Resuscitation ; 200: 110259, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38823474

RESUMEN

BACKGROUND: Interpretation of end-tidal CO2 (ETCO2) during manual cardiopulmonary resuscitation (CPR) is affected by variations in ventilation and chest compressions. This study investigates the impact of standardising ETCO2 to constant ventilation rate (VR) and compression depth (CD) on absolute values and trends. METHODS: Retrospective study of out-of-hospital cardiac arrest cases with manual CPR, including defibrillator and clinical data. ETCO2, VR and CD values were averaged by minute. ETCO2 was standardised to 10 vpm and 50 mm. We compared standardised (ETs) and measured (ETm) values and trends during resuscitation. RESULTS: Of 1,036 cases, 287 met the inclusion criteria. VR was mostly lower than recommended, 8.8 vpm, and highly variable within and among patients. CD was mostly within guidelines, 49.8 mm, and less varied. ETs was lower than ETm by 7.3 mmHg. ETs emphasized differences by sex (22.4 females vs. 25.6 mmHg males), initial rhythm (29.1 shockable vs. 22.7 mmHg not), intubation type (25.6 supraglottic vs. 22.4 mmHg endotracheal) and return of spontaneous circulation (ROSC) achieved (34.5 mmHg) vs. not (20.1 mmHg). Trends were different between non-ROSC and ROSC patients before ROSC (-0.3 vs. + 0.2 mmHg/min), and between sustained and rearrest after ROSC (-0.7 vs. -2.1 mmHg/min). Peak ETs was higher for sustained than for rearrest (53.0 vs. 42.5 mmHg). CONCLUSION: Standardising ETCO2 eliminates effects of VR and CD variations during manual CPR and facilitates comparison of values and trends among and within patients. Its clinical application for guidance of resuscitation warrants further investigation.


Asunto(s)
Dióxido de Carbono , Reanimación Cardiopulmonar , Paro Cardíaco Extrahospitalario , Humanos , Reanimación Cardiopulmonar/métodos , Reanimación Cardiopulmonar/normas , Masculino , Femenino , Estudios Retrospectivos , Paro Cardíaco Extrahospitalario/terapia , Persona de Mediana Edad , Dióxido de Carbono/análisis , Anciano , Capnografía/métodos , Volumen de Ventilación Pulmonar/fisiología
2.
Heliyon ; 10(7): e28739, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38601572

RESUMEN

Aim: Propose new metrics of impulsiveness of manual chest compressions (CCs) that account for shape and duration, separate the characteristics of the compressive part of the CC cycle from those of the recoil part, and are uncorrelated to CC depth and rate. Methods: We conducted a retrospective analysis of adult out-of-hospital cardiac arrest monitor-defibrillator recordings having CPR data. Specifically, episodes of adult patients with ≥ 1000 compressions free of leaning were examined. CCs were obtained from the depth signal of the valid episodes, and we calculated the novel metrics: compression area index (CAI), recoil area index (RAI), compression impulsiveness index (CII) and recoil impulsiveness index (RII). Generalized linear mixed-effects models and Jonckheere-Terpstra trend analyses were employed to measure differences between populations and trends, and the absolute value of Pearson's correlation coefficient |r| was used to report dependence between variables. Statistics are reported as median and interquartile range. Results: We analyzed 982,340 CCs corresponding to 453 episodes, for which we calculated their CAI, RAI and duty cycle (DC). We analyzed the metrics for various populations: age, sex, any ROSC achieved and disposition, and found that CAI was significantly different according to patient disposition and RAI relative to age and sex (p<0.05). None of the metrics was correlated strongly to depth or rate (|r| values of 0.22 or smaller), and all of them varied for CC series corresponding to the same rescuer over the course of resuscitation (ptrend<0.05). However, we observed that the metrics are not balanced, in that for any value of DC, CAI and RAI span almost their entire ranges. Conclusion: The proposed metrics correctly and completely describe manual CC waveforms, improve upon the DC, since they depend on the signal waveform, and provide additional information to current indicators of quality CPR, depth and rate. Furthermore, they allow to differentiate the compressive and recoil parts of the CC cycle, reflecting influence of the rescuer (via CAI or CII) and of the biomechanics of the patient's chest (via RAI or RII). Thus, they have the potential to contribute to better understanding CPR dynamics and, eventually, to enhanced quality of CPR practice as additional indicators of proper manual CC technique.

3.
J Clin Med ; 12(21)2023 Nov 03.
Artículo en Inglés | MEDLINE | ID: mdl-37959385

RESUMEN

Background: There is growing interest in the quality of manual ventilation during cardiopulmonary resuscitation (CPR), but accurate assessment of ventilation parameters remains a challenge. Waveform capnography is currently the reference for monitoring ventilation rate in intubated patients, but fails to provide information on tidal volumes and inspiration-expiration timing. Moreover, the capnogram is often distorted when chest compressions (CCs) are performed during ventilation compromising its reliability during CPR. Our main purpose was to characterize manual ventilation during CPR and to assess how CCs may impact on ventilation quality. Methods: Retrospective analysis were performed of CPR recordings fromtwo databases of adult patients in cardiac arrest including capnogram, compression depth, and airway flow, pressure and volume signals. Using automated signal processing techniques followed by manual revision, individual ventilations were identified and ventilation parameters were measured. Oscillations on the capnogram plateau during CCs were characterized, and its correlation with compression depth and airway volume was assessed. Finally, we identified events of reversed airflow caused by CCs and their effect on volume and capnogram waveform. Results: Ventilation rates were higher than the recommended 10 breaths/min in 66.7% of the cases. Variability in ventilation rates correlated with the variability in tidal volumes and other ventilatory parameters. Oscillations caused by CCs on capnograms were of high amplitude (median above 74%) and were associated with low pseudo-volumes (median 26 mL). Correlation between the amplitude of those oscillations with either the CCs depth or the generated passive volumes was low, with correlation coefficients of -0.24 and 0.40, respectively. During inspiration and expiration, reversed airflow events caused opposed movement of gases in 80% of ventilations. Conclusions: Our study confirmed lack of adherence between measured ventilation rates and the guideline recommendations, and a substantial dispersion in manual ventilation parameters during CPR. Oscillations on the capnogram plateau caused by CCs did not correlate with compression depth or associated small tidal volumes. CCs caused reversed flow during inspiration, expiration and in the interval between ventilations, sufficient to generate volume changes and causing oscillations on capnogram. Further research is warranted to assess the impact of these findings on ventilation quality during CPR.

4.
Comput Methods Programs Biomed ; 242: 107847, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37852146

RESUMEN

AIM: The purpose of this study was to develop a simple viscoelastic model to characterize the mechanical properties of chests during manual chest compressions in pre-hospital cardiopulmonary resuscitation (CPR). METHODS: Force and acceleration signals were extracted from CPR monitors used during pre-hospital resuscitation attempts on adult patients. Individual chest compressions were identified and segmented from the chest displacement computed using the force and acceleration. Each compression-recoil cycle was characterized by its elastic coefficient k (a measure of stiffness) and its compression and recoil damping coefficients, dc and dr, respectively (measures of viscosity). We compared the estimated and the calculated chest displacement to assess the goodness of fit of the model. We characterized the chest of patients at the beginning of CPR in relation to sex and age, and their variation as CPR progressed. RESULTS: A total of 1,156,608 chest compressions from 615 patients were analysed. Mean (95% CI) coefficient of determination R2 for the viscoelastic model was 97.9% (97.8-98.1). At the beginning of CPR, k was 104.9 N⋅cm-1 (102.0-107.8), dc was 2.868 N⋅s⋅cm-1 (2.751-2.984) and dr was 4.889 N⋅s⋅cm-1 (4.648-5.129). Damping during recoil was significantly higher than during compression. Stiffness was lower in women than in men. There were no differences in damping coefficients with sex but a higher dr with increasing age. All model coefficients decreased with compression count, with an overall decrease after 3,000 chest compressions of 34.6%, 48.8% and 37.2%, respectively. CONCLUSION: The model accurately described adult chest mechanical properties during CPR, highlighting differences between compression and recoil, sex and age, and a progressive reduction in chest stiffness and viscosity along resuscitation. Our findings may merit further investigation into whether patient-tailored and time-sensitive chest compression technique may be appropriate.


Asunto(s)
Reanimación Cardiopulmonar , Masculino , Humanos , Adulto , Femenino , Tórax , Presión , Hospitales
5.
PLoS One ; 12(9): e0184044, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28922360

RESUMEN

Idiopathic epilepsy is characterized by generalized seizures with no apparent cause. One of its main problems is the lack of biomarkers to monitor the evolution of patients. The only tools they can use are limited to inspecting the amount of seizures during previous periods of time and assessing the existence of interictal discharges. As a result, there is a need for improving the tools to assist the diagnosis and follow up of these patients. The goal of the present study is to compare and find a way to differentiate between two groups of patients suffering from idiopathic epilepsy, one group that could be followed-up by means of specific electroencephalographic (EEG) signatures (intercritical activity present), and another one that could not due to the absence of these markers. To do that, we analyzed the background EEG activity of each in the absence of seizures and epileptic intercritical activity. We used the Shannon spectral entropy (SSE) as a metric to discriminate between the two groups and performed permutation-based statistical tests to detect the set of frequencies that show significant differences. By constraining the spectral entropy estimation to the [6.25-12.89) Hz range, we detect statistical differences (at below 0.05 alpha-level) between both types of epileptic patients at all available recording channels. Interestingly, entropy values follow a trend that is inversely related to the elapsed time from the last seizure. Indeed, this trend shows asymptotical convergence to the SSE values measured in a group of healthy subjects, which present SSE values lower than any of the two groups of patients. All these results suggest that the SSE, measured in a specific range of frequencies, could serve to follow up the evolution of patients suffering from idiopathic epilepsy. Future studies remain to be conducted in order to assess the predictive value of this approach for the anticipation of seizures.


Asunto(s)
Electroencefalografía/métodos , Procesamiento Automatizado de Datos/métodos , Epilepsia/fisiopatología , Adolescente , Adulto , Anciano , Niño , Femenino , Humanos , Masculino , Persona de Mediana Edad
6.
J Neural Eng ; 12(3): 031001, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25834104

RESUMEN

This paper presents an extensive review on the artifact removal algorithms used to remove the main sources of interference encountered in the electroencephalogram (EEG), specifically ocular, muscular and cardiac artifacts. We first introduce background knowledge on the characteristics of EEG activity, of the artifacts and of the EEG measurement model. Then, we present algorithms commonly employed in the literature and describe their key features. Lastly, principally on the basis of the results provided by various researchers, but also supported by our own experience, we compare the state-of-the-art methods in terms of reported performance, and provide guidelines on how to choose a suitable artifact removal algorithm for a given scenario. With this review we have concluded that, without prior knowledge of the recorded EEG signal or the contaminants, the safest approach is to correct the measured EEG using independent component analysis-to be precise, an algorithm based on second-order statistics such as second-order blind identification (SOBI). Other effective alternatives include extended information maximization (InfoMax) and an adaptive mixture of independent component analyzers (AMICA), based on higher order statistics. All of these algorithms have proved particularly effective with simulations and, more importantly, with data collected in controlled recording conditions. Moreover, whenever prior knowledge is available, then a constrained form of the chosen method should be used in order to incorporate such additional information. Finally, since which algorithm is the best performing is highly dependent on the type of the EEG signal, the artifacts and the signal to contaminant ratio, we believe that the optimal method for removing artifacts from the EEG consists in combining more than one algorithm to correct the signal using multiple processing stages, even though this is an option largely unexplored by researchers in the area.


Asunto(s)
Algoritmos , Artefactos , Encéfalo/fisiología , Electroencefalografía/métodos , Electroencefalografía/normas , Guías de Práctica Clínica como Asunto , Interpretación Estadística de Datos , Diagnóstico por Computador/métodos , Diagnóstico por Computador/normas , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad