Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-24995164

RESUMEN

Shiga toxin-producing Escherichia coli (STEC) and Salmonella are food-borne pathogens commonly associated with beef, and reliable methods are needed to determine their prevalence in beef and to ensure food safety. Retail ground beef was tested for the presence of E. coli O157:H7, STEC serogroups O26, O45, O103, O111, O121, and O145, and Salmonella using the DuPont™ BAX® system method. Ground beef (325 g) samples were enriched in 1.5 L of TSB with 2 mg/L novobiocin at 42°C for 18 h, and then evaluated using the BAX® System real-time PCR assays for E. coli O157:H7 and STEC suite, and the BAX® System standard PCR assays for E. coli O157:H7 MP and Salmonella. Samples positive for STEC target genes by the BAX® System assays were subjected to immunomagnetic separation (IMS) and plating onto modified Rainbow Agar O157. Enrichments that were PCR positive for Salmonella were inoculated into RV broth, incubated for 18 h at 42°C, and then plated onto XLT-4 agar. Presumptive positive STEC and Salmonella colonies were confirmed using the BAX® System assays. Results of the BAX® System STEC assays showed 20/308 (6.5%) of samples positive for both the Shiga toxin (stx) and intimin (eae) genes; 4 (1.3%) for stx, eae, and O26; 1 (0.3%) for stx, eae, and O45; 3 (1%) for stx, eae, and O103; and 1 (0.3%) for stx, eae, and O145. There were also 3 samples positive for stx, eae, and more than one STEC serogroup. Three (1.0%) of the samples were positive using the BAX® System real-time E. coli O157:H7 assay, and 28 (9.1%) were positive using the BAX® System Salmonella assay. STEC O103 and E. coli O157:H7 were isolated from 2/6 and 2/3 PCR positive samples, respectively. Salmonella isolates were recovered and confirmed from 27 of the 28 Salmonella PCR positive samples, and a portion of the isolates were serotyped and antibiotic resistance profiles determined. Results demonstrate that the BAX® System assays are effective for detecting STEC and Salmonella in beef.


Asunto(s)
Técnicas Bacteriológicas/métodos , Carne/microbiología , Técnicas de Diagnóstico Molecular/métodos , Salmonella/aislamiento & purificación , Toxina Shiga/genética , Escherichia coli Shiga-Toxigénica/aislamiento & purificación , Adhesinas Bacterianas/genética , Animales , Bovinos , Proteínas de Escherichia coli/genética , Humanos , Pruebas de Sensibilidad Microbiana , Prevalencia , Salmonella/clasificación , Salmonella/genética , Serotipificación , Escherichia coli Shiga-Toxigénica/clasificación , Escherichia coli Shiga-Toxigénica/genética
2.
J AOAC Int ; 97(3): 868-75, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25051636

RESUMEN

A multilaboratory study was conducted to evaluate the ability of the DuPont BAX System Real-Time PCR Assay for Salmonella to detect the target species in a variety of foods and environmental surfaces. Internal validation studies were performed by DuPont Nutrition & Health on 24 different sample types to demonstrate the reliability of the test method among a wide variety of sample types. Two of these matrixes-pork and turkey frankfurters and pasteurized, not-from-concentrate orange juice without pulp-were each evaluated in 14 independent laboratories as part of the collaborative study to demonstrate repeatability and reproducibility of the internal laboratory results independent of the end user. Frankfurter samples were evaluated against the U.S. Department of Agriculture, Food Safety and Inspection Service reference method as a paired study, while orange juice samples were evaluated against the U.S. Food and Drug Administration reference method as an unpaired study, using a proprietary media for the test method. Samples tested in this study were artificially inoculated with a Salmonella strain at levels expected to produce low (0.2-2.0 CFU/test portion) or high (5 CFU/test portion) spike levels on the day of analysis. For each matrix, the collaborative study failed to show a statistically significant difference between the candidate method and the reference method using the probability of detection statistical model.


Asunto(s)
Técnicas Bacteriológicas/métodos , Microbiología de Alimentos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Salmonella/aislamiento & purificación , Reproducibilidad de los Resultados , Salmonella/genética
3.
J Food Prot ; 77(2): 180-8, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24490911

RESUMEN

The "top-six" non-O157 Shiga toxin-producing Escherichia coli (STEC) serogroups (O26, O45, O103, O111, O121, and O145) most frequently associated with outbreaks and cases of foodborne illnesses have been declared as adulterants in beef by the U.S. Department of Agriculture Food Safety and Inspection Service (FSIS). Regulatory testing in beef began in June 2012. The purpose of this study was to evaluate the DuPont BAX System method for detecting these top six STEC strains and strains of E. coli O157:H7. For STEC, the BAX System real-time STEC suite was evaluated, including a screening assay for the stx and eae virulence genes and two panel assays to identify the target serogroups: panel 1 detects O26, O111, and O121, and panel 2 detects O45, O103, O145. For E. coli O157:H7, the BAX System real-time PCR assay for this specific serotype was used. Sensitivity of each assay for the PCR targets was ≥1.23 × 10(3) CFU/ml in pure culture. Each assay was 100% inclusive for the strains tested (20 to 50 per assay), and no cross-reactivity with closely related strains was observed in any of the assays. The performance of the BAX System methods was compared with that of the FSIS Microbiology Laboratory Guidebook (MLG) methods for detection of the top six STEC and E. coli O157:H7 strains in ground beef and beef trim. Generally, results of the BAX System method were similar to those of the MLG methods for detecting non-O157 STEC and E. coli O157:H7. Reducing or eliminating novobiocin in modified tryptic soy broth (mTSB) may improve the detection of STEC O111 strains; one beef trim sample inoculated with STEC O111 produced a negative result when enriched in mTSB with 8 mg/liter novobiocin but was positive when enriched in mTSB without novobiocin. The results of this study indicate the feasibility of deploying a panel of real-time PCR assay configurations for the detection and monitoring of the top six STEC and E. coli O157:H7 strains in beef. The approach could easily be adapted for additional multiplex assays should regulations expand to include other O serogroups or virulence genes.


Asunto(s)
Contaminación de Alimentos/análisis , Carne/microbiología , Reacción en Cadena de la Polimerasa Multiplex/métodos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Escherichia coli Shiga-Toxigénica/aislamiento & purificación , Animales , Técnicas Bacteriológicas/métodos , Bovinos , Proteínas de Escherichia coli/genética , Inspección de Alimentos/métodos , Inspección de Alimentos/normas , Microbiología de Alimentos , Humanos , Sensibilidad y Especificidad , Estados Unidos
4.
J AOAC Int ; 94(3): 863-71, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21797015

RESUMEN

The new BAX System PCR Assay for Genus Listeria 24E was evaluated for detecting Listeria spp. in frankfurters, spinach, cooked shrimp, queso fresco cheese, and on stainless steel surfaces with a single-stage enrichment in BAX System 24 Listeria Enrichment Broth (24 LEB). Method comparison studies performed on samples with low-level inoculates showed that the BAX System demonstrates a sensitivity equivalent or superior to the U.S. Food and Drug Administration's Bacteriological Analytical Manual and the U.S. Department of Agriculture-Food Safety and Inspection Service culture methods, but with a significantly shorter time to result. Tests to evaluate inclusivity and exclusivity returned no false-negative and no false-positive results on a diverse panel of isolates, and tests for lot-to-lot variability and tablet stability demonstrated consistent performance. Ruggedness studies determined that none of the factors examined, within the range of deviations from specified parameters examined, affect the performance of the assay.


Asunto(s)
Técnicas Bacteriológicas/métodos , Microbiología de Alimentos , Listeria/aislamiento & purificación , Microbiología Ambiental , Contaminación de Equipos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...