Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
CVIR Endovasc ; 3(1): 38, 2020 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-32743749

RESUMEN

OBJECTIVE: To evaluate the safety and efficacy of ethylene vinyl alcohol (EVOH) copolymer for the treatment of a variety of peripheral vascular pathologies. RESULTS: Between October 2010 and October 2017, 43 patients who underwent total 54 EVOH embolization procedures for the treatment of peripheral vascular pathologies were included. The cases which involved the use of EVOH for the treatment of nonvascular, neurologic, ophthalmologic, otolaryngologic or head-neck pathologies were excluded. The demographic data, technical and clinical success rates, and procedure-related details and complications were obtained. The most common indications for EVOH embolization were type II endoleaks (n = 18) and peripheral arteriovenous malformations (n = 14). The majority of cases (62.5%) used EVOH without any adjunct embolic material. The results of this study showed 100% technical success rates and 89% clinical success rates. No events of nontarget embolization or other procedure-related complications were noted. The mortality & morbidity rates were 0%. The loss to follow up rate was 16% (9 /54). The mean follow-up period was 134 days (range, 30 to 522 days). CONCLUSION: The single institutional experience supports the safety and efficacy of EVOH embolization in the treatment of various peripheral vascular conditions.

2.
J Vasc Surg Cases Innov Tech ; 6(2): 168-171, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32322768

RESUMEN

A 25-year-old man with a venous malformation (VM) along the anterior and posterolateral aspects of the right chest wall presented with progressive enlargement of VM, chest wall pain, and physical disfigurement. Because of the complexity and size of the VM, a staged multidisciplinary team approach (ie, percutaneous embolization) followed by surgical resection and tissue-skin grafting was used. The percutaneous embolization was achieved with a combination of liquid embolic agents including n-butyl cyanoacrylate for the superficial cutaneous component and ethylene vinyl alcohol copolymer for the deeper subcutaneous component of the VM. Such a combination can achieve safe occlusion of the VM, facilitate surgical resection without blood loss, and contribute to a cosmetically desirable result.

3.
J Vasc Interv Radiol ; 30(6): 781-789, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30857986

RESUMEN

Pelvic venous disorders (PeVDs) in women can present with chronic pelvic pain, lower-extremity and vulvar varicosities, lower-extremity swelling and pain, and left-flank pain and hematuria. Multiple evidence gaps exist related to PeVDs with the consequence that nonvascular specialists rarely consider the diagnosis. Recognizing this, the Society of Interventional Radiology Foundation funded a Research Consensus Panel to prioritize a research agenda to address these gaps. This paper presents the proceedings and recommendations from that Panel.


Asunto(s)
Investigación Biomédica , Dolor Crónico , Ginecología , Extremidad Inferior/irrigación sanguínea , Dolor Pélvico , Pelvis/irrigación sanguínea , Várices , Vulva/irrigación sanguínea , Dolor Crónico/diagnóstico , Dolor Crónico/fisiopatología , Dolor Crónico/terapia , Consenso , Femenino , Humanos , Dolor Pélvico/diagnóstico , Dolor Pélvico/fisiopatología , Dolor Pélvico/terapia , Valor Predictivo de las Pruebas , Pronóstico , Flujo Sanguíneo Regional , Várices/diagnóstico , Várices/fisiopatología , Várices/terapia
4.
Radiol Case Rep ; 13(3): 728-731, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29765484

RESUMEN

Enterocutaneous fistulas (ECFs) can be one of the complications found after surgical intervention for rectal cancer. Interventional modalities consisting of surgical, endoscopic, and radiological methods are often implemented to treat postoperative symptomatic complications. We present the case of 61-year-old Caucasian man who presented to us with a recent diagnosis of rectal cancer that had invaded the levators as well as anteriorly into the prostate, and who underwent low anterior resection with a diverting loop ileostomy. The patient was found to have a persistent presacral abscess due to an ECF tract. This case highlights the off-label use of ethylene-vinyl alcohol copolymer dissolved in dimethyl sulfoxide (Onyx 34) to seal an ECF.

5.
Cardiovasc Intervent Radiol ; 37(1): 85-93, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23703667

RESUMEN

PURPOSE: The purpose of this study was to determine the safety and efficacy of a new endoluminal occlusion device, ArtVentive endoluminal occlusion system (EOS), to occlude the spermatic vein in symptomatic males with varicoceles. METHODS: The ArtVentive EOS device has been developed for percutaneous, peripheral occlusion of the peripheral arterial and venous vasculature. The system is comprised of an implantable occlusion device and a delivery catheter. At present, there are two device sizes: (a) size 1 for target vessels ranging between 3.5 and 5.5 mm in diameter, and (b) size 2 for target vessels 5.5-8.5 mm in diameter. The treatment group included six adult males, ages 22-34 years. Nine target vessels were occluded. A total of 20 devices were implanted in six subjects. RESULTS: The acute occlusion rate at the end of the procedure was 100 % occurring in nine of nine vessels. The spermatic veins of all patients remained occluded on venography at 30 days follow-up. Pain scores related to varicoceles decreased in five of six patients. CONCLUSIONS: Although we recognize this study is limited, initial experience indicates that the ArtVentive EOS is a safe and effective new device for occlusion of vessels (varicoceles). The device has potential applications in other clinical conditions requiring occlusion of veins or arteries.


Asunto(s)
Embolización Terapéutica/instrumentación , Prótesis e Implantes , Cordón Espermático/irrigación sanguínea , Varicocele/terapia , Adulto , Medios de Contraste/administración & dosificación , Humanos , Masculino , Dimensión del Dolor , Flebografía , Diseño de Prótesis , Radiografía Intervencional , Resultado del Tratamiento , Venas
6.
J Endovasc Ther ; 19(4): 497-500, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22891829

RESUMEN

PURPOSE: To evaluate the feasibility and safety of using the 8-F Angio-Seal vascular closure device (VCD) to seal large-caliber (>8-F) access sites during percutaneous endovascular interventions. METHODS: A retrospective review was undertaken of 42 consecutive patients (34 men; mean age 67.8 years, range 36-94) undergoing percutaneous peripheral interventions with sheaths ranging from 9-F to 12-F and subsequent closure using 8-F Angio-Seal VCDs. Single-wall puncture (n = 48) of the common femoral artery was guided by ultrasound in 46 cases and palpation in 2. Forty procedures required therapeutic heparinization during the interventional procedure; protamine was administered in only 5. Per protocol, manual pressure was held for 15 minutes. Clinical and/or imaging follow-up was available in all cases within 3 months after the procedure. RESULTS: Immediate technical success was achieved in all cases, with hemostasis obtained within 5 minutes (no oozing or hematoma). The overall complication rate was 4.1% (2/48); one hematoma requiring surgical repair occurred 10 hours after VCD deployment. An asymptomatic pseudoaneurysm was discovered on follow-up imaging and was treated with ultrasound-guided thrombin injection with complete resolution. CONCLUSION: The use of the 8-F Angio-Seal VCD to close large-caliber arteriotomies ranging from 9-F to 12-F is feasible and safe, with a low complication rate.


Asunto(s)
Procedimientos Endovasculares , Arteria Femoral , Hemorragia/prevención & control , Técnicas Hemostáticas/instrumentación , Adulto , Anciano , Anciano de 80 o más Años , District of Columbia , Procedimientos Endovasculares/efectos adversos , Diseño de Equipo , Estudios de Factibilidad , Femenino , Hemorragia/etiología , Técnicas Hemostáticas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Presión , Punciones , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
7.
BMJ Case Rep ; 20122012 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-22684830

RESUMEN

A patient presented with abdominal pain, hypotension and a retroperitoneal haematoma 5 days after transplant nephrectomy. Vascular injury sustained from transplant nephrectomy was repaired using endovascular techniques. Several known advantages to endovascular repair include: (1) intervention by a less invasive approach, (2) performance under local anaesthesia, (3) association with a shorter hospital stay and (4) reduction in morbidity and mortality. There were no infectious complications to the stent or the patient despite positive blood cultures obtained upon admission to the hospital. It was concluded that endovascular repair of an iliac artery used for kidney transplantation had favourable outcomes with respect to infection control and use of the vessel for future anastomosis.


Asunto(s)
Prótesis Vascular , Procedimientos Endovasculares/métodos , Hematoma/cirugía , Arteria Ilíaca/cirugía , Nefrectomía/efectos adversos , Stents , Recolección de Tejidos y Órganos/efectos adversos , Angiografía , Hematoma/diagnóstico , Hematoma/etiología , Humanos , Masculino , Persona de Mediana Edad , Espacio Retroperitoneal , Recolección de Tejidos y Órganos/métodos , Tomografía Computarizada por Rayos X
8.
Gastrointest Endosc Clin N Am ; 21(4): 697-705, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21944419

RESUMEN

The use of catheter-based techniques to treat upper gastrointestinal hemorrhage has evolved considerably over the past few decades. At present, the state-of-the-art interventional suites provide optimal imaging. Coupled with advanced catheter technology, the two may be used to manage and treat the patient with acute upper gastrointestinal hemorrhage. This article summarizes these techniques and, when possible, compares them with other methods such as surgery and endoscopy. The specific role of transcatheter embolotherapy is highlighted, alongside an additional discussion on pharmacologic infusion of vasopressin.


Asunto(s)
Angiografía/métodos , Embolización Terapéutica/métodos , Hemorragia Gastrointestinal/diagnóstico por imagen , Hemorragia Gastrointestinal/terapia , Radiografía Intervencional/métodos , Tracto Gastrointestinal Superior , Endoscopía Gastrointestinal , Hemorragia Gastrointestinal/etiología , Humanos , Tracto Gastrointestinal Superior/irrigación sanguínea , Vasopresinas/administración & dosificación
9.
Obes Surg ; 21(10): 1580-4, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21088928

RESUMEN

BACKGROUND: Bariatric patients are at significant risk for venous thromboembolism (VTE) and a subset may benefit from retrievable inferior vena cava filters (rIVCFs). Optimal VTE prophylaxis and a consensus on factors which make bariatric patients high risk have not been established. This study describes our experience with the use of rIVCFs in combination with chemoprophylaxis for high-risk bariatric surgery patients. METHODS: A retrospective review was performed of high-risk patients bariatric surgery patients. Patients with a hypercoaguable condition, prior history of VTE, body mass index (BMI) > 55 kg/m(2), and severe immobility were considered high risk. Patients underwent rIVCF placement and standard chemoprophylaxis. A venogram was performed at retrieval. RESULTS: Forty-four patients, age of 48 ± 12 years and BMI of 58.4 ± 9.4 kg/m(2) underwent gastric bypass with rIVCF placement. Follow-up was 204 days. One patient had a preoperative deep venous thrombosis (DVT). All patients received chemoprophylaxis and rIVCF placement. Indications for rIVCF were BMI (68%), prior VTE (30%), and immobility (2%). The operation was performed laparoscopically in all patients, and the mean operative time was 106.1 ± 21.6 min and length of stay was 3.1 ± 1.2 days. Postoperative venous duplex revealed two DVTs (5%). Retrieval was successful in 28 patients. No significant thrombus was found on venogram. Two minor complications of filter placement occurred. One mortality occurred due to MI, and no pulmonary emboli were clinically evident. CONCLUSIONS: rIVCFs in our cohort of high-risk bariatric surgery patients was associated with an acceptably low incidence of DVT (5%) and no clinically evident PE. Despite safe removal after long dwell times, previous data suggest that rIVCFs are associated with a higher incidence of VTE. Thus, filters, if placed, should be removed once the risk of VTE has passed. Larger multicenter studies are needed to truly identify long-term safety and efficacy of rIVCFs.


Asunto(s)
Cirugía Bariátrica/efectos adversos , Obesidad Mórbida/complicaciones , Filtros de Vena Cava , Tromboembolia Venosa/prevención & control , Adulto , Anticoagulantes/administración & dosificación , Índice de Masa Corporal , Ambulación Precoz , Femenino , Heparina/administración & dosificación , Humanos , Inyecciones Subcutáneas , Laparoscopía , Masculino , Persona de Mediana Edad , Obesidad Mórbida/cirugía , Estudios Retrospectivos , Medias de Compresión , Tromboembolia Venosa/etiología
11.
J Vasc Interv Radiol ; 21(8): 1173-84, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20598570

RESUMEN

PURPOSE: To evaluate the safety and effectiveness of the retrievable Option inferior vena cava (IVC) filter in patients at risk for pulmonary embolism (PE). MATERIALS AND METHODS: This was a prospective, multicenter, single-arm clinical trial. Subjects (N = 100) underwent implantation of the IVC filter and were followed for 180 days; subjects whose filters were later removed were followed for 30 days thereafter. The primary objective was to determine whether the one-sided lower limit of the 95% CI for the observed clinical success rate was at least 80%. Clinical success was defined as technical success (deployment of the filter such that it was judged suitable for mechanical protection from PE) without subsequent PE, significant filter migration or embolization, symptomatic caval thrombosis, or other complications. RESULTS: Technical success was achieved in 100% of subjects. There were eight cases of recurrent PE, two cases of filter migration (23 mm), and three cases of symptomatic caval occlusion/thrombosis (one in a subject who also experienced filter migration). No filter embolization or fracture occurred. Clinical success was achieved in 88% of subjects; the one-sided lower limit of the 95% CI was 81%. Retrieval was successful at a mean of 67.1 days after implantation (range, 1-175 d) for 36 of 39 subjects (92.3%). All deaths (n = 17) and deep vein thromboses (n = 18) were judged to have resulted from preexisting or intercurrent illnesses or interventions and unrelated to the filter device; all deaths were judged to be unrelated to PE. CONCLUSIONS: Placement and retrieval of the Option IVC filter were performed safely and with high rates of clinical success.


Asunto(s)
Embolia Pulmonar/prevención & control , Tromboembolia/terapia , Filtros de Vena Cava , Trombosis de la Vena/terapia , Adulto , Anciano , Remoción de Dispositivos , Femenino , Migración de Cuerpo Extraño/etiología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Embolia Pulmonar/etiología , Recurrencia , Tromboembolia/complicaciones , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos , Filtros de Vena Cava/efectos adversos , Trombosis de la Vena/complicaciones
12.
J Vasc Interv Radiol ; 20(11): 1449-53, 2009 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-19875062

RESUMEN

PURPOSE: To assess the technical success and safety for retrieval of the G2 filter. MATERIALS AND METHODS: The authors performed a prospective, multicenter study of 100 patients with temporary indication for caval interruption. Patients were enrolled consecutively between December 2005 and July 2006. There were 67 men and 33 women with a mean age of 52.1 years (range, 19-82 years). Indications for filter placement were trauma (n = 56), perioperative risk (n = 16), and medical indications (n = 28). Forty-two patients had venous thromboembolism at filter placement. Fifty-eight filters were placed prophylactically. RESULTS: Retrieval was attempted in 61 patients. Fifty-eight of the 61 filters (95%) were successfully retrieved after a mean dwell time of 140 days (range, 5-300 days). In all failed retrievals, the filter tip was against the caval wall. There was no difference in dwell times between successful and unsuccessful retrievals. Although there were no cases of cranial migration, caudal migrations were observed in 12% of cases (10 of 85 patients with a complete data set). Other device-related complications included filter fracture (1/85, 1.2%), filter tilt of more than 15 degrees (15/85, 18%), and leg penetration (16/61, 26%). The recurrent pulmonary embolism (PE) rate was 2%, with no PE in the 30-day period after filter retrieval. CONCLUSIONS: Retrieval of the Recovery G2 filter was safe and successful in most patients. Caudal migration was observed as an unexpected phenomenon.


Asunto(s)
Remoción de Dispositivos/estadística & datos numéricos , Falla de Prótesis , Embolia Pulmonar/epidemiología , Embolia Pulmonar/prevención & control , Sistema de Registros/estadística & datos numéricos , Filtros de Vena Cava/estadística & datos numéricos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Incidencia , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Terapéutica , Estados Unidos/epidemiología , Adulto Joven
13.
J Vasc Interv Radiol ; 19(3): 372-6, 2008 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-18295696

RESUMEN

PURPOSE: To evaluate the efficacy of thrombolysis with the EndoWave peripheral infusion system in the treatment of patients with massive pulmonary embolism (PE) as compared to patients treated with catheter-directed thrombolysis. MATERIALS AND METHODS: Ten patients (five men and five women; age range, 31-85 years; mean age, 54.20 years) with massive acute PE (17 lesions) were treated with ultrasonography (US)-assisted catheter-directed thrombolysis with the Endowave system. All patients had hypoxia and dyspnea. No patient had contraindication for thrombolysis. Angiographic findings, duration of lysis, dose of thrombolytics used, and procedural complications were recorded. Thrombolytics used were urokinase, tissue-type plasminogen activator (tPA), and Reteplase. RESULTS: Complete thrombus removal was achieved in 13 of the 17 lesions (76%), near complete thrombolysis was achieved in three lesions (18%), and partial thrombolysis was achieved in one lesion (6%). The mean time of thrombolysis was 24.76 hours +/- 8.44 (median, 24 hours). The mean dose of tPA used for the Endowave group was 0.88 mg/h +/- 0.19 (13 lesions). CONCLUSIONS: US-assisted catheter-directed thrombolysis is an effective method for treating massive thrombolysis. It has the potential to shorten the time of lysis and lower the dose of thrombolytics.


Asunto(s)
Embolia Pulmonar/tratamiento farmacológico , Terapia Trombolítica/métodos , Enfermedad Aguda , Adulto , Anciano , Cateterismo , Femenino , Fibrinolíticos/administración & dosificación , Humanos , Masculino , Persona de Mediana Edad , Embolia Pulmonar/diagnóstico por imagen , Proteínas Recombinantes/administración & dosificación , Estudios Retrospectivos , Terapia Trombolítica/instrumentación , Activador de Tejido Plasminógeno/administración & dosificación , Ultrasonografía , Activador de Plasminógeno de Tipo Uroquinasa/administración & dosificación
14.
Semin Intervent Radiol ; 25(1): 20-6, 2008 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21326489

RESUMEN

Approximately 140,000 to 200,000 patients die as a result of pulmonary embolism in the United States each year. If the diagnosis is made and therapy initiated, the mortality rate drops to 8%. Vena cava filters play a role in the management of patients with thromboembolic disease. Deployment of "optional" filters is changing practice paradigms.

15.
Semin Intervent Radiol ; 25(4): 361-8, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21326577

RESUMEN

The diagnosis of pelvic congestion syndrome (PCS) continues to challenge all physicians involved especially those in such specialties as anesthesia, gastroenterology, general surgery, obstetrics and gynecology, and interventional radiology. When other pelvic pathology is ruled out, an interventional radiologist may be consulted for additional evaluation and treatment of PCS. A heightened awareness and clinical suspicion for the specific symptomatology and associated findings may bring about a more rapid progression toward treatment. For most interventional radiologists who treat PCS patients, magnetic resonance imaging/MR venography (MRI/MRV), diagnostic venogram, and embolotherapy are at the center of diagnosis and treatment of PCS.

18.
J Vasc Interv Radiol ; 17(2 Pt 1): 289-97, 2006 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-16517774

RESUMEN

PURPOSE: To evaluate the long-term clinical outcome of transcatheter embolotherapy in women with chronic pelvic pain caused by ovarian and pelvic varices. MATERIALS AND METHODS: The study population included consecutive patients referred to a tertiary-care interventional radiology service from 1998 to 2003 because of a high degree of clinical suspicion of pelvic and ovarian varices. Visual analog scales and questionnaires during clinic visits were used to measure pain perception levels. Basal female hormonal levels were obtained and compared. RESULTS: Of 131 patients referred (mean age, 34.0 years+/-12.5), percutaneous transfemoral venography confirmed the presence of ovarian varices in 127 (97.0%), all of whom were treated with embolotherapy. Internal iliac embolotherapy was performed in 108 of 127 patients (85.0%). Ninety-seven patients completed long-term clinical follow-up (mean 45 months+/-18). The mean pelvic pain level had improved significantly from 7.6+/-1.8 before embolotherapy to 2.9+/-2.8 after embolotherapy (P<.0001). Significant improvement in each category of specific symptoms was also noted (P<.0001). Overall, 83% of the patients exhibited clinical improvement at long-term follow-up, 13% had no significant change, and 4% exhibited worsened condition. No significant change was noted in hormone levels after embolotherapy. Two successful pregnancies were noted after ovarian and pelvic vein embolotherapy. CONCLUSION: Direct venographic evaluation with embolotherapy can achieve significant improvement in pain perception levels in patients with chronic pelvic pain caused by pelvic venous congestion.


Asunto(s)
Embolización Terapéutica/métodos , Dolor Pélvico/terapia , Várices/terapia , Adulto , Enfermedad Crónica , Femenino , Humanos , Imagen por Resonancia Magnética , Ovario/irrigación sanguínea , Dolor Pélvico/diagnóstico , Dolor Pélvico/etiología , Pelvis/irrigación sanguínea , Radiografía Intervencional , Índice de Severidad de la Enfermedad , Síndrome , Resultado del Tratamiento , Várices/complicaciones , Várices/diagnóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...