Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Int J Cardiovasc Imaging ; 40(7): 1511-1524, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38819601

RESUMEN

4D-flow MRI is a promising technique for assessing vessel hemodynamics. However, its utilization is currently limited by the lack of reference values, particularly for pulmonary vessels. In this work, we have analysed flow and velocity in the pulmonary trunk (PT), left and right pulmonary arteries (LPA and RPA, respectively) in Landrace pigs at both rest and stress through the software MEVISFlow. Nine healthy Landrace pigs were acutely instrumented closed-chest and transported to the CMR facility for evaluation. After rest measurements, dobutamine was administered to achieve a 25% increase in heart rate compared to rest. 4D-flow MRI images have been analysed through MEVISFlow by two independent observers. Inter- and intra-observer reproducibility was quantified using intraclass correlation coefficient. A significant difference between rest and stress regarding flow and velocity in all the pulmonary vessels was observed. Mean flow increased 55% in PT, 75% in LPA and 40% in RPA. Mean peak velocity increased 55% in PT, 75% in LPA and 66% in RPA. A good-to-excellent reproducibility was observed in rest and stress for flow measurements in all three arteries. An excellent reproducibility for velocity was found in PT at rest and stress, a good one for LPA and RPA at rest, while poor reproducibility was found at stress. The current study showed that pulmonary flow and velocity assessed through 4D-flow MRI follow the physiological alterations during cardiac cycle and after stress induced by dobutamine. A clinical translation to assess pulmonary diseases with 4D-flow MRI under stress conditions needs investigation.


Asunto(s)
Dobutamina , Valor Predictivo de las Pruebas , Arteria Pulmonar , Circulación Pulmonar , Sus scrofa , Animales , Reproducibilidad de los Resultados , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/fisiopatología , Dobutamina/administración & dosificación , Dobutamina/farmacología , Velocidad del Flujo Sanguíneo , Variaciones Dependientes del Observador , Imagen de Perfusión/métodos , Hemodinámica , Interpretación de Imagen Asistida por Computador , Modelos Animales , Imagen por Resonancia Magnética , Femenino , Angiografía por Resonancia Magnética , Frecuencia Cardíaca
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA