1.
Arch Oral Biol ; 164: 105986, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38723421

RESUMEN

AIM: To evaluate the adhesion of mono and duospecies biofilm on a commercially available dental implant surface coated with hydroxyapatite nanoparticles (nanoHA). MATERIAL AND METHODS: Titanium discs were divided into two groups: double acid-etched (AE) and AE coated with nanoHA (NanoHA). Surface characteristics evaluated were morphology, topography, and wettability. Mono and duospecies biofilms of Streptococcus sanguinis (S. sanguinis) and Candida albicans (C. albicans) were formed. Discs were exposed to fetal bovine serum (FBS) to form the pellicle. Biofilm was growth in RPMI1640 medium with 10% FBS and 10% BHI medium for 6 h. Microbial viability was evaluated using colony-forming unit and metabolic activity by a colorimetric assay of the tetrazolium salt XTT. Biofilm architecture and organization were evaluated by confocal laser scanning microscopy (CLSM) and scanning electron microscopy (SEM). RESULTS: AE surface had more pores, while NanoHA had even nanoHA crystals distribution. Roughness was similar (AE: 0.59 ± 0.07 µm, NanoHA: 0.69 ± 0.18 µm), but wettability was different (AE: Θw= 81.79 ± 8.55°, NanoHA: Θw= 53.26 ± 11.86°; P = 0.01). NanoHA had lower S. sanguinis viability in monospecies biofilm (P = 0.007). Metabolic activity was similar among all biofilms. In SEM both surfaces on C. albicans biofilm show a similar distribution of hyphae in mono and duospecies biofilms. AE surface has more S. sanguinis than the NanoHA surface in the duospecies biofilm. CLSM showed a large proportion of live cells in all groups. CONCLUSIONS: The nanoHA surface reduced the adhesion of S. sanguinis biofilm but did not alter the adhesion of C. albicans or the biofilm formed by both species.


Asunto(s)
Biopelículas , Candida albicans , Implantes Dentales , Durapatita , Microscopía Confocal , Microscopía Electrónica de Rastreo , Nanopartículas , Streptococcus sanguis , Propiedades de Superficie , Titanio , Titanio/química , Titanio/farmacología , Candida albicans/efectos de los fármacos , Candida albicans/fisiología , Biopelículas/efectos de los fármacos , Durapatita/farmacología , Durapatita/química , Streptococcus sanguis/efectos de los fármacos , Nanopartículas/química , Implantes Dentales/microbiología , Técnicas In Vitro , Adhesión Bacteriana/efectos de los fármacos , Humectabilidad , Materiales Biocompatibles Revestidos/farmacología , Materiales Biocompatibles Revestidos/química , Grabado Ácido Dental , Viabilidad Microbiana/efectos de los fármacos
2.
Clin Oral Investig ; 28(6): 336, 2024 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-38795258

RESUMEN

OBJECTIVE: Stress distribution assessment by finite elements analysis in poly(etheretherketone) (PEEK) implant and abutment as retainers of single crowns in the anterior region. MATERIALS AND METHODS: Five 3D models were created, varying implant/abutment manufacturing materials: titanium (Ti), zirconia (Zr), pure PEEK (PEEKp), carbon fiber-reinforced PEEK (PEEKc), glass fiber-reinforced PEEK (PEEKg). A 50 N load was applied 30o off-axis at the incisal edge of the upper central incisor. The Von Mises stress (σvM) was evaluated on abutment, implant/screw, and minimum principal stress (σmin) and maximum shear stress (τmax) for cortical and cancellous bone. RESULTS: The abutment σvM lowest stress was observed in PEEKp group, being 70% lower than Ti and 74% than Zr. On the implant, PEEKp reduced 68% compared to Ti and a 71% to Zr. In the abutment screws, an increase of at least 33% was found in PEEKc compared to Ti, and of at least 81% to Zr. For cortical bone, the highest τmax values were in the PEEKp group, and a slight increase in stress was observed compared to all PEEK groups with Ti and Zr. For σmin, the highest stress was found in the PEEKc. Stress increased at least 7% in cancellous bone for all PEEK groups. CONCLUSION: Abutments and implants made by PEEKc concentrate less σvM stress, transmitting greater stress to the cortical and medullary bone. CLINICAL RELEVANCE: The best stress distribution in PEEKc components may contribute to decreased stress shielding; in vitro and in vivo research is recommended to investigate this.


Asunto(s)
Benzofenonas , Coronas , Pilares Dentales , Análisis del Estrés Dental , Análisis de Elementos Finitos , Cetonas , Ensayo de Materiales , Polietilenglicoles , Polímeros , Titanio , Circonio , Cetonas/química , Polietilenglicoles/química , Humanos , Circonio/química , Titanio/química , Fibra de Carbono/química , Diseño de Implante Dental-Pilar , Incisivo , Materiales Dentales/química , Implantes Dentales de Diente Único , Hueso Cortical , Vidrio/química , Diseño de Prótesis Dental
3.
J Prosthet Dent ; 2023 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-36841707

RESUMEN

STATEMENT OF PROBLEM: Rehabilitation with wide-diameter reduced-length implants has become popular for patients with minimal vertical bone. However, a consensus on the benefits of this approach is lacking. PURPOSE: The purpose of this systematic review with meta-analysis was to evaluate the influence of wide compared with regular diameter on the clinical performance of short (<10 mm) and extrashort (≤6 mm) dental implants used for rehabilitations with single crowns, fixed partial dentures, or both, in the posterior region. MATERIAL AND METHODS: A search in 6 databases was conducted to select randomized controlled trials (RCTs) and nonrandomized controlled trials (N-RCTs). Five meta-analyses were performed, where the risk ratio (RR) was evaluated. The certainty of evidence was evaluated, and the risk of bias was determined from the Joanna Briggs Institute checklist. RESULTS: Fourteen articles were included, 272 wide- and 478 regular-diameter implants. One study presented a low, 3 an unclear, and 11 a high risk of bias. Meta-analyses showed no statistical difference: implant survival, short dental implants in N-RCTs (up to 1 year - RR 1.01 [0.98; 1.03], 1 to 5 years - RR 1.01 [0.94; 1.08], more than 5 years - RR 1.01 [0.97; 1.06]), extrashort dental implants in N-RCTs (RR 1.04 [0.90; 1.20]), RCTs (RR 1.05 [0.88; 1.25]); implant success in N-RCTs (RR 1.01 [0.97; 1.05]); prosthesis success in N-RCTs (RR 1.01 [0.97; 1.05]). CONCLUSIONS: Short and extrashort dental implants with a wide and regular diameter appear to be clinically appropriate options for implant-supported posterior restorations, with high survival, success, and prosthesis success rates.

4.
Braz. j. oral sci ; 22: e238152, Jan.-Dec. 2023. ilus
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-1437694

RESUMEN

Aim: This study evaluated the influence of a wide diameter on extra-short dental implant stress distribution as a retainer for single implant-supported crowns in the atrophic mandible posterior region under axial and oblique load. Methods: Four 3D digital casts of an atrophic mandible, with a single implant-retained crown with a 3:1 crown-to-implant ratio, were created for finite element analysis. The implant diameter used was either 4 mm (regular) or 6 mm (wide), both with 5 mm length. A 200 N axial or 30º oblique load was applied to the mandibular right first molar occlusal surface. The equivalent von Mises stress was recorded for the abutment and implant, minimum principal stress, and maximum shear stress for cortical and cancellous bone. Results: Oblique load increased the stress in all components when compared to axial load. Wide diameter implants showed a decrease of von Mises stress around 40% in both load directions at the implant, and an increase of at least 3.6% at the abutment. Wide diameter implants exhibited better results for cancellous bone in both angulations. However, in the cortical bone, the minimum principal stress was at least 66% greater for wide than regular diameter implants, and the maximum shear stress was more than 100% greater. Conclusion: Extra-short dental implants with wide diameter result in better biomechanical behavior for the implant, but the implications of a potential risk of overloading the cortical bone and bone loss over time, mainly under oblique load, should be investigated


Asunto(s)
Implantes Dentales , Arcada Parcialmente Edéntula , Prótesis Dental de Soporte Implantado , Análisis de Elementos Finitos
5.
J Prosthet Dent ; 2022 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-35931572

RESUMEN

STATEMENT OF PROBLEM: Evidence regarding the retention system for a mandibular overdenture is important for treatment planning. However, the clinical performance of stud and ball attachments for mandibular overdenture retainers is unclear. PURPOSE: The purpose of this systematic review and meta-analysis was to compare the clinical performance and self-reported patient outcomes of ball and stud attachments as mandibular overdenture retainers. MATERIAL AND METHODS: Randomized (RCTs) and nonrandomized (N-RCTs) controlled clinical trials were selected based on the eligibility criteria. The risk of bias was assessed by using the Cochrane Collaboration Tools, and the certainty of the evidence (COE) by using the grades of recommendation, assessment, development, and evaluation (GRADE) workshop approach. Meta-analyses according to the follow-up period were performed for implant survival, prosthetic maintenance and complications, bleeding on probing (BoP), marginal bone loss (MBL), satisfaction, and oral health-related quality of life (OHRQoL). RESULTS: Thirteen RCTs and 4 N-RCTs were included. Twelve studies presented a high risk of bias. The stud demonstrated a lower risk ratio (RR) (P<.001) for maintenance and complications concerning the need for matrix activation (RR 7.12 [2.65, 19.15]) (very low COE) and new overdentures (RR 2.47 [1.02, 5.96]) (moderate COE), ranging from 1 to 5 years of follow-up. Mean difference (MD) for MBL after 1 (MD 0.40 [0.28, 0.52]; P<.001) and 5 years (MD 0.18 [0.16, 0.20]; P<.001) was higher for ball attachments than that for stud (very low COE) attachments. Stud attachments also improved satisfaction (P<.001) when compared with ball attachments (very low COE). Implant survival rate (high COE), BoP (very low COE), and OHRQoL (low COE) were similar for the attachments. CONCLUSIONS: Stud and ball attachments are clinically appropriate options as mandibular overdenture retainers and are capable of restoring OHRQoL. Nevertheless, the stud showed greater improvement in satisfaction and less prosthetic aftercare and MBL.

6.
J Prosthet Dent ; 2022 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-35864024

RESUMEN

STATEMENT OF PROBLEM: Implant-supported single crowns are more prone to screw loosening than splinted prostheses. Therefore, the locking taper system, which has a screwless abutment, may perform better when associated with this type of rehabilitation. However, systematic reviews on this system are lacking. PURPOSE: The purpose of this systematic review was to evaluate the clinical performance and complications of single crowns retained by the locking taper system. MATERIAL AND METHODS: This systematic review was registered at the International Prospective Register of Systematic Reviews (PROSPERO) under CRD42020189921. An electronic search was made in 5 databases and 3 other sources up to February 2021 to select prospective clinical studies evaluating the performance of single crowns retained by the locking taper system by using the outcomes implant survival, success rate, complications, marginal bone loss (MBL), and prosthesis success rate. Four meta-analyses grouped according to the follow-up intervals were performed. The risk of bias of the selected studies was evaluated by using the RoB 2 checklist for randomized controlled trials (RCTs) and Downs and Black for uncontrolled studies. RESULTS: Twelve studies were included: 9 prospective cohort studies and 3 RCTs. A survival rate of 99% (98% to 99%) and a success rate of 97% (92% to 99%) after 5 years were found. Of the total, 2.6% biological and 2.9% prosthetic complications were described. The prosthesis success rate was 97% (96% to 98%) after 5 years. An average of -0.73 mm (-0.93 to -0.52) was found for the MBL after 5 years. The risk-of-bias assessment showed 2 RCTs with high risk and 1 RCT with low risk of bias. Among uncontrolled studies, 2 were classified as poor and 7 as fair. CONCLUSIONS: Single crowns retained by locking taper implants can be safely indicated based on the high survival and success rates achieved in the long term, the maintenance of bone level stability over time, and the low incidence of complications.

SELECCIÓN DE REFERENCIAS