femoral components (p≤0.031). The surface roughness values were higher on the medial condyles than on the lateral condyles of the retrieved CoCr alloy femoral components; such a difference was not observed on the retrieved OxZr femoral components. CONCLUSIONS: The surface roughness of CoCr alloy femoral components increased while the surface roughness of the OxZr femoral components remained unchanged after in vivo service. Therefore, the OxZr femoral components' resistance to abrasive wear may enable lower polyethylene wear and ensure long-term durability in vivo. LEVEL OF EVIDENCE: Level IV.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Aleaciones de Cromo , Prótesis de la Rodilla , Diseño de Prótesis , Anciano , Artroplastia de Reemplazo de Rodilla/efectos adversos , Fuerza Compresiva , Bases de Datos Factuales , Femenino , Fémur , Estudios de Seguimiento , Humanos , Masculino , Ensayo de Materiales/métodos , Persona de Mediana Edad , Falla de Prótesis , Recuperación de la Función , Estudios Retrospectivos , Medición de Riesgo , Resultado del Tratamiento , Circonio
3.
Bone Joint J ; 95-B(1): 31-7, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23307670

RESUMEN

Symptomatic cobalt toxicity from a failed total hip replacement is a rare but devastating complication. It has been reported following revision of fractured ceramic components, as well as in patients with failed metal-on-metal articulations. Potential clinical findings include fatigue, weakness, hypothyroidism, cardiomyopathy, polycythaemia, visual and hearing impairment, cognitive dysfunction, and neuropathy. We report a case of an otherwise healthy 46-year-old patient, who developed progressively worsening symptoms of cobalt toxicity beginning approximately six months following synovectomy and revision of a fractured ceramic-on-ceramic total hip replacement to a metal-on-polyethylene bearing. The whole blood cobalt levels peaked at 6521 µg/l. The patient died from cobalt-induced cardiomyopathy. Implant retrieval analysis confirmed a loss of 28.3 g mass of the cobalt-chromium femoral head as a result of severe abrasive wear by ceramic particles embedded in the revision polyethylene liner. Autopsy findings were consistent with heavy metal-induced cardiomyopathy.We recommend using new ceramics at revision to minimise the risk of wear-related cobalt toxicity following breakage of ceramic components.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Cardiomiopatías/inducido químicamente , Cobalto/envenenamiento , Prótesis de Cadera/efectos adversos , Complicaciones Posoperatorias/inducido químicamente , Falla de Prótesis/efectos adversos , Cardiomiopatías/diagnóstico , Resultado Fatal , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico , Reoperación
4.
J Hand Ther ; 12(1): 7-15, 1999.
Artículo en Inglés | MEDLINE | ID: mdl-10192630

RESUMEN

The NK computerized hand evaluation system includes a dexterity board that can be used to measure patients' ability to manipulate small, medium, and large objects. This study evaluated the test-retest reliability of the NK dexterity test. Thirty-seven healthy subjects aged 20 to 54 years completed two occasions of dexterity testing. Each occasion included bilateral dexterity tests consisting of two trials of each of three subtests. Intraoccasion intraclass correlation coefficients (ICCs) indicated fair to excellent reliability (ICC, 0.53-0.86). Interoccasion ICCs tended to be lower and ranged from 0.39 to 0.83, depending on the subtest. Reliability tended to be higher with the dominant hand than with the nondominant hand. Improvements in equipment design and alternative testing protocols may be needed to ensure consistently excellent reliability in dexterity scores with this test.


Asunto(s)
Mano/fisiología , Destreza Motora , Adolescente , Adulto , Anciano , Diseño de Equipo , Femenino , Humanos , Masculino , Ensayo de Materiales , Persona de Mediana Edad , Reproducibilidad de los Resultados