Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
2.
Anal Chem ; 96(14): 5478-5488, 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38529642

RESUMEN

PubChem serves as a comprehensive repository, housing over 100 million unique chemical structures representing the breadth of our chemical knowledge across numerous fields including metabolism, pharmaceuticals, toxicology, cosmetics, agriculture, and many more. Rapid identification of these small molecules increasingly relies on electrospray ionization (ESI) paired with tandem mass spectrometry (MS/MS), particularly by comparison to genuine standard MS/MS data sets. Despite its widespread application, achieving consistency in MS/MS data across various analytical platforms remains an unaddressed concern. This study evaluated MS/MS data derived from one hundred molecular standards utilizing instruments from five manufacturers, inclusive of quadrupole time-of-flight (QTOF) and quadrupole orbitrap "exactive" (QE) mass spectrometers by Agilent (QTOF), Bruker (QTOF), SCIEX (QTOF), Waters (QTOF), and Thermo QE. We assessed fragment ion variations at multiple collisional energies (0, 10, 20, and 40 eV) using the cosine scoring algorithm for comparisons and the number of fragments observed. A parallel visual analysis of the MS/MS spectra across instruments was conducted, consistent with a standard procedure that is used to circumvent the still prevalent issue of mischaracterizations as shown for dimethyl sphingosine and C20 sphingosine. Our analysis revealed a notable consistency in MS/MS data and identifications, with fragment ions' m/z values exhibiting the highest concordance between instrument platforms at 20 eV, the other collisional energies (0, 10, and 40 eV) were significantly lower. While moving toward a standardized ESI MS/MS protocol is required for dependable molecular characterization, our results also underscore the continued importance of corroborating MS/MS data against standards to ensure accurate identifications. Our findings suggest that ESI MS/MS manufacturers, akin to the established norms for gas chromatography mass spectrometry instruments, should standardize the collision energy at 20 eV across different instrument platforms.


Asunto(s)
Esfingosina , Espectrometría de Masas en Tándem , Espectrometría de Masas en Tándem/métodos , Espectrometría de Masa por Ionización de Electrospray/métodos , Cromatografía de Gases y Espectrometría de Masas , Iones
4.
Nat Commun ; 10(1): 5811, 2019 12 20.
Artículo en Inglés | MEDLINE | ID: mdl-31862874

RESUMEN

Machine learning has been extensively applied in small molecule analysis to predict a wide range of molecular properties and processes including mass spectrometry fragmentation or chromatographic retention time. However, current approaches for retention time prediction lack sufficient accuracy due to limited available experimental data. Here we introduce the METLIN small molecule retention time (SMRT) dataset, an experimentally acquired reverse-phase chromatography retention time dataset covering up to 80,038 small molecules. To demonstrate the utility of this dataset, we deployed a deep learning model for retention time prediction applied to small molecule annotation. Results showed that in 70[Formula: see text] of the cases, the correct molecular identity was ranked among the top 3 candidates based on their predicted retention time. We anticipate that this dataset will enable the community to apply machine learning or first principles strategies to generate better models for retention time prediction.


Asunto(s)
Cromatografía de Fase Inversa , Aprendizaje Profundo , Espectrometría de Masas , Modelos Químicos , Bibliotecas de Moléculas Pequeñas/aislamiento & purificación , Conjuntos de Datos como Asunto , Bibliotecas de Moléculas Pequeñas/química , Factores de Tiempo
5.
Anal Chem ; 90(5): 3156-3164, 2018 03 06.
Artículo en Inglés | MEDLINE | ID: mdl-29381867

RESUMEN

METLIN originated as a database to characterize known metabolites and has since expanded into a technology platform for the identification of known and unknown metabolites and other chemical entities. Through this effort it has become a comprehensive resource containing over 1 million molecules including lipids, amino acids, carbohydrates, toxins, small peptides, and natural products, among other classes. METLIN's high-resolution tandem mass spectrometry (MS/MS) database, which plays a key role in the identification process, has data generated from both reference standards and their labeled stable isotope analogues, facilitated by METLIN-guided analysis of isotope-labeled microorganisms. The MS/MS data, coupled with the fragment similarity search function, expand the tool's capabilities into the identification of unknowns. Fragment similarity search is performed independent of the precursor mass, relying solely on the fragment ions to identify similar structures within the database. Stable isotope data also facilitate characterization by coupling the similarity search output with the isotopic m/ z shifts. Examples of both are demonstrated here with the characterization of four previously unknown metabolites. METLIN also now features in silico MS/MS data, which has been made possible through the creation of algorithms trained on METLIN's MS/MS data from both standards and their isotope analogues. With these informatic and experimental data features, METLIN is being designed to address the characterization of known and unknown molecules.


Asunto(s)
Extractos Celulares/análisis , Bases de Datos de Compuestos Químicos/estadística & datos numéricos , Conjuntos de Datos como Asunto/estadística & datos numéricos , Metabolómica/métodos , Metabolómica/estadística & datos numéricos , Pichia/química , Pichia/metabolismo , Espectrometría de Masas en Tándem/estadística & datos numéricos
6.
Anal Chem ; 89(21): 11505-11513, 2017 11 07.
Artículo en Inglés | MEDLINE | ID: mdl-28945073

RESUMEN

Concurrent exposure to a wide variety of xenobiotics and their combined toxic effects can play a pivotal role in health and disease, yet are largely unexplored. Investigating the totality of these exposures, i.e., the "exposome", and their specific biological effects constitutes a new paradigm for environmental health but still lacks high-throughput, user-friendly technology. We demonstrate the utility of mass spectrometry-based global exposure metabolomics combined with tailored database queries and cognitive computing for comprehensive exposure assessment and the straightforward elucidation of biological effects. The METLIN Exposome database has been redesigned to help identify environmental toxicants, food contaminants and supplements, drugs, and antibiotics as well as their biotransformation products, through its expansion with over 700 000 chemical structures to now include more than 950 000 unique small molecules. More importantly, we demonstrate how the XCMS/METLIN platform now allows for the readout of the biological effect of a toxicant through metabolomic-derived pathway analysis, and further, artificial intelligence provides a means of assessing the role of a potential toxicant. The presented workflow addresses many of the methodological challenges current exposomics research is facing and will serve to gain a deeper understanding of the impact of environmental exposures and combinatory toxic effects on human health.


Asunto(s)
Inteligencia Artificial , Metabolómica/métodos , Bases de Datos Genéticas , Genómica , Humanos , Masculino
7.
Anal Chem ; 87(21): 10935-41, 2015 Nov 03.
Artículo en Inglés | MEDLINE | ID: mdl-26434689

RESUMEN

Thermal processes are widely used in small molecule chemical analysis and metabolomics for derivatization, vaporization, chromatography, and ionization, especially in gas chromatography mass spectrometry (GC/MS). In this study the effect of heating was examined on a set of 64 small molecule standards and, separately, on human plasma metabolite extracts. The samples, either derivatized or underivatized, were heated at three different temperatures (60, 100, and 250 °C) at different exposure times (30 s, 60 s, and 300 s). All the samples were analyzed by liquid chromatography coupled to electrospray ionization mass spectrometry (LC/MS) and the data processed by XCMS Online ( xcmsonline.scripps.edu ). The results showed that heating at an elevated temperature of 100 °C had an appreciable effect on both the underivatized and derivatized molecules, and heating at 250 °C created substantial changes in the profile. For example, over 40% of the molecular peaks were altered in the plasma metabolite analysis after heating (250 °C, 300s) with a significant formation of degradation and transformation products. The analysis of 64 small molecule standards validated the temperature-induced changes observed on the plasma metabolites, where most of the small molecules degraded at elevated temperatures even after minimal exposure times (30 s). For example, tri- and diorganophosphates (e.g., adenosine triphosphate and adenosine diphosphate) were readily degraded into a mono-organophosphate (e.g., adenosine monophosphate) during heating. Nucleosides and nucleotides (e.g., inosine and inosine monophosphate) were also found to be transformed into purine derivatives (e.g., hypoxanthine). A newly formed transformation product, oleoyl ethyl amide, was identified in both the underivatized and derivatized forms of the plasma extracts and small molecule standard mixture, and was likely generated from oleic acid. Overall these analyses show that small molecules and metabolites undergo significant time-sensitive alterations when exposed to elevated temperatures, especially those conditions that mimic sample preparation and analysis in GC/MS experiments.


Asunto(s)
Metabolómica , Temperatura , Sangre , Cromatografía Liquida , Cromatografía de Gases y Espectrometría de Masas , Humanos , Masculino , Espectrometría de Masa por Ionización de Electrospray
8.
Bioinformatics ; 31(23): 3721-4, 2015 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-26275895

RESUMEN

MOTIVATION: Metabolite databases provide a unique window into metabolome research allowing the most commonly searched biomarkers to be catalogued. Omic scale metabolite profiling, or metabolomics, is finding increased utility in biomarker discovery largely driven by improvements in analytical technologies and the concurrent developments in bioinformatics. However, the successful translation of biomarkers into clinical or biologically relevant indicators is limited. RESULTS: With the aim of improving the discovery of translatable metabolite biomarkers, we present search analytics for over one million METLIN metabolite database queries. The most common metabolites found in METLIN were cross-correlated against XCMS Online, the widely used cloud-based data processing and pathway analysis platform. Analysis of the METLIN and XCMS common metabolite data has two primary implications: these metabolites, might indicate a conserved metabolic response to stressors and, this data may be used to gauge the relative uniqueness of potential biomarkers. AVAILABILITY AND IMPLEMENTATION: METLIN can be accessed by logging on to: https://metlin.scripps.edu CONTACT: siuzdak@scripps.edu SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online.


Asunto(s)
Metaboloma , Metabolómica , Biomarcadores/metabolismo , Bases de Datos Factuales , Humanos , Espectrometría de Masas
9.
Cell Metab ; 21(6): 891-7, 2015 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-25959674

RESUMEN

Bacterial biofilms in the colon alter the host tissue microenvironment. A role for biofilms in colon cancer metabolism has been suggested but to date has not been evaluated. Using metabolomics, we investigated the metabolic influence that microbial biofilms have on colon tissues and the related occurrence of cancer. Patient-matched colon cancers and histologically normal tissues, with or without biofilms, were examined. We show the upregulation of polyamine metabolites in tissues from cancer hosts with significant enhancement of N(1), N(12)-diacetylspermine in both biofilm-positive cancer and normal tissues. Antibiotic treatment, which cleared biofilms, decreased N(1), N(12)-diacetylspermine levels to those seen in biofilm-negative tissues, indicating that host cancer and bacterial biofilm structures contribute to the polyamine metabolite pool. These results show that colonic mucosal biofilms alter the cancer metabolome to produce a regulator of cellular proliferation and colon cancer growth potentially affecting cancer development and progression.


Asunto(s)
Bacterias/metabolismo , Fenómenos Fisiológicos Bacterianos , Biopelículas , Neoplasias del Colon , Espermina/análogos & derivados , Neoplasias del Colon/metabolismo , Neoplasias del Colon/microbiología , Neoplasias del Colon/patología , Femenino , Humanos , Masculino , Espermina/metabolismo
10.
Chem Biol ; 21(11): 1575-84, 2014 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-25457182

RESUMEN

Historically, studies of brain metabolism have been based on targeted analyses of a limited number of metabolites. Here we present an untargeted mass spectrometry-based metabolomic strategy that has successfully uncovered differences in a broad array of metabolites across anatomical regions of the mouse brain. The NSG immunodeficient mouse model was chosen because of its ability to undergo humanization leading to numerous applications in oncology and infectious disease research. Metabolic phenotyping by hydrophilic interaction liquid chromatography and nanostructure imaging mass spectrometry revealed both water-soluble and lipid metabolite patterns across brain regions. Neurochemical differences in metabolic phenotypes were mainly defined by various phospholipids and several intriguing metabolites including carnosine, cholesterol sulfate, lipoamino acids, uric acid, and sialic acid, whose physiological roles in brain metabolism are poorly understood. This study helps define regional homeostasis for the normal mouse brain to give context to the reaction to pathological events.


Asunto(s)
Encéfalo/metabolismo , Metabolómica , Animales , Encéfalo/anatomía & histología , Mapeo Encefálico , Cromatografía de Afinidad , Cromatografía Líquida de Alta Presión , Análisis por Conglomerados , Interacciones Hidrofóbicas e Hidrofílicas , Subunidad gamma Común de Receptores de Interleucina/deficiencia , Subunidad gamma Común de Receptores de Interleucina/genética , Subunidad gamma Común de Receptores de Interleucina/metabolismo , Ratones , Ratones Endogámicos NOD , Ratones Noqueados , Ratones SCID , Nanoestructuras/química , Resonancia Magnética Nuclear Biomolecular , Espectrometría de Masa por Ionización de Electrospray
11.
Anal Chem ; 86(19): 9358-61, 2014 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-25166490

RESUMEN

The METLIN metabolite database has become one of the most widely used resources in metabolomics for making metabolite identifications. However, METLIN is not designed to identify metabolites that have been isotopically labeled. As a result, unbiasedly tracking the transformation of labeled metabolites with isotope-based metabolomics is a challenge. Here, we introduce a new database, called isoMETLIN (http://isometlin.scripps.edu/), that has been developed specifically to identify metabolites incorporating isotopic labels. isoMETLIN enables users to search all computed isotopologues derived from METLIN on the basis of mass-to-charge values and specified isotopes of interest, such as (13)C or (15)N. Additionally, isoMETLIN contains experimental MS/MS data on hundreds of isotopomers. These data assist in localizing the position of isotopic labels within a metabolite. From these experimental MS/MS isotopomer spectra, precursor atoms can be mapped to fragments. The MS/MS spectra of additional isotopomers can then be computationally generated and included within isoMETLIN. Given that isobaric isotopomers cannot be separated chromatographically or by mass but are likely to occur simultaneously in a biological system, we have also implemented a spectral-mixing function in isoMETLIN. This functionality allows users to combine MS/MS spectra from various isotopomers in different ratios to obtain a theoretical MS/MS spectrum that matches the MS/MS spectrum from a biological sample. Thus, by searching MS and MS/MS experimental data, isoMETLIN facilitates the identification of isotopologues as well as isotopomers from biological samples and provides a platform to drive the next generation of isotope-based metabolomic studies.


Asunto(s)
Bases de Datos Factuales , Metabolómica/métodos , Programas Informáticos , Isótopos de Carbono , Cromatografía Liquida , Isótopos de Nitrógeno , Espectrometría de Masas en Tándem
13.
Nature ; 449(7165): 1033-6, 2007 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-17960240

RESUMEN

The ability of mass spectrometry to generate intact biomolecular ions efficiently in the gas phase has led to its widespread application in metabolomics, proteomics, biological imaging, biomarker discovery and clinical assays (namely neonatal screens). Matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization have been at the forefront of these developments. However, matrix application complicates the use of MALDI for cellular, tissue, biofluid and microarray analysis and can limit the spatial resolution because of the matrix crystal size (typically more than 10 mum), sensitivity and detection of small compounds (less than 500 Da). Secondary-ion mass spectrometry has extremely high lateral resolution (100 nm) and has found biological applications although the energetic desorption/ionization is a limitation owing to molecular fragmentation. Here we introduce nanostructure-initiator mass spectrometry (NIMS), a tool for spatially defined mass analysis. NIMS uses 'initiator' molecules trapped in nanostructured surfaces or 'clathrates' to release and ionize intact molecules adsorbed on the surface. This surface responds to both ion and laser irradiation. The lateral resolution (ion-NIMS about 150 nm), sensitivity, matrix-free and reduced fragmentation of NIMS allows direct characterization of peptide microarrays, direct mass analysis of single cells, tissue imaging, and direct characterization of blood and urine.


Asunto(s)
Espectrometría de Masas/instrumentación , Espectrometría de Masas/métodos , Nanoestructuras , Adsorción , Animales , Análisis Químico de la Sangre , Neoplasias de la Mama/química , Neoplasias de la Mama/patología , Línea Celular Tumoral , Embrión de Mamíferos/química , Iones/química , Rayos Láser , Ratones , Microscopía Electrónica de Rastreo , Nanoestructuras/química , Análisis por Matrices de Proteínas , Sensibilidad y Especificidad , Orina/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...