Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Intervalo de año de publicación
1.
Ear Nose Throat J ; : 1455613231206284, 2023 Oct 16.
Artículo en Inglés | MEDLINE | ID: mdl-37843070

RESUMEN

Objectives: Mucous retention cyst (MRC) is a benign and self-limited lesion that can be caused by many risk factors, including anatomical variations of the sinonasal region. This study aims to investigate the relationship between anatomical variations and the presence of MRC. Materials and Methods: In total, 2109 sinonasal cone beam computed tomography images were evaluated for the presence of MRC, and the sinonasal anatomical regions such as the osteomeatal complex (OMC), infundibulum length, ostium height, the diameter of the ostium, the presence of accessory ostium, concha bullosa, and mucosal thickening of the maxillary sinuses. Shapiro-Wilk normality test, independent sample t-test, and chi-square test were used for statistical analysis, and P < .05 was considered significant. Results: The prevalence of MRC was 119 (5.6%) cases. The average diameter of the ostium in cases with and without MRC was 0.49 ± 0.41 mm and 0.99 ± 0.76 mm, respectively, which showed a significant inverse relationship(P < .001). A significant relationship was found between the septum deviation, the ostium height, the concha bullosa, and the accessory ostium with the presence of MRC (P < .001). Conclusions: Sinonasal anatomical variations such as ostium diameter, ostium height, septal deviation, the presence of accessory ostium, and concha bullosa can cause MRC development, and considering that surgery may be necessary in some cases; this could be of great importance to clinicians and surgeons for treatment and prevention of development or recurrence of these pseudocysts in patients.

2.
Maedica (Bucur) ; 15(2): 224-229, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32952687

RESUMEN

Statement of the problem: The presence of a metal object such as dental implants in the scan field may cause artifacts on the cone-beam computed tomography (CBCT) images, which can reduce the diagnostic quality and accuracy of images. Purpose: The aim of this in vitro study was to compare the severity of implant-induced metal artifacts on CBCT images. Materials and method: To this end, a dry human mandible and a maxilla were selected, then two Roxolid and two Zirconium fixtures with different diameters were placed in the central incisor and first molar sockets and fixed with dental wax. The mandible and maxilla were placed in the simulated phantom for soft tissue, and the occlusal plane was adjusted parallel to the horizon. Images were taken at standard and high resolutions using two CBCT units. The CBCT gray values were measured in three longitudinal sections of the fixture (cervical, middle and apical) and the contrast noise ratio (CNR) was calculated. The CNR values of images were analyzed based on the fixture material, resolution, jaw, unit parameters and fixture size by using the paired t-test and different fixture sections by one-way ANOVA. Results: Depending on the CBCT unit, the CNR values in Roxolid and Zirconium fixtures are completely different. Under higher exposure parameters, the CNR values of the Roxolid and Zirconium fixtures were significantly higher in the maxilla than mandible. However, the fixture size and longitudinal section type did not have a significant effect on the CNR values. Conclusion: In contrast to the fixture material, scanning parameters and jaw type, differences in the size and longitudinal section of the fixtures had no impact on artifact severity.

3.
J Appl Oral Sci ; 27: e20180722, 2019 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-31411266

RESUMEN

OBJECTIVES: Age estimation is one of the most important factors in forensic medicine. Measuring secondary dentin deposition using cone-beam computed tomography images is an easy and noninvasive method. The aim of this study was to evaluate cone-beam computed tomography images as a reliable method to estimate chronological age by pulp/teeth ratio in anterior teeth in Iranian population. METHODOLOGY: A total of 649 CBCT images from 377 Iranian patients aged between 20 and 69 years were evaluated. Pulp/teeth ratio (PTR) in maxillary and mandibular canine and central incisor teeth was measured in the axial and sagittal sections using OnDemand 3D Dental software. The Pearson correlation coefficient was determined to evaluate the correlation between the variables. Linear regression analysis, as well as age estimation formula, was used for each tooth separately. RESULTS: The regression analyses indicated that maxillary central incisors were more reliable for age estimation (R2=0.586 and standard error of estimate=7.045) compared with the other anterior teeth studied. Maxillary canine teeth had the lowest predictive power (R2=0.392 and standard error of estimate=8.387). Also, comparison of the axial and sagittal sections showed that the axial sections had a higher predictive power. (R2=0.48 for axial plans and R2=0.328 for sagittal plans). CONCLUSION: The use of cone-beam computed tomography in age estimation by pulp/teeth ratio of anterior teeth is useful and a reliable method for age estimation in Iranian population.


Asunto(s)
Determinación de la Edad por los Dientes/métodos , Tomografía Computarizada de Haz Cónico/métodos , Pulpa Dental/anatomía & histología , Pulpa Dental/diagnóstico por imagen , Diente/anatomía & histología , Diente/diagnóstico por imagen , Adulto , Factores de Edad , Anciano , Diente Canino/anatomía & histología , Diente Canino/diagnóstico por imagen , Femenino , Humanos , Imagenología Tridimensional , Incisivo/anatomía & histología , Incisivo/diagnóstico por imagen , Modelos Lineales , Masculino , Persona de Mediana Edad , Tamaño de los Órganos , Valores de Referencia , Reproducibilidad de los Resultados , Factores Sexuales , Adulto Joven
4.
J. appl. oral sci ; 27: e20180722, 2019. tab, graf
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-1012521

RESUMEN

Abstract Objectives Age estimation is one of the most important factors in forensic medicine. Measuring secondary dentin deposition using cone-beam computed tomography images is an easy and noninvasive method. The aim of this study was to evaluate cone-beam computed tomography images as a reliable method to estimate chronological age by pulp/teeth ratio in anterior teeth in Iranian population. Methodology A total of 649 CBCT images from 377 Iranian patients aged between 20 and 69 years were evaluated. Pulp/teeth ratio (PTR) in maxillary and mandibular canine and central incisor teeth was measured in the axial and sagittal sections using OnDemand 3D Dental software. The Pearson correlation coefficient was determined to evaluate the correlation between the variables. Linear regression analysis, as well as age estimation formula, was used for each tooth separately. Results The regression analyses indicated that maxillary central incisors were more reliable for age estimation (R2=0.586 and standard error of estimate=7.045) compared with the other anterior teeth studied. Maxillary canine teeth had the lowest predictive power (R2=0.392 and standard error of estimate=8.387). Also, comparison of the axial and sagittal sections showed that the axial sections had a higher predictive power. (R2=0.48 for axial plans and R2=0.328 for sagittal plans) Conclusion The use of cone-beam computed tomography in age estimation by pulp/teeth ratio of anterior teeth is useful and a reliable method for age estimation in Iranian population.


Asunto(s)
Humanos , Masculino , Femenino , Adolescente , Anciano , Adulto Joven , Diente/anatomía & histología , Diente/diagnóstico por imagen , Determinación de la Edad por los Dientes/métodos , Pulpa Dental/anatomía & histología , Pulpa Dental/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico/métodos , Tamaño de los Órganos , Valores de Referencia , Modelos Lineales , Factores Sexuales , Reproducibilidad de los Resultados , Factores de Edad , Diente Canino/anatomía & histología , Diente Canino/diagnóstico por imagen , Imagenología Tridimensional , Incisivo/anatomía & histología , Incisivo/diagnóstico por imagen , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...