Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Intervalo de año de publicación
1.
Rev. colomb. cienc. pecu ; 28(2): 144-155, ilus, tab
Artículo en Inglés | LILACS | ID: lil-751720

RESUMEN

Gastroesophageal reflux can be a catastrophic illness in small animals during anesthesia since its complications can cause serious pathologies, such as esophagitis, esophageal stenosis and aspiration pneumonia. With an incidence from 12 to 78.5% in anesthetized dogs, gastroesophageal reflux is normally silent during anesthesia and will be notices only if regurgitation occurs and stomach acid is present in the nasal or oral cavities. In humans, gastroesophageal reflux disease (GERD) is a well-defined pathology where the lower esophageal sphincter has a sustained weakness. However, in dogs, gastroesophageal reflux disease as such is not well established, if at all; it has only been described as gastroesophagic reflux, occurring principally in anesthetized animals. There are several factors influencing the presentation of reflux in anesthetized dogs, which may be inherent to the patient (e.g. age, sex, breed, weight, or body condition), medications used prior to and during anesthesia, type of surgery or position of the animal during surgery. The objective of this review is to discuss a series of conditions that could predispose dogs to gastroesophageal reflux during anesthesia and to assist in the prevention and diagnosis of this condition.


El reflujo gastroesofágico durante la anestesia puede ser una entidad catastrófica en la clínica de pequeñas especies, ya que sus complicaciones derivan en entidades realmente graves como esofagitis, estenosis esofágica y neumonía por aspiración. Con una incidencia del 12 al 78.5% en perros anestesiados, el reflujo gastroesofágico durante la anestesia es generalmente silencioso y sólo se observa cuando existe regurgitación y el reflujo pasa a cavidad oral o nasal. En el humano, la enfermedad por reflujo gastroesofágico (ERGE) es una patología bien definida, donde el esfínter esofágico inferior presenta una debilidad sostenida. Sin embargo, en el perro esta enfermedad como tal no está bien establecida, si acaso se describe el reflujo gastroesofágico, que ocurre principalmente en animales anestesiados. Existen diversos factores que influyen en la presentación del reflujo en los perros anestesiados. Estos pueden ser inherentes al paciente (por ejemplo: edad, sexo, raza, peso o condición corporal), a medicamentos utilizados previamente y durante la anestesia, al tipo de cirugía o a la posición del animal durante la cirugía. El objetivo de esta revisión es discutir una guía de las condiciones que predisponen a la aparición de reflujo gastroesofágico durante la anestesia en perros con el fin de facilitar el diagnóstico y la prevención de esta condición.


O refluxo gastroesofágico durante a anestesia pode ser uma entidade catastrófica na clínica de pequenas espécies, já que suas complicações resultam em entidades realmente graves, como esofagite, estenose esofágica e pneumonia por aspiração. O refluxo gastroesofágico em cães anestesiados é geralmente silencioso, com uma incidência de 12 até 78.5% e só é observada quando há regurgitação e o refluxo passa até a cavidade oral ou nasal. Nos humanos, a doença pelo refluxo gastroesofágico (ERGE) é uma patologia bem definida, onde o esfíncter esofágico inferior apresenta uma debilidade continua. Porém, esta doença em cães não está bem estabelecida, pelo qual só se descreve o refluxo gastroesofágico, que ocorre principalmente em animais anestesiados. Existem diversos fatores que influenciam na apresentação do refluxo em cães anestesiados. Estes podem ser inerentes ao paciente (por exemplo: idade, sexo, raça, peso ou condição corporal), a medicamentos utilizados previamente e durante a anestesia, ao tipo de cirurgia ou a posição do animal durante a cirurgia. O objetivo da revisão foi discutir uma guia das condições que predispõem à aparição de refluxo gastroesofágico durante a anestesia em cães com o fim de facilitar o diagnóstico e a prevenção dessa condição.

2.
Cir Cir ; 81(5): 420-30, 2013.
Artículo en Español | MEDLINE | ID: mdl-25125060

RESUMEN

BACKGROUND: Minimally invasive surgery implementation requires a regulated and orderly learning process. METHODS: Jesús Usón Minimally Invasive Surgery Centre promotes a pyramid training model structured into four levels: training of basic and advanced skills in physical simulator (level 1), training of anatomical protocols and advanced skills with animal models (level 2) training advanced procedural skills with tele-surgical applications (level 3), and training in the operating room (level 4). Training provided at levels 1 and 2 is described and evaluated. RESULTS: 4284 participants have been trained in laparoscopy at our institution. 95.5% surgeons: 49% gastroenterologists, 30% urologists, and 14% gynecologist (14%). 77% of celebrated courses consisted of 20 hours training (8 at level 1 and 12 at level 2). 94.37% of participants considered pyramid model as highly suitable, scoring 9.5 on a scale 1-10 for the model and for the simulation quality. 82.7% perceived the improvement in their laparoscopic skills and 99.56% recommend this training program to other surgeons. DISCUSSION: There are no unified criteria between different training programs but most of them measure laparoscopic skills based on time of execution, quality or mistakes of the exercise, and the student satisfaction test. CONCLUSION: The pyramid training model lead to the acquisition of necessary laparoscopic skills to perform safely advanced minimally invasive techniques.


Antecedentes: la práctica de la cirugía de mínima invasión necesita que el aprendizaje sea estructurado y progresivo. Material y métodos: estudio prospectivo efectuado en el Centro de Cirugía de Mínima Invasión Jesús Usón que propone un modelo de formación piramidal con cuatro niveles: adquisición de habilidades básicas en simulador (nivel 1), desarrollo de técnicas quirúrgicas específicas en modelos animales (nivel 2), telemedicina y telementorización (nivel 3), y aplicación al paciente con supervisión experimentada (nivel 4). Objetivo: describir los niveles 1 y 2 que se practican en el Centro y evaluar la formación impartida. Resultados: 4,284 alumnos han recibido formación en cirugía laparoscópica: 95.5% médicos: cirujanos del aparato digestivo (49%), urólogos (30%) y ginecólogos (14%). En 77% de los cursos celebrados disponen de 20 horas de adiestramiento, 8 en el nivel 1, y 12 en el nivel 2. El 94.37% considera altamente apropiado el modelo de formación piramidal, calificándolo con 9.58 sobre 10 y con 9.5 a la calidad de la simulación. El 82.75% percibe que ha avanzado notablemente en sus destrezas y 99.56% recomendaría a otros cirujanos la realización de actividades en el Centro. Conclusión: el modelo de formación propuesto permite alcanzar las habilidades necesarias para efectuar correctamente procedimientos avanzados en cirugía de mínima invasión.


Asunto(s)
Educación Médica/métodos , Laparoscopía/educación , Modelos Teóricos , Especialidades Quirúrgicas/educación , Animales , Actitud del Personal de Salud , Competencia Clínica , Simulación por Computador , Comportamiento del Consumidor , Curriculum , Diseño de Equipo , Humanos , Laparoscopía/instrumentación , Laparoscopía/métodos , Curva de Aprendizaje , Modelos Anatómicos , Modelos Animales , Médicos/psicología , Desempeño Psicomotor , España , Especialidades Quirúrgicas/métodos , Instrumentos Quirúrgicos , Telemedicina/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA