Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Appl Radiat Isot ; 197: 110828, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37126950

RESUMEN

A 100-nm-thick gadolinium layer deposited on a pixelated silicon sensor was activated in a neutron field to measure the internal conversion electron (ICE) spectrum generated by neutron capture products of 155Gd and 157Gd. The experiment was performed at the ISIS neutron and muon facility, using a bespoke version of the HEXITEC spectroscopic imaging camera. Signals originating from internal conversion electrons, Auger electrons, x rays and gamma rays up to 150 keV were identified. The ICE spectrum has an energy resolution of 1.8-1.9 keV at 72 keV and shows peaks from the K, L, M, N+ ICEs of the 79.51 keV and 88.967 keV 2+-0+ gamma transitions from the first excited states in 158Gd and 156Gd, respectively, as well as the K ICEs of the 4+-2+ transitions at 181.931 keV and 199.213 keV from the respective second excited states. Spectrum analysis was performed using a convolution of a Gaussian with exponential functions at the low and high energy side as the peak shaping function. Relative ICE intensities were derived from the fitted peak areas and compared with internal conversion coefficient (ICC) values calculated from the BrIcc database. Relative to the dominant L shell contribution, the K ICE intensity conforms to BrIcc and the M, N, O+ ICE intensities are somewhat higher than expected.

2.
Phys Rev Lett ; 129(24): 244801, 2022 Dec 09.
Artículo en Inglés | MEDLINE | ID: mdl-36563240

RESUMEN

We report on a novel, noninvasive method applying Thomson scattering to measure the evolution of the electron beam energy inside a laser-plasma accelerator with high spatial resolution. The determination of the local electron energy enabled the in-situ detection of the acting acceleration fields without altering the final beam state. In this Letter we demonstrate that the accelerating fields evolve from (265±119) GV/m to (9±4) GV/m in a plasma density ramp. The presented data show excellent agreement with particle-in-cell simulations. This method provides new possibilities for detecting the dynamics of plasma-based accelerators and their optimization.

3.
Sci Rep ; 7(1): 16603, 2017 11 30.
Artículo en Inglés | MEDLINE | ID: mdl-29192189

RESUMEN

High-energy X-rays (HEX-rays) with photon energies on order of 100 keV have attractive characteristics, such as comparably low absorption, high spatial resolution and the ability to access inner-shell states of heavy atoms. These properties are advantageous for many applications ranging from studies of bulk materials to the investigation of materials in extreme conditions. Ultrafast X-ray diffraction allows the direct imaging of atomic dynamics simultaneously on its natural time and length scale. However, using HEX-rays for ultrafast studies has been limited due to the lack of sources that can generate pulses of sufficiently short (femtosecond) duration in this wavelength range. Here we show single-crystal diffraction using ultrashort ~90 keV HEX-ray pulses generated by an all-optical source based on inverse Compton scattering. We also demonstrate a method for measuring the crystal lattice spacing in a single shot that contains only ~105 photons in a spectral bandwidth of ~50% full width at half maximum (FWHM). Our approach allows us to obtain structural information from the full X-ray spectrum. As target we use a cylindrically bent Ge crystal in Laue transmission geometry. This experiment constitutes a first step towards measurements of ultrafast atomic dynamics using femtosecond HEX-ray pulses.

4.
Phys Med Biol ; 61(20): 7246-7262, 2016 10 21.
Artículo en Inglés | MEDLINE | ID: mdl-27694716

RESUMEN

In mammography, the reduction of scattered x-rays is vital due to the low contrast or small dimension of the details that are searched for. The typical method of doing so in current conventional mammography is the anti-scatter grid. The disadvantage of this method is the absorption of a proportion of the primary beam and therefore an increase in dose is required to compensate for the loss of counts. An alternative method is proposed, using quasi-monochromatic beams and a pixellated spectroscopic detector. As Compton-scattered x-rays lose energy in the scattering process, they are detected at a lower energy in the spectrum. Therefore the spectrum can be windowed around the monochromatic energy peak, removing the scattered x-rays from the image. The work presented here shows contrast improvement of up to 50% and contrast to noise ratio improvements of around 20% for scatter free imaging in comparison to full spectrum imaging. Contrast improvements of around 45% were found when comparing scatter free images to conventional polychromatic imaging for both the low contrast test object and the Rachel anthropomorphic breast phantom.

5.
Sci Rep ; 5: 15988, 2015 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-26522250

RESUMEN

A new synchrotron-based technique for elemental imaging that combines radiography and fluorescence spectroscopy has been developed and applied to study the spatial distribution of Ag, Zr and Mo in an Al alloy during heating and melting to 700, and then re-soldification. For the first time, multi-element distributions have been mapped independently and simultaneously, showing the dissolution of Ag- and Zr-rich particles during melting and the inter-dendritic segregation of Ag during re-solidification. The new technique is shown to have wide potential for metallurgical and materials science applications where the dynamics of elemental re-distribution and segregation in complex alloys is of importance.

6.
Sci Rep ; 5: 15979, 2015 Oct 30.
Artículo en Inglés | MEDLINE | ID: mdl-26514938

RESUMEN

We report the development of laboratory based hyperspectral X-ray computed tomography which allows the internal elemental chemistry of an object to be reconstructed and visualised in three dimensions. The method employs a spectroscopic X-ray imaging detector with sufficient energy resolution to distinguish individual elemental absorption edges. Elemental distributions can then be made by K-edge subtraction, or alternatively by voxel-wise spectral fitting to give relative atomic concentrations. We demonstrate its application to two material systems: studying the distribution of catalyst material on porous substrates for industrial scale chemical processing; and mapping of minerals and inclusion phases inside a mineralised ore sample. The method makes use of a standard laboratory X-ray source with measurement times similar to that required for conventional computed tomography.

7.
J Instrum ; 6(12)2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22737179

RESUMEN

We have developed a pixellated high energy X-ray detector instrument to be used in a variety of imaging applications. The instrument consists of either a Cadmium Zinc Telluride or Cadmium Telluride (Cd(Zn)Te) detector bump-bonded to a large area ASIC and packaged with a high performance data acquisition system. The 80 by 80 pixels each of 250 µm by 250 µm give better than 1 keV FWHM energy resolution at 59.5 keV and 1.5 keV FWHM at 141 keV, at the same time providing a high speed imaging performance. This system uses a relatively simple wire-bonded interconnection scheme but this is being upgraded to allow multiple modules to be used with very small dead space. The readout system and the novel interconnect technology is described and how the system is performing in several target applications.

8.
Experientia ; 40(6): 540-1, 1984 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-6723924

RESUMEN

A urinary concentrating defect was induced in Munich-Wistar rats by removing the renal pelvis from 1 kidney. This defect was partially corrected by crudely simulating the actions of pelvic wall peristalsis with a mechanical system that cyclically compressed the exposed renal papilla.


Asunto(s)
Capacidad de Concentración Renal , Médula Renal/fisiología , Pelvis Renal/fisiología , Animales , Femenino , Concentración Osmolar , Ratas , Orina
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...