Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 89
Filtrar
1.
J Cardiovasc Surg (Torino) ; 55(6): 831-9, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25268074

RESUMEN

AIM: Autologous pericardium annuloplasty (APA) is an alternative to prosthetic ring implantation for mitral valve (MV) repair, avoiding the use of foreign material and preserving the mitral annulus' physiological motion. However, data on durability are questionable. Therefore, we analyzed long-term outcomes of treating degenerative mitral regurgitation (MR) with APA. METHODS: Four hundred ninety patients (mean age, 54.3±11.3 years, [15-77 years]; N.=360 men [74.1%]) who had undergone APA and neochordae implantation between July 1988 and December 2006 were retrospectively studied. RESULTS: MR was purely degenerative in 434 (89.3%) patients; endocarditis was present in 44 (9.1%) patients; an anterior, posterior, or bileaflet prolapse was present in 32 (6.6%), 241 (49.6%), and 213 (43.8%) patients, respectively. Clinical follow-up was 100% complete at a median of 6.5 years (5th percentile, 0.9; 95th percentile, 14.9) with an echocardiographic study in 92% of patients. In-hospital mortality was 1% (5 deaths); overall and late cardiac mortality were 7.6% and 3.9% (37 and 19 deaths), respectively. Kaplan-Meier curves for overall survival, late cardiac survival, and freedom from reoperation at 15 years (20 cases) were 86% (95%CI 80-91), 93% (95%CI 88-96), and 93% (95%CI 88-96), respectively. At 15 years, freedom from recurrent MR (28 patients) and endocarditis (6 events) were 86% (95%CI 76-91) and 97% (95%CI 92-99). Dehiscence, significant calcification of APA, and hemolysis never occurred. At reoperations, annular pericardium appeared covered by a smooth layer of tissue. CONCLUSION: APA is feasible, safe, and cost-effective, providing long-term durability, high survival, and a low rate of valve-related complications.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Anuloplastia de la Válvula Mitral/métodos , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Pericardio/trasplante , Adolescente , Adulto , Anciano , Supervivencia sin Enfermedad , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Mortalidad Hospitalaria , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Válvula Mitral/fisiopatología , Anuloplastia de la Válvula Mitral/efectos adversos , Anuloplastia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/cirugía , Recurrencia , Reoperación , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Trasplante Autólogo , Resultado del Tratamiento , Adulto Joven
2.
Perfusion ; 27(6): 486-92, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22798170

RESUMEN

This extension study investigated the association between preoperative cerebral blood flow (CBF) velocity and postoperative cognitive decline (POCD) at a three-month follow-up in patients who underwent cardiac surgery. Continuous transcranial Doppler ultrasound on both middle cerebral arteries (MCAs) was used preoperatively in 31 right-handed cardiac surgery patients at rest. Each patient performed a neuropsychological evaluation to assess cognitive performance before surgery, at discharge and at three-month follow-up. Patients with POCD at the three-month follow-up had a marginally significantly lower preoperative CBF velocity in the left MCA than patients without POCD. Moreover, the group with POCD had a significantly lower CBF velocity in the left than in the right MCA, whereas no difference between the left and right CBF velocity was found in the group without POCD. These preliminary findings suggest that reduced preoperative CBF velocity in the left MCA may represent an independent risk factor for cognitive decline in patients three months after surgery.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/efectos adversos , Circulación Cerebrovascular/fisiología , Trastornos del Conocimiento/etiología , Velocidad del Flujo Sanguíneo , Procedimientos Quirúrgicos Cardíacos/métodos , Trastornos del Conocimiento/diagnóstico por imagen , Trastornos del Conocimiento/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pruebas Neuropsicológicas , Periodo Posoperatorio , Factores de Riesgo , Ultrasonografía Doppler Transcraneal/métodos
3.
Perfusion ; 27(3): 199-206, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22337762

RESUMEN

Our objective was to determine the role of asymmetry and the nature of microembolization on postoperative cognitive decline in patients who had undergone heart valve surgery. Continuous transcranial Doppler ultrasound was intraoperatively used for both middle cerebral arteries in 13 right-handed heart valve surgery patients to detect microembolization. The Trail Making Test A and B, Memory with 10/30 s interference, the Digit Span Test and Phonemic Fluency were performed preoperatively, at discharge and three months after surgery. Our data suggest that early and late postoperative psychomotor and executive functions may be sensitive to microemboli in the left, but not in the right middle cerebral artery. Moreover, solid and gaseous microemboli are both similarly associated with early postoperative cognitive decline while, surprisingly, late postoperative cognitive decline is more likely to be associated with gaseous than solid microemboli.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/efectos adversos , Embolia Intracraneal/fisiopatología , Trastornos de la Memoria/fisiopatología , Complicaciones Posoperatorias/fisiopatología , Anciano , Femenino , Humanos , Embolia Intracraneal/diagnóstico por imagen , Embolia Intracraneal/etiología , Masculino , Trastornos de la Memoria/diagnóstico por imagen , Trastornos de la Memoria/etiología , Persona de Mediana Edad , Arteria Cerebral Media/diagnóstico por imagen , Arteria Cerebral Media/fisiopatología , Proyectos Piloto , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/etiología , Ultrasonografía Doppler Transcraneal/métodos
6.
Europace ; 5(2): 133-8, 2003 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-12633636

RESUMEN

UNLABELLED: Supraventricular arrhythmias are often observed in patients before and after atrial septal defect repair. Although several papers report different incidences of sustained supraventricular arrhythmias, postoperative 'incisional' macroreentrant tachycardias have not been systematically investigated. METHODS: We reviewed 136 consecutive patients (79 female, 57 male, mean age 36.8+/-17.8 years) who underwent atrial septal defect repair at our institutions between January 1990 and January 1999. Coexisting valve disease requiring surgical intervention was noted in 13 patients (9.5%). The mean follow-up period was 78.8+/-30.1 months. RESULTS: Sustained supraventricular arrhythmias occurred in 12 patients (8.8%) before surgery (atrial fibrillation in 11 patients). Using multivariate analysis the occurrence of arrhythmia significantly correlated with the presence of coexisting heart disease (P< 0.001) and age at surgery (P=0.011) After surgery sustained supraventricular arrhythmias were recorded in 16 patients (11.7%). Eleven of them had atrial fibrillation, permanent in 8 cases, 4 'incisional' macroreentrant atrial tachycardia and 1 atrioventricular re-entry tachycardia. There was a significant correlation between pre and postoperative arrhythmia (P< 0.001). Two of the 4 patients with macroreentrant atrial tachycardia underwent successful radiofrequency catheter ablation, whereas the arrhythmia was controlled medically in the remaining 2 patients. CONCLUSIONS: Atrial fibrillation remains the most frequent form of arrhythmia before and after surgical closure of atrial septal defects in adulthood, and relates to age at the time of repair and coexisting heart disease. Incisional macroreentrant atrial tachycardia is an identifiable, albeit less common, form of tachycardia, which can be treated by transcatheter ablation.


Asunto(s)
Defectos del Tabique Interatrial/fisiopatología , Defectos del Tabique Interatrial/cirugía , Taquicardia Supraventricular/fisiopatología , Taquicardia Supraventricular/cirugía , Adolescente , Adulto , Factores de Edad , Anciano , Electrocardiografía , Femenino , Estudios de Seguimiento , Defectos del Tabique Interatrial/complicaciones , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Factores de Riesgo , Taquicardia Supraventricular/etiología , Factores de Tiempo , Insuficiencia del Tratamiento
7.
Ann Thorac Surg ; 72(3): S1059-64, 2001 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-11565727

RESUMEN

BACKGROUND: The aim of this study was to evaluate the midterm results of a modified button-Bentall operation (modified-bB) specifically designed to incorporate any type of prosthetic valve in composite conduit aortic root replacement. METHODS: Between 1991 and 2000, a total of 135 patients underwent modified-bB for annuloaortic ectasia (74 patients), type A dissection (31), or aortic aneurysm without dissection (30). Of these, 34 were emergencies (25.2%). A total of 50 bioprostheses (study group 1) and 85 bileaflet mechanical prostheses (study group 2) were implanted. Group 1 mean age was 66.9 +/- 7.4 years versus 51.5 +/- 12.1 years in group 2 (p < 0.001). Composite-conduit creation occurred during proximal suture line construction as a single-step maneuver. Interrupted extracardiac polyester mattress sutures sequentially entered the aortic annulus, the prosthetic valve ring, and the vascular graft 7 mm from its free edge (miniskirt). Running monofilament suture line secured proximal hemostasis, buttressing aortic remnants and graft edge. Coronary reimplantation was accomplished in all cases by the button technique. Concomitant procedures were performed in 51 patients (37.8%). RESULTS: The 30-day mortality was 5.18% (7/135 patients). Eight patients (5.9%) required revision for proximal (1 patient), coronary button (3), or distal (4) anastomosis leakage. Three patients (2.2%) perioperatively developed nonfatal inferior myocardial infarction. Kaplan-Meier 9-year survival is 91.8% +/- 0.026 SE with 88.1% (95% confidence limits 71.7% to 95.5%) reoperation freedom. According to the Cox proportional hazard method, stratification of the risk for death according to prosthesis type indicates previous operation (p = 0.001) and emergency (p = 0.0465) as independent predictors of hospital mortality. Associated procedures to modified-bB increased risk of reoperation (p = 0.031). CONCLUSIONS: Modified-bB was associated with low mortality, excellent midterm survival, and freedom from reoperation. Absence of valve-to-graft tapering, reduced coronary button anastomosis tension, and prosthesis selection according to patient profile, are apparent advantages of modified-bB.


Asunto(s)
Aorta/cirugía , Válvula Aórtica/cirugía , Implantación de Prótesis Vascular , Implantación de Prótesis de Válvulas Cardíacas , Análisis Actuarial , Anciano , Aneurisma de la Aorta/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Bioprótesis , Femenino , Humanos , Modelos Logísticos , Masculino , Análisis Multivariante , Complicaciones Posoperatorias/mortalidad , Reoperación , Factores de Riesgo , Análisis de Supervivencia , Técnicas de Sutura
8.
Cardiovasc Surg ; 5(1): 125-8, 1997 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-9158134

RESUMEN

This report describes the authors' clinical experience with expanded polytetrafluorethylene (e-PTFE) sutures to replace the anterior mitral leaflet chordae for valve repair. Between November 1986 and July 1995, 203 patients underwent operations with e-PTFE chordae insertion. Among these, 122 had artificial chordae utilized for anterior mitral leaflet repair. Four patients had the valve replaced during the same operation because of an unsatisfactory result. One patient died from respiratory insufficiency 16 days after operation. Transoesophageal echocardiography at discharge from hospital showed no evidence of regurgitation in 81 cases, and trivial regurgitation in 36. During a mean follow-up of 36.6 (range 1-106) months two other patients died from causes unrelated to the valve repair, while one patient had a transient ischaemic attack returning to sinus rhythm. Two patients were reoperated on 12 and 18 months respectively after their initial operation for progression of valvular degeneration causing natural chordae rupture. Among the remaining 113 patients, 111 are in New York Heart Association functional class I and yearly transoesophageal echocardiography has shown absent or trivial regurgitation. The utilization of e-PTFE as artificial chordae for anterior mitral leaflet pathology is a safe and reliable procedure, yielding excellent results and increasing the number of candidates for valve repair.


Asunto(s)
Cuerdas Tendinosas/cirugía , Ecocardiografía Transesofágica , Insuficiencia de la Válvula Mitral/cirugía , Prolapso de la Válvula Mitral/cirugía , Politetrafluoroetileno , Complicaciones Posoperatorias/diagnóstico por imagen , Suturas , Adolescente , Adulto , Anciano , Cuerdas Tendinosas/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Prótesis Valvulares Cardíacas , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/mortalidad , Prolapso de la Válvula Mitral/diagnóstico por imagen , Prolapso de la Válvula Mitral/mortalidad , Complicaciones Posoperatorias/mortalidad , Tasa de Supervivencia
9.
J Heart Valve Dis ; 5(6): 656-61, 1996 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-8953444

RESUMEN

BACKGROUND AND AIMS OF THE STUDY: Pericardial xenografts were introduced for clinical use following evidence of their good hemodynamic characteristics in laboratory tests; however, their efficiency in comparison with porcine valves has not been fully assessed. Pericarbon, a new type of pericardial bioprosthesis, has been recently developed in order to provide better hemodynamic performances and longer durability than such bioprostheses currently in use. METHODS: Fifteen patients operated on for aortic valve replacement with a 23 mm Pericarbon and a sex- and age-matched group operated on with a 23 mm Hancock II bioprosthesis were submitted to echocardiographic and Doppler examinations in order to compare the hemodynamic performance of the two devices. RESULTS: Peak transvalvular gradients for Pericarbon and Hancock II bioprostheses (38.9 +/- 13.0 vs. 33.9 +/- 13.0 mmHg; p = 0.294) and mean transvalvular gradients (24.7 +/- 7.6 vs. 20.8 +/- 9.9 mmHg, p = 0.24) showed no significant difference. However, the indexed effective prosthetic dynamic area was significantly larger for the Hancock II device (0.73 +/- 0.14 vs. 0.62 +/- 0.13 cm2; p < 0.05). CONCLUSIONS: When installed as 23 mm pericardial bioprostheses, the Pericarbon device appears not to demonstrate superior hemodynamic performance to that of the Hancock II; however, additional studies are needed to provide a definitive conclusion.


Asunto(s)
Bioprótesis , Prótesis Valvulares Cardíacas , Hemodinámica/fisiología , Anciano , Aorta , Ecocardiografía , Ecocardiografía Doppler , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad
10.
Heart ; 75(3): 301-6, 1996 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-8800997

RESUMEN

OBJECTIVE: To assess the diagnostic potential of transthoracic and transoesophageal echocardiography for the detection of traumatic cardiovascular injuries in patients suffering from severe blunt chest trauma. DESIGN: Prospective study over a three year period. SETTING: A regional cardiothoracic centre. PATIENTS: 134 consecutive patients (94 M/40 F; mean age 38 (SD 14) years) suffering from severe blunt chest trauma (injury severity score 33.5 (18.2)). Most patients (89%) were victims of motor vehicle accidents. EVALUATION: All patients underwent transthoracic and transoesophageal echocardiography within 8 h of admission. Aortography was performed in the first 20 patients and in a further five equivocal cases. RESULTS: Transthoracic echocardiography provided suboptimal images in 83 patients, detecting three aortic ruptures, 28 pericardial effusions (one cardiac tamponade), 35 left pleural effusions, and 15 myocardial contusions. Transoesophageal echocardiography was feasible in 131 patients and detected 14 aortic ruptures (13 at the isthmus), 40 pericardial effusions, 51 left pleural effusions, 34 periaortic haematomas, 45 myocardial contusions, right atrial laceration in one patient with cardiac tamponade, one tricuspid valve rupture, and one severe mitral regurgitation caused by annular disruption. For the detection of aortic rupture transoesophageal echocardiography showed 93% sensitivity, 98% specificity, and 98% accuracy. Time to surgery was significantly shorter (30 (12) v 71 (21) min; P < 0.05) for patients operated on only on the basis of transoesophageal echocardiographic findings. CONCLUSIONS: Transthoracic echocardiography has low diagnostic yield in severe blunt chest trauma, while transoesophageal echocardiography provides accurate diagnosis in a short time at the bedside, is inexpensive, minimally invasive, and does not interfere with other diagnostic or therapeutic procedures.


Asunto(s)
Sistema Cardiovascular/lesiones , Ecocardiografía Transesofágica , Ecocardiografía , Lesiones Cardíacas/diagnóstico por imagen , Traumatismos Torácicos/diagnóstico por imagen , Heridas no Penetrantes/diagnóstico por imagen , Accidentes de Tránsito , Adolescente , Adulto , Anciano , Rotura de la Aorta/diagnóstico por imagen , Aortografía , Sistema Cardiovascular/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad
12.
Int J Card Imaging ; 10(4): 305-8, 1994 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-7722352

RESUMEN

Acute thrombosis is a very severe complication in the replacement of mechanical prostheses and most often fatal if immediate treatment is not implemented. We describe a case in which an acute thrombosis of a mitral tilting disk prosthesis was adequately diagnosed by transesophageal echocardiography and immediate surgical replacement of the dysfunctioning device was possible without catheterizing the patient.


Asunto(s)
Ecocardiografía Transesofágica , Prótesis Valvulares Cardíacas , Válvula Mitral/diagnóstico por imagen , Complicaciones Posoperatorias/diagnóstico por imagen , Trombosis/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/cirugía , Complicaciones Posoperatorias/cirugía , Diseño de Prótesis , Falla de Prótesis , Reoperación
13.
Am J Cardiol ; 74(6): 590-5, 1994 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-8074043

RESUMEN

The aim of this study was to assess the comparative diagnostic value of transesophageal echocardiography (TEE) and retrograde aortography for morphologic evaluation and anatomic mapping of aortic dissection. Seventy patients (aged 18 to 79 years) were prospectively evaluated with both techniques for suspected aortic dissection. In 64 patients, findings on aortography and TEE could be validated against intraoperative (n = 53) and postmortem (n = 11) findings. Examination time was significantly shorter for TEE (9 +/- 6 vs 48 +/- 25 minutes; p < 0.001). For the detection of aortic dissection, aortography showed lower sensitivity (87.5% vs 97.5%) and negative predictive value (85.3% vs 96.7%; both trends did not reach statistical significance) due mostly to the inability to identify noncommunicating dissection (dissection without intimal tears). For the epiphenomena of aortic dissection, aortography was significantly more accurate (97.2% vs 78%; p < 0.05) in assessing the site of entry, and TEE was more accurate in identifying thrombus formation (90% vs 65%; p < 0.05). There was no significant difference between aortography and TEE with regard to assessing secondary tears, aortic regurgitation, coronary dissection, and extension of the dissection. Thus, both TEE and aortography offer detailed anatomic mapping for guided surgical interventions. In elective patients, integration of both techniques seems the best approach; in unstable patients, TEE may be preferential because it is less invasive, requires no contrast injection, and provides accurate diagnosis in a short time at the bedside.


Asunto(s)
Aneurisma de la Aorta Torácica/diagnóstico , Disección Aórtica/diagnóstico , Aortografía , Ecocardiografía Transesofágica , Adulto , Anciano , Disección Aórtica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aortografía/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad
14.
J Thorac Cardiovasc Surg ; 108(1): 37-41, 1994 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-8028377

RESUMEN

Among 106 patients operated on for implantation of artificial mitral chordae (expanded polytetrafluoroethylene), usually associated with other traditional procedures, 82 had degenerative valve disease. Two of them had the valve replaced during the same operation because of residual regurgitation, and one patient died (1.3%) of respiratory insufficiency. Seventy-nine patients left the hospital and were followed up to 84 months. No late deaths and only one valve-related complication were reported. This occurred in a patient who required reoperation after 18 months for sudden recurrence of mitral regurgitation caused by the rupture of natural chordae, which had been shortened during the first procedure, whereas the artificial chordae had retained their function. The clinical experience confirms positive experimental data, because this technique was reliable with lasting results. Application of artificial chordae, associated with other traditional techniques, is useful to improve the results and to extend the indications for mitral valve repair.


Asunto(s)
Cuerdas Tendinosas/cirugía , Prolapso de la Válvula Mitral/cirugía , Politetrafluoroetileno , Prótesis e Implantes , Adolescente , Adulto , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Reoperación , Suturas
16.
J Card Surg ; 8(1): 79-84, 1993 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-8422493

RESUMEN

From May 1985 to May 1992, 169 patients underwent surgery for mitral valve repair. In 87% of these patients, the valve reconstruction involved the mitral annulus. At the beginning, in an effort to preserve systolic movement of the annulus and avoid the implant of prosthetic materials inside the heart, we mainly used simple suture annuloplasty in 66 patients. When we reoperated upon three patients only a few months after reconstruction of the mitral valve for a dehiscence of the suture annuloplasty, we decided to perform ring annuloplasty with the Carpentier ring in 23 patients. Though we have not seen any problems with the Carpentier ring in our series, we performed a suture annuloplasty reinforced with a strip of autologous pericardium to eliminate all prosthetic material. Since introducing this technique in 1989, we have used this annuloplasty in 58 patients. We have not observed any dehiscence of the suture or other complications related to this procedure. Three patients with a pericardial annuloplasty underwent reoperation for other reasons; the autologous pericardium was perfectly attached to the annulus, covered by a smooth layer of fibrous tissue without calcification. After this encouraging initial experience, we believe that long-term follow-up is necessary to confirm that autologous pericardium is an effective method of mitral annulus repair.


Asunto(s)
Enfermedades de las Válvulas Cardíacas/cirugía , Válvula Mitral/cirugía , Pericardio/cirugía , Técnicas de Sutura , Humanos , Reoperación
17.
Ann Thorac Surg ; 54(5): 952-7; discussion 957-8, 1992 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-1417292

RESUMEN

Durability of a new bioprosthesis, the Meadox-Gabbay unileaflet pericardial xenograft, was evaluated by reviewing a series of 12 patients who received this device in the mitral position from 1983 to 1985. Bioprosthetic failure necessitated reoperation in 5 patients 21, 22, 53, 66, and 81 months after placement. Three patients died of cardiac failure after 31, 52, and 70 months; no postmortem examinations were done. In 2 of the 3 patients, an echocardiographic study had shown signs of valvular dysfunction. Pathological examination of five available explants revealed the presence of redundancy and stretching of the single pericardial leaflet in all of them; in one, this lesion alone caused severe prosthetic incompetence. Other pathological findings included cusp and commissural calcification and commissural tears with or without calcification. Histologic examination and electron microscopy showed intrinsic calcification involving both collagen bundles and cellular debris and various degrees of collagen disruption. In this limited series of patients, the Meadox-Gabbay pericardial xenograft demonstrated various modes of failure that markedly impair its durability and render it unsuitable as a cardiac valve substitute.


Asunto(s)
Bioprótesis , Prótesis Valvulares Cardíacas , Válvula Mitral/cirugía , Adulto , Anciano , Femenino , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/patología , Pericardio , Diseño de Prótesis , Falla de Prótesis , Reoperación
18.
J Card Surg ; 7(2): 117-25, 1992 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-1606364

RESUMEN

The problems encountered in coronary artery reattachment when the ascending aorta and aortic valve are replaced with a composite graft induced Gallucci and one of the authors to develop a new aortovalvular prosthesis in clinical practice. The unique transverse ovoidal shape of this graft is intended to conform to the natural aortic root and facilitate the coronary anastomoses and minimize bleeding. We present our 6-year experience with 56 patients operated upon with this prosthesis. In all patients we were able to connect the coronary arteries directly to the graft without complications including hemorrhage or distortion of the coronary ostia. The survivors were evaluated with chest X ray, two-dimensional echocardiography, and conventional or digital subtraction angiography to detect the presence of pseudoaneurysms at the site of the coronary anastomosis, reported by others that have used the composite graft technique. The notable absence of this complication in our patients at a mean follow-up of 41 months (range 3-71) documents that this ovoidal composite graft is a reliable tool in the treatment of aortic root pathology.


Asunto(s)
Aorta/cirugía , Válvula Aórtica/cirugía , Prótesis Vascular/normas , Procedimientos Quirúrgicos Cardíacos/normas , Prótesis Valvulares Cardíacas/normas , Diseño de Prótesis/normas , Procedimientos Quirúrgicos Cardíacos/métodos , Procedimientos Quirúrgicos Cardíacos/mortalidad , Estudios de Seguimiento , Humanos , Italia/epidemiología , Complicaciones Posoperatorias/epidemiología , Falla de Prótesis , Tasa de Supervivencia , Técnicas de Sutura
19.
J Card Surg ; 6(4): 432-8, 1991 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-1815766

RESUMEN

Failure of reconstructive procedures of the mitral valve is often ascribed to diffuse alteration of the subvalvular apparatus, which prevents the utilization of well-established techniques such as chordal transposition or shortening. For this reason, in 1986 after 2 years of animal experiments, we started the clinical use of expanded-polytetrafluoroethylene mitral chordae. Details of the surgical procedure are presented. Our experience is based on 51 patients with a mean follow-up of about 20 months (range 3-57). Four patients had the valve replaced during the same operation: one patient died later of cardiac failure and two underwent reoperation, 8 and 18 months after operation. Forty-one patients are in New York Heart Association Functional Class I and three in Class II. We suggest this technique in association with other traditional procedures to increase the number of mitral valves repaired, mostly because of degenerative etiology.


Asunto(s)
Cuerdas Tendinosas/cirugía , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral/cirugía , Adulto , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Músculos Papilares/cirugía , Politetrafluoroetileno , Reoperación , Técnicas de Sutura
20.
Thorac Cardiovasc Surg ; 39(4): 205-7, 1991 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-1948969

RESUMEN

Transesophageal echocardiography may provide additional morphologic information in many cases of cardiovascular disease when compared with the traditional transthoracic approach. In our department 3 male patients underwent surgical treatment with preoperative diagnosis of left-ventricular outflow-tract obstruction. We describe the intraoperative transesophageal echocardiographic findings and in which way they guided the surgical strategy.


Asunto(s)
Ecocardiografía , Obstrucción del Flujo Ventricular Externo/cirugía , Adolescente , Anciano , Humanos , Masculino , Persona de Mediana Edad , Obstrucción del Flujo Ventricular Externo/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA