Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Transplant Proc ; 40(1): 107-10, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18261559

RESUMEN

BACKGROUND: Tissue Doppler echocardiography has been introduced as a useful tool to assess systolic myocardial function. In this study we sought to compare patients with end-stage renal disease (ESRD), with renal transplantations and control subjects with regard to tissue Doppler parameters. METHODS: Thirty recipients with functional grafts of overall mean age 36 +/- 7 years included 24 men. An equal number of patients with ESRD of overall mean age 35 +/- 7 years included 20 men. A third cohort was comprised of 20 age- and gender matched control subjects. Tissue Doppler imaging from the septal and lateral mitral annulus of the left ventricle and free wall of the right ventricle was performed from a 4-chamber view. RESULTS: Mean systolic and diastolic blood pressures were similar among the groups during imaging. Peak systolic velocity (S wave) at the septal annulus was similar in control subjects and recipients. S waves were significantly lower among ESRD patients compared with recipients (10.3 +/- 2.1 vs 12.0 +/- 2.5 cm/s, P = .04, respectively). Isovolumic contraction velocity of the septum and the right ventricular wall were significantly lower in ESRD patients than recipients or controls: 10.2 +/- 2.6 vs 12.5 +/- 2.8 vs 11.4 +/- 1.8 cm/s for septal wall (P = .008) and 13.9 +/- 3.6 vs 17.9 +/- 5.1 vs 16.8 +/- 5.8, for right ventricle (P = .01). CONCLUSION: Systolic indices of tissue Doppler echocardiography in recipients demonstrated similar values as control subjects and increased values compared with ESRD patients. These results suggested improvement in systolic myocardial function following renal transplantation.


Asunto(s)
Ecocardiografía Doppler , Fallo Renal Crónico/diagnóstico por imagen , Fallo Renal Crónico/cirugía , Trasplante de Riñón/fisiología , Adulto , Presión Sanguínea , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Selección de Paciente , Valores de Referencia , Terapia de Reemplazo Renal , Factores de Tiempo
2.
Transplant Proc ; 40(1): 267-70, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18261604

RESUMEN

PURPOSE: Cardiac allograft vasculopathy (CAV) is the most important cause of late mortality among cardiac allograft recipients. Dobutamine stress echocardiography (DSE) is considered a safe and cost-effective method to screen these patients who remain free of angina most of the time. We evaluated DSE results in a series of cardiac allograft recipients. METHODS: The DSE was performed on a yearly basis. From 2004 to 2006, twelve DSEs were performed on 8 patients, including 7 men, and overall mean age of 36 +/- 12 years. Dobutamine infusion begun at 5 microg/kg/min was titrated at 3-minute stages to 10, 20, 40, and 50 microg/kg/min to achieve the target heart rate. In addition, at every stage, we performed a 12-lead EKG, heart rate, and blood pressure recording. The DSE results were compared with coronary angiograms and endomyocardial biopsies. RESULTS: Two patients displayed mildly and 1 patient a severely abnormal DSE test. The severely abnormal DSE test was associated with severe coronary artery stenosis, including inexperiment of the left main coronary artery. The second patient with an abnormal DSE had contour irregularities and distal cut-off of the right coronary artery as well as 2R cellular rejection. The third patient had a normal angiogram and no rejection. None of the patients with normal DSE experienced a cardiac event, coronary lesions, or rejection. CONCLUSION: Use of DSE appears to be a sensitive method to detect CAV in asymptomatic recipients. However, mild wall motion abnormalities can be detected in patients without stenosing coronary lesions. The value of DSE in predicting CAV must be examined in larger series with long-terms of follow-up.


Asunto(s)
Cardiopatías/diagnóstico por imagen , Trasplante de Corazón/fisiología , Complicaciones Posoperatorias/diagnóstico por imagen , Biopsia , Ecocardiografía de Estrés , Estudios de Seguimiento , Trasplante de Corazón/patología , Humanos , Miocardio/patología , Complicaciones Posoperatorias/patología , Factores de Tiempo , Trasplante Homólogo
3.
Transplant Proc ; 38(2): 636-8, 2006 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-16549194

RESUMEN

PURPOSE: Our objective was to determine the most relevant systolic and diastolic echocardiographic parameters to detect left ventricular (LV) dysfunction associated with allograft rejection among heart transplant recipients. PATIENTS AND METHODS: Seven consecutive recipients underwent serial echocardiographic studies with two-dimensional spectral Doppler and tissue Doppler (TD) according to our institutional protocol. Results were compared with clinical status and endomyocardial biopsies (EMB) whenever available. RESULTS: The time since transplantation was 22 to 850 days. Patient no. 2 had a biopsy-proven acute rejection at the 11th week which was associated with decreased TD velocities, ejection fraction (EF), and stroke volume (SV), as well as increased pericardial effusion and posterior wall thickness. Interestingly, changes in TD parameters preceded those in EF and SV. However, similar but less remarkable changes in TD velocities, EF, SV, pericardial effusion, and posterior wall thickness also occurred during other events, such as systemic infection and immediate postoperative hemodynamic compromise despite no rejection. A biopsy performed 7 months later in a patient with a previous rejection episode due to a relatively low EF and SV as well as increasing pericardial effusion with normal TD velocities revealed no rejection. CONCLUSIONS: These data suggest that echocardiographic findings, although not specific for acute rejection, may play a potential role as a screening test to exclude rejection in heart transplant recipients.


Asunto(s)
Electrocardiografía , Rechazo de Injerto/diagnóstico por imagen , Trasplante de Corazón/patología , Adulto , Biopsia , Femenino , Humanos , Masculino , Miocardio/patología , Reproducibilidad de los Resultados , Ultrasonografía Doppler
4.
Am J Cardiol ; 86(6): 649-53, 2000 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-10980217

RESUMEN

Recent data show that blockade of aldosterone receptors by spironoloctone reduces the risk of morbidity and death among patients with severe heart failure. Heart failure secondary to ischemia is characterized by an imbalance of the autonomic nervous system, which can be assessed by analysis of the heart rate variability (HRV). Spironolactone's effects on HRV are not well defined. If spironolactone has beneficial effects on HRV, this would contribute to favorable results. We therefore measured Holter-derived HRV indexes in a group of 126 patients with heart failure, aged 36 to 83 years, with angiographically proved coronary artery disease, on 3 separate occasions. Patients' sodium intake was restricted; therapy with enalapril, furosemide, and digoxin was begun, and 2 weeks after this standard therapy, spironolactone 50 mg/day was added. Evaluations were done at baseline, and the first and 12th months. After spironolactone, the triangular interpolation of the NN histogram (from 233.0 +/- 98 to 291.7 +/- 74 ms and 340.5 +/- 130 ms, p <0.001) and the percentage of differences between successive normal RR intervals differing >50 ms over a 24-hour electrocardiography (from 2.9 +/- 2.4% to 4.3 +/- 5.2% and 3.9 +/- 2.6%, p <0.002) increased significantly. Ejection fraction and functional classes were also improved. These data imply that in patients with heart failure who are taking conventional drugs, the addition of spironolactone induces a favorable sympathovagal balance. These changes, as assessed by the triangular interpolation of the NN histogram and the percentage of differences between successive normal RR intervals differing >50 ms over a 24-hour electrocardiography, and observed at 1 month after therapy, persisted in the long term.


Asunto(s)
Ritmo Circadiano/fisiología , Diuréticos/uso terapéutico , Insuficiencia Cardíaca/fisiopatología , Frecuencia Cardíaca/fisiología , Isquemia Miocárdica/complicaciones , Espironolactona/uso terapéutico , Función Ventricular Izquierda/efectos de los fármacos , Adulto , Anciano , Anciano de 80 o más Años , Ecocardiografía , Electrocardiografía Ambulatoria/efectos de los fármacos , Femenino , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/tratamiento farmacológico , Insuficiencia Cardíaca/etiología , Frecuencia Cardíaca/efectos de los fármacos , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/tratamiento farmacológico , Isquemia Miocárdica/fisiopatología , Estudios Retrospectivos , Sístole/efectos de los fármacos , Sístole/fisiología , Resultado del Tratamiento , Función Ventricular Izquierda/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...