Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Ocul Pharmacol Ther ; 38(4): 311-318, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35442770

RESUMEN

Purpose: To assess the intraocular pressure (IOP)-lowering effect of a biodegradable bimatoprost implant following selective laser trabeculoplasty (SLT) in a canine model. Methods: Unilateral SLT was performed in 11 normotensive, treatment-naive beagle dogs. IOP was measured at baseline (pre-SLT) and weekly post-SLT (≤10 weeks). After IOP returned to baseline or at 10 weeks (whichever occurred first), a sustained-release bimatoprost implant was administered bilaterally in the anterior chamber of each animal. IOP was measured weekly for 4 weeks and then every 2 weeks up to week 42. Results: The main outcomes included the IOP change (%) from baseline, calculated in both eyes in the overall population, SLT responder subgroup (defined by peak IOP reduction from baseline ≥3 mmHg or ≥15% for >1 week post-SLT), and SLT nonresponder subgroup (defined by peak IOP reduction from baseline <3 mmHg or <15%). The bimatoprost implant lowered IOP similarly in both the SLT-treated and fellow SLT-naive eyes. Following bimatoprost implant administration, the mean (standard deviation [SD]) peak IOP reduction from baseline was 34.4% (8.5%) in SLT-treated eyes and 35.7% (5.9%) in fellow SLT-naive eyes. The bimatoprost implant lowered IOP comparably (P > 0.17) in eyes that responded to SLT (mean [SD] peak IOP reduction, 34.6% [10.7%]; n = 6) and those that did not (mean [SD] peak IOP reduction, 34.1% [6.1%]; n = 5). Conclusion: The bimatoprost implant effectively lowered IOP in eyes pretreated with SLT, regardless of response to SLT. The current data suggest that eyes previously treated with SLT can still benefit from the intracameral bimatoprost implant.


Asunto(s)
Terapia por Láser , Hipertensión Ocular , Trabeculectomía , Animales , Bimatoprost/farmacología , Bimatoprost/uso terapéutico , Preparaciones de Acción Retardada , Perros , Presión Intraocular , Rayos Láser , Resultado del Tratamiento
3.
Bone Marrow Transplant ; 56(8): 1850-1858, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33686249

RESUMEN

This longitudinal cohort study compared ocular surface indicators in forty allogeneic hematopoietic stem cell transplant (HSCT) subjects with twenty healthy controls at baseline and identified changes in ocular graft-versus-host disease (oGVHD). Outcome measures included: Ocular Surface Disease Index (OSDI), tear osmolarity, Schirmer's test, Oxford corneal staining score, tear break-up time (TBUT), and tear and serum biomarkers (IFN-γ, IL-10, MMP-9, IL-12, IL-13, IL-17α, IL-1ß, IL-2, IL-4, IL-6, IL-8, CXCL10, MCP-1, MIP-1α, RANTES, TNF-α). At baseline the HSCT group had higher median Oxford corneal staining score (1.7 vs. 0.0; P < 0.0001), higher tear TNF-α (20.0 vs. 11.2 pg/mL; P < 0.0001), lower tear RANTES (70.4 vs. 190.2 pg/mL; P < 0.0001), higher serum IL-8 (10.2 vs. 4.5 pg/mL; P = 0.0008), and higher serum TNF-α (8.7 vs. 4.2 pg/mL; P < 0.0001). The incidence of oGVHD was 62% and associated changes included increased Oxford corneal staining score (4.6 vs. 1.8, P = 0.0001), decreased Schirmer's test (3.0 vs. 10.0; P < 0.0001), and decreased TBUT (4.7 vs. 9.0 s; P = 0.0004). Baseline differences in ocular surface indicators suggest a tendency toward ocular dryness in individuals with hematologic disorders preparing for HSCT. Individuals who developed oGVHD showed changes in corneal staining score, Schirmer's test, and TBUT.


Asunto(s)
Síndromes de Ojo Seco , Enfermedad Injerto contra Huésped , Biomarcadores , Síndromes de Ojo Seco/diagnóstico , Síndromes de Ojo Seco/etiología , Enfermedad Injerto contra Huésped/diagnóstico , Enfermedad Injerto contra Huésped/etiología , Humanos , Estudios Longitudinales , Estudios Prospectivos , Lágrimas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...