Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Cell Rep Methods ; : 100795, 2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38861989

RESUMEN

The polyclonal repertoire of circulating antibodies potentially holds valuable information about an individual's humoral immune state. While bottom-up proteomics is well suited for serum proteomics, the vast number of antibodies and dynamic range of serum challenge this analysis. To acquire the serum proteome more comprehensively, we incorporated high-field asymmetric waveform ion-mobility spectrometry (FAIMS) or two-dimensional chromatography into standard trypsin-based bottom-up proteomics. Thereby, the number of variable region (VR)-related spectra increased 1.7-fold with FAIMS and 10-fold with chromatography fractionation. To match antibody VRs to spectra, we combined de novo searching and BLAST alignment. Validation of this approach showed that, as peptide length increased, the de novo accuracy decreased and BLAST performance increased. Through in silico calculations on antibody repository sequences, we determined the uniqueness of tryptic VR peptides and their suitability as antibody surrogate. Approximately one-third of these peptides were unique, and about one-third of all antibodies contained at least one unique peptide.

2.
Clin Chem Lab Med ; 2024 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-38332688

RESUMEN

OBJECTIVES: Multiple myeloma (MM) is a plasma cell malignancy characterized by a monoclonal expansion of plasma cells that secrete a characteristic M-protein. This M-protein is crucial for diagnosis and monitoring of MM in the blood of patients. Recent evidence has emerged suggesting that N-glycosylation of the M-protein variable (Fab) region contributes to M-protein pathogenicity, and that it is a risk factor for disease progression of plasma cell disorders. Current methodologies lack the specificity to provide a site-specific glycoprofile of the Fab regions of M-proteins. Here, we introduce a novel glycoproteogenomics method that allows detailed M-protein glycoprofiling by integrating patient specific Fab region sequences (genomics) with glycoprofiling by glycoproteomics. METHODS: Glycoproteogenomics was used for the detailed analysis of de novo N-glycosylation sites of M-proteins. First, Genomic analysis of the M-protein variable region was used to identify de novo N-glycosylation sites. Subsequently glycopeptide analysis with LC-MS/MS was used for detailed analysis of the M-protein glycan sites. RESULTS: Genomic analysis uncovered a more than two-fold increase in the Fab Light Chain N-glycosylation of M-proteins of patients with Multiple Myeloma compared to Fab Light Chain N-glycosylation of polyclonal antibodies from healthy individuals. Subsequent glycoproteogenomics analysis of 41 patients enrolled in the IFM 2009 clinical trial revealed that the majority of the Fab N-glycosylation sites were fully occupied with complex type glycans, distinguishable from Fc region glycans due to high levels of sialylation, fucosylation and bisecting structures. CONCLUSIONS: Together, glycoproteogenomics is a powerful tool to study de novo Fab N-glycosylation in plasma cell dyscrasias.

3.
Clin Chem Lab Med ; 62(3): 540-550, 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-37823394

RESUMEN

OBJECTIVES: Minimal residual disease status in multiple myeloma is an important prognostic biomarker. Recently, personalized blood-based targeted mass spectrometry (MS-MRD) was shown to provide a sensitive and minimally invasive alternative to measure minimal residual disease. However, quantification of MS-MRD requires a unique calibrator for each patient. The use of patient-specific stable isotope labelled (SIL) peptides is relatively costly and time-consuming, thus hindering clinical implementation. Here, we introduce a simplification of MS-MRD by using an off-the-shelf calibrator. METHODS: SILuMAB-based MS-MRD was performed by spiking a monoclonal stable isotope labeled IgG, SILuMAB-K1, in the patient serum. The abundance of both M-protein-specific peptides and SILuMAB-specific peptides were monitored by mass spectrometry. The relative ratio between M-protein peptides and SILuMAB peptides allowed for M-protein quantification. We assessed linearity, sensitivity and reproducibility of SILuMAB-based MS-MRD in longitudinally collected sera from the IFM-2009 clinical trial. RESULTS: A linear dynamic range was achieved of over 5 log scales, allowing for M-protein quantification down to 0.001 g/L. The inter-assay CV of SILuMAB-based MS-MRD was on average 11 %. Excellent concordance between SIL- and SILuMAB-based MS-MRD was shown (R2>0.985). Additionally, signal intensity of spiked SILuMAB can be used for quality control purpose to assess system performance and incomplete SILuMAB digestion can be used as quality control for sample preparation. CONCLUSIONS: Compared to SIL peptides, SILuMAB-based MS-MRD improves the reproducibility, turn-around-times and cost-efficacy of MS-MRD without diminishing its sensitivity and specificity. Furthermore, SILuMAB can be used as a MS-MRD quality control tool to monitor sample preparation efficacy and assay performance.


Asunto(s)
Mieloma Múltiple , Humanos , Mieloma Múltiple/diagnóstico , Neoplasia Residual , Reproducibilidad de los Resultados , Espectrometría de Masas/métodos , Péptidos , Isótopos
4.
Crit Rev Clin Lab Sci ; 60(7): 518-534, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37232394

RESUMEN

Multiple myeloma (MM) is characterized by the clonal expansion of plasma cells and the excretion of a monoclonal immunoglobulin (M-protein), or fragments thereof. This biomarker plays a key role in the diagnosis and monitoring of MM. Although there is currently no cure for MM, novel treatment modalities such as bispecific antibodies and CAR T-cell therapies have led to substantial improvement in survival. With the introduction of several classes of effective drugs, an increasing percentage of patients achieve a complete response. This poses new challenges to traditional electrophoretic and immunochemical M-protein diagnostics because these methods lack sensitivity to monitor minimal residual disease (MRD). In 2016, the International Myeloma Working Group (IMWG) expanded their disease response criteria with bone marrow-based MRD assessment using flow cytometry or next-generation sequencing in combination with imaging-based disease monitoring of extramedullary disease. MRD status is an important independent prognostic marker and its potential as a surrogate endpoint for progression-free survival is currently being studied. In addition, numerous clinical trials are investigating the added clinical value of MRD-guided therapy decisions in individual patients. Because of these novel clinical applications, repeated MRD evaluation is becoming common practice in clinical trials as well as in the management of patients outside clinical trials. In response to this, novel mass spectrometric methods that have been developed for blood-based MRD monitoring represent attractive minimally invasive alternatives to bone marrow-based MRD evaluation. This paves the way for dynamic MRD monitoring to allow the detection of early disease relapse, which may prove to be a crucial factor in facilitating future clinical implementation of MRD-guided therapy. This review provides an overview of state-of-the-art of MRD monitoring, describes new developments and applications of blood-based MRD monitoring, and suggests future directions for its successful integration into the clinical management of MM patients.

5.
Eur J Neurosci ; 56(12): 6258-6268, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36300719

RESUMEN

To compare cell adhesion molecules levels in cerebrospinal fluid (CSF) between Zika virus (ZIKV)-exposed neonates with/without microcephaly (cases) and controls, 16 neonates (cases), 8 (50%) with and 8 (50%) without microcephaly, who underwent lumbar puncture (LP) during the ZIKV epidemic (2015-2016) were included. All mothers reported ZIKV clinical symptoms during gestation, all neonates presented with congenital infection findings, and other congenital infections were ruled out. Fourteen control neonates underwent LP in the same laboratory (2017-2018). Five cell adhesion proteins were measured in the CSF using mass spectrometry. Neurexin-1 (3.50 [2.00-4.00] vs. 7.5 [5.00-10.25], P = 0.001), neurexin-3 (0.00 [0.00-0.00] vs. 3.00 [1.50-4.00], P = 0.001) and neural cell adhesion molecule 2 (NCAM2) (0.00 [0.00-0.75] vs. 1.00 [1.00-2.00], P = 0.001) were significantly lower in microcephalic and non-microcephalic cases than in controls. When these two sub-groups of prenatally ZIKA-exposed children were compared to controls separately, the same results were found. When cases with and without microcephaly were compared, no difference was found. Neurexin-3 (18.8% vs. 78.6%, P = 0.001) and NCAM2 (25.0% vs. 85.7%, P = 0.001) were less frequently found among the cases. A positive correlation was found between cephalic perimeter and levels of these two proteins. Neurexin-2 and neurexin-2b presented no significant differences. Levels of three cell adhesion proteins were significantly lower in CSF of neonates exposed to ZIKV before birth than in controls, irrespective of presence of congenital microcephaly. Moreover, the smaller the cephalic perimeter, the lower CSF cell adhesion protein levels. These findings suggest that low CSF levels of neurexin-1, neurexin-3 and NCAM2 may reflect the effects of ZIKV on foetal brain development.


Asunto(s)
Microcefalia , Complicaciones Infecciosas del Embarazo , Infección por el Virus Zika , Virus Zika , Recién Nacido , Embarazo , Femenino , Niño , Humanos , Infección por el Virus Zika/diagnóstico , Infección por el Virus Zika/epidemiología , Microcefalia/epidemiología , Estudios de Casos y Controles , Adhesión Celular , Complicaciones Infecciosas del Embarazo/epidemiología , Moléculas de Adhesión Celular , Moléculas de Adhesión de Célula Nerviosa
7.
Anal Chem ; 94(7): 3120-3125, 2022 02 22.
Artículo en Inglés | MEDLINE | ID: mdl-35119270

RESUMEN

Electrochemical reduction of intermolecular disulfide bridges has previously been demonstrated in immunoglobulins but failed to achieve reduction of intramolecular bonds. We now report an improved method that achieves the full reduction of both intermolecular and intramolecular disulfide bridges in a set of monoclonal antibodies based on their intact mass and on MS/MS analysis. The system uses an online electrochemical flow cell positioned online between a chromatography system and a mass spectrometer to give direct information on pairs of heavy and light chains in an antibody. The complete reduction of the intramolecular disulfide bridges is important, as the redox state affects the intact mass of the antibody chain. Disulfide bonds also hamper MS/MS fragmentation of protein chains and thus limit the confirmation of the amino acid sequence of the protein of interest. The improved electrochemical system and associated protocols can simplify sample processing prior to analysis, as chemical reduction is not required. Also, it opens up new possibilities in the top-down mass spectrometry analysis of samples containing complex biomolecules with inter- and intramolecular disulfide bridges.


Asunto(s)
Disulfuros , Espectrometría de Masas en Tándem , Secuencia de Aminoácidos , Anticuerpos Monoclonales/análisis , Disulfuros/química , Oxidación-Reducción
8.
Clin Chem ; 67(12): 1689-1698, 2021 11 26.
Artículo en Inglés | MEDLINE | ID: mdl-34643690

RESUMEN

BACKGROUND: Minimal residual disease (MRD) status assessed on bone marrow aspirates is a major prognostic biomarker in multiple myeloma (MM). In this study we evaluated blood-based targeted mass spectrometry (MS-MRD) as a sensitive, minimally invasive alternative to measure MM disease activity. METHODS: Therapy response of 41 MM patients in the IFM-2009 clinical trial (NCT01191060) was assessed with MS-MRD on frozen sera and compared to routine state-of-the-art monoclonal protein (M-protein) diagnostics and next-generation sequencing (NGS-MRD) at 2 time points. RESULTS: In all 41 patients we were able to identify clonotypic M-protein-specific peptides and perform serum-based MS-MRD measurements. MS-MRD is significantly more sensitive to detect M-protein compared to either electrophoretic M-protein diagnostics or serum free light chain analysis. The concordance between NGS-MRD and MS-MRD status in 81 paired bone marrow/sera samples was 79%. The 50% progression-free survival (PFS) was identical (49 months) for patients who were either NGS-positive or MS-positive directly after maintenance treatment. The 50% PFS was 69 and 89 months for NGS-negative and MS-negative patients, respectively. The longest 50% PFS (96 months) was observed in patients who were MRD-negative for both methods. MS-MRD relapse during maintenance treatment was significantly correlated to poor PFS (P < 0.0001). CONCLUSIONS: Our data indicate proof-of-principle that MS-MRD evaluation in blood is a feasible, patient friendly alternative to NGS-MRD assessed on bone marrow. Clinical validation of the prognostic value of MS-MRD and its complementary value in MRD-evaluation of patients with MM is warranted in an independent larger cohort.


Asunto(s)
Mieloma Múltiple , Médula Ósea/metabolismo , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Humanos , Espectrometría de Masas , Mieloma Múltiple/diagnóstico , Mieloma Múltiple/tratamiento farmacológico , Mieloma Múltiple/genética , Neoplasia Residual/diagnóstico
9.
Clin Chem ; 67(6): 867-875, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-33709101

RESUMEN

BACKGROUND: Due to improved treatment, more patients with multiple myeloma (MM) reach a state of minimal residual disease (MRD). Different strategies for MM MRD monitoring include flow cytometry, allele-specific oligonucleotide-quantitative PCR, next-generation sequencing, and mass spectrometry (MS). The last 3 methods rely on the presence and the stability of a unique immunoglobulin fingerprint derived from the clonal plasma cell population. For MS-MRD monitoring it is imperative that MS-compatible clonotypic M-protein peptides are identified. To support implementation of molecular MRD techniques, we studied the presence and stability of these clonotypic features in the CoMMpass database. METHODS: An analysis pipeline based on MiXCR and HIGH-VQUEST was constructed to identify clonal molecular fingerprints and their clonotypic peptides based on transcriptomic datasets. To determine the stability of the clonal fingerprints, we compared the clonal fingerprints during disease progression for each patient. RESULTS: The analysis pipeline to establish the clonal fingerprint and MS-suitable clonotypic peptides was successfully validated in MM cell lines. In a cohort of 609 patients with MM, we demonstrated that the most abundant clone harbored a unique clonal molecular fingerprint and that multiple unique clonotypic peptides compatible with MS measurements could be identified for all patients. Furthermore, the clonal immunoglobulin gene fingerprints of both the light and heavy chain remained stable during MM disease progression. CONCLUSIONS: Our data support the use of the clonal immunoglobulin gene fingerprints in patients with MM as a suitable MRD target for MS-MRD analyses.


Asunto(s)
Genes de Inmunoglobulinas/fisiología , Mieloma Múltiple , Péptidos/química , Biomarcadores , Progresión de la Enfermedad , Humanos , Mieloma Múltiple/diagnóstico , Mieloma Múltiple/genética , Neoplasia Residual/genética , Péptidos/genética
10.
Sci Rep ; 10(1): 22292, 2020 12 18.
Artículo en Inglés | MEDLINE | ID: mdl-33339858

RESUMEN

New therapies are an urgent medical need in all breast cancer subgroups. Metabotropic glutamate receptor 1 (mGluR1) is suggested as a potential new molecular target. We examined the prevalence mGluR1 expression in different clinically relevant breast cancer subgroups and determined its association with prognosis. In this retrospective cohort, 394 consecutive primary breast cancer tissues were incorporated into a tissue microarray and immunohistochemically stained for mGluR1. The prevalence of mGluR1 protein expression in different breast cancer subgroups was evaluated and correlated with metastasis-free survival (MFS) and overall survival (OS). In total, 56% (n = 219) breast cancer tissues had mGluR1 expression. In estrogen receptor (ER)-negative tumors, 31% (n = 18/58) had mGluR1 expression that was significantly associated with MFS (HR 5.00, 95% CI 1.03-24.35, p = 0.046) in multivariate analysis, independently from other prognostic factors. Of the 44 triple-negative breast cancer (TNBC), 25% (n = 11) expressed mGluR1. mGluR1 expression in TNBC was significantly associated with shorter MFS (HR 8.60, 95% CI 1.06-20.39, p = 0.044) and with poor OS (HR 16.07, 95% CI 1.16-223.10, p = 0.039). In conclusion, mGluR1 is frequently expressed in breast cancer. In ER-negative breast cancer and in TNBC mGluR1 protein expression is an unfavorable prognostic marker. This study provides rationale to explore mGluR1 as a novel target for breast cancer treatment, especially for the more aggressive TNBC.


Asunto(s)
Neoplasias de la Mama/genética , Receptores de Estrógenos/genética , Receptores de Glutamato Metabotrópico/genética , Neoplasias de la Mama Triple Negativas/genética , Adulto , Biomarcadores de Tumor/genética , Neoplasias de la Mama/epidemiología , Neoplasias de la Mama/patología , Supervivencia sin Enfermedad , Femenino , Regulación Neoplásica de la Expresión Génica/genética , Humanos , Persona de Mediana Edad , Pronóstico , Receptor ErbB-2/genética , Estudios Retrospectivos , Neoplasias de la Mama Triple Negativas/epidemiología , Neoplasias de la Mama Triple Negativas/patología
11.
J Infect ; 80(4): 419-425, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31981639

RESUMEN

OBJECTIVE: To compare immunoglobulin levels in cerebrospinal fluid (CSF) of neonates exposed to Zika virus (ZIKV) during foetal life (cases) with levels in CSF of control neonates. METHODS: We identified 16 neonates who underwent lumbar puncture (LP), during the ZIKV epidemic (December/2015 to March/2016) whose mothers reported ZIKV clinical symptoms during gestation (cases). Congenital microcephaly was defined as head circumference ≤31.9 cm (boys) and ≤31.5 cm (girls) for term neonates, or ≤2 standard deviations below the mean for premature (<37 weeks) neonates. Subsequently, we identified neonates who underwent LP in the same lab and fulfilled criteria to be controls: age ≤4 days, CSF white blood cell count ≤8/mm3, CSF protein ≤132 mg/dL, CSF red blood cell count ≤1,000/mm3, neither central nervous system illness, nor congenital infection, nor microcephaly. CSF immunoglobulin concentrations were measured by mass spectrometry. RESULTS: 13 controls were included. IgM, IgA, IgG, IgK, and IgL were significantly higher among cases (p < 0.001). Eight (50%) ZIKV exposed infants had congenital microcephaly. These showed the strongest immunoglobulin elevation of the IgM and IgA classes. CONCLUSION: Neonates exposed to ZIKV infection during gestation present with elevated distinct immunoglobulins in CSF, both in cases that developed microcephaly and in cases that did not.


Asunto(s)
Epidemias , Microcefalia , Complicaciones Infecciosas del Embarazo , Infección por el Virus Zika , Virus Zika , Femenino , Humanos , Inmunoglobulinas , Lactante , Recién Nacido , Masculino , Microcefalia/epidemiología , Embarazo , Complicaciones Infecciosas del Embarazo/epidemiología , Infección por el Virus Zika/epidemiología
12.
J Proteome Res ; 19(7): 2845-2853, 2020 07 02.
Artículo en Inglés | MEDLINE | ID: mdl-31895568

RESUMEN

Serum protein electrophoresis (SPE) and immunofixation electrophoresis (IFE) are standard tools for multiple myeloma (MM) routine diagnostics. M-protein is a biomarker for MM that can be quantified with SPE and characterized with IFE. We have investigated combining SPE/IFE with targeted mass spectrometry (MS) to detect and quantify the M-protein. SPE-MS assay offers the possibility to detect M-protein with higher sensitivity than SPE/IFE, which could lead to better analysis of minimal residual disease in clinical laboratories. In addition, analysis of archived SPE gels could be used for retrospective MM studies. We have investigated two different approaches of measuring M-protein and therapeutic monoclonal antibodies (t-mAbs) from SPE/IFE gels. After extracting proteotypic peptides from the gel, they can be quantified using stable isotope labeled (SIL) peptides and measured by Orbitrap mass spectrometry. Alternatively, extracted peptides can be labeled with tandem mass tags (TMT). Both approaches are not hampered by the presence of t-mAbs. Using SIL peptides, limit of detection of the M-protein is approximately 100-fold better than with routine SPE/IFE. Using TMT labeling, M-protein can be compared in different samples from the same patient. We have successfully measured M-protein proteotypic peptides extracted from the SPE/IFE gels utilizing SIL peptides and TMT.


Asunto(s)
Flujo de Trabajo , Electroforesis de las Proteínas Sanguíneas , Humanos , Inmunoelectroforesis , Espectrometría de Masas , Estudios Retrospectivos
13.
J Proteome Res ; 17(3): 1326-1333, 2018 03 02.
Artículo en Inglés | MEDLINE | ID: mdl-29424538

RESUMEN

M-protein diagnostics can be compromised for patients receiving therapeutic monoclonal antibodies as treatment in multiple myeloma. Conventional techniques are often not able to distinguish between M-proteins and therapeutic monoclonal antibodies administered to the patient. This may prevent correct response assessment and can lead to overtreatment. We have developed a serum-based targeted mass-spectrometry assay to detect M-proteins, even in the presence of three therapeutic monoclonal antibodies (daratumumab, ipilimumab, and nivolumab). This assay can target proteotypic M-protein peptides as well as unique peptides derived from therapeutic monoclonal antibodies. We address the sensitivity in M-protein diagnostics and show that our mass-spectrometry assay is more than two orders of magnitude more sensitive than conventional M-protein diagnostics. The use of stable isotope-labeled peptides allows absolute quantification of the M-protein and increases the potential of assay standardization across multiple laboratories. Finally, we discuss the position of mass-spectrometry assays in monitoring minimal residual disease in multiple myeloma, which is currently dominated by molecular techniques based on plasma cell assessment that requires invasive bone marrow aspirations or biopsies.


Asunto(s)
Bioensayo , Biomarcadores de Tumor/sangre , Espectrometría de Masas/métodos , Mieloma Múltiple/diagnóstico , Proteínas de Mieloma/metabolismo , Secuencia de Aminoácidos , Anticuerpos Monoclonales/sangre , Anticuerpos Monoclonales/uso terapéutico , Antineoplásicos/sangre , Antineoplásicos/uso terapéutico , Biomarcadores de Tumor/genética , Biomarcadores de Tumor/inmunología , Expresión Génica , Humanos , Ipilimumab/sangre , Ipilimumab/uso terapéutico , Marcaje Isotópico/métodos , Mieloma Múltiple/sangre , Mieloma Múltiple/tratamiento farmacológico , Mieloma Múltiple/inmunología , Proteínas de Mieloma/genética , Proteínas de Mieloma/inmunología , Neoplasia Residual , Nivolumab , Péptidos/química , Péptidos/inmunología , Sensibilidad y Especificidad
14.
Front Immunol ; 8: 1286, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29085363

RESUMEN

The immune system produces a diverse repertoire of immunoglobulins in response to foreign antigens. During B-cell development, VDJ recombination and somatic mutations generate diversity, whereas selection processes remove it. Using both proteomic and NGS approaches, we characterized the immune repertoires in groups of rats after immunization with purified antigens. Proteomics and NGS data on the repertoire are in qualitative agreement, but did show quantitative differences that may relate to differences between the biological niches that were sampled for these approaches. Both methods contributed complementary information in the characterization of the immune repertoire. It was found that the immune repertoires resulting from each antigen had many similarities that allowed samples to cluster together, and that mutated immunoglobulin peptides were shared among animals with a response to the same antigen significantly more than for different antigens. However, the number of shared sequences decreased in a log-linear fashion relative to the number of animals that share them, which may affect future applications. A phylogenetic analysis on the NGS reads showed that reads from different individuals immunized with the same antigen populated distinct branches of the phylogram, an indication that the repertoire had converged. Also, similar mutation patterns were found in branches of the phylogenetic tree that were associated with antigen-specific immunoglobulins through proteomics data. Thus, data from different analysis methods and different experimental platforms show that the immunoglobulin repertoires of immunized animals have overlapping and converging features. With additional research, this may enable interesting applications in biotechnology and clinical diagnostics.

15.
Proteomics ; 17(23-24)2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29110399

RESUMEN

Despite high-resolution mass spectrometers are becoming accessible for more and more laboratories, tandem (MS/MS) mass spectra are still often collected at a low resolution. And even if acquired at a high resolution, software tools used for their processing do not tend to benefit from that in full, and an ability to specify a relative mass tolerance in this case often remains the only feature the respective algorithms take advantage of. We argue that a more efficient way to analyze high-resolution MS/MS spectra should be with methods more explicitly accounting for the precision level, and sustain this claim through demonstrating that a de novo sequencing framework originally developed for (high-resolution) top-down MS/MS data is perfectly suitable for processing high-resolution bottom-up datasets, even though a top-down like deconvolution performed as the first step will leave in many spectra at most a few peaks.


Asunto(s)
Algoritmos , Fragmentos de Péptidos/análisis , Proteínas/análisis , Proteómica/métodos , Análisis de Secuencia de Proteína/métodos , Espectrometría de Masas en Tándem/métodos , Animales , Bovinos , Pollos , Bases de Datos de Proteínas , Caballos , Programas Informáticos
16.
Bioinformatics ; 32(18): 2753-9, 2016 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-27187201

RESUMEN

MOTIVATION: Recent technological advances have made high-resolution mass spectrometers affordable to many laboratories, thus boosting rapid development of top-down mass spectrometry, and implying a need in efficient methods for analyzing this kind of data. RESULTS: We describe a method for analysis of protein samples from top-down tandem mass spectrometry data, which capitalizes on de novo sequencing of fragments of the proteins present in the sample. Our algorithm takes as input a set of de novo amino acid strings derived from the given mass spectra using the recently proposed Twister approach, and combines them into aggregated strings endowed with offsets. The former typically constitute accurate sequence fragments of sufficiently well-represented proteins from the sample being analyzed, while the latter indicate their location in the protein sequence, and also bear information on post-translational modifications and fragmentation patterns. AVAILABILITY AND IMPLEMENTATION: Freely available on the web at http://bioinf.spbau.ru/en/twister CONTACT: vyatkina@spbau.ru or ppevzner@ucsd.edu SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online.


Asunto(s)
Algoritmos , Secuencia de Aminoácidos , Proteínas , Análisis de Secuencia de Proteína , Procesamiento Proteico-Postraduccional , Espectrometría de Masas en Tándem
17.
Cancer Immunol Res ; 4(2): 165-72, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26659304

RESUMEN

The high mortality rate in lung cancer is largely attributable to late diagnosis. Case-control studies suggest that autoantibodies to the survivin protein are potential biomarkers for early diagnosis. We tested the hypothesis that sandwich ELISA can detect autoantibodies to survivin before radiologic diagnosis in patients with early-stage non-small cell lung cancer (NSCLC). Because previous studies assayed survivin autoantibodies with the direct antigen-coating ELISA (DAC-ELISA), we first compared that assay with the sandwich ELISA. Based on the more robust results from the sandwich ELISA, we used it to measure survivin autoantibodies in the serum of 100 individuals from a well-controlled population study [the Dutch-Belgian Lung Cancer Screening Trial (NELSON) trial] composed of current and former smokers (50 patients with NSCLC, both before and after diagnosis, and 50 matched, smoking-habit control subjects), and another 50 healthy nonsmoking control subjects. We found no difference in specific autoantibodies to survivin in NSCLC patients, although nonspecific median optical densities were 24% higher (P < 0.001) in both NSCLC patients and smokers, than in healthy nonsmokers. Finally, we confirmed the ELISA results with Western blot analysis of recombinant and endogenous survivin (HEK-293), which showed no anti-survivin reactivity in patient sera. We conclude that specific anti-survivin autoantibody reactivity is most likely not present in sera before or after diagnosis. Autoantibody studies benefit from a comparison to a well-controlled population, stratified for smoking habit.


Asunto(s)
Especificidad de Anticuerpos , Autoanticuerpos/inmunología , Proteínas Inhibidoras de la Apoptosis/inmunología , Neoplasias Pulmonares/inmunología , Fumar , Anciano , Autoanticuerpos/sangre , Biomarcadores de Tumor , Ensayo de Inmunoadsorción Enzimática , Femenino , Células HEK293 , Humanos , Neoplasias Pulmonares/sangre , Neoplasias Pulmonares/diagnóstico , Masculino , Persona de Mediana Edad , Survivin
18.
J Proteome Res ; 14(11): 4450-62, 2015 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-26412692

RESUMEN

De novo sequencing of proteins and peptides is one of the most important problems in mass spectrometry-driven proteomics. A variety of methods have been developed to accomplish this task from a set of bottom-up tandem (MS/MS) mass spectra. However, a more recently emerged top-down technology, now gaining more and more popularity, opens new perspectives for protein analysis and characterization, implying a need for efficient algorithms to process this kind of MS/MS data. Here, we describe a method that allows for the retrieval, from a set of top-down MS/MS spectra, of long and accurate sequence fragments of the proteins contained in the sample. To this end, we outline a strategy for generating high-quality sequence tags from top-down spectra, and introduce the concept of a T-Bruijn graph by adapting to the case of tags the notion of an A-Bruijn graph widely used in genomics. The output of the proposed approach represents the set of amino acid strings spelled out by optimal paths in the connected components of a T-Bruijn graph. We illustrate its performance on top-down data sets acquired from carbonic anhydrase 2 (CAH2) and the Fab region of alemtuzumab.


Asunto(s)
Algoritmos , Péptidos/aislamiento & purificación , Proteómica/estadística & datos numéricos , Análisis de Secuencia de Proteína/estadística & datos numéricos , Espectrometría de Masas en Tándem/estadística & datos numéricos , Alemtuzumab , Secuencia de Aminoácidos , Animales , Anticuerpos Monoclonales Humanizados/química , Anhidrasa Carbónica II/química , Bovinos , Bases de Datos de Proteínas , Humanos , Fragmentos Fab de Inmunoglobulinas/química , Datos de Secuencia Molecular , Péptidos/química , Proteómica/métodos , Coloración y Etiquetado/métodos
19.
Anal Chem ; 87(16): 8268-74, 2015 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-26168337

RESUMEN

Serum free light chain (sFLC) assays are well established in the diagnosis and monitoring of plasma cell disorders. However, current FLC immunoassays are subject to several analytical issues, which results in a lack of harmonized results. To facilitate sFLC standardization, we investigated the strengths and limitations of mass spectrometry as a novel technological platform for sFLC quantification. Stable isotope labeled reference peptides are added to serum samples for quantitation by selected reaction monitoring (SRM). The use of redundant peptide sets allows for quality control measures during data analysis. Measurements on serum provide information on intact immunoglobulins, but depletion of these intact molecules from the sera during sample processing permits the quantitation of sFLC. sFLC concentrations measured with SRM were comparable to those obtained by nephelometry and showed excellent linearity (r(2) > 0.99). In samples with high levels of sFLC, SRM data was more consistent with serum protein electrophoresis than nephelometric data and SRM is unaffected by antigen excess. The lower limits of quantitation were 3.8 and 2.7 mg/L for κ and λ sFLC. Errors due to polymorphic sequences were prevented by comparison of redundant peptide pairs. The application of stable isotope labeling combined with SRM can overcome many of the current potential analytical issues of sFLC analysis. We describe which hurdles still need to be taken to make SRM a robust and more accurate method for sFLC measurements.


Asunto(s)
Análisis Químico de la Sangre/métodos , Cadenas Ligeras de Inmunoglobulina/sangre , Espectrometría de Masas , Cromatografía Liquida , Humanos , Límite de Detección , Espectrometría de Masas/normas , Estándares de Referencia
20.
J Proteome Res ; 13(7): 3241-8, 2014 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-24874765

RESUMEN

There are two approaches for de novo protein sequencing: Edman degradation and mass spectrometry (MS). Existing MS-based methods characterize a novel protein by assembling tandem mass spectra of overlapping peptides generated from multiple proteolytic digestions of the protein. Because each tandem mass spectrum covers only a short peptide of the target protein, the key to high coverage protein sequencing is to find spectral pairs from overlapping peptides in order to assemble tandem mass spectra to long ones. However, overlapping regions of peptides may be too short to be confidently identified. High-resolution mass spectrometers have become accessible to many laboratories. These mass spectrometers are capable of analyzing molecules of large mass values, boosting the development of top-down MS. Top-down tandem mass spectra cover whole proteins. However, top-down tandem mass spectra, even combined, rarely provide full ion fragmentation coverage of a protein. We propose an algorithm, TBNovo, for de novo protein sequencing by combining top-down and bottom-up MS. In TBNovo, a top-down tandem mass spectrum is utilized as a scaffold, and bottom-up tandem mass spectra are aligned to the scaffold to increase sequence coverage. Experiments on data sets of two proteins showed that TBNovo achieved high sequence coverage and high sequence accuracy.


Asunto(s)
Mapeo Peptídico , Análisis de Secuencia de Proteína , Alemtuzumab , Algoritmos , Secuencia de Aminoácidos , Animales , Anticuerpos Monoclonales Humanizados/química , Anhidrasa Carbónica II/química , Bovinos , Datos de Secuencia Molecular , Espectrometría de Masas en Tándem/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...