1.
J Magn Reson Imaging ; 44(3): 683-97, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-26969867

RESUMEN

PURPOSE: To design and characterize a magnetic resonance imaging (MRI)-compatible aortic phantom simulating normal and aortic coarctation (AoCo) conditions and to compare its hemodynamics with healthy volunteers and AoCo patients. MATERIALS AND METHODS: The phantom is composed of an MRI-compatible pump, control unit, aortic model, compliance chamber, nonreturn, and shutoff valves. The phantom without and with AoCo (13, 11, and 9 mm) was studied using 2D and 3D phase-contrast data and with a catheterization unit to measure pressures. The phantom data were compared with the mean values of 10 healthy volunteers and two AoCo patients. RESULTS: Hemodynamic parameters in the normal phantom and healthy volunteers were: heart rate: 68/61 bpm, cardiac output: 3.5/4.5 L/min, peak flow and peak velocity (Vpeak) in the ascending aorta (AAo): 270/357 mL/s (significantly, P < 0.05) and 97/107 cm/s (not significantly, P = 0.16), and pressure in the AAo of the normal phantom of 131/58 mmHg. Hemodynamic parameters in the 13, 11, and 9 mm coarctation phantoms and Patients 1 and 2 were: heart rate: 75/75/75/97/78 bpm, cardiac output: 3.3/3.0/2.9/4.0/5.8 L/min, peak flow in the AAo: 245/265/215/244/376 mL/s, Vpeak in the AAo: 96/95/81/196/187 cm/s, Vpeak after the AoCo: 123/187/282/247/165 cm/s, pressure in the AAo: 124/56, 127/51, 133/50, 120/51 and 87/39 mmHg, and a trans-coarctation systolic pressure gradient: 7, 10, 30, 20, and 11 mmHg. CONCLUSION: We propose and characterize a normal and an AoCo phantom, whose hemodynamics, including velocity, flow, and pressure data are within the range of healthy volunteers and patients with AoCo. J. Magn. Reson. Imaging 2016;44:683-697.


Asunto(s)
Aorta/diagnóstico por imagen , Aorta/fisiopatología , Coartación Aórtica/diagnóstico por imagen , Coartación Aórtica/fisiopatología , Técnicas de Imagen Cardíaca/instrumentación , Angiografía por Resonancia Magnética/instrumentación , Fantasmas de Imagen , Velocidad del Flujo Sanguíneo , Cateterismo Cardíaco/métodos , Técnicas de Imagen Cardíaca/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Angiografía por Resonancia Magnética/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
2.
Magn Reson Imaging ; 33(8): 970-7, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26117696

RESUMEN

PURPOSE: To investigate the feasibility of estimating the portal vein blood volume that flows into the intrahepatic volume (IHPVBV) in each cardiac cycle using non-contrast MR venography technique as a surrogate marker of portal hypertension (PH). MATERIALS AND METHODS: Ten patients with chronic liver disease and clinical symptoms of PH (40% males, median age: 54.0, range: 44-73 years old) and ten healthy volunteers (80% males, median age: 54.0, range: 44-66 years old) were included in this study. A non-contrast Triple-Inversion-Recovery Arterial-Spin-Labeling (TIR-ASL) technique was used to quantify the IHPVBV in one and two cardiac cycles. Liver (LV) and spleen volumes (SV) were measured by manual segmentation from anatomical MR images as morphological markers of PH. All images were acquired in a 1.5T Philips Achieva MR scanner. RESULTS: PH patients had larger SV (P=0.02) and lower liver-to-spleen ratio (P=0.02) compared with healthy volunteers. The median IHPVBV in healthy volunteers was 13.5cm(3) and 26.5cm(3) for one and two cardiac cycles respectively, whereas in PH patients a median volume of 3.1cm(3) and 9.0cm(3) was observed. When correcting by LV, the IHPVBV was significantly higher in healthy volunteers than PH patients for one and two cardiac cycles. The combination of morphological information (liver-to-spleen ratio) and functional information (IHPVBV/LV) can accurately identify the PH patients with a sensitivity of 90% and specificity of 100%. CONCLUSION: Results show that the portal vein blood volume that flows into the intrahepatic volume in one and two cardiac cycles is significantly lower in PH patients than in healthy volunteers and can be quantified with non-contrast MRI techniques.


Asunto(s)
Determinación del Volumen Sanguíneo/métodos , Volumen Sanguíneo , Hipertensión Portal/diagnóstico , Hipertensión Portal/fisiopatología , Angiografía por Resonancia Magnética/métodos , Vena Porta/fisiopatología , Adulto , Anciano , Medios de Contraste , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Persona de Mediana Edad , Vena Porta/patología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
3.
J Magn Reson Imaging ; 39(4): 1027-32, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24136653

RESUMEN

PURPOSE: To measure both transversal relaxation time (T2 ) and diffusion coefficients within a single scan using a multi-shot approach. Both measurements have drawn interest in many applications, especially in skeletal muscle studies, which have short T2 values. Multiple echo single-shot schemes have been proposed to obtain those variables simultaneously within a single scan, resulting in a reduction of the scanning time. However, one problem with those approaches is the associated long echo read-out. Consequently, the minimum achievable echo time tends to be long, limiting the application of these sequences to tissues with relatively long T2 . MATERIALS AND METHODS: To address this problem, we propose to extend the multi-echo sequences using a multi-shot approach, so that to allow shorter echo times. A multi-shot dual-echo EPI sequence with diffusion gradients and echo navigators was modified to include independent diffusion gradients in any of the two echoes. RESULTS: The multi-shot approach allows us to drastically reduce echo times. Results showed a good agreement for the T2 and mean diffusivity measurements with gold standard sequences in phantoms and in vivo data of calf muscles from healthy volunteers. CONCLUSION: A fast and accurate method is proposed to measure T2 and diffusion coefficients simultaneously, tested in vitro and in healthy volunteers.


Asunto(s)
Algoritmos , Imagen de Difusión por Resonancia Magnética/métodos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Músculo Esquelético/anatomía & histología , Procesamiento de Señales Asistido por Computador , Adulto , Femenino , Humanos , Pierna , Masculino , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
4.
Radiology ; 263(2): 547-54, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22517963

RESUMEN

PURPOSE: To identify which rest phase (systolic or diastolic) is optimum for assessing or measuring cardiac structures in the setting of three-dimensional (3D) whole-heart imaging in congenital heart disease (CHD). MATERIALS AND METHODS: The study was approved by the institutional review board; informed consent was obtained. Fifty children (26 male and 24 female patients) underwent 3D dual-phase whole-heart imaging. Cardiac structures were analyzed for contrast-to-noise ratio (CNR) and image quality. Cross-sectional measurements were taken of the aortic arch, right ventricular (RV) outflow tract (RVOT) and pulmonary arteries. Normally distributed variables were compared by using paired t tests, and categorical data were compared by using Wilcoxon signed-rank test. RESULTS: Mean CNR and image quality were significantly (all P < .05) greater in systole for the right atrium (CNR, 8.9 vs 7.5; image quality, 438 vs 91), left atrium (CNR, 8.0 vs 5.3; image quality, 1006 vs 29), RV (CNR, 10.6 vs 8.2; image quality, 131 vs 23), LV (CNR, 9.4 vs 7.7; image quality, 125 vs 28), and pulmonary veins (CNR, 6.2 vs 4.9; image quality, 914 vs 32). Conversely, diastolic CNR was significantly higher in the aorta (9.2 vs 8.2; P = .013) and diastolic image quality was higher for the left pulmonary artery (238 vs 62; P = .007), right pulmonary artery (219 vs 35; P < .001), and for imaging of an area after an arterial stenosis (164 vs 7; P < .001). All aortic arch and RVOT cross-sectional measurements were significantly (P < .05) greater in systole (narrowest point of arch, 70 vs 53 mm(2); descending aorta, 71 vs 58 mm(2); transverse arch, 293 vs 275 mm(2); valvar RVOT, 291 vs 268 mm(2); supravalvar RVOT, 337 vs 280 mm(2); prebifurcation RVOT, 329 vs 259 mm(2)). CONCLUSION: Certain structures in CHD are better imaged in systole and others in diastole, and therefore, the dual-phase approach allows a higher overall success rate. This approach also allows depiction of diameter changes between systole and diastole and is therefore preferable to standard single-phase sequences for the planning of interventional procedures.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas/métodos , Cardiopatías Congénitas/diagnóstico , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Adolescente , Niño , Preescolar , Diástole , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Lactante , Recién Nacido , Masculino , Estadísticas no Paramétricas , Sístole
5.
Quintessence Int ; 38(2): e99-105, 2007 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17510721

RESUMEN

Sealing of incipient carious lesions in occlusal surfaces has been shown to arrest the progression of the lesions. In this report, we describe for approximal surfaces with noncavitated incipient lesions the clinical procedures for sealant application illustrating this minimally invasive method with 3 clinical cases and scanning electron microscopic images.


Asunto(s)
Caries Dental/terapia , Selladores de Fosas y Fisuras/uso terapéutico , Adulto , Cariostáticos/uso terapéutico , Niño , Caries Dental/diagnóstico por imagen , Fluoruros/uso terapéutico , Humanos , Selladores de Fosas y Fisuras/química , Radiografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...