Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Cardiol Young ; : 1-6, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38724470

RESUMEN

OBJECTIVE: Individuals with single ventricle physiology who are palliated with superior cavopulmonary anastomosis (Glenn surgery) may develop pulmonary arteriovenous malformations. The traditional tools for pulmonary arteriovenous malformation diagnosis are often of limited diagnostic utility in this patient population. We sought to measure the pulmonary capillary transit time to determine its value as a tool to identify pulmonary arteriovenous malformations in patients with single ventricle physiology. METHODS: We defined the angiographic pulmonary capillary transit time as the number of cardiac cycles required for transit of contrast from the distal pulmonary arteries to the pulmonary veins. Patients were retrospectively recruited from a single quaternary North American paediatric centre, and angiographic and clinical data were reviewed. Pulmonary capillary transit time was calculated in 20 control patients and compared to 20 single ventricle patients at the pre-Glenn, Glenn, and Fontan surgical stages (which were compared with a linear-mixed model). Correlation (Pearson) between pulmonary capillary transit time and haemodynamic and injection parameters was assessed using angiograms from 84 Glenn patients. Five independent observers calculated pulmonary capillary transit time to measure reproducibility (intraclass correlation coefficient). RESULTS: Mean pulmonary capillary transit time was 3.3 cardiac cycles in the control population, and 3.5, 2.4, and 3.5 in the pre-Glenn, Glenn, and Fontan stages, respectively. Pulmonary capillary transit time in the Glenn population did not correlate with injection conditions. Intraclass correlation coefficient was 0.87. CONCLUSIONS: Pulmonary angiography can be used to calculate the pulmonary capillary transit time, which is reproducible between observers. Pulmonary capillary transit time accelerates in the Glenn stage, correlating with absence of direct hepatopulmonary venous flow.

3.
medRxiv ; 2024 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-38260565

RESUMEN

Background: Individuals with single ventricle physiology who are palliated with superior cavopulmonary anastomosis (Glenn surgery) may develop pulmonary arteriovenous malformations (PAVMs). The traditional tools for PAVM diagnosis are often of limited diagnostic utility in this patient population. We sought to measure the pulmonary capillary transit time (PCTT) to determine its value as a tool to identify PAVMs in patients with single ventricle physiology. Methods: We defined the angiographic PCTT as the number of cardiac cycles required for transit of contrast from the distal pulmonary arteries to the pulmonary veins. Patients were retrospectively recruited from a single quaternary North American pediatric center, and angiographic and clinical data was reviewed. PCTT was calculated in 20 control patients and compared to 20 single ventricle patients at the pre-Glenn, Glenn, and Fontan surgical stages (which were compared with a linear-mixed model). Correlation (Pearson) between PCTT and hemodynamic and injection parameters was assessed using 84 Glenn angiograms. Five independent observers calculated PCTT to measure reproducibility (intra-class correlation coefficient). Results: Mean PCTT was 3.3 cardiac cycles in the control population, and 3.5, 2.4, and 3.5 in the pre-Glenn, Glenn, and Fontan stages, respectively. PCTT in the Glenn population did not correlate with injection conditions. Intraclass correlation coefficient was 0.87. Conclusions: Pulmonary angiography can be used to calculate the pulmonary capillary transit time, which is reproducible between observers. PCTT accelerates in the Glenn stage, correlating with absence of direct hepatopulmonary venous flow.

5.
J Cardiovasc Magn Reson ; 24(1): 32, 2022 06 02.
Artículo en Inglés | MEDLINE | ID: mdl-35650624

RESUMEN

INTRODUCTION: Cardiovascular magnetic resonance (CMR)-guided cardiac catheterization is becoming more widespread due to the ability to acquire both functional CMR measurements and diagnostic catheterization data without exposing patients to ionizing radiation. However, the real-time imaging sequences used for catheter guidance during these procedures are limited in resolution and the anatomical detail they can provide. In this study, we propose a passive catheter tracking approach which simultaneously improves catheter tracking and visualization of the anatomy. METHODS: 60 patients with congenital heart disease underwent CMR-guided cardiac catheterization on a 1.5T CMR scanner (Ingenia, Philips Healthcare, Best the Netherlands) using the Philips iSuite system. The proposed T1-overlay technique uses a commercially available heavily T1-weighted sequence to image the catheter, and overlays it on a high-resolution 3D dataset within iSuite in real-time. Suppressed tissue in the real-time images enables the use of a thick imaging slab to assist in tracking of the catheter. Improvement in catheter visualization time was compared between T1-overlay and the conventional invasive CMR (iCMR) balanced steady state free precession (bSSFP) sequence. This technique also enabled selective angiography visualization for real-time evaluation of blood flow dynamics (such as pulmonary transit time), similar to direct contrast injection under standard fluoroscopy. Estimates of pulmonary transit time using iCMR were validated using x-ray fluoroscopy in 16 patients. RESULTS: The T1-overlay approach significantly increased the time that the catheter tip was kept in view by the technologist compared to the bSSFP sequence conventionally used for iCMR. The resulting images received higher ratings for blood/balloon contrast, anatomy visualization, and overall suitability for iCMR guidance by three cardiologists. iCMR selective angiography using T1-overlay also provided accurate estimates of pulmonary transit time that agreed well with x-ray fluoroscopy. CONCLUSION: We demonstrate a new passive catheter tracking technique using the iSuite platform that improves visualization of the catheter and cardiac anatomy. These improvements significantly increase the time that the catheter tip is seen throughout the procedure. We also demonstrate the feasibility of iCMR selective angiography for the measurement of pulmonary transit time.


Asunto(s)
Imagen por Resonancia Magnética Intervencional , Cateterismo Cardíaco/métodos , Catéteres , Humanos , Imagen por Resonancia Magnética Intervencional/métodos , Espectroscopía de Resonancia Magnética , Valor Predictivo de las Pruebas
6.
Children (Basel) ; 9(4)2022 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-35455541

RESUMEN

Transcatheter device intervention is now offered as first line therapy for many congenital heart defects (CHD) which were traditionally treated with cardiac surgery. While off-label use of devices is common and appropriate, a growing number of devices are now specifically designed and approved for use in CHD. Advanced imaging is now an integral part of interventional procedures including pre-procedure planning, intra-procedural guidance, and post-procedure monitoring. There is robust societal and industrial support for research and development of CHD-specific devices, and the regulatory framework at the national and international level is patient friendly. It is against this backdrop that we review transcatheter implantable devices for CHD, the role and integration of advanced imaging, and explore the current regulatory framework for device approval.

7.
Circ Cardiovasc Interv ; 14(12): e009750, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34903033

RESUMEN

BACKGROUND: Coronary artery fistulas (CAFs) presenting in infancy are rare, and data regarding postclosure sequelae and follow-up are limited. METHODS: A retrospective review of all the neonates and infants (<1 year) was conducted from the CAF registry for CAF treatment. The CAF type (proximal or distal), size, treatment method, and follow-up angiography were reviewed to assess outcomes and coronary remodeling. RESULTS: Forty-eight patients were included from 20 centers. Of these, 30 were proximal and 18 had distal CAF; 39 were large, 7 medium, and 2 had small CAF. The median age and weight was 0.16 years (0.01-1) and 4.2 kg (1.7-10.6). Heart failure was noted in 28 of 48 (58%) patients. Transcatheter closure was performed in 24, surgical closure in 18, and 6 were observed medically. Procedural success was 92% and 94 % for transcatheter closure and surgical closure, respectively. Follow-up data were obtained in 34 of 48 (70%) at a median of 2.9 (0.1-18) years. Angiography to assess remodeling was available in 20 of 48 (41%). I. Optimal remodeling (n=10, 7 proximal and 3 distal CAF). II. Suboptimal remodeling (n=7) included (A) symptomatic coronary thrombosis (n=2, distal CAF), (B) asymptomatic coronary thrombosis (n=3, 1 proximal and 2 distal CAF), and (C) partial thrombosis with residual cul-de-sac (n=1, proximal CAF) and vessel irregularity with stenosis (n=1, distal CAF). Finally, (III) persistent coronary artery dilation (n=4). Antiplatelets and anticoagulation were used in 31 and 7 patients post-closure, respectively. Overall, 7 of 10 (70%) with proximal CAF had optimal remodeling, but 5 of 11 (45%) with distal CAF had suboptimal remodeling. Only 1 of 7 patients with suboptimal remodeling were on anticoagulation. CONCLUSIONS: Neonates/infants with hemodynamically significant CAF can be treated by transcatheter or surgical closure with excellent procedural success. Patients with distal CAF are at higher risk for suboptimal remodeling. Postclosure anticoagulation and follow-up coronary anatomic evaluation are warranted.


Asunto(s)
Anomalías de los Vasos Coronarios , Fístula Vascular , Angiografía Coronaria , Anomalías de los Vasos Coronarios/diagnóstico por imagen , Anomalías de los Vasos Coronarios/terapia , Estudios de Seguimiento , Humanos , Lactante , Recién Nacido , Sistema de Registros , Estudios Retrospectivos , Resultado del Tratamiento
8.
J Cardiovasc Magn Reson ; 23(1): 95, 2021 07 19.
Artículo en Inglés | MEDLINE | ID: mdl-34275477

RESUMEN

BACKGROUND: Cardiac catheterization and cardiovascular magnetic resonance (CMR) imaging have distinct diagnostic roles in the congenital heart disease (CHD) population. Invasive CMR (iCMR) allows for a more thorough assessment of cardiac hemodynamics at the same time under the same conditions. It is assumed but not proven that iCMR gives an incremental value by providing more accurate flow quantification. METHODS: Subjects with CHD underwent real-time 1.5 T iCMR using a passive catheter tracking technique with partial saturation pulse of 40° to visualize the gadolinium-filled balloon, CMR-conditional guidewire, and cardiac structures simultaneously to aid in completion of right (RHC) and left heart catheterization (LHC). Repeat iCMR and catheterization measurements were performed to compare reliability by the Pearson (PCC) and concordance correlation coefficients (CCC). RESULTS: Thirty CHD (20 single ventricle and 10 bi-ventricular) subjects with a median age and weight of 8.3 years (2-33) and 27.7 kg (9.2-80), respectively,  successfully underwent iCMR RHC and LHC. No catheter related complications were encountered. Time taken for first pass RHC and LHC/aortic pull back was 5.1, and 2.9 min, respectively. Total success rate to obtain required data points to complete Fick principle calculations for all patients was 321/328 (98%). One patient with multiple shunts was an outlier and excluded from further analysis. The PCC for catheter-derived pulmonary blood flow (Qp) (0.89, p < 0.001) is slightly lower than iCMR-derived Qp (0.96, p < 0.001), whereas catheter-derived systemic blood flow (Qs) (0.62, p = < 0.001) was considerably lower than iCMR-derived Qs (0.94, p < 0.001). CCC agreement for Qp at baseline (C1-CCC = 0.65, 95% CI 0.41-0.81) and retested conditions (C2-CCC = 0.78, 95% CI 0.58-0.89) were better than for Qs at baseline (C1-CCC = 0.22, 95% CI - 0.15-0.53) and retested conditions (C2-CCC = 0.52, 95% CI 0.17-0.76). CONCLUSION: This study further validates hemodynamic measurements obtained via iCMR. iCMR-derived flows have considerably higher test-retest reliability for Qs. iCMR evaluations allow for more reproducible hemodynamic assessments in the CHD population.


Asunto(s)
Imagen por Resonancia Magnética , Circulación Pulmonar , Cateterismo Cardíaco , Humanos , Espectroscopía de Resonancia Magnética , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados
9.
J Cardiovasc Magn Reson ; 23(1): 16, 2021 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-33641664

RESUMEN

BACKGROUND: Due to passive blood flow in palliated single ventricle, central venous pressure increases chronically, ultimately impeding lymphatic drainage. Early visualization and treatment of these malformations is essential to reduce morbidity and mortality. Cardiovascular magnetic resonance (CMR) T2-weighted lymphangiography (T2w) is used for lymphatic assessment, but its low signal-to-noise ratio may result in incomplete visualization of thoracic duct pathway. 3D-balanced steady state free precession (3D-bSSFP) is commonly used to assess congenital cardiac disease anatomy. Here, we aimed to improve diagnostic imaging of thoracic duct pathway using 3D-bSSFP. METHODS: Patients underwent CMR during single ventricle or central lymphatic system assessment using T2w and 3D-bSSFP. T2w parameters included 3D-turbo spin echo (TSE), TE/TR = 600/2500 ms, resolution = 1 × 1 × 1.8 mm, respiratory triggering with bellows. 3D-bSSFP parameters included electrocardiogram triggering and diaphragm navigator, 1.6 mm isotropic resolution, TE/TR = 1.8/3.6 ms. Thoracic duct was identified independently in T2w and 3D-bSSFP images, tracked completely from cisterna chyli to its drainage site, and classified based on severity of lymphatic abnormalities. RESULTS: Forty-eight patients underwent CMR, 46 of whom were included in the study. Forty-five had congenital heart disease with single ventricle physiology. Median age at CMR was 4.3 year (range 0.9-35.1 year, IQR 2.4 year), and median weight was 14.4 kg (range, 7.9-112.9 kg, IQR 5.2 kg). Single ventricle with right dominant ventricle was noted in 31 patients. Thirty-eight patients (84%) were status post bidirectional Glenn and 7 (16%) were status post Fontan anastomosis. Thoracic duct visualization was achieved in 45 patients by T2w and 3D-bSSFP. Complete tracking to drainage site was attained in 11 patients (24%) by T2w vs 25 (54%) by 3D-bSSFP and in 28 (61%) by both. Classification of lymphatics was performed in 31 patients. CONCLUSION: Thoracic duct pathway can be visualized by 3D-bSSFP combined with T2w lymphangiography. Cardiac triggering and respiratory navigation likely help retain lymphatic signal in the retrocardiac area by 3D-bSSFP. Visualizing lymphatic system leaks is challenging on 3D-bSSFP images alone, but 3D-bSSFP offers good visualization of duct anatomy and landmark structures to help plan interventions. Together, these sequences can define abnormal lymphatic pathway following single ventricle palliative surgery, thus guiding lymphatic interventional procedures.


Asunto(s)
Cardiopatías Congénitas/diagnóstico por imagen , Imagenología Tridimensional , Linfografía , Imagen por Resonancia Magnética , Conducto Torácico/diagnóstico por imagen , Adolescente , Adulto , Niño , Preescolar , Femenino , Cardiopatías Congénitas/fisiopatología , Humanos , Interpretación de Imagen Asistida por Computador , Lactante , Masculino , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Conducto Torácico/fisiopatología , Adulto Joven
10.
Ann Pediatr Cardiol ; 13(4): 327-333, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33311921

RESUMEN

BACKGROUND: There are no established criteria to decide suitability for Fontan fenestration closure. Our institution has the following criteria: an unobstructed Fontan pathway with no significant decompressing venovenous collaterals, baseline Fontan pressure ≤15 mmHg, baseline cardiac index ≥2 L/min/m2, and a decrease in cardiac index ≤20% with test occlusion of the fenestration. OBJECTIVE: The objective of the study was to review midterm outcomes following device closure of Fontan fenestration using institutional criteria. MATERIALS AND METHODS: A retrospective review was performed of patients who underwent catheterization with prior fenestrated Fontan procedure between May 2005 and January 2015. Patients were classified as those who underwent successful closure (A), had closure deferred due to failure to meet criteria (B), or were not referred for closure (C). RESULTS: There were 42 patients in Group A, 10 in Group B, and 150 in Group C. The mean Fontan pressure increased from 13.1 ± 2.1 to 14.5 ± 2.1mmHg in Group A and 14.6 ± 1.5 to 15.7 ± 2.2 mmHg in Group B (P = not significant). With test occlusion, cardiac index fell by 18.12% ± 15.68% in Group A and 33.75% ± 14.98% in Group B (P = 0.019). At a median of 46 month follow-up, oxygen saturation increased significantly from 85.15% ± 6.29% at baseline to 94.6% ± 4.43% (P < 0.001) in Group A but with no statistically significant difference in the rates of plastic bronchitis, protein-losing enteropathy, stroke, or heart transplantation between the three groups. CONCLUSIONS: Using institutional criteria, transcatheter device closure of Fontan fenestration was followed by significant increase in oxygen saturations and no statistically significant difference in morbidity or mortality between closure and nonclosure groups.

11.
Cardiol Young ; 30(11): 1730-1731, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33203499

RESUMEN

Anomalous circumflex coronary artery origin from pulmonary artery is a very rare congenital heart disease. Misdiagnosis of this condition may lead to inadequate myocardial protection during cardiopulmonary bypass surgery.


Asunto(s)
Enfermedad de la Arteria Coronaria , Anomalías de los Vasos Coronarios , Angiografía Coronaria , Anomalías de los Vasos Coronarios/diagnóstico por imagen , Anomalías de los Vasos Coronarios/cirugía , Humanos , Arteria Pulmonar/diagnóstico por imagen
12.
Cardiol Young ; 30(11): 1747-1749, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32880248

RESUMEN

Prosthetic valve thrombosis is a serious complication of prosthetic heart valves that typically requires either surgical intervention or systemic thrombolysis. In patients with contraindications to both treatment modalities, options can be limited. We describe an alternative approach to managing prosthetic valve thrombosis in an infant presenting in extremis with pulmonary haemorrhage. Using transoesophageal echocardiography and fluoroscopic guidance, we restored function to the infant's obstructed St. Jude prosthetic mitral valve through percutaneous transcatheter manipulation of the valve's leaflets.


Asunto(s)
Enfermedades de las Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Trombosis , Ecocardiografía Transesofágica , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Lactante , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Trombosis/etiología
13.
J Cardiovasc Magn Reson ; 22(1): 20, 2020 03 26.
Artículo en Inglés | MEDLINE | ID: mdl-32213193

RESUMEN

BACKGROUND: Today's standard of care, in the congenital heart disease (CHD) population, involves performing cardiac catheterization under x-ray fluoroscopy and cardiac magnetic resonance (CMR) imaging separately. The unique ability of CMR to provide real-time functional imaging in multiple views without ionizing radiation exposure has the potential to be a powerful tool for diagnostic and interventional procedures. Limiting fluoroscopic radiation exposure remains a challenge for pediatric interventional cardiologists. This pilot study's objective is to establish feasibility of right (RHC) and left heart catheterization (LHC) during invasive CMR (iCMR) procedures at our institution in the CHD population. Furthermore, we aim to improve simultaneous visualization of the catheter balloon tip, MR-conditional guidewire, and cardiac/vessel anatomy during iCMR procedures. METHODS: Subjects with CHD were enrolled in a pilot study for iCMR procedures at 1.5 T with an MR-conditional guidewire. The CMR area is located adjacent to a standard catheterization laboratory. Using the interactive scanning mode for real-time control of the imaging location, a dilute gadolinium-filled balloon-tip catheter was used in combination with an MR-conditional guidewire to obtain cardiac saturations and hemodynamics. A recently developed catheter tracking technique using a real-time single-shot balanced steady-state free precession (bSSFP), flip angle (FA) 35-45°, echo time (TE) 1.3 ms, repetition time (TR) 2.7 ms, 40° partial saturation (pSAT) pre-pulse was used to visualize the gadolinium-filled balloon, MR-conditional guidewire, and cardiac structures simultaneously. MR-conditional guidewire visualization was enabled due to susceptibility artifact created by distal markers. Pre-clinical phantom testing was performed to determine the optimum imaging FA-pSAT combination. RESULTS: The iCMR procedure was successfully performed to completion in 31/34 (91%) subjects between August 1st, 2017 to December 13th, 2018. Median age and weight were 7.7 years and 25.2 kg (range: 3 months - 33 years and 8 - 80 kg). Twenty-one subjects had single ventricle (SV) anatomy: one subject was referred for pre-Glenn evaluation, 11 were pre-Fontan evaluations and 9 post-Fontan evaluations for protein losing enteropathy (PLE) and/or cyanosis. Thirteen subjects had bi-ventricular (BiV) anatomy, 4 were referred for coarctation of the aorta (CoA) evaluations, 3 underwent vaso-reactivity testing with inhaled nitric oxide, 3 investigated RV volume dimensions, two underwent branch PA stenosis evaluation, and the remaining subject was status post heart transplant. No catheter related complications were encountered. Average time taken for first pass RHC, LHC/aortic pull back, and to cross the Fontan fenestration was 5.2, 3.0, and 6.5 min, respectively. Total success rate to obtain required data points to complete Fick principle calculations for all patients was 331/337 (98%). Subjects were transferred to the x-ray fluoroscopy lab if further intervention was required including Fontan fenestration device closure, balloon angioplasty of pulmonary arteries/conduits, CoA stenting, and/or coiling of aortopulmonary (AP) collaterals. Starting with subject #10, an MR-conditional guidewire was used in all subsequent subjects (15 SV and 10 BiV) with a success rate of 96% (24/25). Real-time CMR-guided RHC (25/25 subjects, 100%), retrograde and prograde LHC/aortic pull back (24/25 subjects, 96%), CoA crossing (3/4 subjects, 75%) and Fontan fenestration test occlusion (2/3 subjects, 67%) were successfully performed in the majority of subjects when an MR-conditional guidewire was utilized. CONCLUSION: Feasibility for detailed diagnostic RHC, LHC, and Fontan fenestration test occlusion iCMR procedures in SV and BiV pediatric subjects with complex CHD is demonstrated with the aid of an MR-conditional guidewire. A novel real-time pSAT GRE sequence with optimized FA-pSAT angle has facilitated simultaneous visualization of the catheter balloon tip, MR-conditional guidewire, and cardiac/vessel anatomy during iCMR procedures.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Cardiopatías Congénitas/diagnóstico , Imagen por Resonancia Magnética Intervencional/instrumentación , Adolescente , Adulto , Niño , Preescolar , Diseño de Equipo , Estudios de Factibilidad , Femenino , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/fisiopatología , Cardiopatías Congénitas/terapia , Humanos , Lactante , Masculino , Fantasmas de Imagen , Proyectos Piloto , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Adulto Joven
14.
Pediatr Crit Care Med ; 20(8): 728-736, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-30985609

RESUMEN

OBJECTIVES: To assess the variation in timing of left atrial decompression and its association with clinical outcomes in pediatric patients supported with venoarterial extracorporeal membrane oxygenation across a multicenter cohort. DESIGN: Multicenter retrospective study. SETTING: Eleven pediatric hospitals within the United States. PATIENTS: Patients less than 18 years on venoarterial extracorporeal membrane oxygenation who underwent left atrial decompression from 2004 to 2016. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: A total of 137 patients (median age, 4.7 yr) were included. Cardiomyopathy was the most common diagnosis (47%). Cardiac arrest (39%) and low cardiac output (50%) were the most common extracorporeal membrane oxygenation indications. Median time to left atrial decompression was 6.2 hours (interquartile range, 3.8-17.2 hr) with the optimal cut-point of greater than or equal to 18 hours for late decompression determined by receiver operating characteristic curve. In univariate analysis, late decompression was associated with longer extracorporeal membrane oxygenation duration (median 8.5 vs 5 d; p = 0.02). In multivariable analysis taking into account clinical confounder and center effects, late decompression remained significantly associated with prolonged extracorporeal membrane oxygenation duration (adjusted odds ratio, 4.4; p = 0.002). Late decompression was also associated with longer duration of mechanical ventilation (adjusted odds ratio, 4.8; p = 0.002). Timing of decompression was not associated with in-hospital survival (p = 0.36) or overall survival (p = 0.42) with median follow-up of 3.2 years. CONCLUSIONS: In this multicenter study of pediatric patients receiving venoarterial extracorporeal membrane oxygenation, late left atrial decompression (≥ 18 hr) was associated with longer duration of extracorporeal membrane oxygenation support and mechanical ventilation. Although no survival benefit was demonstrated, the known morbidities associated with prolonged extracorporeal membrane oxygenation use may justify a recommendation for early left atrial decompression.


Asunto(s)
Descompresión Quirúrgica/métodos , Oxigenación por Membrana Extracorpórea/métodos , Atrios Cardíacos/cirugía , Niño , Preescolar , Descompresión Quirúrgica/mortalidad , Oxigenación por Membrana Extracorpórea/mortalidad , Femenino , Humanos , Lactante , Unidades de Cuidado Intensivo Pediátrico/estadística & datos numéricos , Tiempo de Internación/estadística & datos numéricos , Masculino , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo
15.
Interv Cardiol Clin ; 8(1): 81-94, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30449424

RESUMEN

The quest for an ideal biodegradable stent for both adult coronary and pediatric congenital heart disease applications continues. Over the past few years, a lot of progress has been made toward development of a dedicated pediatric biodegradable stent that can be used for congenital heart disease applications. At present, there are no biodegradable stents available for use in congenital heart disease. In this article, the authors review the different biodegradable materials and their limitations and provide an overview of the current biodegradable stents being evaluated for congenital heart disease applications.


Asunto(s)
Implantes Absorbibles , Materiales Biocompatibles , Procedimientos Quirúrgicos Cardíacos/métodos , Cardiopatías Congénitas/cirugía , Stents , Humanos , Diseño de Prótesis
16.
Interv Cardiol Clin ; 6(3): 345-358, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28600089

RESUMEN

Adults with congenital heart disease are a growing population with increasingly more complex disease, in large part due to improvements in delivery of care to the pediatric population. Cardiac catheterization is an integral component of diagnosis and management in these patients. Careful attention to detail and a thorough understanding of intracardiac hemodynamics are critical to performing complete diagnostic evaluations. This article outlines the most commonly encountered lesions with guidelines for invasive assessment to help guide further therapy.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Cateterismo Cardíaco/métodos , Cardiopatías Congénitas/diagnóstico , Hemodinámica/fisiología , Monitoreo Fisiológico/métodos , Adulto , Aorta Torácica/fisiopatología , Cardiopatías Congénitas/fisiopatología , Humanos
17.
Catheter Cardiovasc Interv ; 88(6): 902-911, 2016 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-27471092

RESUMEN

BACKGROUND: Metallic endovascular stents are utilized off-label in congenital heart disease. Biodegradable stents (BDS) offer potential advantages in a growing child. We have previously reported double opposed helical (DH) BDS up to 6 mm diameter (DH-6). The objectives are to investigate the bench characteristics of larger 8 mm diameter BDS (DH-8) manufactured with increasing strut thicknesses and the inflammatory profile in a porcine model. METHODS: DH-8 were manufactured with strut thicknesses 0.10, 0.12, and 0.18 mm and mechanical testing performed. Stents were deployed into the infrarenal descending aorta (DAO) of nine minipigs. At insertion (nonsurvival = 2), 1 week (n = 2), 1 month (n = 2), and 9 months (n = 3) follow-up angiography, intravascular ultrasound and histopathology were performed. RESULTS: There was superior recoil and collapse pressure with increasing strut thickness, with 0.18 mm having 1.0% elastic recoil and collapse pressure 0.75 Atmospheres. There was good wall apposition at insertion with 5 BDS (4 DH-8 and 1 DH-6) but suboptimal in 4 as the minipigs infrarenal DAO were >8 mm (deployed at iliac bifurcation). Structural integrity was maintained in 8 BDS with 1 DH-8 collapsed at 9 months, secondary to strut damage at insertion. No thrombosis was seen. There was mild inflammation and neointimal proliferation at 1 week and 1 month, but a moderate inflammatory response at 9 months. CONCLUSIONS: DH-8 with increased strut thickness had acceptable mechanical properties at the cost of an increased inflammatory response. Miniaturization to improve delivery and further investigation on the long-term inflammatory profile of thicker struts, including through degradation, is needed. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Aorta Abdominal/cirugía , Enfermedades de la Aorta/cirugía , Stents Liberadores de Fármacos , Procedimientos Endovasculares/métodos , Angiografía , Animales , Aorta Abdominal/diagnóstico por imagen , Enfermedades de la Aorta/diagnóstico , Modelos Animales de Enfermedad , Femenino , Estudios de Seguimiento , Diseño de Prótesis , Porcinos , Porcinos Enanos , Tomografía de Coherencia Óptica , Ultrasonografía Intervencional
18.
Cardiol Young ; 26(2): 396-9, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26169191

RESUMEN

Cardiac rhabdomyomas in patients with tuberous sclerosis complex are usually detected antenatally or during infancy, with subsequent stabilisation or spontaneous regression. Development of a new cardiac rhabdomyoma beyond infancy is very rare. We report a male child who needed resection of a large rhabdomyoma in neonatal life, and then developed a new-onset rhabdomyoma at 2 years of age in a different location, needing another resection. Routine surveillance for cardiac rhabdomyomas in asymptomatic patients with tuberous sclerosis is essential.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Neoplasias Cardíacas/diagnóstico por imagen , Rabdomioma/diagnóstico por imagen , Esclerosis Tuberosa/complicaciones , Ecocardiografía , Estudios de Seguimiento , Neoplasias Cardíacas/complicaciones , Neoplasias Cardíacas/cirugía , Humanos , Recién Nacido , Masculino , Rabdomioma/complicaciones , Rabdomioma/cirugía
19.
Catheter Cardiovasc Interv ; 85(6): 1021-5, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25573324

RESUMEN

Left atrial (LA) decompression in infants with thick atrial septum placed on veno-arterial extracorporeal membrane oxygenation (ECMO) can be reliably achieved with transcatheter atrial septal (AS) stent placement. However, with myocardial recovery and ECMO decannulation the stent causes a permanent left to right shunt and surgical removal of the AS stent is usually accomplished. Transcatheter removal of AS stent is an attractive option as the advantages of LA decompression would then be coupled with the advantage of avoiding a sternotomy for surgical removal of the stent. To our knowledge, this is the first reported case of successful transcatheter retrieval of AS stent used for LA decompression in a 13-month-old child.


Asunto(s)
Cateterismo Cardíaco/métodos , Oxigenación por Membrana Extracorpórea/métodos , Defectos del Tabique Interatrial/diagnóstico por imagen , Defectos del Tabique Interatrial/terapia , Stents , Disfunción Ventricular Izquierda/terapia , Descompresión Quirúrgica/métodos , Remoción de Dispositivos/métodos , Servicio de Urgencia en Hospital , Femenino , Estudios de Seguimiento , Humanos , Lactante , Recien Nacido Prematuro , Medición de Riesgo , Resultado del Tratamiento , Ultrasonografía , Disfunción Ventricular Izquierda/diagnóstico por imagen
20.
Catheter Cardiovasc Interv ; 85(4): 629-39, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25157439

RESUMEN

OBJECTIVES: This study evaluates the feasibility of delivery and deployment of low and medium molecular weight (LMW and MMW, respectively) double-opposing helical (DH) poly-l-lactic acid biodegradable stent (BDS) in rabbit descending aorta (DAO). Secondary objectives were to assess patency and inflammation of stented vessels at 9 months and to investigate safety following intentional embolization of stent fragments in DAO. BACKGROUND: A BDS that will relieve aortic obstruction and disappears as the child grows older allowing for preservation of aortic wall elasticity and natural growth of aorta will be ideal to treat Coarctation (CoA). BDS have never been evaluated in the DAO. METHODS: Seven New Zealand white rabbits underwent implantation of DH-LMW (n = 7), DH-MMW (n = 3), and metal stents (n = 7) in DAO. BDS fragments were intentionally embolized into DAO in two rabbits. RESULTS: All stents were deployed via a 6-French sheath. Five BDS covered the origin of major DAO side branches. Angiography and intravascular ultrasound showed good stent apposition to the wall of DAO with minimal luminal loss at 9 months follow-up. All stents had minimal neointimal hyperplasia on histopathology. Adverse events included 1 death, 1 aortic aneurysm, and lower extremity ulceration due to self-mutilation in an embolization rabbit. CONCLUSIONS: Pilot study confirms the feasibility of delivery and deployment of up to 6-millimeter diameter DH BDS in rabbit DAO. Stent integrity with DH design was maintained at 9 months with minimal vessel inflammation. Potential morbidity due to embolized BD fragments cannot be ruled out and needs further evaluation.


Asunto(s)
Implantes Absorbibles , Aorta Torácica , Enfermedades de la Aorta/terapia , Arteriopatías Oclusivas/terapia , Procedimientos Endovasculares/instrumentación , Cardiopatías Congénitas/terapia , Stents , Animales , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/patología , Aortografía , Arteriopatías Oclusivas/diagnóstico , Constricción Patológica , Modelos Animales de Enfermedad , Embolia/etiología , Estudios de Factibilidad , Femenino , Migración de Cuerpo Extraño/etiología , Ácido Láctico/química , Peso Molecular , Proyectos Piloto , Poliésteres , Polímeros/química , Diseño de Prótesis , Falla de Prótesis , Conejos , Factores de Tiempo , Ultrasonografía Intervencional
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...