Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Intervalo de año de publicación
1.
Braz. J. Pharm. Sci. (Online) ; 58: e20812, 2022. tab
Artículo en Inglés | LILACS | ID: biblio-1420439

RESUMEN

Abstract Depression plays an important role in non-adherence to medical recommendations. Fluoxetine is a first line of depression treatment. This study aimed to evaluate adherence to drug therapy in fluoxetine users by different methods. A cross-section study was conducted with 53 depressed patients on fluoxetine for at least six months. Drug therapy adherence was assessed by validated questionnaires [Brief Medication Questionnaire (BMQ) and Morisky-Green test (MG)] and by the blood concentration of fluoxetine and its active metabolite norfluoxetine. Blood samples were taken before the daily first dose of fluoxetine. The plasmatic concentration of fluoxetine and norfluoxetine indicated that 58.5% volunteers were within the recommended therapeutic range and thus considered adherent to drug therapy. However, questionnaires indicated a non-adherent majority: 41.5% patients had a high degree of adherence in MG and only 13.2% were adherent to pharmacological treatment in BMQ. Most fluoxetine users showed a plasma concentration of fluoxetine and norfluoxetine within the therapeutic range, despite the low adherence to the drug therapy evaluated by the questionnaires. Thus, we suggest that plasma levels of fluoxetine and norfluoxetine could be used as the main method to check adherence to treatment.


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Fluoxetina/análisis , Encuestas y Cuestionarios/estadística & datos numéricos , Depresión/diagnóstico
2.
Clin Biochem ; 52: 85-93, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28987790

RESUMEN

BACKGROUND: Therapeutic drug monitoring (TDM) of the widely prescribed antidepressant fluoxetine (FLU) is recommended in certain situations, such as occurrence of toxicity, inadequate response or suspect of poor adherence. Dried blood spot (DBS) sampling is an increasingly studied alternative for TDM, particularly for outpatients, due to its ease of collection and inherent stability. OBJECTIVES: The aim of this study was to develop and validate an LC-MS/MS assay for the simultaneous quantification of FLU and norfluoxetine (NFLU) in DBS. DESIGN AND METHODS: The assay is based on a liquid extraction of single DBS with 8mm of diameter, using FLU-D6 as the internal standard, followed by reversed phase separation in an Accucore® C18 column (100×2.1mm, 2.6µm). Mobile phase was composed of water and acetonitrile (gradient from 80:20 to 50:50, v/v), both containing formic acid 0.1%. The assay was validated and applied to 30 patients under FLU pharmacotherapy. RESULTS: The assay was linear in the range 10-750ngmL-1. Precision assays presented CV% of 3.13-9.61 and 3.54-7.99 for FLU and NFLU, respectively, and accuracy in the range of 97.98-110.44% and 100.25-105.8%. FLU and NFLU were stable at 25 and 45°C for 7days. The assay was evaluated in 30 patients under FLU treatment. Concentrations of both compounds were higher in DBS than in plasma, and the use of the multiplying factors 0.71 and 0.68 for FLU and NFLU, respectively, allowed acceptable estimation of plasma concentrations, with median prediction bias of -0.55 to 0.55% and mean differences of 0.4 to 2.2ngmL-1. CONCLUSIONS: The presented data support the clinical use of DBS for therapeutic drug monitoring of FLU.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Fluoxetina/análogos & derivados , Fluoxetina/análisis , Espectrometría de Masas en Tándem/métodos , Cromatografía Liquida/métodos , Pruebas con Sangre Seca/métodos , Monitoreo de Drogas/métodos , Fluoxetina/sangre , Hematócrito , Humanos , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...