Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Intervalo de año de publicación
1.
Cardiol J ; 23(1): 17-22, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26412601

RESUMEN

BACKGROUND: The noncontact mapping system facilitates the mapping of premature ventricular contractions (PVCs) and ventricular tachycardia (VT) using a 64-electrode expandable balloon catheter (ARRAY, St. Jude Medical). The aim of this study is to analyze the results and follow-up of the PVC ablation using this system. METHODS AND RESULTS: Prospective and consecutive patients with frequent PVCs (6,000 or more) or monomorphic VT, suspected to be originated on the right ventricular outflow tract (RVOT), were included. The balloon catheter was positioned in the RVOT. Eighteen patients, 9 women, mean age 48 years (youngest/oldest 19-65) were included. Sixteen patients presented no structural heart disease. The origin of the arrhythmia was RVOT (n = 15), right ventricular inflow tract (n = 1), and left ventricular outflow tract (n = 2). Acute success was achieved in 15 patients; in 2 patients radiofrequency was not applied due to security reasons (origin site close to left coronary artery origin). The mean follow-up was 15 months (min. 4, max. 26); 13 patients presented abolition of the arrhythmia without drugs and 1 patient required antiarrhythmic drugs for arrhythmia control (previously ineffective). As an only complication, a femoral artery-venous fistula was observed. CONCLUSIONS: The noncontact mapping system using a multielectrode balloon allows right ventricular arrhythmia treatment with a high rate of efficacy and safety.


Asunto(s)
Catéteres Cardíacos , Ablación por Catéter/instrumentación , Electrodos , Taquicardia Ventricular/cirugía , Complejos Prematuros Ventriculares/cirugía , Adulto , Anciano , Antiarrítmicos/uso terapéutico , Ablación por Catéter/efectos adversos , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/fisiopatología , Adulto Joven
2.
Rev. argent. cardiol ; 82(4): 285-291, ago. 2014. ilus, graf, tab
Artículo en Español | LILACS | ID: lil-734512

RESUMEN

Introducción La ablación por radiofrecuencia de la fibrilación auricular es más eficaz que las drogas antiarrítmicas en el control de los síntomas, particularmente cuando la arritmia es paroxística. Consiste en un procedimiento laborioso y complejo no exento de complicaciones. Objetivo Evaluar los resultados de la ablación por radiofrecuencia en una población seleccionada consecutiva con fibrilación auricular recurrente y refractaria a drogas antiarrítmicas. Material y métodos Se evaluaron 111 pacientes, 90 hombres, con fibrilación auricular paroxística (n = 75) o persistente (n = 36), refractaria a 2 (1,5-3) drogas antiarrítmicas que fueron seleccionados para la ablación por radiofrecuencia. Todos los procedimientos se realizaron siguiendo una metodología uniforme. La edad fue de 56 ± 11 años, con un diámetro de la aurícula izquierda de 41,5 (39-45) mm y fracción de eyección del ventrículo izquierdo del 60% (56,5-66,5%). Se realizaron 126 procedimientos de ablación por radiofrecuencia, incluyendo 15 segundos procedimientos. Se aislaron 476/489 (97,3%) venas pulmonares. Veinticinco pacientes (22,5%) presentaron actividad ectópica espontánea de las venas pulmonares. Se presentaron complicaciones no mortales en 7/126 procedimientos (5,5%), que se resolvieron satisfactoriamente. Tres pacientes presentaron complicaciones vasculares y se observó una complicación anestésica, un taponamiento cardíaco subagudo, una pericarditis sin derrame y una estenosis de vena pulmonar. Luego de un seguimiento de 22 (13-35) meses, 83 pacientes (74,8%) se mantuvieron en ritmo sinusal sin drogas antiarrítmicas. Los 28 pacientes restantes (25,2%) presentaron recurrencias. Cuatro de ellos respondieron satisfactoriamente a estas drogas (previamente ineficaces), ocho tuvieron fibrilación auricular a pesar de recibir drogas antiarrítmicas y 1 paciente se encuentra en plan de reablación. A los 15 pacientes restantes se les realizó un segundo procedimiento de ablación. Diez de ellos se mantienen sin recurrencias luego de 12 (9-31) meses. Conclusión En esta serie consecutiva de pacientes con fibrilación auricular refractaria a drogas antiarrítmicas, la ablación por radiofrecuencia mostró una tasa de éxito adecuada y un nivel bajo de complicaciones.


Introduction Radiofrequency catheter ablation of atrial fibrillation is more effective than antiarrhythmic drugs for symptoms control, particularly in paroxysmal atrial fibrillation. The procedure is laborious and complex and not exempt from complications. Objective The aim of this study was to evaluate the outcomes of radiofrequency catheter ablation in a consecutive and selected population with recurrent atrial fibrillation refractory to antiarrhythmic drugs. Methods One-hundred and eleven patients (90 men) with paroxysmal (n = 75) or persistent (n = 36) atrial fibrillation, refractory to 2 (1.5-3) antiarrhythmic drugs were selected for radiofrequency catheter ablation. All the procedures were performed following a uniform methodology. Mean age was 56 ± 11 years, left atrial diameter was 41.5 (39-45) mm and left ventricular ejection fraction was 60% (56.5-66.5%). A total of 126 radiofrequency catheter ablation procedures were performed, including 15 second procedures, and 476/489 (97.3%) pulmonary veins were isolated. Twenty-five patients (22.5%) presented spontaneous ectopic activity in the pulmonary veins. Nonfatal complications occurred in 7/126 procedures (5.5%) and were satisfactorily resolved. Three patients presented vascular complications; other complications included one related to anesthesia, one subacute cardiac tamponade, one pericarditis without effusion and one pulmonary vein stenosis. After 22-month follow-up (13-35 months), 83 patients (74.8%) remained in sinus rhythm without antiarrhythmic drugs. The remaining 28 patients (25.2%) presented recurrences. Four of these patients had a favorable response to these previously inefficient drugs, 8 had atrial fibrillation in spite of receiving antiarrhythmic drugs and 1 patient will undergo a new ablation. The remaining 15 patients underwent a second ablation procedure; 10 of them are free of recurrences after 12 (9-31) months. Conclusion In this consecutive series of patients with atrial fibrillation refractory to drugs, radiofrequency catheter ablation showed an adequate rate of success and low level of complications.

3.
Rev. argent. cardiol ; 82(4): 285-291, ago. 2014. ilus, graf, tab
Artículo en Español | BINACIS | ID: bin-131330

RESUMEN

Introducción La ablación por radiofrecuencia de la fibrilación auricular es más eficaz que las drogas antiarrítmicas en el control de los síntomas, particularmente cuando la arritmia es paroxística. Consiste en un procedimiento laborioso y complejo no exento de complicaciones. Objetivo Evaluar los resultados de la ablación por radiofrecuencia en una población seleccionada consecutiva con fibrilación auricular recurrente y refractaria a drogas antiarrítmicas. Material y métodos Se evaluaron 111 pacientes, 90 hombres, con fibrilación auricular paroxística (n = 75) o persistente (n = 36), refractaria a 2 (1,5-3) drogas antiarrítmicas que fueron seleccionados para la ablación por radiofrecuencia. Todos los procedimientos se realizaron siguiendo una metodología uniforme. La edad fue de 56 ± 11 años, con un diámetro de la aurícula izquierda de 41,5 (39-45) mm y fracción de eyección del ventrículo izquierdo del 60% (56,5-66,5%). Se realizaron 126 procedimientos de ablación por radiofrecuencia, incluyendo 15 segundos procedimientos. Se aislaron 476/489 (97,3%) venas pulmonares. Veinticinco pacientes (22,5%) presentaron actividad ectópica espontánea de las venas pulmonares. Se presentaron complicaciones no mortales en 7/126 procedimientos (5,5%), que se resolvieron satisfactoriamente. Tres pacientes presentaron complicaciones vasculares y se observó una complicación anestésica, un taponamiento cardíaco subagudo, una pericarditis sin derrame y una estenosis de vena pulmonar. Luego de un seguimiento de 22 (13-35) meses, 83 pacientes (74,8%) se mantuvieron en ritmo sinusal sin drogas antiarrítmicas. Los 28 pacientes restantes (25,2%) presentaron recurrencias. Cuatro de ellos respondieron satisfactoriamente a estas drogas (previamente ineficaces), ocho tuvieron fibrilación auricular a pesar de recibir drogas antiarrítmicas y 1 paciente se encuentra en plan de reablación. A los 15 pacientes restantes se les realizó un segundo procedimiento de ablación. Diez de ellos se mantienen sin recurrencias luego de 12 (9-31) meses. Conclusión En esta serie consecutiva de pacientes con fibrilación auricular refractaria a drogas antiarrítmicas, la ablación por radiofrecuencia mostró una tasa de éxito adecuada y un nivel bajo de complicaciones.(AU)


Introduction Radiofrequency catheter ablation of atrial fibrillation is more effective than antiarrhythmic drugs for symptoms control, particularly in paroxysmal atrial fibrillation. The procedure is laborious and complex and not exempt from complications. Objective The aim of this study was to evaluate the outcomes of radiofrequency catheter ablation in a consecutive and selected population with recurrent atrial fibrillation refractory to antiarrhythmic drugs. Methods One-hundred and eleven patients (90 men) with paroxysmal (n = 75) or persistent (n = 36) atrial fibrillation, refractory to 2 (1.5-3) antiarrhythmic drugs were selected for radiofrequency catheter ablation. All the procedures were performed following a uniform methodology. Mean age was 56 ± 11 years, left atrial diameter was 41.5 (39-45) mm and left ventricular ejection fraction was 60% (56.5-66.5%). A total of 126 radiofrequency catheter ablation procedures were performed, including 15 second procedures, and 476/489 (97.3%) pulmonary veins were isolated. Twenty-five patients (22.5%) presented spontaneous ectopic activity in the pulmonary veins. Nonfatal complications occurred in 7/126 procedures (5.5%) and were satisfactorily resolved. Three patients presented vascular complications; other complications included one related to anesthesia, one subacute cardiac tamponade, one pericarditis without effusion and one pulmonary vein stenosis. After 22-month follow-up (13-35 months), 83 patients (74.8%) remained in sinus rhythm without antiarrhythmic drugs. The remaining 28 patients (25.2%) presented recurrences. Four of these patients had a favorable response to these previously inefficient drugs, 8 had atrial fibrillation in spite of receiving antiarrhythmic drugs and 1 patient will undergo a new ablation. The remaining 15 patients underwent a second ablation procedure; 10 of them are free of recurrences after 12 (9-31) months. Conclusion In this consecutive series of patients with atrial fibrillation refractory to drugs, radiofrequency catheter ablation showed an adequate rate of success and low level of complications.(AU)

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...