Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Front Oncol ; 13: 1222800, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37795436

RESUMEN

Background: In radiotherapy, especially when treating children, minimising exposure of healthy tissue can prevent the development of adverse outcomes, including second cancers. In this study we propose a validated Monte Carlo framework to evaluate the complete patient exposure during paediatric brain cancer treatment. Materials and methods: Organ doses were calculated for treatment of a diffuse midline glioma (50.4 Gy with 1.8 Gy per fraction) on a 5-year-old anthropomorphic phantom with 3D-conformal radiotherapy, intensity modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT) and intensity modulated pencil beam scanning (PBS) proton therapy. Doses from computed tomography (CT) for planning and on-board imaging for positioning (kV-cone beam CT and X-ray imaging) accounted for the estimate of the exposure of the patient including imaging therapeutic dose. For dose calculations we used validated Monte Carlo-based tools (PRIMO, TOPAS, PENELOPE), while lifetime attributable risk (LAR) was estimated from dose-response relationships for cancer induction, proposed by Schneider et al. Results: Out-of-field organ dose equivalent data of proton therapy are lower, with doses between 0.6 mSv (testes) and 120 mSv (thyroid), when compared to photon therapy revealing the highest out-of-field doses for IMRT ranging between 43 mSv (testes) and 575 mSv (thyroid). Dose delivered by CT ranged between 0.01 mSv (testes) and 72 mSv (scapula) while a single imaging positioning ranged between 2 µSv (testes) and 1.3 mSv (thyroid) for CBCT and 0.03 µSv (testes) and 48 µSv (scapula) for X-ray. Adding imaging dose from CT and daily CBCT to the therapeutic demonstrated an important contribution of imaging to the overall radiation burden in the course of treatment, which is subsequently used to predict the LAR, for selected organs. Conclusion: The complete patient exposure during paediatric brain cancer treatment was estimated by combining the results from different Monte Carlo-based dosimetry tools, showing that proton therapy allows significant reduction of the out-of-field doses and secondary cancer risk in selected organs.

2.
Front Oncol ; 12: 882506, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35875147

RESUMEN

Background: The out-of-the-field absorbed dose affects the probability of primary second radiation-induced cancers. This is particularly relevant in the case of pediatric treatments. There are currently no methods employed in the clinical routine for the computation of dose distributions from stray radiation in radiotherapy. To overcome this limitation in the framework of conventional teletherapy with photon beams, two computational tools have been developed-one based on an analytical approach and another depending on a fast Monte Carlo algorithm. The purpose of this work is to evaluate the accuracy of these approaches by comparison with experimental data obtained from anthropomorphic phantom irradiations. Materials and Methods: An anthropomorphic phantom representing a 5-year-old child (ATOM, CIRS) was irradiated considering a brain tumor using a Varian TrueBeam linac. Two treatments for the same planned target volume (PTV) were considered, namely, intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). In all cases, the irradiation was conducted with a 6-MV energy beam using the flattening filter for a prescribed dose of 3.6 Gy to the PTV. The phantom had natLiF : Mg, Cu, P (MCP-N) thermoluminescent dosimeters (TLDs) in its 180 holes. The uncertainty of the experimental data was around 20%, which was mostly attributed to the MCP-N energy dependence. To calculate the out-of-field dose, an analytical algorithm was implemented to be run from a Varian Eclipse TPS. This algorithm considers that all anatomical structures are filled with water, with the exception of the lungs which are made of air. The fast Monte Carlo code dose planning method was also used for computing the out-of-field dose. It was executed from the dose verification system PRIMO using a phase-space file containing 3x109 histories, reaching an average standard statistical uncertainty of less than 0.2% (coverage factor k = 1 ) on all voxels scoring more than 50% of the maximum dose. The standard statistical uncertainty of out-of-field voxels in the Monte Carlo simulation did not exceed 5%. For the Monte Carlo simulation the actual chemical composition of the materials used in ATOM, as provided by the manufacturer, was employed. Results: In the out-of-the-field region, the absorbed dose was on average four orders of magnitude lower than the dose at the PTV. For the two modalities employed, the discrepancy between the central values of the TLDs located in the out-of-the-field region and the corresponding positions in the analytic model were in general less than 40%. The discrepancy in the lung doses was more pronounced for IMRT. The same comparison between the experimental and the Monte Carlo data yielded differences which are, in general, smaller than 20%. It was observed that the VMAT irradiation produces the smallest out-of-the-field dose when compared to IMRT. Conclusions: The proposed computational methods for the routine calculation of the out-of-the-field dose produce results that are similar, in most cases, with the experimental data. It has been experimentally found that the VMAT irradiation produces the smallest out-of-the-field dose when compared to IMRT for a given PTV.

3.
Front Oncol ; 12: 882489, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35756661

RESUMEN

Proton therapy enables to deliver highly conformed dose distributions owing to the characteristic Bragg peak and the finite range of protons. However, during proton therapy, secondary neutrons are created, which can travel long distances and deposit dose in out-of-field volumes. This out-of-field absorbed dose needs to be considered for radiation-induced secondary cancers, which are particularly relevant in the case of pediatric treatments. Unfortunately, no method exists in clinics for the computation of the out-of-field dose distributions in proton therapy. To help overcome this limitation, a computational tool has been developed based on the Monte Carlo code TOPAS. The purpose of this work is to evaluate the accuracy of this tool in comparison to experimental data obtained from an anthropomorphic phantom irradiation. An anthropomorphic phantom of a 5-year-old child (ATOM, CIRS) was irradiated for a brain tumor treatment in an IBA Proteus Plus facility using a pencil beam dedicated nozzle. The treatment consisted of three pencil beam scanning fields employing a lucite range shifter. Proton energies ranged from 100 to 165 MeV. A median dose of 50.4 Gy(RBE) with 1.8 Gy(RBE) per fraction was prescribed to the initial planning target volume (PTV), which was located in the cerebellum. Thermoluminescent detectors (TLDs), namely, Li-7-enriched LiF : Mg, Ti (MTS-7) type, were used to detect gamma radiation, which is produced by nuclear reactions, and secondary as well as recoil protons created out-of-field by secondary neutrons. Li-6-enriched LiF : Mg,Cu,P (MCP-6) was combined with Li-7-enriched MCP-7 to measure thermal neutrons. TLDs were calibrated in Co-60 and reported on absorbed dose in water per target dose (µGy/Gy) as well as thermal neutron dose equivalent per target dose (µSv/Gy). Additionally, bubble detectors for personal neutron dosimetry (BD-PND) were used for measuring neutrons (>50 keV), which were calibrated in a Cf-252 neutron beam to report on neutron dose equivalent dose data. The Monte Carlo code TOPAS (version 3.6) was run using a phase-space file containing 1010 histories reaching an average standard statistical uncertainty of less than 0.2% (coverage factor k = 1) on all voxels scoring more than 50% of the maximum dose. The primary beam was modeled following a Fermi-Eyges description of the spot envelope fitted to measurements. For the Monte Carlo simulation, the chemical composition of the tissues represented in ATOM was employed. The dose was tallied as dose-to-water, and data were normalized to the target dose (physical dose) to report on absorbed doses per target dose (mSv/Gy) or neutron dose equivalent per target dose (µSv/Gy), while also an estimate of the total organ dose was provided for a target dose of 50.4 Gy(RBE). Out-of-field doses showed absorbed doses that were 5 to 6 orders of magnitude lower than the target dose. The discrepancy between TLD data and the corresponding scored values in the Monte Carlo calculations involving proton and gamma contributions was on average 18%. The comparison between the neutron equivalent doses between the Monte Carlo simulation and the measured neutron doses was on average 8%. Organ dose calculations revealed the highest dose for the thyroid, which was 120 mSv, while other organ doses ranged from 18 mSv in the lungs to 0.6 mSv in the testes. The proposed computational method for routine calculation of the out-of-the-field dose in proton therapy produces results that are compatible with the experimental data and allow to calculate out-of-field organ doses during proton therapy.

4.
Z Med Phys ; 32(2): 159-172, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34301443

RESUMEN

For the epidemiological evaluation of long-term side effects of radiotherapy patients, it is important to know the doses to organs and tissues everywhere in the patient. Computed tomography (CT) images of the patients which contain the anatomical information are sometimes available for each treated patient. However, the available CT scans usually cover only the treated volume of the patient including the target and surrounding anatomy. To overcome this limitation, in this work we describe the development of a software tool using the Varian Eclipse Scripting API for extending a partial-body CT to a whole-body representation in the treatment planning system for dose calculation. The whole-body representation is created by fusing the partial-body CT with a similarly sized whole-body computational phantom selected from a library containing 64 phantoms of different heights, weights, and genders. The out-of-field dose is calculated with analytical models from the literature and merged with the treatment planning system-calculated dose. To test the method, the out-of-field dose distributions on the computational phantoms were compared to dose calculations on whole-body patient CTs. The mean doses, D2% and D98% were compared in 26 organs and tissues for 14 different treatment plans in 5 patients using 3D-CRT, IMRT, VMAT, coplanar and non-coplanar techniques. From these comparisons we found that mean relative differences between organ doses ranged from -10% and +20% with standard deviations of up to 40%. The developed method will help epidemiologists and researchers estimate organ doses outside the treated volume when only limited treatment planning CT information is available.


Asunto(s)
Radioterapia Conformacional , Radioterapia de Intensidad Modulada , Imagen Corporal , Femenino , Humanos , Masculino , Fantasmas de Imagen , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Conformacional/métodos , Radioterapia de Intensidad Modulada/métodos
5.
Med Phys ; 48(5): 2566-2571, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33506490

RESUMEN

PURPOSE: A nanodosimeter is a type of detector which measures single ionizations in a small gaseous volume in order to obtain ionization cluster size probability distributions for characterization of radiation types. Working nanodosimeter detectors are usually bulky machines which require a lot of space. In this work, the authors present a compact ceramic nanodosimeter detector and report on first measurements of cluster size distributions of 5 MeV alpha particles. METHODS: Single ionization measurements are achieved by applying a weak electric field to collect positive ions in a hole in a ceramic plate. Inside the ceramic plate, due to a strong electric field, the ions are accelerated and produce impact-ionizations. The resulting electron avalanche is detected in a read-out electrode. A Bayesian unfolding algorithm is then applied to the experimentally obtained cluster size distributions to reconstruct the true cluster size distributions. RESULTS: Experimentally obtained cluster size distributions by the compact nanodosimeter detector are presented. The reconstructed cluster size distributions agreed well with Monte Carlo simulated cluster size distributions for small volumes (diameter = 2.5 nm). For larger volumes, discrepancies between the reconstructed cluster size distributions and cluster size distributions from Monte Carlo simulations were observed. CONCLUSIONS: For the first time, ionization cluster size probability distributions could be obtained by a small and compact nanodosimeter detector. This signifies the achievement of a critical step toward the wide application of nanodosimetric characterization of radiation types including in clinical environments.


Asunto(s)
Radiometría , Teorema de Bayes , Simulación por Computador , Método de Montecarlo , Fenómenos Físicos
6.
Med Phys ; 47(11): 5872-5881, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32285455

RESUMEN

PURPOSE: In view of the potential of treatment plan optimization based on nanodosimetric quantities, fast Monte Carlo methods for obtaining nanodosimetric quantities in macroscopic volumes are important. In this work, a "fast" method for obtaining nanodosimetric parameters from a clinical proton pencil beam in a macroscopic volume is compared with a slow and detailed method. Furthermore, the variations of these parameters, when obtained with the Monte Carlo codes TOPAS and NOREC, are investigated. METHODS: Monte Carlo track structure simulations of 1 keV-100 MeV protons and 12 eV-1 MeV electrons in a volume of 8 nm 3 liquid water provided us with an atlas of cluster size distributions. Two kinds of ionization cluster size distributions were recorded, counting all ionizations or only ionizations directly produced by the primary particle. The simulations of the proton pencil beam were performed in two different ways. A "fast" method where only the protons were simulated and a "slow and detailed" method where protons and electrons were simulated in order to obtain spectra at different depths. The obtained spectra were then convoluted with cluster size distributions. RESULTS: It was shown that the nanodosimetric quantity F 2 from the "fast" method is, depending on the location, between 43.6% and 63.6% smaller than the F 2 obtained by the "slow and detailed" method. However, it was also shown that variations of nanodosimetric quantities are even larger when the cluster size distributions of the electrons are simulated with the Monte Carlo code NOREC, that is, the cumulative F 2 probabilities obtained with NOREC were between 50.8% and 75.5% smaller than the F 2 probabilities obtained with TOPAS. CONCLUSIONS: As long as the uncertainties of different Monte Carlo codes are not improved, it is feasible to only simulate protons in a macroscopic volume. It must be noted, however, that the uncertainty is in the order of 100%.


Asunto(s)
Terapia de Protones , Estudios de Factibilidad , Método de Montecarlo , Protones , Radiometría
7.
Radiat Environ Biophys ; 59(3): 439-450, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32277259

RESUMEN

A radiation action model based on nanodosimetry is presented. It is motivated by the finding that the biological effects of various types of ionizing radiation lack a consistent relation with absorbed dose. It is postulated that the common fundamental cause of these effects is the production of elementary sublesions (DSB), which are created at a rate that is proportional to the probability to produce more than two ionisations within a volume of 10 base pairs of the DNA. The concepts of nanodosimetry allow for a quantitative characterization of this process in terms of the cumulative probability F2. The induced sublesions can interact in two ways to produce lethal damage. First, if two or more sublesions accumulate in a locally limited spherical volume of 3-10 nm in diameter, clustered DNA damage is produced. Second, consequent interactions or rearrangements of some of the initial damage over larger distances (~ µm) can produce additional lethal damage. From the comparison of theoretical predictions deduced from this concept with experimental data on relative biological effectiveness, a cluster volume with a diameter of 7.5 nm could be determined. It is shown that, for electrons, the predictions agree well with experimental data over a wide energy range. The only free parameter needed to model cell survival is the intersection cross-section which includes all relevant cell-specific factors. Using ultra-soft X-rays it could be shown that the energy dependence of cell survival is directly governed by the nanodosimetric characteristics of the radiation track structure. The cell survival model derived in this work exhibits exponential cell survival at a high dose and a finite gradient of cell survival at vanishing dose, as well as the dependence on dose-rate.


Asunto(s)
Modelos Biológicos , Dosis de Radiación , Rayos X , Supervivencia Celular
8.
Radiat Prot Dosimetry ; 183(1-2): 17-21, 2019 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-30535286

RESUMEN

A simple model for cell survival which is valid also at high dose has been developed. The model parameters can be traced back to measurable quantities from nanodosimetry. It is assumed that a cell is killed by an event which is defined by two or more double strand breaks in differently sized lethal interaction volumes (LIVs). Two different mechanisms can produce events, one-track events by one-particle track and two-track events by two. One- and two-track events are statistically independent. From the stochastic nature of cell killing which is described by the Poisson distribution, the cell survival probability was derived. The ratio of the number of one- and two-track events can be directly expressed in terms of nanodosimetry by the probability F2 that at least two ionizations are produced in a basic interaction volume (5-10 base pairs). From the model, relative biological effectiveness (RBE) can be derived which depends only on F2 and the size of the LIV. The expression for RBE fits experimental data with satisfying quality.


Asunto(s)
Supervivencia Celular/efectos de la radiación , Radiometría/métodos , Efectividad Biológica Relativa , Roturas del ADN de Doble Cadena/efectos de la radiación , Relación Dosis-Respuesta en la Radiación , Modelos Biológicos , Distribución de Poisson , Probabilidad , Dosis de Radiación , Radiobiología
9.
Radiat Environ Biophys ; 56(3): 249-254, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-28526979

RESUMEN

In view of the clinical importance of hypofractionated radiotherapy, track models which are based on multi-hit events are currently reinvestigated. These models are often criticized, because it is believed that the probability of multi-track hits is negligible. In this work, the probabilities for one- and multi-track events are determined for different biological targets. The obtained probabilities can be used with nano-dosimetric cluster size distributions to obtain the parameters of track models. We quantitatively determined the probabilities for one- and multi-track events for 100, 500 and 1000 keV electrons, respectively. It is assumed that the single tracks are statistically independent and follow a Poisson distribution. Three different biological targets were investigated: (1) a DNA strand (2 nm scale); (2) two adjacent chromatin fibers (60 nm); and (3) fiber loops (300 nm). It was shown that the probabilities for one- and multi-track events are increasing with energy, size of the sensitive target structure, and dose. For a 2 × 2 × 2 nm3 target, one-track events are around 10,000 times more frequent than multi-track events. If the size of the sensitive structure is increased to 100-300 nm, the probabilities for one- and multi-track events are of the same order of magnitude. It was shown that target theories can play a role for describing radiation-induced cell death if the targets are of the size of two adjacent chromatin fibers or fiber loops. The obtained probabilities can be used together with the nano-dosimetric cluster size distributions to determine model parameters for target theories.


Asunto(s)
Modelos Biológicos , Método de Montecarlo , Muerte Celular/efectos de la radiación , Relación Dosis-Respuesta en la Radiación , Probabilidad
10.
PLoS One ; 11(10): e0164929, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27760196

RESUMEN

BACKGROUND AND PURPOSE: When fractionation schemes for hypofractionation and stereotactic body radiotherapy are considered, a reliable cell survival model at high dose is needed for calculating doses of similar biological effectiveness. An alternative to the LQ-model is the track-event theory which is based on the probabilities for one- and two two-track events. A one-track-event (OTE) is always represented by at least two simultaneous double strand breaks. A two-track-event (TTE) results in one double strand break. Therefore at least two two-track-events on the same or different chromosomes are necessary to produce an event which leads to cell sterilization. It is obvious that the probabilities of OTEs and TTEs must somehow depend on the geometrical structure of the chromatin. In terms of the track-event theory the ratio ε of the probabilities of OTEs and TTEs includes the geometrical dependence and is obtained in this work by simple Monte Carlo simulations. MATERIALS AND METHODS: For this work it was assumed that the anchors of loop forming chromatin are most sensitive to radiation induced cell deaths. Therefore two adjacent tetranucleosomes representing the loop anchors were digitized. The probability ratio ε of OTEs and TTEs was factorized into a radiation quality dependent part and a geometrical part: ε = εion ∙ εgeo. εgeo was obtained for two situations, by applying Monte Carlo simulation for DNA on the tetranucleosomes itself and for linker DNA. Low energy electrons were represented by randomly distributed ionizations and high energy electrons by ionizations which were simulated on rays. εion was determined for electrons by using results from nanodosimetric measurements. The calculated ε was compared to the ε obtained from fits of the track event model to 42 sets of experimental human cell survival data. RESULTS: When the two tetranucleosomes are in direct contact and the hits are randomly distributed εgeo and ε are 0.12 and 0.85, respectively. When the hits are simulated on rays εgeo and ε are 0.10 and 0.71. For the linker-DNA εgeo and ε for randomly distributed hits are 0.010 and 0.073, and for hits on rays 0.0058 and 0.041, respectively. The calculated ε fits the experimentally obtained ε = 0.64±0.32 best for hits on the tetranucleosome when they are close to each other both, for high and low energy electrons. CONCLUSIONS: The parameter εgeo of the track event model was obtained by pure geometrical considerations of the chromatin structure and is 0.095 ± 0.022. It can be used as a fixed parameter in the track-event theory.


Asunto(s)
Cromatina/química , ADN/efectos de la radiación , Cromatina/efectos de la radiación , Simulación por Computador , ADN/química , Roturas del ADN de Doble Cadena , Fraccionamiento de la Dosis de Radiación , Humanos , Modelos Teóricos , Método de Montecarlo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA