Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Rev. chil. radiol ; 18(4): 157-162, 2012. ilus, tab
Artículo en Español | LILACS | ID: lil-665604

RESUMEN

Objective. To validate the utility of 4D Blood Flow and Navier-Stokes equations to create relative pressure (RP) maps in the aorta and pulmonary artery (PA) in healthy volunteers and patients with repaired tetralogy of Fallot (TOF). Methods. A 4D flow sequence of whole heart and its major vessels was acquired in 10 healthy volunteers and 6 patients with repaired TOF. The root of the ascending aorta was used as the reference point to calculate RP along five different points of this area. In addition, relative pressure of both right and left PA was measured as correlated to absolute pressure. Results. Patients with repaired TOF showed greater pulmonary artery (PA) relative pressure differences between maximum and minimum values when compared to volunteers (p <0.05). Additionally, aortic relative pressures had an excellent correlation with published data, whether using 4D flow or by catheterization. Conclusions. 4D Flow MRI may represent a new non-invasive and non operator-dependent diagnostic tool in CV disease management.


Objetivo. Utilizar 4D Flow y las ecuaciones de Navier-Stokes para obtener mapas de presiones relativas (PR) en la Aorta y Arteria Pulmonar (AP) de voluntarios y pacientes con Tetralogía de Fallot reparada (TOFr). Métodos. En 10 voluntarios y 6 pacientes con TOFr se adquirió la secuencia 4D flow del corazón y sus principales vasos. La raíz de la Aorta Ascendente se utilizó como referencia para calcular las PR a esta zona en cinco puntos distintos. Además, se midió la PR de la AP derecha e izquierda respecto a la AP. Resultados. Los pacientes con TOFr tuvieron diferencias de PR entre los valores máximos y mínimos más grandes que los voluntarios en la AP (p<0,05). Adicionalmente, las PR de la aorta tuvieron una excelente correlación con datos publicados utilizando 4D flow y mediante cateterización. Conclusiones. 4D Flow podría constituir una nueva herramienta diagnóstica, no invasiva, ni operador dependiente, en el manejo de patologías CV.


Asunto(s)
Persona de Mediana Edad , Aorta Torácica/fisiopatología , Arteria Pulmonar/fisiopatología , Imagen por Resonancia Magnética , Tetralogía de Fallot/fisiopatología , Velocidad del Flujo Sanguíneo , Presión
2.
Rev. chil. radiol ; 18(2): 62-67, 2012. ilus, tab
Artículo en Español | LILACS | ID: lil-647002

RESUMEN

Objective: Hemodynamic parameters are critical to perform a proper diagnosis. However, due to the large number of variables that can be obtained, overall analysis may represent a complex task. To facilitate this, we propose to create a model for classifying different hemodynamic variables between those belonging to a healthy individual and to a pathological patient. For this purpose, we employed data mining techniques to identify relationships among various aortic hemodynamic parameters obtained through multi-dimensional (4D flow) MR imaging. Method: A 4D flow sequence of whole heart and great vessels was acquired using MRI in 19 healthy volunteers and 2 patients (one with aortic coarctation and one with repaired coarctation of the aorta). Retrospectively, data were reformatted along the aorta; three MRI acquisitions were performed for volunteers and 30 sequences for each patient. In each slice the aorta was segmented and various parameters were quantified: area, maximum velocity, minimum velocity, flow and volumen, with following values being calculated for last four parameters: maximum, average, standard deviation, kurtosis, skewness, proportion of time to reach the maximum value, among others. A total of 26 variables for each acquisition were obtained. In order to classify data, the CART Technique (Classification and Regression Trees) was applied. To validate the model, two extra projections were generated per each volunteer and 20 slice per each patient. Results: By using only 7 variables, the CART Technique allows discrimination between images performed either on volunteers or patients with an error rate of 14.1 percent, a sensitivity of 82.5 percent, and a specificity of 89.4 percent. Conclusions: 4D flow MR imaging provides a wealth of hemodynamic data that can be difficult to analyze. In this paper we demonstrate that by using data mining techniques it is possible to classify images from relevant hemodynamic parameters and their relationships in order...


Objetivo: Los parámetros hemodinámicos son de gran utilidad para realizar un adecuado diagnóstico. Sin embargo, debido a la gran cantidad de variables que pueden obtenerse, el análisis global de todas ellas puede ser complejo. Para facilitar esta tarea, nosotros proponemos crear un modelo que permita clasificar distintas variables hemodinámicas entre las pertenecientes a un individuo sano o a uno patológico. Para ello, usaremos técnicas de minería de datos que permitan identificar y encontrar relaciones entre distintos parámetros hemodinámicos de la aorta obtenidos a través de flujo multidimensional (4D flow) por resonancia magnética. Método: Una secuencia 4D flow de todo el corazón y los grandes vasos fue adquirida utilizando resonancia magnética en 19 voluntarios sanos y 2 pacientes (uno con una coartación aórtica y otro con una coartación aórtica reparada). Retrospectivamente, los datos fueron reformateados a lo largo de la aorta, originándose 3 cortes en los voluntarios y 30 cortes en cada paciente. En cada corte la aorta fue segmentada y distintos parámetros fueron cuantificados: área, velocidad máxima, velocidad mínima, flujo y volumen, calculándose en los cuatro últimos su valor máximo, promedio, desviación estándar, curtosis, sesgo, proporción de tiempo en alcanzar el valor máximo, entre otros. Teniendo un total de 26 variables por cada corte. Se aplicó la técnica de árboles de decisión tipo CART (por sus siglas en inglés) para clasificar los datos. Para validar el modelo, 2 cortes extras fueron generados por cada voluntario y 20 cortes por cada paciente. Resultados: La técnica CART, mediante la utilización de sólo 7 variables, puede clasificar las imágenes de los voluntarios y pacientes con una tasa de error del 14,1 por ciento, una sensibilidad de 82,5 por ciento y una especificidad de 89.4 por ciento. Conclusiones: 4D flow provee una gran cantidad de datos hemodinámicos que son difíciles de analizar. En este trabajo demostramos que al utilizar...


Asunto(s)
Humanos , Aorta/fisiopatología , Técnicas de Imagen Cardíaca , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Velocidad del Flujo Sanguíneo/fisiología , Aumento de la Imagen/métodos , Minería de Datos , Árboles de Decisión , Enfermedades Cardiovasculares/diagnóstico , Hemodinámica , Flujo Sanguíneo Regional , Análisis de Regresión , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
3.
Rev. chil. radiol ; 17(4): 183-191, 2011. ilus, graf, tab
Artículo en Español | LILACS | ID: lil-627524

RESUMEN

Background. Increase in visceral fat is associated to the development of fatty liver and liver fibrosis. Hepatic elastography is a novel noninvasive method for assessing liver fibrosis. Objective. To evaluate the relationship between visceral adipose tissue volume (VAT), subcutaneous adipose tissue volume (SAT) as measured by Magnetic Resonance Imaging (MRI) and transient elastography (TrE) values using ARFI (Acoustic Radiation Force Impulse) in type 2 Diabetic Mellitus patients (DM2). Methods. We included 20 DM2 patients (mean age: 62 years, range: 55-75, mean weight: 77.8 kg, range: 61.5-97). Patients underwent an MRI study in a Philips Intera 1.5T scanner. MR imaging protocol included a spectral excitation sequence centered on the fat peak. The sequence included 32 cross sections, 7mm thick, from the diaphragmatic cupula to the inferior border of the kidney. VAT was measured by using the semiautomatic Image J software. Each patient underwent a hepatic elastograpy (HE); 10 ARFI measurements were performed in the right hepatic lobe. Finally, a statistical analysis was performed by applying Pearson correlation between abdominal fat volumes and ARFI scores Results. Mean VAT was 2472 +/- 861 cc, (1173-4020 cc), whilst the mean ARFI was 1.62 ± 0.8 m/s, (0.8-3.4 m/s). Correlations obtained were r=0.08 between VAT and ARFI (p=0.72); 0.13 between SAT and ARFI (p=0.57), and -0.06 between (VAT+SAT) and ARFI (p=0.77). By subdividing the sample universe, we observed that the group with ARFI scores greater than 1.6 m/s (7 patients) had a correlation of 0.63 between VAT and ARFI (p=0.12); of 0.66 between SAT and ARFI (p=0.10), and of 0.94 between VAT+SAT and ARFI (p=0.001). In the subgroup with ARFI values inferior to 1.6 m/s (13 patients), the correlation was of 0.11 between VAT and ARFI (p=0.71); of 0.26 between SAT and ARFI (p=0.38), and of 0.32 between ( VAT+SAT) and ARFI (p=0.28). When adjusted for gender, ARFI scores greater than.


Introducción. La acumulación de grasa visceral se asocia al desarrollo de enfermedad hepática. La elastografía hepática es un método novedoso no invasivo para evaluar fibrosis hepática. Objetivo. Evaluar la relación entre el volumen de tejido adiposo visceral (VAT), volumen de tejido adiposo subcutáneo (SAT) medido por resonancia magnética (RM), con índices de elastografía hepática (EH) utilizando ARFI (fuerza de impulso de radiación acústica) en pacientes con Diabetes Mellitus tipo 2 (DM2). Métodos. Fueron incluidos 20 pacientes (edad promedio: 62 años, rango: 55-75 años, peso promedio: 77,8 kg, rango: 61,5-97 kg) con DM2. Los pacientes se sometieron a un examen de RM en un resonador Philips Intera 1.5T. Al protocolo de RM se agregó una secuencia de excitación espectral centrada en el peak de grasa. La secuencia incluyó 32 cortes transversales, grosor 7mm, desde la cúpula diafragmática hasta el borde inferior renal. En las imágenes se midió VAT utilizando el software Image J (freeware). En cada paciente se realizó una EH, utilizando ARFI con 10 medidas en lóbulo hepático derecho. Finalmente, se realizó un análisis estadístico a través de la correlación de Pearson entre los volúmenes de grasa abdominal y ARFI. Resultados. El promedio de VAT fue 2472 +/- 861 cc, (1173-4020 cc), el promedio de ARFI fue 1,62 ± 0,8 m/s, (0,8-3,4 m/s). Se obtuvieron correlaciones de r=-0,08 entre VAT y ARFI (p=0,72), de 0,13 entre SAT y ARFI (p=0,57), y de -0,06 entre (VAT+SAT) con ARFI (p=0,77). Subdividiendo el universo muestral, se encontró que el grupo con ARFI mayor que 1,6 m/s (7 pacientes) obtuvo una correlación de 0,63 entre VAT y ARFI (p=0,12), de 0,66 entre SAT y ARFI (p=0,10), y de 0,94 entre (VAT+SAT) con ARFI (p=0,001). En el subgrupo con ARFI inferior a 1,6 m/s (13 pacientes) la correlación fue 0,11 entre VAT y ARFI (p=0,71), de 0,26 entre SAT y ARFI (p=0,38), y de 0,32 entre (VAT+SAT) y ARFI (p=0,28).


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , /patología , Diagnóstico por Imagen de Elasticidad/métodos , Grasa Intraabdominal/anatomía & histología , Hígado/patología , Cirrosis Hepática/diagnóstico , Hígado Graso/diagnóstico , Imagen por Resonancia Magnética , Medición de Riesgo , Tejido Adiposo/anatomía & histología
4.
Rev. chil. radiol ; 17(3): 134-140, 2011. ilus
Artículo en Español | LILACS | ID: lil-608816

RESUMEN

Purpose. To demonstrate the utility of 4D flow MR imaging for analyzing blood flow patterns and flow distribution in patients with congenital heart diseases. Methods: Six patients with congenital heart diseases were scanned using a standard cardiac MRI protocol, according to their condition. Additionally, 2D flow sequences of the great vessels, and a 4D flow sequence covering the entire heart were acquired. Flow patterns were visualized by using vector fields, streamlines and particle traces. Results: 4D flow technique depicted vortices and helical flow in the pulmonary artery of most patients, as well as in the aorta and superior vena cava of one patient with corrected aortic coarctation and a levoatrial cardinal vein. Conclusion: 4D flow MR imaging enables the identification of flow patterns difficult to detect with other diagnostic modalities. Comprehensive evaluation of flow patterns might help to understand the hemodynamic consequences of congenital heart diseases and their surgical procedures.


Objetivo. Demostrar la utilidad de 4D flow para el análisis de patrones y distribución de flujos en pacientes con cardiopatías congénitas. Métodos: Seis pacientes con cardiopatías congénitas fueron escaneados con un protocolo de resonancia magnética cardíaca estándar. Además se incluyeron secuencias de flujo 2D en los principales vasos del tórax y una secuencia 4D flow que cubría todo el corazón. Para la visualización de los patrones de flujo se emplearon vectores de velocidad, líneas de flujo y trazadores de partículas. Resultados: 4D flow reveló vórtices y hélices en la arteria pulmonar de la mayoría de los pacientes, y en la aorta y vena cava superior de un paciente con coartación aórtica reparada y vena cardinal levoatrial. Conclusiones: 4D flow permite identificar patrones de flujo en pacientes con cardiopatías congénitas, difíciles de observar con otros métodos diagnósticos. La evaluación de patrones de flujo podría contribuir a comprender las consecuencias hemodinámicas de diferentes cardiopatías congénitas.


Asunto(s)
Humanos , Masculino , Adolescente , Adulto , Femenino , Niño , Persona de Mediana Edad , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/fisiopatología , Imagen por Resonancia Magnética/métodos , Velocidad del Flujo Sanguíneo/fisiología , Aorta Torácica/fisiopatología , Arteria Pulmonar/fisiopatología , Aumento de la Imagen/métodos , Coartación Aórtica/fisiopatología , Flujo Sanguíneo Regional , Vena Cava Superior/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...