Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
BMJ Open ; 9(9): e030389, 2019 09 08.
Artículo en Inglés | MEDLINE | ID: mdl-31501123

RESUMEN

INTRODUCTION: Robotic guidance (RG) and computer-assisted navigation (NV) have seen increased adoption in instrumented spine surgery over the last decade. Although there exists some evidence that these techniques increase radiological pedicle screw accuracy compared with conventional freehand (FH) surgery, this may not directly translate to any tangible clinical benefits, especially considering the relatively high inherent costs. As a non-randomised, expertise-based study, the European Robotic Spinal Instrumentation Study aims to create prospective multicentre evidence on the potential comparative clinical benefits of RG, NV and FH in a real-world setting. METHODS AND ANALYSIS: Patients are allocated in a non-randomised, non-blinded fashion to the RG, NV or FH arms. Adult patients that are to undergo thoracolumbar pedicle screw instrumentation for degenerative pathologies, infections, vertebral tumours or fractures are considered for inclusion. Deformity correction and surgery at more than five levels represent exclusion criteria. Follow-up takes place at 6 weeks, as well as 12 and 24 months. The primary endpoint is defined as the time to revision surgery for a malpositioned or loosened pedicle screw within the first postoperative year. Secondary endpoints include patient-reported back and leg pain, as well as Oswestry Disability Index and EuroQOL 5-dimension questionnaires. Use of analgesic medication and work status are recorded. The primary analysis, conducted on the 12-month data, is carried out according to the intention-to-treat principle. The primary endpoint is analysed using crude and adjusted Cox proportional hazards models. Patient-reported outcomes are analysed using baseline-adjusted linear mixed models. The study is monitored according to a prespecified monitoring plan. ETHICS AND DISSEMINATION: The study protocol is approved by the appropriate national and local authorities. Written informed consent is obtained from all participants. The final results will be published in an international peer-reviewed journal. TRIAL REGISTRATION NUMBER: Clinical Trials.gov registry NCT03398915; Pre-results, recruiting stage.


Asunto(s)
Vértebras Lumbares , Tornillos Pediculares/efectos adversos , Complicaciones Posoperatorias , Reoperación , Procedimientos Quirúrgicos Robotizados , Enfermedades de la Columna Vertebral , Fusión Vertebral , Vértebras Torácicas , Europa (Continente)/epidemiología , Femenino , Humanos , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Masculino , Persona de Mediana Edad , Estudios Multicéntricos como Asunto , Estudios Observacionales como Asunto , Evaluación de Resultado en la Atención de Salud , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/cirugía , Reoperación/métodos , Reoperación/estadística & datos numéricos , Procedimientos Quirúrgicos Robotizados/efectos adversos , Procedimientos Quirúrgicos Robotizados/instrumentación , Procedimientos Quirúrgicos Robotizados/métodos , Enfermedades de la Columna Vertebral/diagnóstico por imagen , Enfermedades de la Columna Vertebral/epidemiología , Enfermedades de la Columna Vertebral/cirugía , Fusión Vertebral/efectos adversos , Fusión Vertebral/instrumentación , Fusión Vertebral/métodos , Cirugía Asistida por Computador/efectos adversos , Cirugía Asistida por Computador/instrumentación , Cirugía Asistida por Computador/métodos , Vértebras Torácicas/diagnóstico por imagen , Vértebras Torácicas/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA