Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38971554

RESUMEN

OBJECTIVE: To identify the presence and distribution of histopathological features of synovial inflammation and tissue damage, and to test their associations with ultrasound (US) imaging measures of synovitis and patient-reported measures of pain in knee osteoarthritis (OA). DESIGN: In the cross-sectional study of 122 patients undergoing surgery for painful late-stage (Kellgren-Lawrence Grade 3 or 4) knee OA, we compared US measures of synovitis (n = 118) and pain (Knee Injury and Osteoarthritis Outcome Score) to histopathological measures of inflammation vs. synovial tissue damage in synovial tissue biopsies. Associations of histopathological features with US measures of inflammation or pain were assessed using linear or logistic regression while controlling for covariates. RESULTS: Histopathological features of inflammation were associated with higher odds of moderate/severe US synovitis (odds ratio [OR] = 1.34 [95%CI 1.04, 1.74), whereas features of synovial tissue damage were associated with lower odds of moderate/severe US synovitis (OR = 0.77 [95%CI 0.57, 1.03]). Worse histopathological scores for synovial tissue damage were associated with more pain (-1.47 [95%CI -2.88, -0.05]), even while adjusting for synovial inflammation (-1.61 [95%CI -3.12, -0.10]). CONCLUSIONS: Synovial tissue damage is associated with pain in late-stage knee OA, independent from inflammation and radiographic damage. These novel findings suggest that preventing synovial tissue damage may be an important goal of disease-modifying OA therapy.

2.
J Arthroplasty ; 39(9S1): S67-S72, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38830433

RESUMEN

BACKGROUND: The aim of the study was to analyze the Canadian Cardiovascular Society (CCS) guidelines for routine postoperative troponin testing after elective total hip arthroplasty (THA) to reduce the mortality rate resulting from myocardial injury. The purpose of this study was to assess the prognostic relevance of implementing these guidelines to minimize cardiac events in patients undergoing elective THA. METHODS: Patients who underwent THA surgery in 2020 were included in the study. The inclusion criteria were elective THA patients aged ≥45 years, while emergency, revision, and simultaneous bilateral THA surgeries were excluded. The patients were categorized into 4 groups based on the CCS guidelines. RESULTS: The study included 669 patients who had an average age of 67 years. There were 43 patients (6.4%), who experienced a rise in troponin levels ≥30 ng/L and developed myocardial injury after noncardiac surgery. Among these patients, 8 developed cardiac complications, and one experienced a serious cardiac event that resulted in death. Notably, there was a significant increase in the length of hospital stay for patients who received the postoperative screening protocol. CONCLUSIONS: The implementation of the CCS guidelines for routine postoperative troponin testing in elective THA surgery did not significantly decrease the rate of cardiac events or mortality.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Complicaciones Posoperatorias , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Anciano , Masculino , Femenino , Persona de Mediana Edad , Canadá/epidemiología , Complicaciones Posoperatorias/prevención & control , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/epidemiología , Troponina/sangre , Guías de Práctica Clínica como Asunto , Procedimientos Quirúrgicos Electivos/efectos adversos , Estudios Retrospectivos
3.
J Arthroplasty ; 39(9S1): S51-S54, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38830428

RESUMEN

BACKGROUND: The incidence of total joint arthroplasty is increasing, with added emphasis on shifting care toward outpatient surgery. This has demonstrated improvements in costs and care; however, safety must be prioritized. Published assessment tools highlight candidates for outpatient surgery; however, they often do not define patients who have a worse prognosis. Limited healthcare resources occasionally force patients to convert to outpatient surgery or risk cancellation, creating a dilemma for both patients and surgeons. We evaluated the short-term (90-day) outcomes of patients converted from planned inpatient admission to same-day discharge on day of surgery outpatients and sought to identify any groups at risk, who may not be appropriate for this conversion. METHODS: We identified all patients undergoing planned inpatient total hip or knee arthroplasty at a tertiary academic medical center over a 2-year period. We included patients discharged the day of surgery for analysis, excluding revision procedures and those performed for fracture care. A manual chart review identified demographic factors and primary outcome measures; including reoperation, readmission, and emergency room visits within a 90-day postoperative period. RESULTS: We identified a total of 80 patients who converted from inpatient to outpatient surgery over a 2-year interval. Over the first 90 days postoperatively 4 (5%) patients were readmitted: 2 (2.5%) for medical complications and 2 (2.5%) for reoperation. There were 2 (2.5%) reoperations; one (1.25%) for manipulation under anesthesia, and one (1.25%) for periprosthetic joint infection. There were 5 (6.3%) wound complications; however, only one (1.25%) required surgical intervention. A total of 5 (6.3%) patients returned to an emergency department, leading to a single (1.25%) hospital readmission. CONCLUSIONS: Hospital and healthcare resources are occasionally limited to the extent that patients must convert to outpatient surgery or risk cancellation. At our institution, the same-day conversion of planned inpatient hip and knee arthroplasty patients to outpatient surgery was safe and did not increase short-term clinical outcomes or complications.


Asunto(s)
Procedimientos Quirúrgicos Ambulatorios , Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Readmisión del Paciente , Humanos , Masculino , Femenino , Anciano , Persona de Mediana Edad , Readmisión del Paciente/estadística & datos numéricos , Resultado del Tratamiento , Reoperación/estadística & datos numéricos , Estudios Retrospectivos , Pacientes Internos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Anciano de 80 o más Años
4.
J Arthroplasty ; 39(9S1): S243-S247, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38848790

RESUMEN

BACKGROUND: Periprosthetic joint infection (PJI) continues to be one of the leading causes of failure following total hip arthroplasty (THA). The objectives of the study were to (1) determine the minimum 2-year infection-free survivorship of 2-stage revision THA, (2) determine the causative organisms for repeat 2-stage revision THA, and (3) characterize the results of failed 2-stage revisions and evaluate patient-reported outcome measures (PROMs). METHODS: A retrospective chart review was completed for patients who underwent 2-stage revision THA for PJI. Prospective data were collected on each patient, including demographics, causative organisms, complications, and type of reoperation. The PROMs, including Harris Hip Score, 12-item Short-Form Health Survey, and Western Ontario and McMaster Universities Osteoarthritis Index scores were obtained prior to 2-stage revision THA surgery and annually as part of standard clinical and radiographic follow-up. RESULTS: A total of 328 patients who underwent a 2-stage revision THA for a PJI were included in the study (mean age 67 years [range, 28 to 90], mean body mass index of 30.6 [range, 15 to 57]). The overall infection-free survivorship for 2-stage revision THA was 73.8% at a minimum of 2 years (range, 2 to 20). Overall, 194 (59.1%) patients who had successful infection eradication underwent a 2-revision THA only. The most common single organisms infected were Staphylococcus aureus (12.5%) and Staphylococcus epidermidis (11%). Higher reoperation rates were found in cases with methicillin-resistant Staphylococcus aureus and polymicrobial infections. All PROMs showed statistical improvement from preoperatively to the latest follow-up appointment. CONCLUSIONS: Two-stage revision THA is associated with a good success rate in the treatment of PJIs at mid-term to long-term follow-up. Polymicrobial and methicillin-resistant Staphylococcus aureus infections are poor prognostic factors, making the eradication of infection more difficult. The management of PJIs continues to be one of the most important orthopaedic challenges to treat.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Infecciones Relacionadas con Prótesis , Reoperación , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Reoperación/estadística & datos numéricos , Anciano , Persona de Mediana Edad , Masculino , Femenino , Infecciones Relacionadas con Prótesis/cirugía , Infecciones Relacionadas con Prótesis/etiología , Estudios Retrospectivos , Adulto , Estudios de Seguimiento , Anciano de 80 o más Años , Prótesis de Cadera/efectos adversos , Resultado del Tratamiento , Medición de Resultados Informados por el Paciente , Staphylococcus aureus Resistente a Meticilina/aislamiento & purificación , Infecciones Estafilocócicas/etiología , Infecciones Estafilocócicas/cirugía
5.
J Arthroplasty ; 39(8S1): S95-S99, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38626864

RESUMEN

BACKGROUND: Despite the growing popularity of cementless total knee arthroplasty (TKA) in younger patients, the outcomes are unclear in the elderly population. We aimed to compare the clinical outcomes and survivorship of cementless TKA between different age groups. METHODS: Utilizing our prospectively collected institutional database, we retrospectively reviewed all patients undergoing primary cementless TKAs at a tertiary care institute. We identified 347 TKA, which were divided into 3 groups based on age at the time of surgery. Group A was ≤ 60 years, Group B was 60 to ≤ 70 years, and Group C was > 70 years. We compared clinical outcomes (Knee Society Clinical Rating System [KSCRS], Western Ontario and McMaster University Osteoarthritis Index [WOMAC], and Veterans Rand 12 Item Health Survey [VR-12]) and survivorship between the groups. RESULTS: At final follow-up, range of motion, KSCRS, WOMAC, and VR-12 physical score were comparable (P > .05). The VR-12 Mental score was higher in Group B and Group C than in Group A (P = .003). Compared to preoperative scores, the change in KSCRS, WOMAC, and VR-12 physical and mental scores was comparable at the final follow-up (P > .05). No patient underwent revision for aseptic loosening. CONCLUSIONS: There were no cases of revision surgery for aseptic loosening in our cohort of 347 cementless TKAs. Patients > 70 years of age undergoing cementless TKA can achieve clinical scores equivalent to those of younger patients at short term (2-year) follow-up. Longer-term survivorship is still required, but based on early data, cementless TKA can be a safe option for older patients.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Artroplastia de Reemplazo de Rodilla/instrumentación , Anciano , Masculino , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Factores de Edad , Falla de Prótesis , Osteoartritis de la Rodilla/cirugía , Rango del Movimiento Articular , Anciano de 80 o más Años , Articulación de la Rodilla/cirugía , Estudios de Seguimiento , Reoperación/estadística & datos numéricos
6.
Can J Surg ; 67(2): E85-E90, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38453351

RESUMEN

BACKGROUND: Interest in cementless total knee arthroplasty (TKA) has increased with advancement of biomaterials and implant design and associated improved longevity. We sought to evaluate the gap patterns and radiolucent zones radiographically for 2 newer-generation cementless TKA designs. METHODS: We retrospectively reviewed our single-institution database between January 2017 and December 2019. We identified patients with a porous keeled tibia base-plate with 4-bullet cruciform spikes and peri-apatite coated femoral component (study group 1) and patients who received a cementless porous coated femoral component and rotating platform tibia baseplate with 4 peripheral porous coated pegs around a central cone (study group 2). We identified gap patterns at 6 weeks and at 1 year or more postoperatively on radiographs, noting indications for reoperation. RESULTS: We identified 228 patients in study group 1 and 41 patients in study group 2. At 1-year follow-up, we found evidence of resolved femoral gaps in 52 (72.2%) of 72 patients in study group 1 and 10 (58.8%) of 17 patients in study group 2 (p = 0.124). We identified 27 (84.3%) of 32 patients in study group 1 and 7 (70.0%) of 10 patients in study group 2 with resolved tibia gaps (p = 0.313). After 1 year, there were significantly more Zone 3a femoral zonal radiolucent gaps (p = 0.001) and Zone 8 tibia zonal radiolucent gaps (p = 0.002) in study group 2 than in study group 1. There were 4 reoperations for study group 1 and 0 reoperations for study group 2. CONCLUSION: The modern cementless TKA systems have varied gap patterns in postoperative radiographs, which may be attributed to the implant design. Most radiolucent gaps resolve radiographically on follow-up.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Estudios de Seguimiento , Estudios Retrospectivos , Fémur/diagnóstico por imagen , Fémur/cirugía , Reoperación , Diseño de Prótesis , Resultado del Tratamiento , Falla de Prótesis
7.
J Arthroplasty ; 39(8): 2111-2115, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38522799

RESUMEN

BACKGROUND: Bicruciate-stabilized (BCS) total knee arthroplasty (TKA) designs attempt to approximate natural knee mechanics. Multiple surgical techniques, including gap balancing (GB) and measured resection (MR), have been developed to provide optimal implant positioning and soft-tissue balance. The goal of this study was to determine the effect of surgical technique on BCS TKA contact kinematics. Secondary goals included investigating the change of kinematics over time and comparing BCS TKA kinematics to a posterior-stabilized (PS) design. METHODS: The study included the BCS-GB, BCS-MR, and PS-MR groups. The BCS-GB and BCS-MR groups underwent weight-bearing radiostereometric analysis for multiple knee flexion angles at 3 months and 1 year postoperatively, whereas the PS-MR group was imaged at 1 year postoperatively. The medial and lateral contact kinematics were determined from implant poses. RESULTS: There were no differences in BCS TKA kinematics between the GB and MR techniques. There were differences in the mid-flexion ranges when comparing the 3-month and 1-year kinematics of the BCS design; however, they were less than 1.5 mm. Differences existed between the kinematics of the BCS and PS designs at all flexion angles for the medial condyle (P < .0006) and at 0° of flexion on the lateral condyle (P < .0001). CONCLUSIONS: Contact kinematics for a BCS design were similar for both surgical techniques, suggesting both are appropriate for this design. Small, likely clinically insignificant differences were found between 3-month and 1-year kinematics. The BCS TKA kinematics differed from the PS design; however, it is unclear whether these differences improve clinical outcomes.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Articulación de la Rodilla , Prótesis de la Rodilla , Diseño de Prótesis , Rango del Movimiento Articular , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Artroplastia de Reemplazo de Rodilla/instrumentación , Fenómenos Biomecánicos , Femenino , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/fisiopatología , Articulación de la Rodilla/fisiología , Masculino , Anciano , Persona de Mediana Edad , Soporte de Peso , Análisis Radioestereométrico , Osteoartritis de la Rodilla/cirugía
8.
J Arthroplasty ; 39(9S1): S208-S212, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38521249

RESUMEN

BACKGROUND: Modular titanium fluted tapered (TFT) stems have demonstrated excellent clinical success for femoral revision total hip arthroplasty (THA) surgery. This study reports the short-term outcomes of a novel modern monoblock TFT stem used for revision and complex primary THA with a minimum of 2 years of follow-up. METHODS: We identified 126 patients who received a single monoblock TFT stem: 26 patients for complex THA (failed fracture fixation) and 100 patients for revision THA. The reasons for revision THA included 40 for previous periprosthetic joint infection, 42 for aseptic loosening, 9 for trunnionosis, and 9 for periprosthetic fractures. The Paprosky grading for femoral bone loss at the time of surgery and the measured subsidence of femoral stems at 3-month follow-up were determined. We evaluated the number and indications for reoperations. RESULTS: The mean time from surgery was 3.9 years (range, 2.0 to 6.9). A paired t-test analysis showed significant improvement from preoperative versus postoperative clinical outcome scores (P < .001) for Harris Hip Score (38.76 ± 15.24 versus 83.42 ± 15.38), Western Ontario and McMaster Universities Arthritis Index (45.6 ± 19.0 versus 69.9 ± 21.3), Veterans RAND 12 Item Health Survey Physical component (31.7 ± 8.1 versus 37.8 ± 11.3), and Veterans RAND 12 Item Health Survey Mental component (48.2 ± 12.2 versus 51.6 ± 12.5). The Paprosky grading for femoral bone loss was Grade 1 (3.9%), Grade 2 (35.7%), Grade 3A (47.6%), Grade 3B (11.1%), and Grade 4 (1.6%) cases. There were 18 reoperations (14.7%), with 13 for periprosthetic joint infection (7 treated with implant retention and 6 treated with a 2-stage revision), 4 for instability, and 1 for acetabular aseptic loosening. There were no aseptic failures of the stem. CONCLUSIONS: This novel modern monoblock TFT stem provided reliable femoral fixation and has increasingly supplanted the use of modular TFT stems for complex primary and revision surgery in our institution.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Diseño de Prótesis , Reoperación , Titanio , Humanos , Artroplastia de Reemplazo de Cadera/instrumentación , Reoperación/estadística & datos numéricos , Masculino , Femenino , Prótesis de Cadera/efectos adversos , Persona de Mediana Edad , Anciano , Resultado del Tratamiento , Estudios de Seguimiento , Adulto , Anciano de 80 o más Años , Falla de Prótesis , Estudios Retrospectivos , Fémur/cirugía
9.
Bone Jt Open ; 5(1): 20-27, 2024 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-38229582

RESUMEN

Aims: A novel enhanced cement fixation (EF) tibial implant with deeper cement pockets and a more roughened bonding surface was released to market for an existing total knee arthroplasty (TKA) system.This randomized controlled trial assessed fixation of the both the EF (ATTUNE S+) and standard (Std; ATTUNE S) using radiostereometric analysis. Methods: Overall, 50 subjects were randomized (21 EF-TKA and 23 Std-TKA in the final analysis), and had follow-up visits at six weeks, and six, 12, and 24 months to assess migration of the tibial component. Low viscosity bone cement with tobramycin was used in a standardized fashion for all subjects. Patient-reported outcome measure data was captured at preoperative and all postoperative visits. Results: The patient cohort mean age was 66 years (SD seven years), 59% were female, and the mean BMI was 32 kg/m2 (SD 6 kg/m2). Mean two-year subsidence of the EF-TKA was 0.056 mm (95% confidence interval (CI) 0.025 to 0.086) versus 0.006 mm (95% CI -0.029 to 0.040) for the Std-TKA, and the two-year maximum total point motion (MTPM) was 0.285 mm (95% upper confidence limit (UCL) ≤ 0.363) versus 0.346 mm (95% UCL ≤ 0.432), respectively, for a mean difference of -0.061 mm (95% CI -0.196 to 0.074). Inducible displacement also did not differ between groups. The MTPMs between 12 and 24 months for each group was below the published threshold of 0.2 mm for predicting early aseptic loosening (p < 0.001 and p = 0.001, respectively). Conclusion: Both the enhanced fixation and the standard tibial implant design showed fixation with a predicted low risk of long-term aseptic loosening.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA