Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Diabetes Obes Metab ; 26(6): 2431-2438, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38514384

RESUMEN

AIMS: To investigate whether the positive effects on glycaemic outcomes of 3-month automated insulin delivery (AID) achieved in 2- to 6-year-old children endure over an extended duration and how AID treatment affects time in tight range (TITR), defined as 3.9-7.8 mmol/L. RESEARCH DESIGN AND METHODS: We analysed 18 months of follow-up data from a non-randomized, prospective, single-arm clinical trial (n = 35) conducted between 2021 and 2023. The main outcome measures were changes in time in range (TIR), glycated haemoglobin (HbA1c), time above range (TAR), TITR, and mean sensor glucose (SG) value during follow-up visits (at 0, 6, 12 and 18 months). The MiniMed 780G AID system in SmartGuard Mode was used for 18 months. Parental diabetes distress was evaluated at 3 and 18 months with the validated Problem Areas in Diabetes-Parent, revised (PAID-PR) survey. RESULTS: Between 0 and 6 months, TIR and TITR increased, and HbA1c, mean SG value and TAR decreased significantly (p < 0.001); the favourable effect persisted through 18 months of follow-up. Between 3 and 18 months, PAID-PR score declined significantly (0 months: mean score 37.5; 3 months: mean score 28.6 [p = 0.06]; 18 months: mean score 24.6 [p < 0.001]). CONCLUSIONS: Treatment with AID significantly increased TITR and TIR in young children. The positive effect of AID on glycaemic control observed after 6 months persisted throughout the 18 months of follow-up. Similarly, parental diabetes distress remained reduced during 18 months follow-up. These findings are reassuring and suggest that AID treatment improves glycaemic control and reduces parental diabetes distress in young children over an extended 18-month follow-up.


Asunto(s)
Glucemia , Diabetes Mellitus Tipo 1 , Hemoglobina Glucada , Hipoglucemiantes , Sistemas de Infusión de Insulina , Insulina , Humanos , Femenino , Masculino , Preescolar , Insulina/administración & dosificación , Insulina/uso terapéutico , Niño , Hemoglobina Glucada/análisis , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/uso terapéutico , Glucemia/análisis , Glucemia/efectos de los fármacos , Glucemia/metabolismo , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/sangre , Estudios Prospectivos , Estudios de Seguimiento , Control Glucémico/métodos , Factores de Tiempo , Automonitorización de la Glucosa Sanguínea
2.
Diabetes Technol Ther ; 25(2): 100-107, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36511831

RESUMEN

Objective: The safety and impact of the advanced hybrid closed-loop (AHCL) system on glycemic outcome in 2- to 6-year-old children with type 1 diabetes and the diabetes distress of caregivers were evaluated. Research Design and Methods: This was an open-label prospective study (n = 35) with historical controls matched by treatment unit, diabetes duration, age, gender, and baseline treatment modality. The inclusion criteria were (1) type 1 diabetes diagnosis >6 months, (2) total daily dose of insulin ≥8 U/day, (3) HbA1c <10% (85 mmol/mol), and (4) capability to use insulin pump and continuous glucose monitoring. The MiniMed 780G™ AHCL in SmartGuard™ Mode was used for 12 weeks. Parental diabetes distress was evaluated with a validated Problem Areas In Diabetes-Parent, revised (PAID-PR) survey. Results: No events of diabetic ketoacidosis or severe hypoglycemia occurred. Between 0 and 12 weeks, HbA1c (mean change = -2.7 mmol/mol [standard deviation 5.7], P = 0.010), mean sensor glucose value (SG) (-0.8 mmol/L [1.0], P < 0.001), and time above range (TAR) (-8.6% [9.5], P < 0.001) decreased and time in range (TIR) (8.3% [9.3], P < 0.001) increased significantly, whereas no significant change in time below range (TBR) was observed. At the same time, PAID-PR score decreased from 37.5 (18.2) to 27.5 (14.8) (P = 0.006). Conclusions: MiniMed 780G™ AHCL is a safe system and 12-week use was associated with improvements in glycemic control in 2- to 6-year-old children with type 1 diabetes. In addition, AHCL is associated with a reduction in parental diabetes distress after 12-week use. ClinicalTrials.gov registration number: NCT04949022.


Asunto(s)
Diabetes Mellitus Tipo 1 , Niño , Humanos , Glucemia , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/complicaciones , Hemoglobina Glucada , Hipoglucemiantes/uso terapéutico , Insulina/efectos adversos , Sistemas de Infusión de Insulina , Estudios Prospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...