1.
Cardiovasc Revasc Med ; 34: 40-45, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-33547024

RESUMEN

INTRODUCTION: We aimed to compare conduction dynamics and need for permanent pacemaker implantation (PPI) after CoreValve, Evolut R and PRO (transcatheter aortic valve replacement (TAVR)). METHODS: Patients were stratified based on conduction at baseline; Cohort A had normal conduction, Cohort B had conduction abnormalities including atrioventricular (AV)-block, fascicular block or complete bundle branch block. Three different dynamic QRS-patterns were defined: stable QRS-duration, transient QRS-prolongation and persistent QRS-prolongation. We performed multivariable regression analysis to estimate the effect of the three separate transcatheter heart valves (THV's) on need for PPI at 30 days. RESULTS: TAVR was performed with CoreValve (N = 113), Evolut R (N = 157) or Evolut PRO (N = 92). Conduction dynamics were similar between the different THVs. Overall, Evolut R and PRO showed a tendency towards less PPI compared to CoreValve (17% vs. 19% vs. 27%, P = 0.08), which was driven by a lower PPI rate in Cohort A (6% vs. 11% vs. 25%, P = 0.002). Need for PPI was restricted to patients with persistent QRS-prolongation in Cohort A (26/106) but did not correlate with conduction dynamics in Cohort B. In multivariable logistic regression analysis the use of Evolut R (OR 0.38, 95% CI 0.19-0.78, P = 0.008) and PRO (OR 0.41, 95% CI 0.19-0.91, P-value = 0.028) were independently associated with less need for PPI. CONCLUSION: The newer generations Evolut R and PRO were associated with less PPI compared to CoreValve. Acquired persistent conduction abnormalities predicted PPI after TAVR only in patients with normal conduction at baseline. Our findings may help identify eligible patients for early discharge after Evolut R/PRO TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
2.
J Am Coll Cardiol ; 77(22): 2796-2803, 2021 06 08.
Artículo en Inglés | MEDLINE | ID: mdl-34082909

RESUMEN

BACKGROUND: The study investigators previously reported that moderate aortic stenosis (AS) is associated with a poor prognosis in patients with heart failure (HF) with reduced left ventricular ejection fraction (LVEF) (HFrEF). However, the respective contribution of moderate AS versus HFrEF to the outcomes of these patients is unknown. OBJECTIVES: This study sought to determine the impact of moderate AS on outcomes in patients with HFrEF. METHODS: The study included 262 patients with moderate AS (aortic valve area >1.0 and <1.5 cm2; and peak aortic jet velocity >2 and <4 m/s, at rest or after dobutamine stress echocardiography) and HFrEF (LVEF <50%). These patients were matched 1:1 for sex, age, estimated glomerular filtration rate, New York Heart Association functional class III to IV, presence of diabetes, LVEF, and body mass index with patients with HFrEF but no AS (i.e., peak aortic jet velocity <2 m/s). The endpoints were all-cause mortality and the composite of death and HF hospitalization. RESULTS: A total of 262 patients with HFrEF and moderate AS were matched with 262 patients with HFrEF and no AS. Mean follow-up was 2.9 ± 2.2 years. In the moderate AS group, mean aortic valve area was 1.2 ± 0.2 cm2, and mean gradient was 14.5 ± 4.7 mm Hg. Moderate AS was associated with an increased risk of mortality (hazard ratio [HR]: 2.98; 95% confidence interval [CI]: 2.08 to 4.31; p < 0.0001) and of the composite of HF hospitalization and mortality (HR: 2.34; 95% CI: 1. 72 to 3.21; p < 0.0001). In the moderate AS group, aortic valve replacement (AVR) performed in 44 patients at a median follow-up time of 10.9 ± 16 months during follow-up was associated with improved survival (HR: 0.59; 95% CI: 0.35 to 0.98; p = 0.04). Notably, surgical AVR was not significantly associated with improved survival (p = 0.92), whereas transcatheter AVR was (HR: 0.43; 95% CI: 0.18 to 1.00; p = 0.05). CONCLUSIONS: In this series of patients with HFrEF, moderate AS was associated with a marked incremental risk of mortality. AVR, and especially transcatheter AVR during follow-up, was associated with improved survival in patients with HFrEF and moderate AS. These findings provide support to the realization of a randomized trial to assess the effect of early transcatheter AVR in patients with HFrEF and moderate AS.


Asunto(s)
Estenosis de la Válvula Aórtica/complicaciones , Insuficiencia Cardíaca/complicaciones , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Femenino , Insuficiencia Cardíaca/mortalidad , Hospitalización/estadística & datos numéricos , Humanos , Masculino , Persona de Mediana Edad , Países Bajos/epidemiología , Quebec/epidemiología , Estudios Retrospectivos , Volumen Sistólico
3.
Acta Cardiol ; 76(2): 185-193, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31920151

RESUMEN

BACKGROUND: Elevated pulmonary artery pressure (PAP) in patients with severe aortic stenosis (AS) is a strong predictor of adverse prognosis. This study sought to assess the relation between PAP and clinical and echocardiographic parameters in elderly patients with severe AS, as well as to identify the determinants of the change in PAP after transcatheter aortic valve implantation (TAVI). METHODS: The study included 170 subjects (age 81 ± 7 years, 45% men) with symptomatic severe AS who were treated by TAVI. They underwent a clinical evaluation and a transthoracic echocardiography before the TAVI procedure and 6 months after. RESULTS: In a multivariable analysis, the independent predictors for baseline PAP were the body mass index (BMI) (ß = 0.21, p = .006), COPD GOLD class (ß = 0.20; p = .009), the E/e' ratio (ß = 0.20; p = .02) and the degree of aortic regurgitation (ß = 0.20; p = .01). After TAVI, there was significantly less (51% vs. 29%, p<.0001) pulmonary hypertension, defined as a tricuspid regurgitation velocity ≥2.8 m/s. The baseline variables related to an improvement in PAP were the tricuspid regurgitation velocity (p = .0001) and the E/e' (p = .005). From the parameters potentially modified with TAVI, the only independent predictor of PAP variation was the change in the E/e' ratio (ß = 0.23; p = .01). CONCLUSIONS: Independent predictors for baseline PAP in elderly patients with symptomatic AS were the BMI, GOLD class, the aortic regurgitation and the E/e' ratio. The baseline predictors for a change in PAP 6 months after TAVI were the baseline PAP and E/e', with only the change in the E/e' ratio being correlated to the change in PAP.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Presión Arterial , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Ecocardiografía , Femenino , Humanos , Masculino , Arteria Pulmonar/diagnóstico por imagen
4.
EuroIntervention ; 16(14): 1141-1147, 2021 02 19.
Artículo en Inglés | MEDLINE | ID: mdl-32894232

RESUMEN

AIMS: The aim of this study was to investigate the total amount, size and heterogeneity of debris captured among different transcatheter valve types and while repositioning. METHODS AND RESULTS: A total of 328 patients who underwent transcatheter aortic valve implantation (TAVI) with the SENTINEL cerebral embolic protection (CEP) at our centre were eligible. Histopathological and semiquantitative analysis of captured debris was performed and data were entered into our prospective database. TAVI was performed with either the Evolut R/PRO (N=123), SAPIEN 3 (N=113) or Lotus valve (N=92). Capture of debris occurred in 98% of patients. Lotus TAVI resulted in more frequent foreign body material (62% vs 40% vs 47%, p=0.006), endothelium (49% vs 30% vs 16%, p<0.0005), calcified material (33% vs 12% vs 24%, p=0.001) and myocardial tissue (19% vs 11% vs 2%, p<0.0005) compared to SAPIEN 3 or Evolut R/PRO. Native (functional) bicuspid valves (OR 2.91, 95% CI: 1.20-7.03, p=0.02) and Lotus (OR 2.44, 95% CI: 1.14-5.24, p=0.02) were associated with the highest risk for dislodging particles ≥1,000 um. Valve repositioning was independently associated with larger amounts of debris (OR 2.96, 95% CI: 1.42-6.16, p=0.004). CONCLUSIONS: All THV platforms had similar amounts of captured debris. THV repositioning seemed to be associated with a higher risk for dislodging greater amounts of debris to the brain.


Asunto(s)
Estenosis de la Válvula Aórtica , Dispositivos de Protección Embólica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
5.
Radiol Case Rep ; 15(9): 1705-1708, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32733625

RESUMEN

The contribution of neurological symptomatology to morbidity and mortality after infection with Severe Acute Respiratory Syndrome-associated Coronavirus (SARS CoV II) is ill-defined. We hereby present a case of a 57-year old male patient, in excellent physical condition, who was admitted to the Intensive Care Unit (ICU), with respiratory distress duo to SARS CoV II-induced bilateral pneumonia. After 2 weeks at the ICU, with respiratory conditions improving, the patient developed lethal cerebral edema. This case advocates regular wake-up calls in Coronavirus disease 2019 patients for neurological (radiological) evaluation to provide rapid diagnosis and a therapeutic window for fulminant central nervous system complications.

6.
Interv Cardiol Clin ; 8(4): 393-402, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31445723

RESUMEN

Multiple transcatheter heart valve iterations have created an interesting range of options with which to perform transcatheter aortic valve replacement. The Lotus valve has several attractive features. The ability to eradicate even mild paravalvular leak mirrors the outcomes of surgical aortic valve replacement. New design iterations of the Lotus valve and refined sizing algorithms may help mitigate the need for permanent pacemaker implantation and consolidate its best-in-class results in terms of paravalvular leak. Ongoing trials should help define the safety and efficacy of the Lotus transcatheter heart valve in contemporary practice.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Humanos , Diseño de Prótesis
7.
Circ Cardiovasc Interv ; 12(6): e007605, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-31195822

RESUMEN

Background We aimed to compare the rate of neurological events in patients with or without cerebral embolic protection (CEP) during transcatheter aortic valve replacement (TAVR). Methods and Results Data on clinical end points including neurological events ≤30 days post-TAVR were collected for all patients who underwent transfemoral TAVR in 2 academic tertiary care institutions. Patients were matched through propensity scoring, which resulted in 333 pairs of patients with versus without CEP out of a total of 831 consecutive patients. The median age was 81 (76-85) years, and the median logistic EuroScore was 14% (9%-20%). The CEP group experienced less neurological events at 24 hours (1% versus 4%; P=0.035) and at 30 days (3% versus 7%; P=0.029). There were significantly more disabling strokes in unprotected patients at 30 days (1% versus 4%; P=0.039). CEP was associated with significantly fewer neurological events at 24 hours after TAVR (odds ratio, 0.20; 95% CI, 0.06-0.73; P=0.015) by multiple regression analysis, while age and valve type did not contribute significantly. Overall, 67% (2 of 3) in the CEP versus 83% (10 of 12) in the non-CEP cohort experienced neurological events in protected areas (ie, not dependent on the left vertebral artery). Conclusions The use of filter-based CEP during TAVR was associated with less neurological events, especially in CEP-protected brain territories.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Dispositivos de Protección Embólica , Prótesis Valvulares Cardíacas , Embolia Intracraneal/prevención & control , Accidente Cerebrovascular/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Humanos , Embolia Intracraneal/diagnóstico por imagen , Embolia Intracraneal/etiología , Masculino , Países Bajos , Factores Protectores , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/etiología , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
8.
Ultrasound Med Biol ; 45(8): 1977-1986, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31079873

RESUMEN

We apply a high frame rate (over 500 Hz) tissue Doppler method to measure the propagation velocity of naturally occurring shear waves (SW) generated by aortic and mitral valves closure. The aim of this work is to demonstrate clinical relevance. We included 45 healthy volunteers and 43 patients with hypertrophic cardiomyopathy (HCM). The mitral SW (4.68 ± 0.66 m/s) was consistently faster than the aortic (3.51 ± 0.38 m/s) in all volunteers (p < 0.0001). In HCM patients, SW velocity correlated with E/e' ratio (r = 0.346, p = 0.04 for aortic SW and r = 0.667, p = 0.04 for mitral SW). A subgroup of 20 volunteers were matched for age and gender to 20 HCM patients. In HCM, the mean velocity of 5.1 ± 0.7 m/s for the aortic SW (3.61 ± 0.46 m/s in matched volunteers, p < 0.0001) and 6.88 ± 1.12 m/s for the mitral SW(4.65 ± 0.77 m/s in matched volunteers, p < 0.0001). A threshold of 4 m/s for the aortic SW correctly classified pathologic myocardium with a sensitivity of 95% and specificity of 90%. Naturally occurring SW can be used to assess differences between normal and pathologic myocardium.


Asunto(s)
Cardiomiopatía Hipertrófica/diagnóstico por imagen , Cardiomiopatía Hipertrófica/fisiopatología , Ecocardiografía/métodos , Adolescente , Adulto , Estudios de Factibilidad , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad , Adulto Joven
9.
Catheter Cardiovasc Interv ; 94(6): 795-805, 2019 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-30901147

RESUMEN

OBJECTIVES: To explore the prevalence of smoking, and its association with clinical and mortality outcome among patients undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: Less data exist regarding the effect of baseline smoking status on clinical and mortality outcome among patients undergoing TAVR. METHODS: Consecutive patients who underwent TAVR at two high volume Dutch centers were included. Smoking status was prospectively questioned by a structured interview at admission. Primary endpoint was 1-year all-cause mortality after TAVR. RESULTS: A total of 913 consecutive patients (80.1 ± 7.6 years; logistic EuroSCORE: 16.5 ± 9.9%) who underwent TAVR for severe aortic valve stenosis were included. There were 47% (n = 432) males, and 57% (n = 522) never-smokers, and 35% (n = 317) prior-smokers, and 8% (n = 74) current-smokers. Smokers (i.e., prior-smokers or current-smokers) were younger compared to never-smokers (78.9 ± 7.9 and 76.4 ± 8.0 vs. 81.3 ± 7.1, P < 0.000, respectively). Median follow-up time was 365 (interquartile range [IQR]: 280-365) days. Overall, prior-smoking was not associated with all-cause mortality at 1-year following TAVR (hazard ratio [HR] 0.83, 95% confidence interval [CI] 0.55-1.23). After stratification according to sex, male prior-smokers showed better 1-year survival after TAVR than male never-smokers (12% vs. 20%; P = 0.018, respectively, HR 0.52, 95% CI 0.29-0.89), while this reversed effect was not observed among female prior-smokers versus female never-smokers after TAVR (HR 1.70, 95% CI 0.95-3.05). CONCLUSIONS: Overall, baseline prior-smokers had similar 1-year mortality outcome after TAVR compared with baseline never-smokers. However, there was a reversed association between baseline prior-smoking status and 1-year mortality after TAVR among males, which could partially be explained due to the favorable baseline characteristics.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Fumar Cigarrillos/efectos adversos , Ex-Fumadores , No Fumadores , Fumadores , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Fumar Cigarrillos/mortalidad , Femenino , Humanos , Masculino , Países Bajos , Prevalencia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores Sexuales , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
10.
Catheter Cardiovasc Interv ; 93(6): 1116-1123, 2019 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-30773838

RESUMEN

AIMS: Patients with bicuspid valves represent a challenging anatomical subgroup for transcatheter aortic valve implantation (TAVI). This analysis evaluated the clinical outcomes of the fully repositionable and retrievable Lotus Valve System in patients with bicuspid aortic valves enrolled in the RESPOND post-market registry. METHODS AND RESULTS: The prospective, open-label RESPOND study enrolled 1,014 patients at 41 centers in Europe, New Zealand, and Latin America, 31 (3.1%) of whom had bicuspid aortic valves. The mean age in the bicuspid patient cohort was 76.4 years, 64.5% were male, and the baseline STS score was 6.0 ± 10.2. Procedural success was 100%, with no cases of malpositioning, valve migration, embolization, or valve-in-valve. Repositioning was attempted in 10 cases (32.3%). There was one death (3.2%) and one stroke (3.2%) at 30-day follow-up. Mean AV gradient was reduced from 48.7 ± 17.0 mmHg at baseline to 11.8 ± 5.1 mmHg at hospital discharge (P < 0.001); mean effective orifice area (EOA) was increased from 0.6 ± 0.2 cm2 to 1.7 ± 0.4 cm2 (P < 0.001). There were no cases of moderate or severe paravalvular leak (PVL) adjudicated by the core laboratory; four subjects (13.8%) had mild PVL, 5 (17.2%) had trace PVL. The rate of pacemaker (PM) implantation for PM-naïve patients was 22.2% (6/27). CONCLUSIONS: Data from the RESPOND registry demonstrate good clinical and echocardiographic outcomes up to 1 year postimplantation in patients with bicuspid aortic valves using the repositionable Lotus Valve.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Enfermedades de las Válvulas Cardíacas/complicaciones , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/fisiopatología , Enfermedad de la Válvula Aórtica Bicúspide , Europa (Continente) , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Hemodinámica , Humanos , América Latina , Masculino , Nueva Zelanda , Vigilancia de Productos Comercializados , Estudios Prospectivos , Diseño de Prótesis , Recuperación de la Función , Sistema de Registros , Factores de Tiempo , Resultado del Tratamiento
11.
12.
Circ Cardiovasc Interv ; 12(1): e007107, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30626202

RESUMEN

BACKGROUND: Sizing for transcatheter aortic valve implantation in bicuspid aortic valves (BAV) remains controversial. METHODS AND RESULTS: The aim of the BAVARD (Bicuspid Aortic Valve Anatomy and Relationship With Devices) retrospective registry is to capture the sizing ratios used for transcatheter aortic valve implantation in BAV and analyze the second-generation prostheses geometry postimplantation. About 101 patients with BAV along with available pre- and post-transcatheter aortic valve implantation multidetector computed tomography were compared with 88 tricuspid aortic valves (TAV) patients. Preprocedural multidetector computed tomography diagnosed type 0 and type 1 BAV in, respectively, 12.9% and 86.1 % of BAV. At baseline, the ellipticity index was similar between BAV and TAV patients: 1.2±0.1 versus 1.2±0.1, P=0.09. The mean annular oversizing was, respectively, 1.14±0.04 and 1.04±0.04, P<0.001, in TAV and BAV patients. The mean prosthesis intercommissural distance, ratio was 1.03±0.1. The mean diameter of the prostheses at the annulus matched the mean perimeter-derived diameter of the aortic annulus at baseline with TAV (23.3±2.2 versus 23.6±1.9, P=0.4) and was smaller with BAV (24±2.8 versus 26.8±3.1, P<0.01), confirming 11% underexpansion in BAV. Finally, in situ, prosthesis diameter and ellipticity followed the same pattern, with stable values from the distal edge to 12 mm above, in both groups. CONCLUSIONS: Second-generation prostheses similarly reshape the aortic annulus in TAV and BAV. Prostheses keep consistent diameters from distal edge to 12 mm in TAV and BAV. Prosthesis underexpansion is constantly observed in BAV. Annular-based sizing is accurate in BAV with minimal oversizing. The intercommissural distance, 4 mm above the annulus, could be integrated in gray zones. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT03495050.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Enfermedades de las Válvulas Cardíacas/complicaciones , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/fisiopatología , Enfermedad de la Válvula Aórtica Bicúspide , Europa (Continente) , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/fisiopatología , Humanos , Israel , Masculino , Tomografía Computarizada Multidetector , Diseño de Prótesis , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
13.
Cardiovasc Revasc Med ; 20(2): 126-132, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-29779973

RESUMEN

AIMS: We sought to evaluate the interaction of different aortic root phenotypes with self-expanding (SEV), balloon-expandable (BEV) and mechanically expanded (MEV) and the impact on significant aortic regurgitation. METHODS AND RESULTS: We included 392 patients with a SEV (N = 205), BEV (N = 107) or MEV (N = 80). Aortic annulus eccentricity index and calcification were measured by multi-slice CT scan. Paravalvular aortic regurgitation was assessed by contrast aortography (primary analysis) and transthoracic echocardiography (secondary analysis). In mildly calcified roots paravalvular regurgitation incidence was similar for all transcatheter heart valves (SEV 8.4%; BEV 9.1%; MEV 2.0% p = 0.27). Conversely, in heavily calcified roots paravalvular regurgitation incidence was significantly higher with SEV (SEV 45.9%; BEV 0.0%; MEV 0.0% p < 0.001). When paravalvular regurgitation was assessed by TTE, the overall findings were similar although elliptic aortic roots were associated with more paravalvular regurgitation with SEV (20.5% vs. BEV 4.5% vs. MEV 3.2%; p = 0.009). CONCLUSIONS: In heavily calcified aortic roots, significant paravalvular aortic regurgitation is more frequent with SEV than with BEV or MEV, but similar in mildly calcified ones. These findings may support patient-tailored transcatheter heart valve selection. CLASSIFICATIONS: Aortic stenosis; multislice computed tomography; transcatheter aortic valve replacement; paravalvular aortic regurgitation. CONDENSED ABSTRACT: We sought to evaluate the interaction of different aortic root phenotypes with self-expanding (SEV), balloon-expandable (BEV) and mechanically expanded (MEV) and the impact on significant aortic regurgitation. We included 392 patients with a SEV (N = 205), BEV (N = 107) or MEV (N = 80). Aortic annulus eccentricity index and calcification were measured by multi-slice CT scan. Paravalvular aortic regurgitation was assessed by contrast aortography and transthoracic echocardiography. We found that in heavily calcified aortic roots, significant paravalvular aortic regurgitation is more frequent with SEV than with BEV or MEV, but similar in mildly calcified ones.


Asunto(s)
Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/patología , Válvula Aórtica/cirugía , Calcinosis/cirugía , Prótesis Valvulares Cardíacas , Hemodinámica , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Aortografía/métodos , Valvuloplastia con Balón/efectos adversos , Calcinosis/diagnóstico por imagen , Calcinosis/fisiopatología , Angiografía por Tomografía Computarizada , Ecocardiografía , Humanos , Tomografía Computarizada Multidetector , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
14.
Front Cardiovasc Med ; 5: 111, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30175103

RESUMEN

Moderate aortic stenosis (AS) and reduced left ventricular ejection fraction (LVEF) constitute a clinical entity that has been proposed as a therapeutic target for transcatheter aortic valve replacement (TAVR). It is defined by a mean trans-aortic gradient between 20 and 40 mmHg and an aortic valve area between 1.0 and 1.5 cm2 in patients with LVEF < 50%. Retrospective data suggests a prevalence of 0.8% among patients referred for echocardiographic assessment. These patients are younger and show a higher frequency of previous myocardial infarction than those with severe AS randomized to TAVR in recent trials. In two retrospective studies including patients with moderate AS and reduced LVEF, a one-year mortality rate of 9 and 32% was reported, the latter in patients treated with medical therapy only during follow-up. Echocardiographic diagnosis of moderate AS poses challenges as current guidelines are directed to determine severe AS, and different presentations of moderate and mild AS have been generally neglected. Thus, the nomenclature would need to be revised and a description of possible scenarios is provided in this review. Dobutamine stress echocardiography and computed tomography are promising complementary tools. Likewise, a standardized clinical pathway is needed, in which a high level of suspicion and a low threshold for referral to a heart valve center is warranted. The Transcatheter Aortic Valve Replacement to UNload the Left ventricle in patients with Advanced heart failure (TAVR UNLOAD) trial (NCT02661451) is exploring whether TAVR would improve outcomes in patients receiving optimal heart failure therapy.

15.
Europace ; 20(12): 1981-1988, 2018 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-29688322

RESUMEN

Aims: To correlate dynamics in electrical conduction after transcatheter aortic valve implantation (TAVI) with need for permanent pacemaker implantation (PPM) and assess implications for early discharge. Methods and results: Daily electrocardiograms after TAVI were analysed for rhythm and conduction times and were correlated with PPM. Transcatheter aortic valve implantation was performed in 291 consecutive patients with three contemporary transcatheter heart valve designs: Medtronic CoreValve (n = 111), Edwards Sapien XT (n = 29) and Sapien 3 (n = 72), and Boston Lotus (n = 79). We considered two cohorts: (A) Patients with normal baseline conduction; and (B) patients with pre-existent conduction disturbances. Based on QRS dynamics, three patterns were discerned: stable normal QRS duration, transient QRS prolongation, and persistent QRS prolongation. In Cohort B, QRS dynamics did not correlate with PPM. In contrast, in Cohort A, QRS dynamics and PPM appeared highly correlated. Neither patients with stable normal QRS duration (0/47), nor patients with transient QRS prolongation required PPM (0/26). All PPMs occurred in patients with persistent QRS prolongation until discharge (27/85). Persistent QRS prolongation was typically seen with Lotus and CoreValve, whereas stable normal QRS duration was typically seen with Sapien XT and Sapien 3. Conclusion: Three distinct patterns of QRS dynamics can be discerned after TAVI and their predictive probabilities for PPM strongly relate to the baseline conduction status. Patients with normal conduction at baseline and stable QRS duration after TAVI are potentially eligible for early discharge.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Arritmias Cardíacas/terapia , Estimulación Cardíaca Artificial , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca , Tiempo de Internación , Marcapaso Artificial , Alta del Paciente , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Potenciales de Acción , Anciano , Anciano de 80 o más Años , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/fisiopatología , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiología , Arritmias Cardíacas/fisiopatología , Bases de Datos Factuales , Electrocardiografía , Femenino , Prótesis Valvulares Cardíacas , Hemodinámica , Humanos , Masculino , Diseño de Prótesis , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento
16.
JACC Cardiovasc Interv ; 11(2): 119-128, 2018 01 22.
Artículo en Inglés | MEDLINE | ID: mdl-29348006

RESUMEN

OBJECTIVES: The aim of this post hoc analysis from the RESPOND (Repositionable Lotus Valve System-Post-Market Evaluation of Real World Clinical Outcomes) post-market study was to assess the final implantation depth on the contrast aortogram after Lotus valve (Boston Scientific, Marlborough, Massachusetts) transcatheter aortic valve replacement (TAVR) and to correlate with permanent pacemaker implantation (PPI) and paravalvular leak (PVL). BACKGROUND: Contrast aortography allows for the assessment of implantation depth and PVL during and after TAVR. Previous reports suggested an association between final device position and rates of PPI and PVL. METHODS: The RESPOND study was a prospective, open-label, single-arm study in 41 centers evaluating outcomes after Lotus TAVR in routine clinical practice. Aortograms were collected at the Erasmus Medical Center and analyzed by researchers who were blinded to clinical outcomes. The primary analysis correlated implantation depth with PPI and PVL and required aortograms in a coaxial projection. The relation between implantation depth and need for PPI was assessed by multivariate logistic regression, adjusting for pre-defined confounders. A secondary analysis compared PVL analysis by contrast aortography with transthoracic echocardiography (TTE) performed by the independent core laboratory. RESULTS: A total of 724 angiographic studies were included in this analysis. Mean Lotus implantation depth was 6.67 ± 2.19 mm. The overall PPI rate was 35%. PPI rate was lower with shallow implants (<6.5 mm: 21% vs. ≥6.5 mm: 41%; p < 0.001). After adjustment for confounders, implantation depth independently predicted need for PPI (odds ratio per 1-mm increment in depth: 1.200; 95% confidence interval: 1.091 to 1.319; p = 0.002). More than trivial PVL was present in 23% by contrast aortography and in 8% by TTE. Implantation depth was not correlated with PVL by contrast aortography or TTE (p = 0.342 and p = 0.149, respectively). PVL grading by contrast aortography and TTE was concordant in 77%. CONCLUSIONS: In this post hoc analysis of the RESPOND study PPI was highly correlated with implantation depth, whereas PVL was not. Higher Lotus implantation may reduce need for PPI.


Asunto(s)
Válvula Aórtica/cirugía , Aortografía , Medios de Contraste/administración & dosificación , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiología , Arritmias Cardíacas/terapia , Estimulación Cardíaca Artificial , Europa (Continente) , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Vigilancia de Productos Comercializados , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
17.
Eur Heart J Cardiovasc Imaging ; 19(2): 157-167, 2018 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-28064153

RESUMEN

Aims: The Lotus and SAPIEN3 are second-generation transcatheter heart valves, which are designed to minimize paravalvular aortic regurgitation (PAR) after transcatheter aortic valve replacement (TAVR). We sought to compare both devices for valve performance and with emphasis on PAR by independent core laboratory analysis. Methods and results: A total of 162 (79 Lotus and 83 SAPIEN3) consecutive patients (51% female, 80 ± 8 years, Logistic EuroSCORE 14.8 ± 9.4%) who underwent TAVR because of aortic stenosis were included. Patients with aortic valve-in-valve treatment were excluded. Pre-discharge echocardiograms were analysed by an independent core laboratory using the Valve Academic Research Consortium 2 criteria. There were no differences in baseline and procedural characteristics, except for a larger aortic annulus and sizing indices in SAPIEN3-treated patients and frequency of post-dilatation (0% in Lotus and 13.1% in SAPIEN3). Both valves have similar mean residual gradient, indexed effective orifice area and Doppler velocity index when adjusted to valve size. The frequency of mild (13.9% vs. 31.3%) and at least moderate (1.3% vs. 3.6%) PAR was less after Lotus than after SAPIEN3 implantation (P = 0.02). Multi-slice computed tomography-based annulus and left ventricular outflow tract diameters, calcification and percentage of oversizing were not different between those with or without mild or more PAR. On multivariate analysis, the use of Lotus valve was associated with less (odds ratio OR, 0.41, P = 0.03) occurrence of PAR. Conclusion: Overall, haemodynamic performance was comparable between the Lotus and SAPIEN3 valves. Lotus valve required less oversizing and was associated with less PAR than SAPIEN3.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Tomografía Computarizada Multidetector/métodos , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estudios de Cohortes , Ecocardiografía Doppler/métodos , Análisis de Falla de Equipo , Femenino , Hemodinámica/fisiología , Humanos , Masculino , Análisis Multivariante , Pronóstico , Falla de Prótesis , Estudios Retrospectivos , Medición de Riesgo , Estadísticas no Paramétricas , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
18.
Catheter Cardiovasc Interv ; 91(4): 790-797, 2018 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-28895285

RESUMEN

OBJECTIVES: To evaluate the value of left vertebral artery filter protection in addition to the current filter-based embolic protection technology to achieve complete cerebral protection during TAVR. BACKGROUND: The occurrence of cerebrovascular events after transcatheter aortic valve replacement (TAVR) has fueled concern for its potential application in younger patients with longer life expectancy. Transcatheter cerebral embolic protection (TCEP) devices may limit periprocedural cerebrovascular events by preventing macro and micro-embolization to the brain. Conventional filter-based TCEP devices cover three extracranial contributories to the brain, yet leave the left vertebral artery unprotected. METHODS: Patients underwent TAVR with complete TCEP. A dual-filter system was deployed in the brachiocephalic trunk and left common carotid artery with an additional single filter in the left vertebral artery. After TAVR all filters were retrieved and sent for histopathological evaluation by an experienced pathologist. RESULTS: Eleven patients received a dual-filter system and nine of them received an additional left vertebral filter. In the remaining two patients, the left vertebral filter could not be deployed. No periprocedural strokes occurred. We found debris in all filters, consisting of thrombus, tissue derived debris, and foreign body material. The left vertebral filter contained debris in an equal amount of patients as the Sentinel filters. The size of the captured particles was similar between all filters. CONCLUSIONS: The left vertebral artery is an important entry route for embolic material to the brain during TAVR. Selective filter protection of the left vertebral artery revealed embolic debris in all patients. The clinical value of complete filter-based TCEP during TAVR warrants further research.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Tronco Braquiocefálico , Arteria Carótida Común , Dispositivos de Protección Embólica , Prótesis Valvulares Cardíacas , Embolia Intracraneal/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Arteria Vertebral , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Tronco Braquiocefálico/diagnóstico por imagen , Tronco Braquiocefálico/patología , Arteria Carótida Común/diagnóstico por imagen , Arteria Carótida Común/patología , Angiografía por Tomografía Computarizada , Femenino , Humanos , Embolia Intracraneal/diagnóstico por imagen , Embolia Intracraneal/etiología , Embolia Intracraneal/patología , Masculino , Estudios Prospectivos , Diseño de Prótesis , Factores Protectores , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Arteria Vertebral/diagnóstico por imagen , Arteria Vertebral/patología
19.
J Am Coll Cardiol ; 69(19): 2383-2392, 2017 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-28494976

RESUMEN

BACKGROUND: Left ventricular (LV) systolic dysfunction and moderate aortic stenosis (AS) are more frequent with advancing age and often coexist. Afterload reduction is the mainstay of pharmacological treatment of heart failure (HF). Aortic valve replacement (AVR) is only formally indicated for symptomatic severe AS. OBJECTIVES: This study sought to determine the clinical outcome of patients with concomitant moderate AS and LV systolic dysfunction. METHODS: Echocardiographic and clinical data of patients with moderate AS and LV systolic dysfunction between 2010 and 2015 from 4 large academic institutions were retrospectively analyzed. Moderate AS was defined as aortic valve area between 1.0 and 1.5 cm2 and LV systolic dysfunction defined as LV ejection fraction <50%. The primary endpoint was a composite of all-cause death, AVR, and HF hospitalization. RESULTS: A total of 305 patients (mean age 73 ± 11 years; 75% male) were included. The majority were symptomatic at the time of index echocardiogram (New York Heart Association [NYHA] functional class II: 42%; NYHA functional class III: 28%; and NYHA functional class IV: 4%). Ischemic heart disease was present in 72% of patients. At 4-year follow-up, the primary composite endpoint occurred in 61%. The main predictors for the primary endpoint were male sex (p = 0.022), NYHA functional class III or IV (p < 0.001), and peak aortic jet velocity (p < 0.001). The rate of the composite of all-cause death or HF hospitalization was 48%, rate of all-cause death was 36%, and rate of HF hospitalization was 27%. AVR occurred in 24% of patients. CONCLUSIONS: Patients with concomitant moderate AS and LV systolic dysfunction are at high risk for clinical events. Further studies are needed to determine if earlier AVR in these patients might improve clinical outcome.


Asunto(s)
Estenosis de la Válvula Aórtica/complicaciones , Disfunción Ventricular Izquierda/complicaciones , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Ecocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Admisión del Paciente/estadística & datos numéricos , Estudios Retrospectivos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/mortalidad
20.
Ultrasound Med Biol ; 43(8): 1596-1606, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-28545859

RESUMEN

The propagation velocity of shear waves relates to tissue stiffness. We prove that a regular clinical cardiac ultrasound system can determine shear wave velocity with a conventional unmodified tissue Doppler imaging (TDI) application. The investigation was performed on five tissue phantoms with different stiffness using a research platform capable of inducing and tracking shear waves and a clinical cardiac system (Philips iE33, achieving frame rates of 400-700 Hz in TDI by tuning the normal system settings). We also tested the technique in vivo on a normal individual and on typical pathologies modifying the consistency of the left ventricular wall. The research platform scanner was used as reference. Shear wave velocities measured with TDI on the clinical cardiac system were very close to those measured by the research platform scanner. The mean difference between the clinical and research systems was 0.18 ± 0.22 m/s, and the limits of agreement, from -0.27 to +0.63 m/s. In vivo, the velocity of the wave induced by aortic valve closure in the interventricular septum increased in patients with expected increased wall stiffness.


Asunto(s)
Ecocardiografía Doppler/métodos , Diagnóstico por Imagen de Elasticidad/métodos , Corazón/diagnóstico por imagen , Corazón/fisiopatología , Procesamiento de Imagen Asistido por Computador/métodos , Fantasmas de Imagen , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS