Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Front Mol Neurosci ; 17: 1379743, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38756707

RESUMEN

Hearing loss constitutes a major global health concern impacting approximately 1.5 billion people worldwide. Its incidence is undergoing a substantial surge with some projecting that by 2050, a quarter of the global population will experience varying degrees of hearing deficiency. Environmental factors such as aging, exposure to loud noise, and the intake of ototoxic medications are implicated in the onset of acquired hearing loss. Ototoxicity resulting in inner ear damage is a leading cause of acquired hearing loss worldwide. This could be minimized or avoided by early testing of hearing functions in the preclinical phase of drug development. While the assessment of ototoxicity is well defined for drug candidates in the hearing field - required for drugs that are administered by the otic route and expected to reach the middle or inner ear during clinical use - ototoxicity testing is not required for all other therapeutic areas. Unfortunately, this has resulted in more than 200 ototoxic marketed medications. The aim of this publication is to raise awareness of drug-induced ototoxicity and to formulate some recommendations based on available guidelines and own experience. Ototoxicity testing programs should be adapted to the type of therapy, its indication (targeting the ear or part of other medications classes being potentially ototoxic), and the number of assets to test. For multiple molecules and/or multiple doses, screening options are available: in vitro (otic cell assays), ex vivo (cochlear explant), and in vivo (in zebrafish). In assessing the ototoxicity of a candidate drug, it is good practice to compare its ototoxicity to that of a well-known control drug of a similar class. Screening assays provide a streamlined and rapid method to know whether a drug is generally safe for inner ear structures. Mammalian animal models provide a more detailed characterization of drug ototoxicity, with a possibility to localize and quantify the damage using functional, behavioral, and morphological read-outs. Complementary histological measures are routinely conducted notably to quantify hair cells loss with cochleogram. Ototoxicity studies can be performed in rodents (mice, rats), guinea pigs and large species. However, in undertaking, or at the very least attempting, all preclinical investigations within the same species, is crucial. This encompasses starting with pharmacokinetics and pharmacology efficacy studies and extending through to toxicity studies. In life read-outs include Auditory Brainstem Response (ABR) and Distortion Product OtoAcoustic Emissions (DPOAE) measurements that assess the activity and integrity of sensory cells and the auditory nerve, reflecting sensorineural hearing loss. Accurate, reproducible, and high throughput ABR measures are fundamental to the quality and success of these preclinical trials. As in humans, in vivo otoscopic evaluations are routinely carried out to observe the tympanic membrane and auditory canal. This is often done to detect signs of inflammation. The cochlea is a tonotopic structure. Hair cell responsiveness is position and frequency dependent, with hair cells located close to the cochlea apex transducing low frequencies and those at the base transducing high frequencies. The cochleogram aims to quantify hair cells all along the cochlea and consequently determine hair cell loss related to specific frequencies. This measure is then correlated with the ABR & DPOAE results. Ototoxicity assessments evaluate the impact of drug candidates on the auditory and vestibular systems, de-risk hearing loss and balance disorders, define a safe dose, and optimize therapeutic benefits. These types of studies can be initiated during early development of a therapeutic solution, with ABR and otoscopic evaluations. Depending on the mechanism of action of the compound, studies can include DPOAE and cochleogram. Later in the development, a GLP (Good Laboratory Practice) ototoxicity study may be required based on otic related route of administration, target, or known potential otic toxicity.

2.
Bioengineering (Basel) ; 10(12)2023 Nov 29.
Artículo en Inglés | MEDLINE | ID: mdl-38135964

RESUMEN

In the early years of tissue engineering, scientists focused on the generation of healthy-like tissues and organs to replace diseased tissue areas with the aim of filling the gap between organ demands and actual organ donations. Over time, the realization has set in that there is an additional large unmet need for suitable disease models to study their progression and to test and refine different treatment approaches. Increasingly, researchers have turned to tissue engineering to address this need for controllable translational disease models. We review existing and potential uses of tissue-engineered disease models in cardiovascular research and suggest guidelines for generating adequate disease models, aimed both at studying disease progression mechanisms and supporting the development of dedicated drug-delivery therapies. This involves the discussion of different requirements for disease models to test drugs, nanoparticles, and drug-eluting devices. In addition to realistic cellular composition, the different mechanical and structural properties that are needed to simulate pathological reality are addressed.

3.
Ann Biomed Eng ; 51(12): 2908-2922, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37751027

RESUMEN

Drug-Coated Balloons have shown promising results as a minimally invasive approach to treat stenotic arteries, but recent animal studies have revealed limited, non-uniform coating transfer onto the arterial lumen. In vitro data suggested that local coating transfer tracks the local Contact Pressure (CP) between the balloon and the endothelium. Therefore, this work aimed to investigate in silico how different interventional and device parameters may affect the spatial distribution of CP during the inflation of an angioplasty balloon within idealized vessels that resemble healthy femoral arteries in size and compliance. An angioplasty balloon computational model was developed, considering longitudinal non-uniform wall thickness, due to its forming process, and the folding procedure of the balloon. To identify the conditions leading to non-uniform CP, sensitivity finite element analyses were performed comparing different values for balloon working length, longitudinally varying wall thickness, friction coefficient on the balloon-vessel interface, vessel wall stiffness and thickness, and balloon-to-vessel diameter ratio. Findings indicate a significant irregularity of contact between the balloon and the vessel, mainly affected by the balloon's unfolding and longitudinal thickness variation. Mirroring published data on coating transfer distribution in animal studies, the interfacial CP distribution was maximal at the middle of the balloon treatment site, while exhibiting a circumferential pattern of linear peaks as a consequence of the particular balloon-vessel interaction during unfolding. A high ratio of balloon-to-vessel diameter, higher vessel stiffness, and thickness was found to increase significantly the amplitude and spatial distribution of the CP, while a higher friction coefficient at the balloon-to-vessel interface further exacerbated the non-uniformity of CP. Evaluation of balloon design effects revealed that the thicker tapered part caused CP reduction in the areas that interacted with the extremities of the balloon, whereas total length only weakly impacted the CP. Taken together, this study offers a deeper understanding of the factors influencing the irregularity of balloon-tissue contact, a key step toward uniformity in drug-coating transfer and potential clinical effectiveness.


Asunto(s)
Angioplastia de Balón , Paclitaxel , Animales , Angioplastia de Balón/métodos , Arteria Femoral , Materiales Biocompatibles Revestidos , Excipientes
4.
EuroIntervention ; 19(7): 612-620, 2023 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-37501502

RESUMEN

BACKGROUND: Renal denervation is optimised when guided by knowledge of nerve distribution. AIMS: We aimed to assess sympathetic nerve distribution along the renal arteries, especially in post-bifurcation vessel segments. METHODS: Renal arteries and surrounding tissue from 10 body donors were collected and examined histologically. Immunohistochemical staining was used to analyse nerve distribution and to identify afferent and efferent sympathetic nerves. RESULTS: A total of 6,781 nerves surrounding 18 renal arteries were evaluated. The mean lumen-nerve distance of the left renal artery (2.32±1.95 mm) was slightly greater than the right (2.29±2.03 mm; p=0.161); this varied across the arteries' courses: 3.7±2.3 mm in proximal segments, 2.5±2.0 mm in middle segments, 1.9±1.6 mm in distal prebifurcation segments and 1.3±1.0 mm in post-bifurcation segments (p<0.001). The number of nerves per quadrant was highest in the proximal segments (13.7±18.6), followed by the middle (9.7±7.9), distal prebifurcation (8.0±7.6), and distal post-bifurcation (4.3±4.0) segments (p<0.001). Circumferentially, the number of nerves was highest in the superior (7.8±9.4) and the ventral (7.6±13.1) quadrants (p=0.638). The mean tyrosine hydroxylase (TH) to calcitonin gene-related peptide (CGRP) ratio increased from proximal (37.5±33.5) to distal (72.0±7.2 in the post-bifurcation segments; p<0.001). Thirty-eight neuroganglia were identified along 14 (78%) renal arteries. CONCLUSIONS: Nerves converge to the renal arteries' lumen in the distal segments and along branches, resulting in the lowest number of nerves per quadrant and the shortest lumen-nerve distance in the distal post-bifurcation segments. Efferent nerves occur predominantly, and the ratio of efferent to afferent nerves continues to increase in the vessels' course.


Asunto(s)
Simpatectomía , Sistema Nervioso Simpático , Humanos , Simpatectomía/métodos , Riñón , Arteria Renal/inervación
5.
Sci Rep ; 12(1): 1413, 2022 01 26.
Artículo en Inglés | MEDLINE | ID: mdl-35082349

RESUMEN

This study quantified the distribution of nerves and adjacent anatomies surrounding human common hepatic artery (CHA) as guidance for catheter based denervation. CHA collected from cadaveric human donors (n = 20) were histologically evaluated and periarterial dimensions and distributions of nerves, lymph nodes, pancreas and blood vessels quantified by digital morphometry. Nerve abundance decreased significantly with distance from the aortic ostium (P < 0.0001) and was higher in the Superior/Inferior compared to the Anterior/Posterior quadrants (P = 0.014). In each locational group, nerves were absent from the artery wall, and starting 0.5-1.0 mm from the lumen exhibited a first order dependence on radial distance, fully defined by the median distance. Median subject-averaged nerve distance to the lumen was 2.75 mm, ranging from 2.1-3.1 mm in different arterial segments and quadrants and 2.0-3.5 mm in individuals. Inter-individual variance was high, with certain individuals exhibiting 50th and 75th nerve distances of, respectively, 3.5 and 6.5 mm The pancreas rarely approached within 4 mm of the lumen proximally and 2.5 mm more distally. The data indicate that the CHA is a rich and accessible target for sympathetic denervation regardless of sex and diabetes, with efficacy and safety most optimally balanced proximally.


Asunto(s)
Arteria Hepática/inervación , Hígado/inervación , Ganglios Linfáticos/inervación , Páncreas/inervación , Simpatectomía/métodos , Anciano , Autopsia , Vasos Sanguíneos , Ablación por Catéter/métodos , Femenino , Arteria Hepática/anatomía & histología , Humanos , Hígado/anatomía & histología , Hígado/irrigación sanguínea , Circulación Hepática/fisiología , Ganglios Linfáticos/anatomía & histología , Ganglios Linfáticos/irrigación sanguínea , Masculino , Páncreas/anatomía & histología , Páncreas/irrigación sanguínea , Sistema Nervioso Simpático
6.
Biomaterials ; 260: 120337, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32937269

RESUMEN

Paclitaxel coated balloon catheters (PCB) were developed as a polymer-free non-implantable alternative to drug eluting stents, delivering similar drug payloads in a matter of minutes. While PCB have shown efficacy in treating peripheral arterial disease in certain patient groups, restenosis rates remain high and there is no class effect. To help further optimize these devices, we developed a scanning electron microscopy (SEM) imaging technique and computational modeling approach that provide insights into the coating micromorphology dependence of in vivo drug transfer and retention. PCBs coated with amorphous/flaky or microneedle coatings were inflated for 60 sec in porcine femoral arteries. Animals were euthanized at 0.5, 24 and 72 h and treated arteries processed for SEM to image endoluminal coating distribution followed by paclitaxel quantification by mass spectrometry (MS). Endoluminal surfaces exhibited sparse coating patches at 0.5 h, predominantly protruding (13.71 vs 0.59%, P < 0.001), with similar micro-morphologies to nominal PCB surfaces. Microneedle coating covered a 1.5-fold endoluminal area (16.1 vs 10.7%, P = 0.0035) owing to higher proximal and distal delivery, and achieved 1.5-fold tissue concentrations by MS (1933 vs 1298 µg/g, P = 0.1745) compared to amorphous/flaky coating. Acute longitudinal coating distribution tracked computationally predicted microindentation pressure gradients (r = 0.9, P < 0.001), with superior transfer of the microneedle coatings attributed to their amplification of angioplasty contact pressures. By 24 h, paclitaxel concentration and coated tissue areas both declined by >93% even as nonprotruding coating levels were stable between 0.5 and 72 h, and 2.7-fold higher for microneedle vs flaky coating (0.64 vs 0.24%, P = 0.0195). Tissue retained paclitaxel concentrations at 24-72 h trended 1.7-fold higher post treatment with microneedle coating compared to the amorphous/flaky coating (69.9 vs 39.9 µg/g, P = 0.066). Thus, balloon based drug delivery is critically dependent on coating micromorphologies, with superior performance exhibited by micromorphologies that amplify angioplasty pressures.


Asunto(s)
Stents Liberadores de Fármacos , Paclitaxel , Angioplastia , Animales , Materiales Biocompatibles Revestidos , Excipientes , Arteria Femoral , Humanos , Porcinos , Resultado del Tratamiento
7.
Circulation ; 141(23): 1859-1869, 2020 06 09.
Artículo en Inglés | MEDLINE | ID: mdl-32370548

RESUMEN

BACKGROUND: Paclitaxel-containing devices (PTXDs) significantly reduce reintervention in patients with symptomatic femoropopliteal peripheral artery disease. A recent aggregate-data meta-analysis reported increased late mortality in patients with peripheral artery disease treated with PTXDs. We performed an individual patient data meta-analysis to evaluate mortality. METHODS: Manufacturers of US Food and Drug Administration-approved and commercially available devices in the United States provided deidentified individual patient data for independent analysis. Cox proportional hazards 1-stage meta-analysis models using intention-to-treat methods were used for the primary analysis. A secondary analysis of recovered missing vital status data was performed. The impact of control crossover to PTXDs, cause-specific mortality, and drug dose mortality were assessed. RESULTS: A total of 2185 subjects and 386 deaths from 8 PTXD trials with 4-year median follow-up were identified. The primary analysis indicated a 38% (95% CI, 6% to 80%) increased relative mortality risk, corresponding to 4.6% absolute increase, at 5 years associated with PTXD use. Control and treatment arm loss to follow-up and withdrawal were 24% and 23%, respectively. With inclusion of recovered vital status data, the excess relative mortality risk was 27% (95% CI, 3%-58%). This observation was consistent across various scenarios, including as-treated analyses, with no evidence of increased risk over time with PTXDs. Mortality risk tended to be increased for all major causes of death. There were no subgroup differences. No drug dose-mortality association was identified. CONCLUSIONS: This individual patient data meta-analysis, based on the most complete available data set of mortality events from PTXD randomized controlled trials, identified an absolute 4.6% increased mortality risk associated with PTXD use.


Asunto(s)
Angioplastia de Balón/mortalidad , Análisis de Datos , Stents Liberadores de Fármacos , Paclitaxel/administración & dosificación , Enfermedad Arterial Periférica/mortalidad , Enfermedad Arterial Periférica/terapia , Angioplastia de Balón/tendencias , Stents Liberadores de Fármacos/tendencias , Humanos , Mortalidad/tendencias , Ensayos Clínicos Controlados Aleatorios como Asunto/métodos
8.
Biomed Instrum Technol ; 54(1): 37-43, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31961742

RESUMEN

Hydrophilic polymer coatings on intravascular devices lower friction between the device and vasculature, thereby reducing trauma during interventional procedures. Polymer coating embolism-the detachment and downstream embolism of polymer particles-has been reported as an iatrogenic complication of coated interventional devices affecting the vasculature and various organs. The Food and Drug Administration (FDA) acknowledges this complication and continues to work with stakeholders to close gaps in performance testing and standards related to polymer coating integrity. Recent innovations within interventional technologies have led to development of new hydrophilic-coated devices with expanded indications for use. The 2018 FDA draft guidance for intravascular guidewires expands the application of particulate generation testing to most devices and recommends labeling changes to increase industry awareness. This article highlights current procedural trends where the phenomenon of polymer coating embolism may be more prevalent. It describes the mechanisms of polymer separation, reported clinical sequelae, and risk factors for relevant indications. These procedural trends and associated risk factors articulate the need for particulate testing and support the FDA's draft guidance recommendations for performance testing of applied coatings. If standardized, particulate assessments may allow characterization and comparisons of coating integrity among devices from various manufacturers, and are an important foundation for setting particulate limits. As hydrophilic coatings enable endovascular treatment for a range of patient populations, setting particulate limits or finding alternative solutions without compromise to device function may be essential. Particulate testing is relevant to physicians, regulators, and manufacturers for the purposes of product development and quality improvement of interventional devices.


Asunto(s)
Embolia , Materiales Biocompatibles Revestidos , Humanos , Interacciones Hidrofóbicas e Hidrofílicas , Polímeros , Estados Unidos , United States Food and Drug Administration
9.
Transl Res ; 213: 100-111, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31415732

RESUMEN

This study sought to evaluate perisplenic artery nerve distribution and the feasibility of splenic artery denervation (SDN). The NEXION radiofrequency catheter was used to perform SDN in healthy and inflammatory arthritis pigs. Splenic artery anatomy, nerve distribution, and splenic norepinephrine (NEPI) levels were evaluated before and after SDN. Perisplenic artery nerves were primarily distributed within 2.5 mm of the arterial lumen and were largely sympathetic on the basis of tyrosine hydroxylase expression. The pancreas, tended to be circumferentially positioned around the proximal splenic artery, typically >2.5 mm from the lumen, ensuring that most of the nerves could be targeted without affecting this sensitive organ. The mid segment of the splenic artery was relatively free of contact with the adjacent pancreas. Splenic NEPI levels and nerve abundance followed a decreasing gradient from the proximal to distal splenic artery. SDN resulted in significant reductions in splenic NEPI levels at day 14 (60.7%, P = 0.024) in naïve pigs and day 45 (100%, P = 0.001) in inflammatory arthritis pigs. There was no significant effect of SDN on joint soft tissue injury or circulating inflammatory markers in the inflammatory arthritis model. The majority of perisplenic arterial nerves are within close proximity of the lumen and are primarily sympathetic efferent fibers. Nerves in the mid-segment may be the preferred SDN target given their proximity to the artery and paucity of periarterial off-target organs. SDN appears safe and effective at reducing splenic NEPI levels.


Asunto(s)
Desnervación , Arteria Esplénica/anatomía & histología , Arteria Esplénica/cirugía , Animales , Artritis/patología , Catéteres , Citocinas/metabolismo , Modelos Animales de Enfermedad , Estudios de Factibilidad , Inflamación/patología , Masculino , Norepinefrina/metabolismo , Porcinos
10.
J Control Release ; 310: 94-102, 2019 09 28.
Artículo en Inglés | MEDLINE | ID: mdl-31430500

RESUMEN

Paclitaxel coated balloons (PCBs) are a promising non-implantable alternative to drug-eluting stents, whereby drug is delivered to the arterial wall in solid form as a semi-continuous solid coating or as micro drug depots. To date, it has been impossible to predict or even infer local tissue dosing levels and persistence, making it difficult to compare in vivo performance of different devices in healthy animals or to extrapolate such data to diseased human arteries. Here we derive and analyze a coupled reaction diffusion model that accounts for coating dissolution and tissue distribution, and predicts the concentration of dissolved drug in the tissue during and post dissolution. Time scale analysis and numerical simulations based on estimated diffusion coefficients in healthy animal and diseased human arteries both imply that dissolution of crystalline paclitaxel coating is mass transfer coefficient-limited, and can therefore be solved for independently of the tissue transport equations. Specifically, coating retention is predicted to follow piecewise linear kinetics, reflecting the differential and faster dissolution of lumenal versus tissue-embedded coating owing to a disparity in convective forces. This prediction is consistent with published data on a range of PCBs and allowed for the estimation of the associated dissolution rate-constants and the maximal soluble drug concentration in the tissue during coating dissolution. Maximal soluble drug concentration in the tissue scales as the product of the solubility and ratio of the dissolution and diffusion rate-constants. Thus, coatings characterized by micromolar solubilities give rise to nanomolar soluble concentrations in healthy animal arteries and ~0.1 micromolar in calcified atherosclerotic arteries owing to slower tissue diffusion. During dissolution, retention in porcine iliofemoral arteries is predicted to be dominated by solid coating, whereas post dissolution it is dominated by receptor-bound drug (3.7 ng receptors/g tissue). Paclitaxel coating dissolution and dosing kinetics can now be modeled based upon accepted principles of surface dissolution and tissue transport to provide insights into the dependence of clinical efficacy on device properties and the interplay of lesion complexity and procedural parameters.


Asunto(s)
Angioplastia de Balón/métodos , Sistemas de Liberación de Medicamentos/métodos , Modelos Biológicos , Paclitaxel/administración & dosificación , Angioplastia de Balón/instrumentación , Animales , Relación Dosis-Respuesta a Droga , Sistemas de Liberación de Medicamentos/instrumentación , Humanos , Cinética , Paclitaxel/química , Paclitaxel/farmacocinética , Solubilidad , Distribución Tisular
11.
Hypertension ; 74(3): 546-554, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31303108

RESUMEN

Radiofrequency renal denervation is under investigation for treatment of hypertension with variable success. We developed preclinical models to examine the dependence of ablation biomarkers on renal denervation treatment parameters and anatomic variables. One hundred twenty-nine porcine renal arteries were denervated with an irrigated radiofrequency catheter with multiple helically arrayed electrodes. Nerve effects and ablation geometries at 7 days were characterized histomorphometrically and correlated with associated renal norepinephrine levels. Norepinephrine exhibited a threshold dependence on the percentage of affected nerves across the range of treatment durations (30-60 s) and power set points (6-20 W). For 15 W/30 s treatments, norepinephrine reduction and percentage of affected nerves tracked with number of electrode treatments, confirming additive effects of helically staggered ablations. Threshold effects were only attained when ≥4 electrodes were powered. Histomorphometry and computational modeling both illustrated that radiofrequency treatments directed at large neighboring veins resulted in subaverage ablation areas and, therefore, contributed suboptimally to efficacy. Account for measured nerve distribution patterns and the annular geometry of the artery revealed that, regardless of treatment variables, total ablation area and circumferential coverage were the prime determinants of renal denervation efficacy, with increased efficacy at smaller diameters.


Asunto(s)
Ablación por Catéter/métodos , Hipertensión/cirugía , Riñón/inervación , Norepinefrina/sangre , Arteria Renal/cirugía , Simpatectomía/métodos , Animales , Biopsia con Aguja , Modelos Animales de Enfermedad , Electrodos , Femenino , Humanos , Hipertensión/fisiopatología , Inmunohistoquímica , Masculino , Distribución Aleatoria , Valores de Referencia , Porcinos , Resultado del Tratamiento
12.
EuroIntervention ; 15(8): 722-730, 2019 Oct 20.
Artículo en Inglés | MEDLINE | ID: mdl-31062694

RESUMEN

AIMS: Pulmonary arterial hypertension is a devastating disease characterised by pulmonary vascular remodelling and right heart failure. Radio-frequency pulmonary artery denervation (PDN) has improved pulmonary haemodynamics in preclinical and early clinical studies; however, denervation depth is limited. High-frequency non-focused ultrasound can deliver energy to the vessel adventitia, sparing the intima and media. We therefore aimed to investigate the feasibility, safety and efficacy of ultrasound PDN. METHODS AND RESULTS: Histological examination demonstrated that innervation of human pulmonary arteries is predominantly sympathetic (71%), with >40% of nerves at a depth of >4 mm. Finite element analysis of ultrasound energy distribution and ex vivo studies demonstrated generation of temperatures >47ºC to a depth of 10 mm. In domestic swine, PDN reduced mean pulmonary artery pressure induced by thromboxane A2 in comparison to sham. No adverse events were observed up to 95 days. Histological examination identified structural and immunohistological changes of nerves in PDN-treated animals, with sparing of the intima and media and reduced tyrosine hydroxylase staining 95 days post procedure, indicating persistent alteration of the structure of sympathetic nerves. CONCLUSIONS: Ultrasound PDN is safe and effective in the preclinical setting, with energy delivery to a depth that would permit targeting sympathetic nerves in humans.


Asunto(s)
Desnervación , Hipertensión Pulmonar/terapia , Arteria Pulmonar/inervación , Simpatectomía , Animales , Gasto Cardíaco , Ablación por Catéter , Insuficiencia Cardíaca , Humanos , Arteria Pulmonar/patología , Arteria Pulmonar/cirugía , Porcinos , Simpatectomía/instrumentación , Simpatectomía/métodos , Sistema Nervioso Simpático
13.
EuroIntervention ; 14(1): 121-128, 2018 05 20.
Artículo en Inglés | MEDLINE | ID: mdl-29633939

RESUMEN

AIMS: With increasing attention to renovascular causes and targets for hypertension there arises a critical need for more detailed knowledge of renal arterial anatomy. However, a standardised nomenclature is lacking. The present study sought to develop a standardised nomenclature for renal anatomy considering the complexity and variation of the renal arterial tree and to assess the applicability of the nomenclature. METHODS AND RESULTS: One thousand hypertensive patients underwent invasive selective renal artery angiography in nine centres. Further, renovasography was performed in 249 healthy swine as a surrogate for normotensive anatomy. Anatomical parameters were assessed by quantitative vascular analysis. Patients' mean blood pressure was 168/90±26/17 mmHg. The right main renal artery was longer than the left (41±15 mm vs. 35±13 mm, p<0.001), but the left had a greater diameter (5.4±1.2 vs. 5.2±1.2 mm, p<0.001). Accessory renal arteries and renal artery disease were documented in 22% and 9% of the patients, respectively. Other than exhibiting a longer left main renal artery in uncontrolled hypertensives (+2.7 mm, p=0.034) there was no anatomical difference between patients with controlled and uncontrolled hypertension. Main renal artery mean diameter was smaller in patients with impaired kidney function (GFR <90 ml/min, left -0.5 mm, right -0.4 mm, both p<0.001). CONCLUSIONS: Renal arterial anatomy differs between sides but shows no difference between patients with and without blood pressure control. Impaired GFR was associated with small main renal artery diameter.


Asunto(s)
Presión Sanguínea/fisiología , Hipertensión/patología , Riñón/irrigación sanguínea , Arteria Renal/anatomía & histología , Adulto , Anciano , Anciano de 80 o más Años , Animales , Presión Arterial/fisiología , Determinación de la Presión Sanguínea/métodos , Femenino , Humanos , Hipertensión/fisiopatología , Masculino , Persona de Mediana Edad , Arteria Renal/fisiopatología , Porcinos
14.
Cardiovasc Revasc Med ; 19(7 Pt B): 845-851, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29555535

RESUMEN

BACKGROUND/PURPOSE: Catheter-based renal sympathetic denervation (RDN) has been introduced to lower blood pressure (BP) and sympathetic activity in patients with uncontrolled hypertension with at best equivocal results. It has been postulated that anatomic and procedural elements introduce unaccounted variability and yet little is known of the impact of renal anatomy and procedural parameters on BP response to RDN. METHODS/MATERIALS: Anatomical parameters such as length and diameter were analyzed by quantitative vascular analysis and the prevalence of accessory renal arteries and renal artery disease were documented in 150 patients with resistant hypertension undergoing bilateral RDN using a mono-electrode radiofrequency catheter (Symplicity Flex, Medtronic). RESULTS: Accessory renal arteries and renal artery disease were present in 56 (37%) and 14 patients (9%), respectively. At 6-months, 24 h-ambulatory BP was reduced by 11/6 mm Hg (p < 0.001 for both). Change of systolic blood pressure (SBP) was not related to the presence of accessory renal arteries (p = 0.543) or renal artery disease (p = 0.598). Patients with at least one main renal artery diameter ≤ 4 mm had a more pronounced reduction of 24 h-ambulatory SBP compared to patients where both arteries were >4 mm (-19 vs. -10 mmHg; p = 0.038). Neither the length of the renal artery nor the number of RF ablations influenced 24 h-ambulatory BP reduction at 6 months. CONCLUSIONS: 24 h-ambulatory BP lowering was most pronounced in patients with smaller renal artery diameter but not related to renal artery length, accessory arteries or renal artery disease. Further, there was no dose-response relationship observed with increasing number of ablations. CONDENSED ABSTRACT: Because little is known of the impact of renal anatomy and procedural parameters on blood pressure (BP) response to renal denervation (RDN), anatomical and procedural data were analyzed in 150 patients undergoing bilateral RDN. BP lowering was most pronounced in patients with smaller renal artery diameter but not related to renal artery length, the presence of renal artery disease or accessory renal arteries. Further, there was no dose-response relationship observed with increasing number of ablations.


Asunto(s)
Presión Sanguínea , Ablación por Catéter , Hipertensión/cirugía , Arteria Renal/inervación , Simpatectomía/métodos , Anciano , Monitoreo Ambulatorio de la Presión Arterial , Ablación por Catéter/efectos adversos , Toma de Decisiones Clínicas , Femenino , Alemania , Humanos , Hipertensión/diagnóstico , Hipertensión/fisiopatología , Masculino , Persona de Mediana Edad , Selección de Paciente , Estudios Prospectivos , Arteria Renal/anomalías , Arteria Renal/diagnóstico por imagen , Simpatectomía/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
15.
J Control Release ; 274: 102-108, 2018 03 28.
Artículo en Inglés | MEDLINE | ID: mdl-29421608

RESUMEN

BACKGROUND: Innovations in drug eluting stent designs make it increasingly important to develop models for differentiating performance through spatial definition of drug, receptor binding and cell state. METHODS: Two designs of sirolimus analog eluting stents were implanted into porcine coronary arteries for 28, 60 or 90 days (n = 9/time point), durable coating (Xience) and deployable absorbable coating (MiStent). Explanted arteries were evaluated for drug content (n = 3/time point) by LC-MS/MS and for drug and target protein (mTOR) distributions by immunofluorescence (IF, n = 6/time point). A computational model was developed to predict drug release and arterial distribution maps. RESULTS: Both stents released the majority of drug load by 28 days, with different tissue retention efficiencies (91.4 ±â€¯4.9% MiStent versus 21.5 ±â€¯1.9% Xience, P < 0.001). Computational modeling of MiStent coating deployment and microcrystal dissolution recapitulated in vivo drug release and net tissue content and predicted that >98.5% of deployed drug remains crystalline through 90 days. Immunofluorescence and computational modeling showed peristrut drug localization for both stents, with similar peaks, but high interstrut levels only at sites of coating deployment from the absorbable coating. Co-localization of mTOR-IF with drug-IF for both devices showed persistent drug effects, though with differential drug-receptor pharmacokinetics. CONCLUSIONS: Immunofluorescence and computational modeling provide insights into drug distribution and binding status that can help differentiate drug delivery technologies. Herein we found that tissue deployment of slow dissolving crystalline drug particles results in temporally and spatially more uniform drug delivery to interstrut zones that might otherwise be under-dosed without excess peristrut drug.


Asunto(s)
Stents Liberadores de Fármacos , Implantes Absorbibles , Animales , Materiales Biocompatibles Revestidos , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/efectos de los fármacos , Sistemas de Liberación de Medicamentos , Liberación de Fármacos , Humanos , Sirolimus/análogos & derivados , Porcinos
17.
J Control Release ; 264: 203-210, 2017 Oct 28.
Artículo en Inglés | MEDLINE | ID: mdl-28867375

RESUMEN

BACKGROUND: Calcific atherosclerosis is a major challenge to intraluminal drug delivery in peripheral artery disease (PAD). OBJECTIVES: We evaluated the effects of orbital atherectomy on intraluminal paclitaxel delivery to human peripheral arteries with substantial calcified plaque. METHODS: Diagnostic angiography and 3-D rotational imaging of five fresh human lower limbs revealed calcification in all main arteries. The proximal or distal segment of each artery was treated using an orbital atherectomy system (OAS) under simulated blood flow and fluoroscopy. Explanted arterial segments underwent either histomorphometric assessment of effect or tracking of 14C-labeled or fluorescent-labeled paclitaxel. Radiolabeled drug quantified bulk delivery and fluorescent label established penetration of drug over finer spatial domain in serial microscopic sections. Results were interpreted using a mathematical model of binding-diffusion mediated arterial drug distribution. RESULTS: Lesion composition affected paclitaxel absorption and distribution in cadaveric human peripheral arteries. Pretreatment imaging calcium scores in control femoropopliteal arterial segments correlated with a log-linear decline in the bulk absorption rate-constant of 14C-labeled, declining 5.5-fold per calcified quadrant (p=0.05, n=7). Compared to controls, OAS-treated femoropopliteal segments exhibited 180µm thinner intima (p<0.001), 45% less plaque calcification, and 2 log orders higher paclitaxel bulk absorption rate-constants. Correspondingly, fluorescent paclitaxel penetrated deeper in OAS-treated femoropopliteal segments compared to controls, due to a 70% increase in diffusivity (p<0.001). CONCLUSIONS: These data illustrate that calcified plaque limited intravascular drug delivery, and controlled OAS treatment of calcific plaques resulted in greater drug permeability and improved adjunct drug delivery to diseased arteries.


Asunto(s)
Antineoplásicos Fitogénicos/farmacocinética , Aterosclerosis/metabolismo , Calcinosis/metabolismo , Paclitaxel/farmacocinética , Enfermedad Arterial Periférica/metabolismo , Placa Aterosclerótica/metabolismo , Aterosclerosis/tratamiento farmacológico , Transporte Biológico , Calcinosis/tratamiento farmacológico , Humanos , Extremidad Inferior/irrigación sanguínea , Enfermedad Arterial Periférica/tratamiento farmacológico , Placa Aterosclerótica/tratamiento farmacológico
18.
EuroIntervention ; 12(17): 2148-2156, 2017 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-27993749

RESUMEN

AIMS: Simple surface modifications can enhance coronary stent performance. Ultra-hydrophilic surface (UHS) treatment of contemporary bare metal stents (BMS) was assessed in vivo to verify whether such stents can provide long-term efficacy comparable to second-generation drug-eluting stents (DES) while promoting healing comparably to BMS. METHODS AND RESULTS: UHS-treated BMS, untreated BMS and corresponding DES were tested for three commercial platforms. A thirty-day and a 90-day porcine coronary model were used to characterise late tissue response. Three-day porcine coronary and seven-day rabbit iliac models were used for early healing assessment. In porcine coronary arteries, hydrophilic treatment reduced intimal hyperplasia relative to the BMS and corresponding DES platforms (1.5-fold to threefold reduction in 30-day angiographic and histological stenosis; p<0.04). Endothelialisation was similar on UHS-treated BMS and untreated BMS, both in swine and rabbit models, and lower on DES. Elevation in thrombotic indices was infrequent (never observed with UHS, rare with BMS, most often with DES), but, when present, correlated with reduced endothelialisation (p<0.01). CONCLUSIONS: Ultra-hydrophilic surface treatment of contemporary stents conferred good healing while moderating neointimal and thrombotic responses. Such surfaces may offer safe alternatives to DES, particularly when rapid healing and short dual antiplatelet therapy (DAPT) are crucial.


Asunto(s)
Interacciones Hidrofóbicas e Hidrofílicas , Intervención Coronaria Percutánea/instrumentación , Stents , Animales , Neointima/prevención & control , Conejos , Porcinos , Trombosis/prevención & control
19.
Cardiovasc Revasc Med ; 17(7): 474-479, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27617388

RESUMEN

BACKGROUND/PURPOSE: Catheter-based renal sympathetic denervation (RDN) can reduce blood pressure (BP) and sympathetic activity in certain patients with uncontrolled hypertension. Less is known about the impact of renal anatomy and procedural parameters on subsequent BP response. METHODS/MATERIALS: A total of 564 patients with resistant hypertension underwent bilateral RDN in 9 centers in Europe and Australia using a mono-electrode radiofrequency catheter (Symplicity Flex, Medtronic). Anatomical criteria such as prevalence of accessory renal arteries (ARA), presence of renal artery disease (RAD), length, and diameter were analyzed blinded to patient's characteristics. RESULTS: ARA was present in 171 patients (30%), and RAD was documented in 71 patients (13%). On average 11±2.7 complete 120-s ablations were performed, equally distributed on both sides. After 6months, BP was reduced by 19/8mmHg (p<0.001 for both). Change of systolic blood pressure (SBP) was not related to the presence of ARA (-18 vs. -20mmHg; p=NS) or RAD (-16 vs. -20mmHg; p=NS). Patients with a bilateral diameter≤4mm had a more pronounced reduction of SBP compared to patients with a unilateral diameter≤4mm or a bilateral diameter>4mm (-29 vs. -26 vs. -17mmHg; p<0.001). Neither the length of the renal artery nor the number of RF ablations influenced BP reduction after 6months. CONCLUSIONS: The diameter of renal arteries correlated with SBP change after RDN at 6-month follow-up. Change of SBP was not related to the lengths of the renal artery, presence of ARA, RAD, or the number of RF ablations delivered by a mono-electrode catheter.


Asunto(s)
Ablación por Catéter , Hipertensión/cirugía , Riñón/irrigación sanguínea , Arteria Renal/anomalías , Arteria Renal/inervación , Simpatectomía/métodos , Malformaciones Vasculares/complicaciones , Anciano , Antihipertensivos/uso terapéutico , Australia , Presión Sanguínea/efectos de los fármacos , Resistencia a Medicamentos , Europa (Continente) , Femenino , Humanos , Hipertensión/complicaciones , Hipertensión/diagnóstico , Hipertensión/fisiopatología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento , Malformaciones Vasculares/diagnóstico por imagen
20.
Biomaterials ; 93: 71-82, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-27082874

RESUMEN

Pancreatic ductal adenocarcinoma (PDAC) is one of the most devastating and painful cancers. It is often highly resistant to therapy owing to inherent chemoresistance and the desmoplastic response that creates a barrier of fibrous tissue preventing transport of chemotherapeutics into the tumor. The growth of the tumor in pancreatic cancer often leads to invasion of other organs and partial or complete biliary obstruction, inducing intense pain for patients and necessitating tumor resection or repeated stenting. Here, we have developed a delivery device to provide enhanced palliative therapy for pancreatic cancer patients by providing high concentrations of chemotherapeutic compounds locally at the tumor site. This treatment could reduce the need for repeated procedures in advanced PDAC patients to debulk the tumor mass or stent the obstructed bile duct. To facilitate clinical translation, we created the device out of currently approved materials and drugs. We engineered an implantable poly(lactic-co-glycolic)-based biodegradable device that is able to linearly release high doses of chemotherapeutic drugs for up to 60 days. We created five patient-derived PDAC cell lines and tested their sensitivity to approved chemotherapeutic compounds. These in vitro experiments showed that paclitaxel was the most effective single agent across all cell lines. We compared the efficacy of systemic and local paclitaxel therapy on the patient-derived cell lines in an orthotopic xenograft model in mice (PDX). In this model, we found up to a 12-fold increase in suppression of tumor growth by local therapy in comparison to systemic administration and reduce retention into off-target organs. Herein, we highlight the efficacy of a local therapeutic approach to overcome PDAC chemoresistance and reduce the need for repeated interventions and biliary obstruction by preventing local tumor growth. Our results underscore the urgent need for an implantable drug-eluting platform to deliver cytotoxic agents directly within the tumor mass as a novel therapeutic strategy for patients with pancreatic cancer.


Asunto(s)
Adenocarcinoma/tratamiento farmacológico , Carcinoma Ductal Pancreático/tratamiento farmacológico , Sistemas de Liberación de Medicamentos , Neoplasias Pancreáticas/tratamiento farmacológico , Adenocarcinoma/patología , Animales , Antineoplásicos/farmacología , Antineoplásicos/uso terapéutico , Carcinoma Ductal Pancreático/patología , Línea Celular Tumoral , Resistencia a Antineoplásicos/efectos de los fármacos , Humanos , Ratones , Paclitaxel/farmacología , Paclitaxel/uso terapéutico , Neoplasias Pancreáticas/patología , Resultado del Tratamiento , Ensayos Antitumor por Modelo de Xenoinjerto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA