Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Heart ; 110(11): 800-807, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38388469

RESUMEN

OBJECTIVES: The association of pulmonary hypertension (PH) with the outcome after mitral transcatheter edge-to-edge repair (M-TEER) focusing on the new ESC/ERS guidelines definition for PH. BACKGROUND: PH is frequently found in patients with mitral regurgitation and is associated with lower survival rates. Recent studies were based on echocardiographic parameters, but results based on invasive haemodynamics differentiating distinct types of PH using the new definition for PH are missing. METHODS: 449 consecutive M-TEER-treated patients from December 2009 to February 2015 were included in this retrospective analysis. All patients were stratified by the distinct types of PH (no PH, precapillary PH, isolated postcapillary PH, combined post-PH and precapillary PH) according to the definitions of the ESC/ERS guidelines for the diagnosis of PH from 2015 (meanPA cut-off <25 mm Hg, pulmonary capillary wedge pressure (PCWP) cut-off ≤15 mm Hg, diastolic pulmonary gradient cut-off ≥7 mm Hg or pulmonary vascular resistance (PVR) >3 WU) and 2022 (meanPA cut-off ≤20 mm Hg, PCWP cut-off ≤15 mm Hg, PVR cut-off ≥3 WU). RESULTS: Patients with any type of PH (2015: meanPA cut-off 25 mm Hg; 2022: meanPA cut-off >20 mm Hg) showed a higher risk of death after M-TEER compared with patients with no PH (2015: HR 1.61 (95% CI 1.25 to 2.07); p<0.001 and 2022: HR 2.09 (95% CI 1.54 to 2.83); p<0.001). Based on the new PH definition, each PH subgroup showed a lower survival after M-TEER compared with patients with no PH. Echocardiographic estimated systolic PAP showed a correlation with invasively measured mean pulmonary artery pressure (mPAP) (r=0.29, p<0.001) and systolic pulmonary arterial pressure (r=0.34,p<0.001). Cox-regression analysis showed higher invasive diastolic, systolic and mean pulmonary pressures were associated with higher all-cause mortality (p<0.001). In addition, invasive measured higher right atrial pressure, lower pulmonary arterial compliance, higher PVR and higher wedge pressure were identified as predictors of all-cause mortality after M-TEER. CONCLUSIONS: The new PH definition discriminates PH groups and mortality better than the old definition. The lower threshold of mPAP of 20mmHg improved prognostication in this cohort of patients.


Asunto(s)
Cateterismo Cardíaco , Hipertensión Pulmonar , Insuficiencia de la Válvula Mitral , Humanos , Hipertensión Pulmonar/fisiopatología , Hipertensión Pulmonar/mortalidad , Hipertensión Pulmonar/diagnóstico , Femenino , Masculino , Estudios Retrospectivos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/complicaciones , Anciano , Cateterismo Cardíaco/métodos , Resultado del Tratamiento , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Válvula Mitral/cirugía , Presión Esfenoidal Pulmonar/fisiología , Persona de Mediana Edad , Factores de Riesgo , Hemodinámica/fisiología
2.
J Am Coll Cardiol ; 77(18): 2263-2273, 2021 05 11.
Artículo en Inglés | MEDLINE | ID: mdl-33958122

RESUMEN

BACKGROUND: Permanent pacemaker implantation (PPI) remains one of the main drawbacks of transcatheter aortic valve replacement (TAVR), but scarce data exist on PPI after valve-in-valve (ViV) TAVR, particularly with the use of newer-generation transcatheter heart valves (THVs). OBJECTIVES: The goal of this study was to determine the incidence, factors associated with, and clinical impact of PPI in a large series of ViV-TAVR procedures. METHODS: Data were obtained from the multicenter VIVID Registry and included the main baseline and procedural characteristics, in-hospital and late (median follow-up: 13 months [interquartile range: 3 to 41 months]) outcomes analyzed according to the need of periprocedural PPI. All THVs except CoreValve, Cribier-Edwards, Sapien, and Sapien XT were considered to be new-generation THVs. RESULTS: A total of 1,987 patients without prior PPI undergoing ViV-TAVR from 2007 to 2020 were included. Of these, 128 patients (6.4%) had PPI after TAVR, with a significant decrease in the incidence of PPI with the use of new-generation THVs (4.7% vs. 7.4%; p = 0.017), mainly related to a reduced PPI rate with the Evolut R/Pro versus CoreValve (3.7% vs. 9.0%; p = 0.002). There were no significant differences in PPI rates between newer-generation balloon- and self-expanding THVs (6.1% vs. 3.9%; p = 0.18). In the multivariable analysis, older age (odds ratio [OR]: 1.05 for each increase of 1 year; 95% confidence interval [CI]: 1.02 to 1.07; p = 0.001), larger THV size (OR: 1.10; 95% CI: 1.01 to 1.20; p = 0.02), and previous right bundle branch block (OR: 2.04; 95% CI: 1.00 to 4.17; p = 0.05) were associated with an increased risk of PPI. There were no differences in 30-day mortality between the PPI (4.7%) and no-PPI (2.7%) groups (p = 0.19), but PPI patients exhibited a trend toward higher mortality risk at follow-up (hazard ratio: 1.39; 95% CI: 1.02 to 1.91; p = 0.04; p = 0.08 after adjusting for age differences between groups). CONCLUSIONS: In a contemporary large series of ViV-TAVR patients, the rate of periprocedural PPI was relatively low, and its incidence decreased with the use of new-generation THV systems. PPI following ViV-TAVR was associated with a trend toward increased mortality at follow-up.


Asunto(s)
Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Implantación de Prótesis , Sistema de Registros
3.
Int J Cardiovasc Imaging ; 37(10): 2947-2955, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34046774

RESUMEN

Iatrogenic mitral stenosis following transcatheter mitral valve repair (TMVR) for relevant mitral regurgitation (MR) is a potential adverse side-effect, known to affect long-term outcome. However, only few determinants of an elevated mean transmitral pressure gradient (TMPG) have been described thus far. We sought to develop an integrative model for the prediction of TMPG following MitraClip (MC) therapy. From 01/2013 to 03/2017, a total of 175 consecutive patients were successfully (MR ≤ 2 + at discharge) treated with a MitraClip implantation at our centre. Of these, a total of 148 patients (54% male, 77.0 ± 6.0 years, 58% with secondary MR) had complete echocardiographic data sets comprising pre- and postinterventional two- and three-dimensional transthoracic (TTE) and transoesophageal (TOE) echocardiograms. Comprehensive studies of predefined parameters were performed. An expert-based prediction model including preprocedural variables (annular ellipticity, mitral valve commissure-to-commissure diameter, preprocedural transmitral pressure gradient and MR aetiology) was set up and validated with a total of 200 bootstrap samples. A nomogram was developed to predict the postprocedural TMPG based on selected echocardiographic variables. Introduction of nomogram-based guiding of MC therapy could help identify patients at risk for postprocedural mitral stenosis, have an influence on preprocedural patient selection and intraprocedural decision making.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Cateterismo Cardíaco/efectos adversos , Ecocardiografía , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Resultado del Tratamiento
4.
Heart Rhythm ; 18(6): 970-976, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33577972

RESUMEN

BACKGROUND: The number of patients requiring lead extraction has been increasing in recent years. Despite significant advances in operator experience and technique, unexpected complications may occur. Prophylactic placement of femoral sheaths allows for immediate endovascular access for emergency procedures and may shorten response time in the event of complications. OBJECTIVE: The purpose of this study was to assess the benefits of routine prophylactic femoral access in patients undergoing transvenous lead extraction (TLE) and to evaluate the methods, frequency, and efficacy of the emergency measures used in those patients. METHODS: We conducted a retrospective analysis of patients who underwent TLE from January 2012 to February 2019. The data were analyzed with regard to procedural complications and deployment of emergency measures via femoral access. RESULTS: Two hundred eighty-five patients (mean age 65.3 ± 15.5 years) were included in the study. Median lead dwell time was 84 months (interquartile range 58-144). Overall complication rate was 4.2% (n = 12), with 1.8% major complications (n = 5). Clinical success rate was 97.2%. Procedure-related mortality was 1.1% (n = 3). Femoral sheaths were actively engaged in 9.1% (n = 26) of cases. Deployment of snares was the most common intervention (n = 10), followed by prophylactic (n = 6) or emergency placement (n = 1) of occlusion balloons, temporary pacing (n = 3), venous angioplasty (n = 3), diagnostic venography (n = 3), and extracorporeal membrane oxygenation (n = 1). We did not observe any femoral vascular complications due to prophylactic sheath placement. CONCLUSION: Routine prophylactic placement of femoral sheaths shortens response time and quickly establishes control in the event of various complications that may occur during TLE procedures.


Asunto(s)
Desfibriladores Implantables , Remoción de Dispositivos/efectos adversos , Marcapaso Artificial , Complicaciones Posoperatorias/prevención & control , Anciano , Femenino , Vena Femoral , Estudios de Seguimiento , Humanos , Masculino , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
5.
EuroIntervention ; 16(17): 1447-1454, 2021 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-33074154

RESUMEN

AIMS: Failure of transcatheter mitral valve repair (fTMVR) therapy has a decisive prognostic influence, and complex retreatment is of higher risk. The aim of this analysis was to evaluate the survival outcome following percutaneous procedures and surgery after unsuccessful TMVR interventions for different aetiologies. METHODS AND RESULTS: Of 824 consecutive patients who had been treated with the MitraClip device at our institution, between September 2009 and May 2019, 63 (7.6%) symptomatic patients with therapy failure and persistent or recurrent mitral regurgitation (MR) underwent reinterventions. An outcome analysis for primary (PMR) and secondary mitral regurgitation (SMR) and subsequent percutaneous versus surgical treatment was carried out. MitraClip reinterventions were performed in 36 patients (57.1%; n=26 SMR, n=10 PMR), while 27 (42.9%; n=13 SMR, n=14 PMR) underwent open heart surgery. Surgical patients with PMR showed lower mortality than patients with SMR (p<0.0001) and ReClip patients with PMR (p=0.073). Atrial fibrillation (HR 2.915, 95% CI: [1.311, 6.480]), prior open heart surgery (2.820 [1.215, 6.544]) and chronic obstructive pulmonary disease (2.506 [1.099, 5.714]) increased the risk of death. The level of post-interventional MR had no relevant impact on survival. CONCLUSIONS: We conclude that, after SMR and failed TMVR, reclipping is an appropriate treatment option for symptomatic patients. For PMR patients, surgery must be favoured over a reclipping procedure. However, patients with atrial fibrillation, prior open heart surgery and chronic obstructive pulmonary disease are at risk of reduced survival after reinterventions.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Cateterismo Cardíaco/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento
6.
Circulation ; 143(2): 104-116, 2021 01 12.
Artículo en Inglés | MEDLINE | ID: mdl-32975133

RESUMEN

BACKGROUND: Mitral valve-in-valve (ViV) and valve-in-ring (ViR) are alternatives to surgical reoperation in patients with recurrent mitral valve failure after previous surgical valve repair or replacement. Our aim was to perform a large-scale analysis examining midterm outcomes after mitral ViV and ViR. METHODS: Patients undergoing mitral ViV and ViR were enrolled in the Valve-in-Valve International Data Registry. Cases were performed between March 2006 and March 2020. Clinical endpoints are reported according to the Mitral Valve Academic Research Consortium (MVARC) definitions. Significant residual mitral stenosis (MS) was defined as mean gradient ≥10 mm Hg and significant residual mitral regurgitation (MR) as ≥ moderate. RESULTS: A total of 1079 patients (857 ViV, 222 ViR; mean age 73.5±12.5 years; 40.8% male) from 90 centers were included. Median STS-PROM score 8.6%; median clinical follow-up 492 days (interquartile range, 76-996); median echocardiographic follow-up for patients that survived 1 year was 772.5 days (interquartile range, 510-1211.75). Four-year Kaplan-Meier survival rate was 62.5% in ViV versus 49.5% for ViR (P<0.001). Mean gradient across the mitral valve postprocedure was 5.7±2.8 mm Hg (≥5 mm Hg; 61.4% of patients). Significant residual MS occurred in 8.2% of the ViV and 12.0% of the ViR patients (P=0.09). Significant residual MR was more common in ViR patients (16.6% versus 3.1%; P<0.001) and was associated with lower survival at 4 years (35.1% versus 61.6%; P=0.02). The rates of Mitral Valve Academic Research Consortium-defined device success were low for both procedures (39.4% total; 32.0% ViR versus 41.3% ViV; P=0.01), mostly related to having postprocedural mean gradient ≥5 mm Hg. Correlates for residual MS were smaller true internal diameter, younger age, and larger body mass index. The only correlate for residual MR was ViR. Significant residual MS (subhazard ratio, 4.67; 95% CI, 1.74-12.56; P=0.002) and significant residual MR (subhazard ratio, 7.88; 95% CI, 2.88-21.53; P<0.001) were both independently associated with repeat mitral valve replacement. CONCLUSIONS: Significant residual MS and/or MR were not infrequent after mitral ViV and ViR procedures and were both associated with a need for repeat valve replacement. Strategies to improve postprocedural hemodynamics in mitral ViV and ViR should be further explored.


Asunto(s)
Enfermedades de las Válvulas Cardíacas/cirugía , Prótesis Valvulares Cardíacas/normas , Válvula Mitral/cirugía , Sistema de Registros , Reoperación/normas , Reemplazo de la Válvula Aórtica Transcatéter/normas , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Prótesis Valvulares Cardíacas/tendencias , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/tendencias , Humanos , Internacionalidad , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Reoperación/tendencias , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/tendencias
7.
Med Phys ; 45(3): 1108-1117, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29369364

RESUMEN

PURPOSE: The identification of a brain tumor imaged with PET or SPECT is usually performed with visual inspection of an expert medical clinician. However an automated diagnostic of such images hasn't been established or applied. In this study, we explored the possibility of establishing an automated statistical analysis for the diagnosis of glioma by means of IPA-SPECT data. METHODS: On the basis of a dataset of 100 patients that have undergone MRI and IPA-SPECT acquisition, in this work, we identify an automated workflow. Three different approaches were explored: I. statistical non-parametric mapping analysis (SnPM), II. statistical non-parametric analysis with an increased number of permutations due to sign-flipping function (PALM) and III. statistical parametric analysis (SPM). The automated methods were compared with the visual inspection. RESULTS: The study proved PALM and SPM approaches to have a high diagnostic power. Compared to the parametric methods, the non-parametric method is the mathematically correct approach for the problem in question. If we take the high resolution structural MRI information into account, the diagnostic power of PALM was not significantly inferior to the visual inspection (P = 0.5150), showing an area under the ROC curve (AUC) smaller only by less than 3%. CONCLUSIONS: The automated diagnostic method based on statistical inference, here applied to diagnose glioma tumors in IPA-SPECT data, seems to be a promising tool that can support the visual investigation in nuclear medicine. Moreover in the foreseeable future, the presented methodology has a big potential in various application like localization of active tumor tissues in surgical resection or stereotactic radiosurgery.


Asunto(s)
Glioma/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Estadística como Asunto , Tomografía Computarizada de Emisión de Fotón Único , Automatización , Humanos
8.
Eur Heart J Case Rep ; 2(2): yty058, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31020137

RESUMEN

INTRODUCTION: Rheumatic mitral stenosis (MS) is the most common rheumatic heart disease that complicates pregnancy. Percutaneous transvenous mitral commissurotomy (PTMC) has become the first-choice treatment, but is routinely performed with fluoroscopic guidance, which bears risks from ionizing radiation for the embryo when performed in pregnant patients. CASE PRESENTATION: A pregnant patient was referred to our department for therapy of severe MS after she suffered from cerebral artery infarction. The patient underwent successful PTMC under exclusive echocardiographic imaging and showed stable results throughout the pregnancy. The patient showed an improvement in functional capacity from dyspnoea New York Heart Association (NYHA) III to I and delivered a healthy child without any complications. DISCUSSION: This case shows that PTMC of MS under exclusive echocardiography guidance without fluoroscopy is feasible and appears to be safe without causing radiation damage to the embryo.

9.
J Am Coll Cardiol ; 70(22): 2752-2763, 2017 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-29191323

RESUMEN

BACKGROUND: Limited data exist about safety and efficacy of transcatheter aortic valve replacement (TAVR) in patients with pure native aortic regurgitation (AR). OBJECTIVES: This study sought to compare the outcomes of TAVR with early- and new-generation devices in symptomatic patients with pure native AR. METHODS: From the pure native AR TAVR multicenter registry, procedural and clinical outcomes were assessed according to VARC-2 criteria and compared between early- and new-generation devices. RESULTS: A total of 331 patients with a mean STS score of 6.7 ± 6.7 underwent TAVR. The early- and new-generation devices were used in 119 patients (36.0%) and 212 patients (64.0%), respectively. STS score tended to be lower in the new-generation device group (6.2 ± 6.7 vs. 7.6 ± 6.7; p = 0.08), but transfemoral access was more frequently used in the early-generation device group (87.4% vs. 60.8%; p < 0.001). Compared with the early-generation devices, the new-generation devices were associated with a significantly higher device success rate (81.1% vs. 61.3%; p < 0.001) due to lower rates of second valve implantation (12.7% vs. 24.4%; p = 0.007) and post-procedural AR ≥ moderate (4.2% vs. 18.8%; p < 0.001). There were no significant differences in major 30-day endpoints between the 2 groups. The cumulative rates of all-cause and cardiovascular death at 1-year follow-up were 24.1% and 15.6%, respectively. The 1-year all-cause mortality rate was significantly higher in the patients with post-procedural AR ≥ moderate compared with those with post-procedural AR ≤ mild (46.1% vs. 21.8%; log-rank p = 0.001). On multivariable analysis, post-procedural AR ≥ moderate was independently associated with 1-year all-cause mortality (hazard ratio: 2.85; 95% confidence interval: 1.52 to 5.35; p = 0.001). CONCLUSIONS: Compared with the early-generation devices, TAVR using the new-generation devices was associated with improved procedural outcomes in treating patients with pure native AR. In patients with pure native AR, significant post-procedural AR was independently associated with increased mortality.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Válvula Aórtica/cirugía , Arteria Femoral/cirugía , Prótesis Valvulares Cardíacas , Complicaciones Posoperatorias , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Aórtica/cirugía , Cateterismo Periférico/métodos , Cateterismo Periférico/estadística & datos numéricos , Femenino , Prótesis Valvulares Cardíacas/efectos adversos , Prótesis Valvulares Cardíacas/normas , Humanos , Cooperación Internacional , Masculino , Mortalidad , Evaluación de Procesos y Resultados en Atención de Salud , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/epidemiología , Diseño de Prótesis/tendencias , Mejoramiento de la Calidad , Sistema de Registros/estadística & datos numéricos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/estadística & datos numéricos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...