Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Ann Intensive Care ; 14(1): 49, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38558268

RESUMEN

BACKGROUND: Several studies have validated capillary refill time (CRT) as a marker of tissue hypoperfusion, and recent guidelines recommend CRT monitoring during septic shock resuscitation. Therefore, it is relevant to further explore its kinetics of response to short-term hemodynamic interventions with fluids or vasopressors. A couple of previous studies explored the impact of a fluid bolus on CRT, but little is known about the impact of norepinephrine on CRT when aiming at a higher mean arterial pressure (MAP) target in septic shock. We designed this observational study to further evaluate the effect of a fluid challenge (FC) and a vasopressor test (VPT) on CRT in septic shock patients with abnormal CRT after initial resuscitation. Our purpose was to determine the effects of a FC in fluid-responsive patients, and of a VPT aimed at a higher MAP target in chronically hypertensive fluid-unresponsive patients on the direction and magnitude of CRT response. METHODS: Thirty-four septic shock patients were included. Fluid responsiveness was assessed at baseline, and a FC (500 ml/30 mins) was administered in 9 fluid-responsive patients. A VPT was performed in 25 patients by increasing norepinephrine dose to reach a MAP to 80-85 mmHg for 30 min. Patients shared a multimodal perfusion and hemodynamic monitoring protocol with assessments at at least two time-points (baseline, and at the end of interventions). RESULTS: CRT decreased significantly with both tests (from 5 [3.5-7.6] to 4 [2.4-5.1] sec, p = 0.008 after the FC; and from 4.0 [3.3-5.6] to 3 [2.6 -5] sec, p = 0.03 after the VPT. A CRT-response was observed in 7/9 patients after the FC, and in 14/25 pts after the VPT, but CRT deteriorated in 4 patients on this latter group, all of them receiving a concomitant low-dose vasopressin. CONCLUSIONS: Our findings support that fluid boluses may improve CRT or produce neutral effects in fluid-responsive septic shock patients with persistent hypoperfusion. Conversely, raising NE doses to target a higher MAP in previously hypertensive patients elicits a more heterogeneous response, improving CRT in the majority, but deteriorating skin perfusion in some patients, a fact that deserves further research.

2.
Crit Care ; 28(1): 52, 2024 02 19.
Artículo en Inglés | MEDLINE | ID: mdl-38374167

RESUMEN

BACKGROUND: Current recommendations support guiding fluid resuscitation through the assessment of fluid responsiveness. Recently, the concept of fluid tolerance and the prevention of venous congestion (VC) have emerged as relevant aspects to be considered to avoid potentially deleterious side effects of fluid resuscitation. However, there is paucity of data on the relationship of fluid responsiveness and VC. This study aims to compare the prevalence of venous congestion in fluid responsive and fluid unresponsive critically ill patients after intensive care (ICU) admission. METHODS: Multicenter, prospective cross-sectional observational study conducted in three medical-surgical ICUs in Chile. Consecutive mechanically ventilated patients that required vasopressors and admitted < 24 h to ICU were included between November 2022 and June 2023. Patients were assessed simultaneously for fluid responsiveness and VC at a single timepoint. Fluid responsiveness status, VC signals such as central venous pressure, estimation of left ventricular filling pressures, lung, and abdominal ultrasound congestion indexes and relevant clinical data were collected. RESULTS: Ninety patients were included. Median age was 63 [45-71] years old, and median SOFA score was 9 [7-11]. Thirty-eight percent of the patients were fluid responsive (FR+), while 62% were fluid unresponsive (FR-). The most prevalent diagnosis was sepsis (41%) followed by respiratory failure (22%). The prevalence of at least one VC signal was not significantly different between FR+ and FR- groups (53% vs. 57%, p = 0.69), as well as the proportion of patients with 2 or 3 VC signals (15% vs. 21%, p = 0.4). We found no association between fluid balance, CRT status, or diagnostic group and the presence of VC signals. CONCLUSIONS: Venous congestion signals were prevalent in both fluid responsive and unresponsive critically ill patients. The presence of venous congestion was not associated with fluid balance or diagnostic group. Further studies should assess the clinical relevance of these results and their potential impact on resuscitation and monitoring practices.


Asunto(s)
Hiperemia , Sepsis , Humanos , Persona de Mediana Edad , Anciano , Enfermedad Crítica/epidemiología , Enfermedad Crítica/terapia , Estudios Prospectivos , Estudios Transversales , Hiperemia/complicaciones , Sepsis/complicaciones , Fluidoterapia/métodos
3.
Ann Intensive Care ; 13(1): 104, 2023 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-37851284

RESUMEN

BACKGROUND: Prophylactic high-flow nasal cannula (HFNC) oxygen therapy can decrease the risk of extubation failure. It is frequently used in the postextubation phase alone or in combination with noninvasive ventilation. However, its physiological effects in this setting have not been thoroughly investigated. The aim of this study was to determine comprehensively the effects of HFNC applied after extubation on respiratory effort, diaphragm activity, gas exchange, ventilation distribution, and cardiovascular biomarkers. METHODS: This was a prospective randomized crossover physiological study in critically ill patients comparing 1 h of HFNC versus 1 h of standard oxygen after extubation. The main inclusion criteria were mechanical ventilation for at least 48 h due to acute respiratory failure, and extubation after a successful spontaneous breathing trial (SBT). We measured respiratory effort through esophageal/transdiaphragmatic pressures, and diaphragm electrical activity (ΔEAdi). Lung volumes and ventilation distribution were estimated by electrical impedance tomography. Arterial and central venous blood gases were analyzed, as well as cardiac stress biomarkers. RESULTS: We enrolled 22 patients (age 59 ± 17 years; 9 women) who had been intubated for 8 ± 6 days before extubation. Respiratory effort was significantly lower with HFNC than with standard oxygen therapy, as evidenced by esophageal pressure swings (5.3 [4.2-7.1] vs. 7.2 [5.6-10.3] cmH2O; p < 0.001), pressure-time product (85 [67-140] vs. 156 [114-238] cmH2O*s/min; p < 0.001) and ΔEAdi (10 [7-13] vs. 14 [9-16] µV; p = 0.022). In addition, HFNC induced increases in end-expiratory lung volume and PaO2/FiO2 ratio, decreases in respiratory rate and ventilatory ratio, while no changes were observed in systemic hemodynamics, Troponin T, or in amino-terminal pro-B-type natriuretic peptide. CONCLUSIONS: Prophylactic application of HFNC after extubation provides substantial respiratory support and unloads respiratory muscles. Trial registration January 15, 2021. NCT04711759.

4.
J Clin Monit Comput ; 37(3): 839-845, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36495360

RESUMEN

Capillary refill time (CRT), a costless and widely available tool, has emerged as a promising target to guide septic shock resuscitation. However, it has yet to gain universal acceptance due to its potential inter-observer variability. Standardization of CRT assessment may minimize this problem, but few studies have compared this approach with techniques that directly assess skin blood flow (SBF). Our objective was to determine if an abnormal CRT is associated with impaired SBF and microvascular reactivity in early septic shock patients. Twelve septic shock patients were subjected to multimodal perfusion and hemodynamic monitoring for 24 h. Three time-points (0, 1, and 24 h) were registered for each patient. SBF was measured by laser doppler. We performed a baseline SBF measurement and two microvascular reactivity tests: one with a thermal challenge at 44 °C and other with a vascular occlusion test. Ten healthy volunteers were evaluated to obtain reference values. The patients (median age 70 years) exhibited a 28-day mortality of 50%. Baseline CRT was 3.3 [2.7-7.3] seconds. In pooled data analysis, abnormal CRT presented a significantly lower SBF when compared to normal CRT [44 (13.3-80.3) vs 193.2 (99.4-285) APU, p = 0.0001]. CRT was strongly associated with SBF (R2 0.76, p < 0.0001). An abnormal CRT also was associated with impaired thermal challenge and vascular occlusion tests. Abnormal CRT values observed during early septic shock resuscitation are associated with impaired skin blood flow, and abnormal skin microvascular reactivity. Future studies should confirm these results.


Asunto(s)
Choque Séptico , Humanos , Anciano , Microcirculación , Proyectos Piloto , Hemodinámica/fisiología , Resucitación/métodos
5.
J Crit Care ; 72: 154166, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36244256

RESUMEN

PURPOSE: To evaluate cardiac function in mechanically ventilated patients with COVID-19. MATERIALS AND METHODS: Prospective, cross-sectional multicenter study in four university-affiliated hospitals in Chile. All consecutive patients with COVID-19 ARDS requiring mechanical ventilation admitted between April and July 2020 were included. We performed systematic transthoracic echocardiography assessing right and left ventricular function within 24 h of intubation. RESULTS: 140 patients aged 57 ± 11, 29% female were included. Cardiac output was 5.1 L/min [IQR 4.5-6.2] and 86% of the patients required norepinephrine. ICU mortality was 29% (40 patients). Fifty-four patients (39%) exhibited right ventricle dilation out of whom 20 patients (14%) exhibited acute cor pulmonale (ACP). Eight out of the twenty patients with ACP exhibited pulmonary embolism (40%). Thirteen patients (9%) exhibited left ventricular systolic dysfunction (ejection fraction <45%). In the multivariate analysis acute cor pulmonale and PaO2/FiO2 ratio were independent predictors of ICU mortality. CONCLUSIONS: Right ventricular dilation is highly prevalent in mechanically ventilated patients with COVID-19 ARDS. Acute cor pulmonale was associated with reduced pulmonary function and, in only 40% of patients, with co-existing pulmonary embolism. Acute cor pulmonale is an independent risk factor for ICU mortality.


Asunto(s)
COVID-19 , Insuficiencia Cardíaca , Embolia Pulmonar , Enfermedad Cardiopulmonar , Síndrome de Dificultad Respiratoria , Humanos , Femenino , Masculino , Enfermedad Cardiopulmonar/etiología , Respiración Artificial/efectos adversos , Enfermedad Crítica , Estudios Transversales , Estudios Prospectivos , Embolia Pulmonar/complicaciones , Insuficiencia Cardíaca/complicaciones , Síndrome de Dificultad Respiratoria/terapia
6.
J Ultrasound ; 25(4): 855-859, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35229275

RESUMEN

PURPOSE: Critical care echocardiography is a fundamental tool in the hemodynamic evaluation of critically ill patients and prone position ventilation might limit its application. We aim to evaluate the feasibility of transthoracic echocardiography to assess different measurements performed in prone vs supine position in patients during COVID-19 pandemic to answer our research question: What is the feasibility of classic echocardiographic measurements in COVID-19 patients in prone position ventilation? METHODS: Patients with covid-19 admitted to ICUs in four academic hospitals with respiratory failure and on mechanical ventilation were evaluated with critical care echocardiography. The first ultrasound assessment was compared between prone and supine patients recording feasibility of several echocardiographic measurements, using Fisher's exact test complementing with Crombach's Alpha. RESULTS: 139 patients were included. Sixty-eight (49%) were evaluated in prone position and seventy one (51%) in supine position. Most variables were highly feasible, left ventricular volumes and ejection fraction were more possible to obtain in prone position, while cardiac output was in supine position. Tricuspid regurgitation was the least feasible overall measurement. CONCLUSION: Prone position ultrasound achieved a high feasibility of measurements compared with supine ultrasound in critically ill patients with COVID-19 respiratory failure and on mechanical ventilation. REGISTRATION: Post hoc analysis of Echo-COVID study (NTC04628195, registered November 13, 2020, retrospectively registered).


Asunto(s)
COVID-19 , Insuficiencia Respiratoria , Humanos , Posición Prona , Estudios de Factibilidad , Enfermedad Crítica , Pandemias , Cuidados Críticos , Ecocardiografía
7.
Ann Intensive Care ; 10(1): 150, 2020 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-33140173

RESUMEN

BACKGROUND: Persistent hyperlactatemia has been considered as a signal of tissue hypoperfusion in septic shock patients, but multiple non-hypoperfusion-related pathogenic mechanisms could be involved. Therefore, pursuing lactate normalization may lead to the risk of fluid overload. Peripheral perfusion, assessed by the capillary refill time (CRT), could be an effective alternative resuscitation target as recently demonstrated by the ANDROMEDA-SHOCK trial. We designed the present randomized controlled trial to address the impact of a CRT-targeted (CRT-T) vs. a lactate-targeted (LAC-T) fluid resuscitation strategy on fluid balances within 24 h of septic shock diagnosis. In addition, we compared the effects of both strategies on organ dysfunction, regional and microcirculatory flow, and tissue hypoxia surrogates. RESULTS: Forty-two fluid-responsive septic shock patients were randomized into CRT-T or LAC-T groups. Fluids were administered until target achievement during the 6 h intervention period, or until safety criteria were met. CRT-T was aimed at CRT normalization (≤ 3 s), whereas in LAC-T the goal was lactate normalization (≤ 2 mmol/L) or a 20% decrease every 2 h. Multimodal perfusion monitoring included sublingual microcirculatory assessment; plasma-disappearance rate of indocyanine green; muscle oxygen saturation; central venous-arterial pCO2 gradient/ arterial-venous O2 content difference ratio; and lactate/pyruvate ratio. There was no difference between CRT-T vs. LAC-T in 6 h-fluid boluses (875 [375-2625] vs. 1500 [1000-2000], p = 0.3), or balances (982[249-2833] vs. 15,800 [740-6587, p = 0.2]). CRT-T was associated with a higher achievement of the predefined perfusion target (62 vs. 24, p = 0.03). No significant differences in perfusion-related variables or hypoxia surrogates were observed. CONCLUSIONS: CRT-targeted fluid resuscitation was not superior to a lactate-targeted one on fluid administration or balances. However, it was associated with comparable effects on regional and microcirculatory flow parameters and hypoxia surrogates, and a faster achievement of the predefined resuscitation target. Our data suggest that stopping fluids in patients with CRT ≤ 3 s appears as safe in terms of tissue perfusion. Clinical Trials: ClinicalTrials.gov Identifier: NCT03762005 (Retrospectively registered on December 3rd 2018).

8.
Anesthesiology ; 133(5): 1106-1117, 2020 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-32898217

RESUMEN

BACKGROUND: A lung rest strategy is recommended during extracorporeal membrane oxygenation in severe acute respiratory distress syndrome (ARDS). However, spontaneous breathing modes are frequently used in this context. The impact of this approach may depend on the intensity of breathing efforts. The authors aimed to determine whether a low spontaneous breathing effort strategy increases lung injury, compared to a controlled near-apneic ventilation, in a porcine severe ARDS model assisted by extracorporeal membrane oxygenation. METHODS: Twelve female pigs were subjected to lung injury by repeated lavages, followed by 2-h injurious ventilation. Thereafter, animals were connected to venovenous extracorporeal membrane oxygenation and during the first 3 h, ventilated with near-apneic ventilation (positive end-expiratory pressure, 10 cm H2O; driving pressure, 10 cm H2O; respiratory rate, 5/min). Then, animals were allocated into (1) near-apneic ventilation, which continued with the previous ventilatory settings; and (2) spontaneous breathing: neuromuscular blockers were stopped, sweep gas flow was decreased until regaining spontaneous efforts, and ventilation was switched to pressure support mode (pressure support, 10 cm H2O; positive end-expiratory pressure, 10 cm H2O). In both groups, sweep gas flow was adjusted to keep Paco2 between 30 and 50 mmHg. Respiratory and hemodynamic as well as electric impedance tomography data were collected. After 24 h, animals were euthanized and lungs extracted for histologic tissue analysis. RESULTS: Compared to near-apneic group, the spontaneous breathing group exhibited a higher respiratory rate (52 ± 17 vs. 5 ± 0 breaths/min; mean difference, 47; 95% CI, 34 to 59; P < 0.001), but similar tidal volume (2.3 ± 0.8 vs. 2.8 ± 0.4 ml/kg; mean difference, 0.6; 95% CI, -0.4 to 1.4; P = 0.983). Extracorporeal membrane oxygenation settings and gas exchange were similar between groups. Dorsal ventilation was higher in the spontaneous breathing group. No differences were observed regarding histologic lung injury. CONCLUSIONS: In an animal model of severe ARDS supported with extracorporeal membrane oxygenation, spontaneous breathing characterized by low-intensity efforts, high respiratory rates, and very low tidal volumes did not result in increased lung injury compared to controlled near-apneic ventilation.


Asunto(s)
Modelos Animales de Enfermedad , Oxigenación por Membrana Extracorpórea/métodos , Síndrome de Dificultad Respiratoria/fisiopatología , Síndrome de Dificultad Respiratoria/terapia , Mecánica Respiratoria/fisiología , Índice de Severidad de la Enfermedad , Animales , Femenino , Porcinos
9.
Ann Intensive Care ; 10(1): 114, 2020 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-32845407

RESUMEN

BACKGROUND: Capillary refill time (CRT) may improve more rapidly than lactate in response to increments in systemic flow. Therefore, it can be assessed more frequently during septic shock (SS) resuscitation. Hyperlactatemia, in contrast, exhibits a slower recovery in SS survivors, probably explained by the delayed resolution of non-hypoperfusion-related sources. Thus, targeting lactate normalization may be associated with impaired outcomes. The ANDROMEDA-SHOCK trial compared CRT- versus lactate-targeted resuscitation in early SS. CRT-targeted resuscitation associated with lower mortality and organ dysfunction; mechanisms were not investigated. CRT was assessed every 30 min and lactate every 2 h during the 8-h intervention period, allowing a first comparison between groups at 2 h (T2). Our primary aim was to determine if SS patients evolving with normal CRT at T2 after randomization (T0) exhibited a higher mortality and organ dysfunction when allocated to the LT arm than when randomized to the CRT arm. Our secondary aim was to determine if those patients with normal CRT at T2 had received more therapeutic interventions when randomized to the LT arm. To address these issues, we performed a post hoc analysis of the ANDROMEDA-SHOCK dataset. RESULTS: Patients randomized to the lactate arm at T0, evolving with normal CRT at T2 exhibited significantly higher mortality than patients with normal CRT at T2 initially allocated to CRT (40 vs 23%, p = 0.009). These results replicated at T8 and T24. LT arm received significantly more resuscitative interventions (fluid boluses: 1000[500-2000] vs. 500[0-1500], p = 0.004; norepinephrine test in previously hypertensive patients: 43 (35) vs. 19 (19), p = 0.001; and inodilators: 16 (13) vs. 3 (3), p = 0.003). A multivariate logistic regression of patients with normal CRT at T2, including APACHE-II, baseline lactate, cumulative fluids administered since emergency admission, source of infection, and randomization group) confirmed that allocation to LT group was a statistically significant determinant of 28-day mortality (OR 3.3; 95%CI[1.5-7.1]); p = 0.003). CONCLUSIONS: Septic shock patients with normal CRT at baseline received more therapeutic interventions and presented more organ dysfunction when allocated to the lactate group. This could associate with worse outcomes.

10.
Ann Transl Med ; 8(12): 784, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32647709

RESUMEN

BACKGROUND: Assessment of tissue hypoxia at the bedside has yet to be translated into daily clinical practice in septic shock patients. Perfusion markers are surrogates of deeper physiological phenomena. Lactate-to-pyruvate ratio (LPR) and the ratio between veno-arterial PCO2 difference and Ca-vO2 (ΔPCO2/Ca-vO2) have been proposed as markers of tissue hypoxia, but they have not been compared in the clinical scenario. We studied acute septic shock patients under resuscitation. We wanted to evaluate the relationship of these hypoxia markers with clinical and biochemical markers of hypoperfusion during septic shock resuscitation. METHODS: Secondary analysis of a randomized controlled trial. Septic shock patients were randomized to fluid resuscitation directed to normalization of capillary refill time (CRT) versus normalization or significant lowering of lactate. Multimodal assessment of perfusion was performed at 0, 2, 6 and 24 hours, and included macrohemodynamic and metabolic perfusion variables, CRT, regional flow and hypoxia markers. Patients who attained their pre-specified endpoint at 2-hours were compared to those who did not. RESULTS: Forty-two patients were recruited, median APACHE-II score was 23 [15-31] and 28-day mortality 23%. LPR and ΔPCO2/Ca-vO2 ratio did not correlate during early resuscitation (0-2 h) and the whole study period (24-hours). ΔPCO2/Ca-vO2 ratio derangements were more prevalent than LPR ones, either in the whole cohort (52% vs. 23%), and in association with other perfusion abnormalities. In patients who reached their resuscitation endpoints, the proportion of patients with altered ΔPCO2/Ca-vO2 ratio decreased significantly (66% to 33%, P=0.045), while LPR did not (14% vs. 25%, P=0.34). CONCLUSIONS: Hypoxia markers did not exhibit correlation during resuscitation in septic shock patients. They probably interrogate different pathophysiological processes and mechanisms of dysoxia during early septic shock. Future studies should better elucidate the interaction and clinical role of hypoxia markers during septic shock resuscitation.

11.
PLoS One ; 14(12): e0225181, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31805071

RESUMEN

BACKGROUND: The spontaneous breathing trial (SBT) assesses the risk of weaning failure by evaluating some physiological responses to the massive venous return increase imposed by discontinuing positive pressure ventilation. This trial can be very demanding for some critically ill patients, inducing excessive physical and cardiovascular stress, including muscle fatigue, heart ischemia and eventually cardiac dysfunction. Extubation failure with emergency reintubation is a serious adverse consequence of a failed weaning process. Some data suggest that as many as 50% of patients that fail weaning do so because of cardiac dysfunction. Unfortunately, monitoring cardiovascular function at the time of the SBT is complex. The aim of our study was to explore if central venous pressure (CVP) changes were related to weaning failure after starting an SBT. We hypothesized that an early rise on CVP could signal a cardiac failure when handling a massive increase on venous return following a discontinuation of positive pressure ventilation. This CVP rise could identify a subset of patients at high risk for extubation failure. METHODS: Two-hundred and four mechanically ventilated patients in whom an SBT was decided were subjected to a monitoring protocol that included blinded assessment of CVP at baseline, and at 2 minutes after starting the trial (CVP-test). Weaning failure was defined as reintubation within 48-hours following extubation. Comparisons between two parametric or non-parametric variables were performed with student T test or Mann Whitney U test, respectively. A logistic multivariate regression was performed to determine the predictive value on extubation failure of usual clinical variables and CVP at 2-min after starting the SBT. RESULTS: One-hundred and sixty-five patients were extubated after the SBT, 11 of whom were reintubated within 48h. Absolute CVP values at 2-minutes, and the change from baseline (dCVP) were significantly higher in patients with extubation failure as compared to those successfully weaned. dCVP was an early predictor for reintubation (OR: 1.70 [1.31,2.19], p<0.001). CONCLUSIONS: An early rise in CVP after starting an SBT was associated with an increased risk of extubation failure. This might represent a warning signal not captured by usual SBT monitoring and could have relevant clinical implications.


Asunto(s)
Presión Venosa Central/fisiología , Enfermedad Crítica , Desconexión del Ventilador/métodos , Adulto , Anciano , Extubación Traqueal/métodos , Femenino , Humanos , Unidades de Cuidados Intensivos , Masculino , Persona de Mediana Edad , Medición de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...