Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Radiat Prot Dosimetry ; 184(3-4): 380-384, 2019 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-31330025

RESUMEN

We measured the depth profiles of soil-soil-solution distribution coefficients (Kd) of native 127I (127I-Kd) and exogenous 125I- (125I-Kd) in soils from a pasture near the spent nuclear fuel reprocessing plant in Rokkasho, Japan, and investigated their relationships to depth profiles of the concentration in soil of 127I and organic C and Kd of organic C (C-Kd). The depth profiles of 125I-Kd and 127I-Kd were similar. The relatively low 127I concentrations and low values of both 127I-Kd and 125I-Kd indicate that some of the I deposited on the soil surface have been transported to depths greater than 10 cm. On the other hand, high 127I-Kd/125I-Kd ratios in the uppermost 10 cm of soil indicate that some of the 127I bound to that soil could not be exchanged with exogenous 125I. Although a previous study has shown a power function relationship between 125I-Kd and C-Kd, our data show that the relationships of both 125I-Kd and 127I-Kd to C-Kd are exponential functions. The reason for these conflicting results is unknown. Nonetheless, our data clearly show Kd values for both 125I- and 127I to be dependent on C-Kd. In addition, the dependence of both 127I-Kd and 125I-Kd on C-Kd suggests that organic material in the soil has a role in the transport of I down the soil profile.


Asunto(s)
Radioisótopos de Yodo/análisis , Monitoreo de Radiación/métodos , Contaminantes Radiactivos del Suelo/análisis , Suelo/química , Japón
3.
Radiat Prot Dosimetry ; 184(3-4): 368-371, 2019 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-31034563

RESUMEN

The behaviour of I in soil depends on its chemical form in soil solution. Stable I (127I) in the soil solution under actual soil conditions was investigated as a natural analogue of long-lived radioiodine (129I). Soil samples were collected at 5-cm depth intervals down to 20 cm from forests and grasslands in Rokkasho, where the Japanese first commercial nuclear fuel reprocessing plant is located, and the soil solution was extracted by centrifugation. Almost half of total I in the soil solution was iodide, and the other half was dissolved organic I (DOI), with iodate under the detection limit. The proportion of DOI in total I at 0-5 cm depth was larger than the proportions at 5-20 cm depth. The concentration of DOI was positively correlated with that of DOC in the soil solution, suggesting that the behaviour of DOI in the surface soil is affected by labile organic matter dynamics.


Asunto(s)
Bosques , Pradera , Radioisótopos de Yodo/análisis , Compuestos Orgánicos/química , Contaminantes Radiactivos del Suelo/análisis , Radioisótopos de Yodo/clasificación
4.
Appl Radiat Isot ; 134: 302-306, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29102161

RESUMEN

Absolute measurement by the 4πß-γ coincidence counting method was conducted by two photomultipliers facing across a plastic scintillator to be focused on ß ray counting efficiency. The detector was held with a through-hole-type NaI(Tl) detector. The results include absolutely determined activity and its uncertainty especially about extrapolation. A comparison between the obtained and known activities showed agreement within their uncertainties.

5.
Appl Radiat Isot ; 134: 32-34, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29089236

RESUMEN

We aimed to develop certified reference materials that could be used for well-type HPGe detector. We chose wheat flour as a sample and evaluated the homogeneity of the sample in well-type container (5ml). Results showed that inhomogeneity was sufficiently small for validation checks of well-type HPGe detector (uhom = 0.44%).

6.
Appl Radiat Isot ; 126: 249-251, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28431893

RESUMEN

In Japan, we conducted proficiency testing of activity measurement by using high-purity germanium detectors for 134Cs and 137Cs in brown rice grains. Among 176 reported results, 86 % (for 134Cs) and 93 % (for 137Cs) of the results satisfied |En| â‰¦ 1. However, 58 reports for 134Cs and 51 reports for 137Cs had some failures in their evaluations of uncertainties. The proficiency testing was effective to improve the ability of uncertainty evaluation.


Asunto(s)
Radioisótopos de Cesio/análisis , Contaminación Radiactiva de Alimentos/análisis , Oryza/química , Radiometría/métodos , Radioisótopos de Cesio/normas , Accidente Nuclear de Fukushima , Germanio , Humanos , Japón , Ensayos de Aptitud de Laboratorios/métodos , Ensayos de Aptitud de Laboratorios/normas , Ensayos de Aptitud de Laboratorios/estadística & datos numéricos , Radiometría/normas , Radiometría/estadística & datos numéricos , Estándares de Referencia , Espectrometría gamma/métodos , Espectrometría gamma/normas , Espectrometría gamma/estadística & datos numéricos , Incertidumbre
7.
Appl Radiat Isot ; 109: 363-368, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26688354

RESUMEN

A simulation technique was developed for the extrapolation technique in 4πß-γ coincidence counting method. Simultaneous emissions of ß and γ rays were calculated using EGS5 code to obtain coincidence counting between both ß and γ channels. The simulated extrapolation curves were compared with experimental data obtained with (134)Cs measurements using a plastic scintillator in the ß channel. The variation of the extrapolation curves with γ-gate configuration was investigated by the simulation technique.

8.
Appl Radiat Isot ; 81: 261-7, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23660084

RESUMEN

We measured 4π and 2π counting efficiencies for internal conversion electrons (ICEs), gross ß-particles and also ß-rays alone with various source conditions regarding absorber and backing foil thickness using e-X coincidence technique. Dominant differences regarding the penetration, attenuation and backscattering properties among ICEs and ß-rays were revealed. Although the abundance of internal conversion electrons of (137)Cs-(137)Ba is only 9.35%, 60% of gross counts may be attributed to ICEs in worse source conditions. This information will be useful for radionuclide metrology and for surface contamination monitoring.


Asunto(s)
Partículas beta , Radioisótopos de Cesio/análisis , Electrones , Monitoreo de Radiación/instrumentación , Ceniza Radiactiva/análisis , Diseño de Equipo , Análisis de Falla de Equipo , Dosis de Radiación , Reproducibilidad de los Resultados , Dispersión de Radiación , Sensibilidad y Especificidad
9.
Appl Radiat Isot ; 81: 162-4, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23608140

RESUMEN

The accident at the Fukushima Daiichi Nuclear Power Plant in March 2011 released radionuclides into the environment. There is concern that (90)Sr will be concentrated in seafood. To measure the activities of (90)Sr in a short time without chemical processes, we have designed a new detector for measuring activity that obtains count rates using 10 layers of proportional counters that are separated by walls that absorb beta particles. Monte Carlo simulations were performed to confirm that its design is appropriate.


Asunto(s)
Partículas beta , Análisis de los Alimentos/instrumentación , Contaminación Radiactiva de Alimentos/análisis , Radioisótopos/análisis , Conteo por Cintilación/instrumentación , Simulación por Computador , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo , Modelos Estadísticos , Método de Montecarlo , Dosis de Radiación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
10.
Appl Radiat Isot ; 70(9): 2184-7, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22464931

RESUMEN

A tritium radioactivity source was measured by triple-to-double coincidence ratio (TDCR) equipment of the National Metrology Institute of Japan (NMIJ), and measured data were fitted using polynomial approximation and the Newton-Raphson method, a technique whereby equations are solved numerically by successive approximations. The method used to obtain the activity minimizes the difference between statistically calculated data and experimental data. In the fitting, since calculated statistical efficiency and TDCR values are discrete, the calculated efficiencies are approximated by quadratic functions around experimental values and the Newton-Raphson method is used for convergence at the minimal difference between experimental data and calculated data. In this way, the activity of tritium was successfully obtained.


Asunto(s)
Algoritmos , Radiometría/métodos , Tritio/análisis , Dosis de Radiación
11.
Appl Radiat Isot ; 70(9): 2031-6, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22429558

RESUMEN

A simple but versatile data acquisition system for software coincidence experiments is described, in which any time stamping and live time controller are not provided. Signals from ß- and γ-channels are fed to separately two fast ADCs (16 bits, 25 MHz clock maximum) via variable delay circuits and pulse-height stretchers, and also to pulse-height discriminators. The discriminating level was set to just above the electronic noise. Two ADCs were controlled with a common clock signal, and triggered simultaneously by the logic OR pulses from both discriminators. Paired digital signals for each sampling were sent to buffer memories connected to main PC with a FIFO (First-In, First-Out) pipe via USB. After data acquisition in list mode, various processing including pulse-height analyses was performed using MS-Excel (version 2007 and later). The usefulness of this system was demonstrated for 4πß(PS)-4πγ coincidence measurements of (60)Co, (134)Cs and (152)Eu. Possibilities of other extended applications will be touched upon.


Asunto(s)
Algoritmos , Almacenamiento y Recuperación de la Información/métodos , Lenguajes de Programación , Radiometría/instrumentación , Procesamiento de Señales Asistido por Computador/instrumentación , Programas Informáticos , Diseño de Equipo , Análisis de Falla de Equipo , Diseño de Software
12.
Appl Opt ; 50(20): 3703-10, 2011 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-21743584

RESUMEN

An etched calcite square-wave retarder is designed, fabricated, and demonstrated as an illuminator for an interlaced polarization computer-generated hologram (PCGH). The calcite square-wave retarder enables alternating columns of orthogonal linear polarizations to illuminate the interlaced PCGH. Together, these components produce a speckled, tangentially polarized PCGH diffraction pattern with a measured ratio of polarization of 84% and a degree of linear polarization of 0.81. An experimental alignment tolerance analysis is also reported.

13.
Opt Lett ; 35(20): 3423-5, 2010 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-20967087

RESUMEN

An interlaced polarization computer-generated hologram (PCGH) is designed to produce specific irradiance and polarization states in the image plane. The PCGH produces a tangentially polarized annular pattern with correlated speckle, which is achieved by a novel application of the diffuser optimization method. Alternating columns of orthogonal linear polarizations illuminate an interlaced PCGH, producing a ratio of polarization of 88% measured on a fabricated sample. The demonstrated technique can be applied to designs for arbitrary irradiance and polarization states in the image plane.

14.
Appl Radiat Isot ; 68(7-8): 1324-9, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20097086

RESUMEN

Technetium-99m is widely used for many diagnostic investigations in nuclear medicine, thus the standardization of this nuclide is important. In classical 4pibeta-gamma coincidence counting of (99m)Tc, the steep slope of the efficiency function and the large extrapolation range may cause a large measurement uncertainty. In order to overcome these difficulties, we apply the 4pibeta+4pigamma sum counting technique for the standardization. Furthermore, we adopt both the 4pibeta-4pigamma coincidence counting method and the 4pibeta+4pigamma sum counting technique for the standardization of its parent nuclide (99)Mo. High efficiencies for both nuclides were easily achieved by the use of our 4pibeta-4pigamma counter. All the results were consistent with the reference value obtained by the conventional method obtained by NMIJ.


Asunto(s)
Molibdeno/normas , Conteo por Cintilación/métodos , Tecnecio/normas , Métodos , Molibdeno/análisis , Radioisótopos/análisis , Radioisótopos/normas , Estándares de Referencia , Tecnecio/análisis
15.
Appl Radiat Isot ; 68(7-8): 1354-7, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20083411

RESUMEN

In order to calibrate PET devices by a sealed point source, we contrived an absolute activity measurement method for the sealed point source using scintillation detector arrays. This new method was verified by EGS5 Monte Carlo simulation.


Asunto(s)
Conteo por Cintilación/métodos , Radioisótopos de Sodio/normas , Método de Montecarlo , Tomografía de Emisión de Positrones/normas , Estándares de Referencia
16.
Ann Oncol ; 20(1): 71-7, 2009 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-18723551

RESUMEN

BACKGROUND: The current study examined the clinical usefulness of YKL-40 in detection and prognosis of uterine cervical cancer. PATIENTS AND METHODS: Serum levels of YKL-40, cancer antigen 125 (CA 125), carbohydrate antigen 19-9 (CA19-9), and squamous cell carcinoma (SCC) antigen were determined by enzyme-linked immunosorbent assay in women with benign gynecologic disease (n=24), cervical malignancy (SCC, n=104; adenocarcinoma, n=37), and age-matched healthy controls (n=45). Immunohistochemical analysis for local YKL-40 expression was carried out on 28 adenocarcinomas. RESULTS: Receiver operating characteristic curve analysis showed that YKL-40 [area under the curve (AUC)=0.882] was significantly better at discriminating adenocarcinoma from healthy control than SCC antigen, CA 125, and CA19-9. For SCC, YKL-40 (AUC=0.898) carried out similarly to SCC antigen and was better than CA 125 and CA19-9. Using a cut-off YKL-40 value of 92.2 ng/ml, sensitivity of YKL-40 in stage I adenocarcinoma (68%) was higher than that of the other three markers (11%-21%). Tumor-associated macrophages showed immunoreactivity for YKL-40 in 2 of 28 adenocarcinoma tissue samples, but adenocarcinoma cells themselves were nonimmunoreactive in all samples. Multivariate Cox regression analysis revealed that elevated pretreatment YKL-40 levels predicted unfavorable prognosis, independent of International Federation of Gynecology and Obstetrics stage and age at diagnosis. CONCLUSIONS: Pretreatment serum YKL-40 level is a possible prognosticator of cervical adenocarcinoma.


Asunto(s)
Adenocarcinoma/diagnóstico , Biomarcadores de Tumor/sangre , Glicoproteínas/sangre , Neoplasias del Cuello Uterino/diagnóstico , Adenocarcinoma/sangre , Adenocarcinoma/metabolismo , Adipoquinas , Adulto , Anciano , Anciano de 80 o más Años , Biomarcadores de Tumor/metabolismo , Carcinoma de Células Escamosas/sangre , Carcinoma de Células Escamosas/diagnóstico , Carcinoma de Células Escamosas/metabolismo , Estudios de Casos y Controles , Proteína 1 Similar a Quitinasa-3 , Femenino , Glicoproteínas/metabolismo , Glicoproteínas/normas , Humanos , Lectinas , Persona de Mediana Edad , Pronóstico , Valores de Referencia , Sensibilidad y Especificidad , Neoplasias del Cuello Uterino/sangre , Neoplasias del Cuello Uterino/metabolismo
17.
Nature ; 452(7185): 332-5, 2008 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-18354478

RESUMEN

Equal amounts of matter and antimatter are predicted to have been produced in the Big Bang, but our observable Universe is clearly matter-dominated. One of the prerequisites for understanding this elimination of antimatter is the nonconservation of charge-parity (CP) symmetry. So far, two types of CP violation have been observed in the neutral K meson (K(0)) and B meson (B(0)) systems: CP violation involving the mixing between K(0) and its antiparticle (and likewise for B(0) and ), and direct CP violation in the decay of each meson. The observed effects for both types of CP violation are substantially larger for the B(0) meson system. However, they are still consistent with the standard model of particle physics, which has a unique source of CP violation that is known to be too small to account for the matter-dominated Universe. Here we report that the direct CP violation in charged B(+/-)-->K(+/-)pi(0) decay is different from that in the neutral B(0) counterpart. The direct CP-violating decay rate asymmetry, (that is, the difference between the number of observed B(-)-->K(-)pi(0) event versus B(+)-->K(+) pi(0) events, normalized to the sum of these events) is measured to be about +7%, with an uncertainty that is reduced by a factor of 1.7 from a previous measurement. However, the asymmetry for versus B(0)-->K(+)pi(-) is at the -10% level. Although it is susceptible to strong interaction effects that need further clarification, this large deviation in direct CP violation between charged and neutral B meson decays could be an indication of new sources of CP violation-which would help to explain the dominance of matter in the Universe.

18.
Radiat Prot Dosimetry ; 129(4): 426-30, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-17998200

RESUMEN

The use of the parallel-plate avalanche counter for slow-neutron counting is described. The choice of a suitable neutron converter is discussed on the basis of Monte Carlo simulation, and some experimental results are shown. Excellent gamma-insensitivity, high rate capability, possibility of construction in large sensitive area and low production cost are among the promising features of this neutron detector.


Asunto(s)
Rayos gamma , Método de Montecarlo , Análisis de Activación de Neutrones/instrumentación , Análisis de Activación de Neutrones/métodos , Neutrones , Radiometría/instrumentación , Simulación por Computador , Humanos , Modelos Biológicos , Radiometría/métodos
19.
Biochem Soc Trans ; 31(Pt 6): 1438-40, 2003 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-14641083

RESUMEN

Immunological approaches have been used to demonstrate the presence of advanced glycation end-products (AGEs) in several human and experimental animal tissues. We previously prepared polyclonal and monoclonal anti-AGE antibodies by immunizing AGE-modified proteins such as BSA and RNase. Although these antibodies contributed to demonstrate the presence of AGE-modified protein in vivo, the epitope structure of these antibodies had not been identified. We subsequently prepared several antibodies against AGE structures such as pentosidine, pyrraline, 3-deoxyglucosone imidazolone and N epsilon-(carboxyethyl)lysine by immunizing single AGE structures. These structure-specific antibodies have greatly helped broaden our understanding of AGE structures in aging and age-enhanced disease process. Monoclonal anti-AGE antibody is also used for the identification of major AGE structures in some pathological tissues, such as human atherosclerosis lesions. Based on the strategy, we successfully identified a novel AGE structure named glycolaldehyde-pyridine, which is the major antigenic AGE derived from glycolaldehyde. Therefore a monoclonal antibody library for AGE structures has served an important role in the elucidation of the biological significance of AGE.


Asunto(s)
Anticuerpos Monoclonales/inmunología , Productos Finales de Glicación Avanzada/inmunología , Animales , Anticuerpos Monoclonales/química , Ratones , Ratones Endogámicos BALB C
20.
Neurol Med Chir (Tokyo) ; 41(1): 13-7; discussion 17-8, 2001 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-11218634

RESUMEN

Asymptomatic small hemorrhages were identified in hypertensive patients by T2*-weighted gradient echo magnetic resonance (MR) imaging to investigate the relationship between hypertensive intracerebral hemorrhage and asymptomatic minute hemorrhages. Forty-eight patients with hypertensive intracerebral hemorrhage or cerebral infarction with hypertension (these diseases were defined as stroke) were treated in National Defense Medical College from April 1998 to February 2000. All patients had no past history of stroke or head injury, underwent MR imaging within 6 months of the stroke attack, were aged from 40 to 80 years, and had no diagnosis of aneurysm, angioma, or moyamoya disease. Patients were divided into the infarction group and hemorrhage group. All foci over 2 mm in size appearing as hypointense on T2*-weighted MR imaging and unrelated to stroke areas were defined as minute hemorrhages. There were no significant differences between the two groups with respect to sex, age, and history of diabetes mellitus. The incidence of minute hemorrhages in the hemorrhage group (21/26) was greater than in the infarction group (9/22, p < 0.01). The incidence of minute hemorrhages in the basal ganglia (18/26) was greater in the hemorrhage group than in the infarction group (4/22, p < 0.001). Symptomatic intracerebral hemorrhage may be preceded by asymptomatic minute hemorrhage.


Asunto(s)
Infarto Cerebral/diagnóstico , Hemorragia Intracraneal Hipertensiva/diagnóstico , Adulto , Anciano , Hemorragia de los Ganglios Basales/diagnóstico , Encéfalo/patología , Diagnóstico Diferencial , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...