Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros










Intervalo de año de publicación
1.
Lab Anim ; 56(4): 331-343, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35072576

RESUMEN

Denture stomatitis is the most prevalent form of oral candidiasis and the most frequent oral lesion in removable prosthesis wearers. It is characterized by an inflammatory response of the denture-bearing mucosa, especially the palatal mucosa, and its clinical signs include chronic edema and erythema, and papillary hyperplasia. Despite having a multifactorial etiology, its main etiological agent is the infection by Candida albicans. Given its high treatment failure rates, an in vivo model of denture stomatitis should be established to test alternative treatments. The aim of this study is to review the existing denture stomatitis models and to provide an overview of the main methodological differences between them. Over the last 40 years, different animal models were developed in order to study denture stomatitis etiopathogenesis and to assess novel therapies. Many approaches, including the use of antibiotics and immunosuppressors, have to be further investigated in order to establish which protocol is more appropriate and effective for the development of an animal model of denture stomatitis.


Asunto(s)
Candidiasis Bucal , Estomatitis Subprotética , Animales , Candida albicans , Candidiasis Bucal/complicaciones , Candidiasis Bucal/patología , Modelos Animales de Enfermedad , Mucosa Bucal/patología , Estomatitis Subprotética/etiología , Estomatitis Subprotética/patología , Estomatitis Subprotética/terapia
2.
J Med Microbiol ; 70(10)2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34623230

RESUMEN

Introduction. Candida albicans can produce a complex, dynamic and resistant biofilm on the surface of dental materials, especially denture base acrylic resins and temporary soft liners. This biofilm is the main aetiological factor for denture stomatitis, an oral inflammatory condition characterized by chronic and diffuse erythema and oedema of the denture bearing mucosa.Gap Statement. There is no consensus in the literature regarding the best method to detach biofilms from dental materials. In order to assess the antifungal efficacy of new materials and treatments, the biofilm needs to be properly detached and quantified.Aim. This study compared different methods of detaching C. albicans biofilm from denture base acrylic resin (Vipi Cril) and temporary soft liner (Softone) specimens.Methodology. Specimens of each material were immersed in an inoculum of C. albicans SC5314 and remained for 90 min in orbital agitation at 75 r.p.m. and 37 °C. After the removal of non-adherent cells, the specimens were immersed in RPMI-1640 medium for 48 h. Biofilm formation was evaluated with confocal laser scanning microscopy (n=5). Then, other specimens (n=7) were fabricated, contaminated and immersed in 3 ml of sterile phosphate-buffered saline (PBS) and vortexed or sonicated for 1, 2, 5, or 10 min to detach the biofilm. The quantification of detached biofilm was performed by colony-forming unit (c.f.u.) ml-1 count. Results were submitted to one-way analysis of variance (ANOVA)/Tukey HSD test (α=0.05).Results. A mature and viable biofilm was observed on the surfaces of both materials. For both materials, there was no significant difference (P>0.05) among detachment methods.Conclusion. Any of the tested methods could be used to detach C. albicans biofilm from hard and soft acrylic materials.


Asunto(s)
Biopelículas/crecimiento & desarrollo , Candida albicans/fisiología , Descontaminación/métodos , Materiales Dentales , Resinas Acrílicas/farmacología , Antifúngicos/farmacología , Biopelículas/efectos de los fármacos , Candida albicans/efectos de los fármacos , Recuento de Colonia Microbiana , Materiales Dentales/farmacología , Dentaduras/microbiología , Humanos , Ácidos Polimetacrílicos/farmacología
3.
J Prosthet Dent ; 123(1): 173-180, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31027950

RESUMEN

STATEMENT OF PROBLEM: No information is available on roughness and stainability of acrylic resins polymerized by experimental microwave cycles after immersion in stainable liquids and simulated brushing. PURPOSE: The purpose of this in vitro study was to evaluate the effect of stainable drinks and brushing on roughness and stainability of acrylic resins (Vipi Cril [CA] and Vipi Wave [MA]) polymerized with different cycles. MATERIAL AND METHODS: CA and MA specimens (n=5; diameter, 20 mm; thickness, 3 mm) were made using 4 methods recommended by the manufacturer (water bath polymerization and microwave polymerization cycles) and experimental at 550 W or 650 W for 3 or 5 minutes (M550/3 and M650/5), respectively. After storage in distilled water at 37°C for 48 hours (T0), the specimens were stored in water, coffee, or red wine (37°C) for 36 days with simulated brushing (54 000 cycles, T1). Roughness (Ra) and stainability (ΔE/National Bureau of Standards) were measured at T0 and T1. Roughness and stainability data were analyzed by 3-way repeated measures and 2-way ANOVA, respectively, followed by the Bonferroni test (α=.05). RESULTS: After storing in coffee and brushing, CA showed the highest (M550/3=2.33 ±0.72 µm) and the lowest roughness (water bath polymerization=1.22 ±0.58 µm), whereas roughness of MA specimens processed by M650/5 increased (1.57 ±0.59 µm). Storing in wine and brushing increased roughness (1.75 ±0.32 µm) in the M550/3 group. No staining was observed on MA after brushing regardless of the polymerization cycle. All values were acceptable (ΔE≤3.3), except for MA (microwave polymerization), which showed National Bureau of Standards=4.49 (appreciable change) after storing in wine and brushing. CONCLUSIONS: A slight increase in material roughness was observed after staining and brushing. Only MA polymerized following manufacturer cycles showed relevant stainability after immersion in wine and brushing.


Asunto(s)
Resinas Acrílicas , Cepillado Dental , Ensayo de Materiales , Microondas , Polimerizacion , Propiedades de Superficie
4.
Indian J Dent Res ; 30(6): 927-932, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31939373

RESUMEN

BACKGROUND: Microwave polymerization reduces the time of acrylic resin processing, but it is important to select a proper cycle to avoid overheating, porosity, and impairment to the materials' properties. AIMS: To evaluate the microhardness of conventional (Vipi Cril-VC) and microwaved (Vipi Wave-VW) acrylic resins after microwave polymerization cycles and the cycles recommended by the manufacturer. It was also evaluated the effect of thermocycling on the microhardness of these materials. METHODS AND MATERIALS: Specimens (n = 10) were made: 1. WB (water-bath recommended for VC polymerization); 2. M630/25 (10 min at 270 W; 5 min at 0 W; 10 min at 360 W: recommended for VW polymerization); 3. M550/3 (3 min at 550 W); and 4. M650/5 (5 min at 650 W). After 48 h in distilled water at 37°C, specimens were subjected to Knoop test under 25 g during 5 s. The same specimens were submitted to thermocycling (5,000 cycles; 5°C and 55°C; 60 s) and the microhardness was again measured. The results were analyzed by repeated measures one-way analysis of variance/Bonferroni for each material (α = 0.05). RESULTS: For both materials, no difference was obtained for groups polymerized using the cycles recommended by the manufacturer (VC = 19.8 ± 0.9 KHN; VW = 21.0 ± 1.6 KHN) and M650/5 (VC = 19.9 ± 1.5 KHN; VW = 20.9 ± 0.8 KHN). After thermocycling, microhardness decreased in experimental cycles for VC (M550/3 = 17.0 ± 1.9 to 14.6 ± 1.2 KHN; M650/5 = 19.9 ± 1.5 to 17.8 ± 0.8 KHN) and in all microwave cycles for VW (M630/25 = 21.0 ± 1.6 to 18.3 ± 0.9 KHN; M550/3 = 17.5 ± 3.0 to 15.7 ± 2.0 KHN; M650/5 = 20.9 ± 0.8 to 18.2 ± 2.0 KHN) (P = 0.000). The lowest hardness was observed for both resins processed by M550/3 (P = 0.001). CONCLUSIONS: Both materials could be polymerized in microwave during 5 min showing hardness similar to the cycles recommended by the manufacturer. Thermocycling did not decrease the hardness of VC polymerized with both cycles recommended by the manufacturer and VW polymerized with the water-bath conventional cycle.


Asunto(s)
Bases para Dentadura , Microondas , Resinas Acrílicas , Dureza , Ensayo de Materiales , Polimerizacion
5.
J Prosthet Dent ; 115(5): 611-6, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26794705

RESUMEN

STATEMENT OF PROBLEM: Incorporating antifungals into interim denture resilient liners has been proposed to prolong their clinical longevity and to treat denture stomatitis. However, information is lacking on the effect of this addition on water sorption and solubility. PURPOSE: The purpose of this in vitro study was to evaluate the addition of minimum inhibitory concentrations (MICs) of antifungals for Candida albicans biofilm on the water sorption (WS) and solubility of interim denture resilient liners. MATERIAL AND METHODS: Disk-shaped specimens (n=10; 50×0.5 mm) of tissue conditioner (Softone) and resilient liner (Trusoft) were created either without (control) or with the incorporation of 1 of the 3 following drugs at MICs (g of drug per g of resilient material powder): nystatin (Ny, 0.032g/g), chlorhexidine diacetate (Chx, 0.064g/g), and ketoconazole (Ke, 0.128g/g). Specimens were dried; immersed in water for 24 hours and 7 or 14 days; weighed, dried, and weighed again. Data (µg/mm(3)) were analyzed by 3-way ANOVA followed by the Tukey-Kramer honest significant differences test (α=.05). RESULTS: At the 14-day interval, only the addition of Chx (483.0 ±61.0 µg/mm(3)) increased the WS of the tissue conditioner compared with the control group (244.0 ±42.0 µg/mm(3); P<.001). For all periods, the solubility of both materials increased with the addition of Chx (27.7 ±6.1 µg/mm(3)) and Ke (30.9 ±5.3 µg/mm(3)) compared with the control group (22.5 ±6.0 µg/mm(3); P<.001). CONCLUSIONS: After 14 days, the addition of Ny and Ke at MICs in both Softone and Trusoft and addition of Chx in Trusoft did not affect WS. The solubility of the 2 interim materials was not altered by the addition of Ny for up to 14 days.


Asunto(s)
Antifúngicos/uso terapéutico , Bases para Dentadura , Rebasado de Dentaduras/métodos , Antifúngicos/administración & dosificación , Biopelículas/efectos de los fármacos , Candidiasis Bucal/prevención & control , Humanos , Técnicas In Vitro , Pruebas de Sensibilidad Microbiana , Agua/metabolismo
6.
J Prosthodont ; 25(1): 33-8, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25557469

RESUMEN

PURPOSE: Temporomandibular disorders (TMD) are recognized as one of the most controversial topics in dentistry, despite the fact that both basic science and clinical researchers have currently reached some degree of consensus. This study aimed to conduct a questionnaire-based survey about the management of TMD patients by general dental practitioners (GDPs). MATERIALS AND METHODS: One hundred fifty-one GDPs with a private practice in a city of southern Brazil were included, independent of school of origin, gender, graduation year, and curriculum content. All participants were administered a questionnaire about the management of patients with TMD, and the responses were analyzed by binomial and chi-square tests (α = 0.05). RESULTS: Of the GDPs, 88.7% received TMD patients, who were primarily diagnosed on the basis of medical history (36.6%) or physical examination (30.4%). Of these, 65.4% referred the patients elsewhere, primarily to specialists in occlusion (36.1%) or orthodontics (29.7%). Occlusal splinting was the most commonly used management modality (20.8%), followed by occlusal adjustment (18.1%) and pharmacotherapy (16.6%). Splints were fabricated in maximum habitual intercuspation or centric relation depending on individual patient (54.8%). The hard stabilization form was the most common type of appliance used (35.0%). Moreover, 73.8% of the GDPs did not employ semi-adjustable articulators, and 69.5% adjusted the appliances at the time of fixing. The duration of splint use and the frequency of follow-up were considered patient dependent by 62.1% and 72.8%, respectively. GDPs considered the two major TMD etiologic categories as multifactorial (20.8%) and occlusion (19.9%). Multidisciplinary medical and dental treatment was considered necessary by 97.9%. CONCLUSIONS: The evaluated general dental practitioners manage TMD patients according to international guidelines.


Asunto(s)
Odontología General , Ferulas Oclusales , Trastornos de la Articulación Temporomandibular/terapia , Brasil , Humanos , Encuestas y Cuestionarios , Trastornos de la Articulación Temporomandibular/diagnóstico
7.
J Prosthodont ; 24(3): 207-14, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25082183

RESUMEN

PURPOSE: While the incorporation of antimicrobial agents into soft denture liners has been suggested as a reliable alternative treatment for denture stomatitis, it may affect the liner's properties. The effect of addition of antimicrobial agents for the treatment of denture stomatitis on the surface roughness and Shore A hardness of soft lining materials was evaluated. MATERIALS AND METHODS: The test groups comprised specimens (36 × 7 × 6 mm(3) ) of soft materials (Softone and Trusoft) without (control) or with incorporation of drugs (nystatin, miconazole, ketoconazole, chlorhexidine diacetate, and itraconazole). Hardness (Shore A) and roughness (Ra) were evaluated after immersion of specimens (n = 10) in distilled water at 37°C for 24 hours, 7 and 14 days. Data were analyzed by 3-way ANOVA/Tukey's test (α = 0.05). RESULTS: After 14 days, an increase (p < 0.05) was observed in the hardness of soft materials with time for the modified specimens, except for itraconazole. Addition of drugs increased the Softone roughness only for the addition of miconazole and chlorhexidine (p < 0.05), and did not increase the roughness of Trusoft with time. Only chlorhexidine and itraconazole altered the roughness compared to the control for each material (p < 0.05). CONCLUSIONS: The smallest changes of hardness and roughness with time in the modified groups compared to controls were observed for itraconazole groups for both materials.


Asunto(s)
Antiinfecciosos/química , Alineadores Dentales , Ácidos Polimetacrílicos/química , Clorhexidina/química , Dureza/efectos de los fármacos , Itraconazol/química , Cetoconazol/química , Ensayo de Materiales , Miconazol/química , Nistatina/química , Propiedades de Superficie/efectos de los fármacos
8.
J. appl. oral sci ; 20(6): 607-612, Nov.-Dec. 2012. ilus
Artículo en Inglés | LILACS | ID: lil-660630

RESUMEN

In order to prolong the clinical longevity of resilient denture relining materials and reduce plaque accumulation, incorporation of antimicrobial agents into these materials has been proposed. However, this addition may affect their properties. OBJECTIVE: This study evaluated the effect of the addition of antimicrobial agents into one soft liner (Soft Confort, Dencril) on its peel bond strength to one denture base (QC 20, Dentsply). MATERIAL AND METHODS: Acrylic specimens (n=9) were made (75x10x3 mm) and stored in distilled water at 37ºC for 48 h. The drug powder concentrations (nystatin 500,000U - G2; nystatin 1,000,000U - G3; miconazole 125 mg - G4; miconazole 250 mg - G5; ketoconazole 100 mg - G6; ketoconazole 200 mg - G7; chlorhexidine diacetate 5% - G8; and 10% chlorhexidine diacetate - G9) were blended with the soft liner powder before the addition of the soft liner liquid. A group (G1) without any drug incorporation was used as control. Specimens (n=9) (75x10x6 mm) were plasticized according to the manufacturers' instructions and stored in distilled water at 37ºC for 24 h. Relined specimens were then submitted to a 180-degree peel test at a crosshead speed of 10 mm/min. Data (MPa) were analyzed by analysis of variance (α=0.05) and the failure modes were visually classified. RESULTS: No significant difference was found among experimental groups (p=0.148). Cohesive failure located within the resilient material was predominantly observed in all tested groups. CONCLUSIONS: Peel bond strength between the denture base and the modified soft liner was not affected by the addition of antimicrobial agents.


Asunto(s)
Resinas Acrílicas/química , Antiinfecciosos/química , Bases para Dentadura , Recubrimiento Dental Adhesivo/métodos , Rebasado de Dentaduras/métodos , Clorhexidina/química , Fracaso de la Restauración Dental , Cetoconazol/química , Ensayo de Materiales , Miconazol/química , Nistatina/química , Reproducibilidad de los Resultados , Propiedades de Superficie , Resistencia a la Tracción , Agua/química
9.
J Appl Oral Sci ; 20(6): 607-12, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23329241

RESUMEN

UNLABELLED: In order to prolong the clinical longevity of resilient denture relining materials and reduce plaque accumulation, incorporation of antimicrobial agents into these materials has been proposed. However, this addition may affect their properties. OBJECTIVE: This study evaluated the effect of the addition of antimicrobial agents into one soft liner (Soft Confort, Dencril) on its peel bond strength to one denture base (QC 20, Dentsply). MATERIAL AND METHODS: Acrylic specimens (n=9) were made (75x10x3 mm) and stored in distilled water at 37 ºC for 48 h. The drug powder concentrations (nystatin 500,000 U--G2; nystatin 1,000,000 U--G3; miconazole 125 mg--G4; miconazole 250 mg--G5; ketoconazole 100 mg - G6; ketoconazole 200 mg--G7; chlorhexidine diacetate 5%--G8; and 10% chlorhexidine diacetate--G9) were blended with the soft liner powder before the addition of the soft liner liquid. A group (G1) without any drug incorporation was used as control. Specimens (n=9) (75x10x6 mm) were plasticized according to the manufacturers' instructions and stored in distilled water at 37 ºC for 24 h. Relined specimens were then submitted to a 180-degree peel test at a crosshead speed of 10 mm/min. Data (MPa) were analyzed by analysis of variance (α=0.05) and the failure modes were visually classified. RESULTS: No significant difference was found among experimental groups (p=0.148). Cohesive failure located within the resilient material was predominantly observed in all tested groups. CONCLUSIONS: Peel bond strength between the denture base and the modified soft liner was not affected by the addition of antimicrobial agents.


Asunto(s)
Resinas Acrílicas/química , Antiinfecciosos/química , Recubrimiento Dental Adhesivo/métodos , Bases para Dentadura , Rebasado de Dentaduras/métodos , Clorhexidina/química , Fracaso de la Restauración Dental , Cetoconazol/química , Ensayo de Materiales , Miconazol/química , Nistatina/química , Reproducibilidad de los Resultados , Propiedades de Superficie , Resistencia a la Tracción , Agua/química
10.
Gerodontology ; 27(3): 230-5, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19555355

RESUMEN

OBJECTIVE: This study evaluated the effect of post-polymerisation treatments on the glass transition temperature (T(g)) of five hard chairside reline materials (Duraliner II-D, Kooliner-K, New Truliner-N, Ufi Gel hard-U and Tokuso Rebase Fast-T). MATERIALS AND METHODS: Specimens (10 x 10 x 1 mm) were made following the manufacturers' instructions and divided into three groups (n = 5). Control group specimens were left untreated. Specimens from the microwave group were irradiated with pre-determined power/time combinations, and specimens from the water-bath group were immersed in hot water at 55 degrees C for 10 min. Glass transition ( degrees C) was performed by differential scanning calorimetry. Data were analysed using anova, followed by post hoc Tukey's test (alpha = 0.05). RESULTS: Both post-polymerisation treatments promoted a significant (p < 0.05) increase in the T(g) of reline material K. Materials K, D and N showed the lowest T(g) (p < 0.05). No significant difference between T and U specimens was observed. CONCLUSION: Post-polymerisation treatments improved the glass transition of material Kooliner, with the effect being more pronounced for microwave irradiation.


Asunto(s)
Materiales Dentales/química , Alineadores Dentales , Vidrio/química , Resinas Acrílicas/química , Resinas Acrílicas/efectos de la radiación , Rastreo Diferencial de Calorimetría , Materiales Dentales/efectos de la radiación , Rebasado de Dentaduras , Vidrio/efectos de la radiación , Calor , Humanos , Ensayo de Materiales , Metacrilatos/química , Metacrilatos/efectos de la radiación , Microondas , Polimerizacion , Elastómeros de Silicona/química , Elastómeros de Silicona/efectos de la radiación , Factores de Tiempo , Temperatura de Transición , Agua/química
11.
Dent Mater ; 25(5): 662-71, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-19135715

RESUMEN

OBJECTIVES: This study evaluated the effect of water-bath post-polymerization at 55 degrees C for 10 min (WB) on the content and leaching of residual compounds, degree of conversion, flexural strength, and hardness of hard chairside reline resins (Kooliner: K, New Truliner: N, Ufi Gel hard: U, and Tokuso Rebase Fast: T). METHODS: Leaching experiments were made by storing specimens (n=48) in artificial saliva at 37+/-1 degrees C and analyzing residual monomers and plasticizer by HPLC. Analysis of residual monomer and plasticizer content (n=48) was also made by HPLC. Degree of conversion (n=40) was analyzed by using FT-Raman spectroscopy. A 3-point loading test was used to evaluate the flexural strength of the specimens (n=80). One fragment of each flexural test specimen was then submitted to Vickers microhardness test. RESULTS: WB produced a significant decrease (p<0.050) in the amount of residual compounds eluted from the materials within the first hour of immersion. With the exception of material U, WB decreased the duration of release of the residual compounds evaluated. All materials evaluated exhibited significantly (p<0.050) lower values of residual monomer and plasticizer (material N) after WB compared with the control groups. WB increased the degree of conversion of K and T resins and the hardness of N, K, and T resins (p<0.050). Only material K showed an increase in flexural strength after WB (p<0.050). SIGNIFICANCE: Immersion of relined dentures in water at 55 degrees C for 10 min can be used to reduce the amounts and duration of release of residual compounds and improve mechanical properties of some of the materials evaluated.


Asunto(s)
Resinas Acrílicas/química , Rebasado de Dentaduras , Cromatografía Líquida de Alta Presión , Dureza , Inmersión , Ensayo de Materiales , Metacrilatos/análisis , Transición de Fase , Ácidos Ftálicos/análisis , Plastificantes/análisis , Docilidad , Pirimidinas/análisis , Saliva Artificial , Espectroscopía Infrarroja por Transformada de Fourier , Agua
12.
Dent Mater ; 23(3): 363-8, 2007 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-16620950

RESUMEN

OBJECTIVES: This study compared the residual monomer (RM) in four hard chair-side reline resins (Duraliner II-D, Kooliner-K, Tokuso Rebase Fast-TRF and Ufi Gel hard-UGH) and one heat-polymerized denture base resin (Lucitone 550-L), which was processed using two polymerization cycles (short-LS and long-LL). It was also investigated the effect of two after polymerization treatments on this RM content. METHODS: Specimens (n=18) of each material were produced following the manufacturers' instructions and then divided into three groups. Group I specimens were left untreated (GI-control). Specimens of group II (GII) were given post-polymerization treatment by microwave irradiation. In group III (GIII), specimens were submitted to immersion in water at 55 degrees C (reline resins-10 min; denture base resin L-60 min). The RM was analyzed using high performance liquid chromatography (HPLC) and expressed as a percentage of RM. Data were analyzed by two-way ANOVA followed by Tukey's test (alpha=0.05). RESULTS: Comparing control specimens, statistical differences were found among all materials (p<0.05), and the results can be arranged as K (1.52%)>D (0.85%)>UGH (0.45%)>LL (0.24%)>TRF (0.14%)>LS (0.08%). Immersion in hot water (GIII) promoted a significant (p<0.05) reduction in the RM for all materials evaluated compared to control (GI), with the exception of LL specimens. Materials K, UGH and TRF exhibited significantly (p<0.05) lower values of RM after microwave irradiation (GII) than in the control specimens. SIGNIFICANCE: The reduction in RM promoted by water-bath and microwave post-polymerization treatments could improve the mechanical properties and biocompatibility of the relining and denture base materials.


Asunto(s)
Resinas Acrílicas/química , Alineadores Dentales , Rebasado de Dentaduras , Metacrilatos/análisis , Resinas Acrílicas/efectos de la radiación , Análisis de Varianza , Cromatografía Líquida de Alta Presión , Microondas , Transición de Fase , Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...