Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Sci Rep ; 13(1): 10303, 2023 06 26.
Artículo en Inglés | MEDLINE | ID: mdl-37365255

RESUMEN

We aimed to determine the prevalence of radiological temporal bone features that in previous studies showed only a weak or an inconsistent association with the clinical diagnosis of Meniere's disease (MD), in two groups of MD patients (n = 71) with previously established distinct endolymphatic sac pathologies; i.e. the group MD-dg (ES degeneration) and the group MD-hp (ES hypoplasia). Delayed gadolinium-enhanced MRI and high-resolution CT data were used to determine and compare between and within (affected vs. non-affected side) groups geometric temporal bone features (lengths, widths, contours), air cell tract volume, height of the jugular bulb, sigmoid sinus width, and MRI signal intensity alterations of the ES. Temporal bone features with significant intergroup differences were the retrolabyrinthine bone thickness (1.04 ± 0.69 mm, MD-hp; 3.1 ± 1.9 mm, MD-dg; p < 0.0001); posterior contour tortuosity (mean arch-to-chord ratio 1.019 ± 0.013, MD-hp; 1.096 ± 0.038, MD-dg; p < 0.0001); and the pneumatized volume (1.37 [0.86] cm3, MD-hp; 5.25 [3.45] cm3, MD-dg; p = 0.03). Features with differences between the affected and non-affected sides within the MD-dg group were the sigmoid sinus width (6.5 ± 1.7 mm, affected; 7.6 ± 2.1 mm, non-affected; p = 0.04) and the MRI signal intensity of the endolymphatic sac (median signal intensity, affected vs. unaffected side, 0.59 [IQR 0.31-0.89]). Radiological temporal bone features known to be only weakly or inconsistently associated with the clinical diagnosis MD, are highly prevalent in either of two MD patient groups. These results support the existence of diverse-developmental and degenerative-disease etiologies manifesting with distinct radiological temporal bone abnormalities.


Asunto(s)
Saco Endolinfático , Enfermedad de Meniere , Humanos , Enfermedad de Meniere/diagnóstico por imagen , Enfermedad de Meniere/etiología , Hueso Temporal/anomalías , Radiografía , Saco Endolinfático/patología , Imagen por Resonancia Magnética/efectos adversos
2.
HNO ; 70(12): 891-902, 2022 Dec.
Artículo en Alemán | MEDLINE | ID: mdl-36269381

RESUMEN

BACKGROUND: Perfect hearing is crucial to the practice of various professions, such as instrument makers, musicians, sound engineers, and other professions not related to music, such as sonar technicians. For people of these occupational groups, we propose the term "professional ear user" (PEU) in analogy to "professional voice user". PEUs have special requirements for their hearing health, as they have well-known above-average auditory perceptual abilities on which they are professionally dependent. OBJECTIVE: The purpose of this narrative review is to summarize selected aspects of the prevention, diagnosis, and treatment of ear disorders in PEUs. RESULTS AND CONCLUSION: Prevention of hearing disorders and other ear diseases includes protection from excessive sound levels, avoidance of ototoxins and nicotine, and a safe manner of cleaning the outer auditory canal. Diagnosing hearing disorders in PEUs can be challenging, since subclinical but relevant changes in hearing cannot be reliably objectified by conventional audiometric methods. Moreover, the fact that a PEU is affected by an ear disease may influence treatment decisions. Further, physicians must be vigilant for non-organic ear diseases in PEUs. Lastly, measures to promote comprehensive ear health in PEUs as part of an educational program and to maintain ear health by means of a specialized otolaryngology service are discussed. In contrast to existing concepts, we lay the attention on the entirety of occupational groups that are specifically dependent on their ear health in a professional setting. In this context, we suggest avoiding a sole focus on hearing disorders and their prevention, but rather encourage the maintenance of a comprehensive ear health.


Asunto(s)
Enfermedades del Oído , Pérdida Auditiva Provocada por Ruido , Música , Enfermedades Profesionales , Humanos , Pérdida Auditiva Provocada por Ruido/diagnóstico , Enfermedades Profesionales/diagnóstico , Enfermedades Profesionales/prevención & control , Audiometría
3.
Otol Neurotol ; 43(9): e984-e991, 2022 10 01.
Artículo en Inglés, Alemán | MEDLINE | ID: mdl-36006776

RESUMEN

OBJECTIVE: To determine the prevalence of endolymphatic hydrops (EH) in cochlear implant (CI) candidates with idiopathic profound sensorineural hearing loss (SNHL) and its influence on the preservation of audiovestibular function after cochlear implantation. STUDY DESIGN: Prospective case series. SETTING: Tertiary referral center. PATIENTS: CI candidates with idiopathic progressive SNHL, but without classic EH-associated symptoms. INTERVENTIONS: Delayed intravenous gadolinium-enhanced inner ear fluid-attenuated inversion recovery magnetic resonance imaging as well as pure-tone audiograms, video head impulse tests, and vestibular evoked myogenic potentials before and 4 weeks after cochlear implantation. MAIN OUTCOME MEASURES: Prevalence of EH before cochlear implantation, audiovestibular function before and after surgery in hydropic and nonhydropic ears. RESULTS: Thirty-two ears in 16 CI candidates were included. Nine ears (28%) with EH were detected. Although preoperative hearing thresholds, utricular function, and semicircular canal function were not different between the two groups, saccular function was reduced in hydropic ears. Ten subjects received a unilateral CI. Of these, 3 (30%) showed EH on the implanted side. There was no difference regarding postoperative hearing loss between the two groups, but the results point toward a higher vulnerability of hydropic ears with respect to loss of otolith function after cochlear implantation. CONCLUSIONS: This is the first study showing that EH can be assumed in about one third of CI candidates with idiopathic profound SNHL, but no classic EH-associated symptoms. Preliminary results suggest that EH has no influence on the preservation of cochlear function but could be a risk factor for loss of otolith function after cochlear implantation.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Hidropesía Endolinfática , Pérdida Auditiva Sensorineural , Hidropesía Endolinfática/diagnóstico por imagen , Hidropesía Endolinfática/epidemiología , Hidropesía Endolinfática/cirugía , Gadolinio , Pérdida Auditiva Sensorineural/epidemiología , Pérdida Auditiva Sensorineural/cirugía , Humanos , Imagen por Resonancia Magnética/métodos , Prevalencia , Canales Semicirculares
4.
Cancers (Basel) ; 14(16)2022 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-36010847

RESUMEN

To assess the incidence and severity of changes in hearing threshold in patients undergoing high-dose pencil-beam-scanning proton therapy (PBS-PT). This retrospective cohort study included fifty-one patients (median 50 years (range, 13-68)) treated with PBS-PT for skull base tumors. No chemotherapy was delivered. Pure tone averages (PTAs)were determined before (baseline) and after PBS-PT as the average hearing thresholds at frequencies of 0.5, 1, 2, and 4 kHz. Hearing changes were calculated as PTA differences between pre-and post-PBS-PT. A linear mixed-effects model was used to assess the relationship between the PTA at the follow-up and the baseline, the cochlea radiation dose intensity, the increased age, and the years after PBS-PT. Included patients were treated for chordoma (n = 24), chondrosarcoma (n = 9), head and neck tumors (n = 9), or meningioma (n = 3), with a mean tumor dose of 71.1 Gy (RBE) (range, 52.0-77.8), and a mean dose of 37 Gy (RBE) (range, 0.0-72.7) was delivered to the cochleas. The median time to the first follow-up was 11 months (IQR, 5.5-33.7). The PTA increased from a median of 15 dB (IQR 10.0-25) at the baseline to 23.8 (IQR 11.3-46.3) at the first follow-up. In the linear mixed-effect model, the baseline PTA (estimate 0.80, 95%CI 0.64 to 0.96, p ≤ 0.001), patient's age (0.30, 0.03 to 0.57, p = 0.029), follow-up time (2.07, 0.92 to 3.23, p ≤ 0.001), and mean cochlear dose in Gy (RBE) (0.34, 0.21 to 0.46, p ≤ 0.001) were all significantly associated with an increase in PTA at follow-up. The applied cochlear dose and baseline PTA, age, and time after treatment were significantly associated with hearing loss after proton therapy.

5.
J Clin Med ; 11(7)2022 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-35407420

RESUMEN

BACKGROUND: To evaluate the long-term audiological outcomes combined with the Hearing Implant Sound Quality Index (HISQUI) after Vibrant Soundbridge (VSB) implantation. METHODS: Prospective recall cohort study of patients who received a VSB in a tertiary academic medical center between 1996 and 2017. Air conduction (AC) and bone conduction (BC), sound field thresholds in aided and unaided conditions, and speech discrimination in noise (Oldenburger sentence test) were measured. Postoperative results were compared with preoperative audiograms. Furthermore, the HISQUI was evaluated. RESULTS: Ten patients (eleven implants) were included, the mean follow up period was nine years. The mean AC threshold preoperatively was between 63 and 70 dB, and the BC was between 38 and 49 dB from 500 to 4000 Hz. In the free-field audiogram, the mean threshold was between 61 and 77 dB unaided vs. between 28 and 52 dB in the aided condition. The average signal to noise ratio (SNR) in the Oldenburger sentence test in the unaided condition was 10 dB ± 6.7 dB vs. 2 dB ± 5.4 dB in the aided condition. Three patients reported a good to very good hearing result, four patients a moderate, and three patients a poor hearing result. There was a significant association between the years of implantation and the HISQUI (p = 0.013), as well as a significant decrease by 14 HISQUI points per 10 dB SPL decline (SE 5.2, p = 0.023). There was a significant difference between the change of BC over the years and the HISQUI, as well as the number of years after implantation and the HISQUI. On average, per dB decrease in BC, the HISQUI decreases by 1.4 points, and every year after implantation the HISQUI decreases by 2.7 points. CONCLUSIONS: The aided threshold in free field and speech understanding in noise improved significantly with VSB. An increase over time of BC thresholds was observed as well as a decrease in HISQUI score. This decrease in BC thresholds over time may be due to presbycusis. Therefore, monitoring of these patients over time should be considered to discuss alternative hearing rehabilitation measures in a timely manner.

6.
Int J Audiol ; 61(8): 678-685, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-34097554

RESUMEN

OBJECTIVE: To investigate transcranial transmission (TT) and the dampening effect of the skin in patients and cadaver heads. DESIGN: In patients a pure tone bone conduction audiogram for ipsilateral and contralateral stimulation was performed. The TT was defined as the difference between ipsilateral and contralateral hearing thresholds. In cadaver heads ipsilateral and contralateral promontory motion was measured using a three-dimensional Laser Doppler Vibrometer system. STUDY SAMPLE: Seven single-sided deaf patients fitted with a Baha® Connect, fifteen single-sided deaf patients without a bone conduction hearing aid and five Thiel-embalmed cadaver heads were included. RESULTS: The TT decreased with increasing frequency in patients and cadaver heads. No significant difference was seen between patients and cadaver heads. Measurements on patients and cadaver heads showed increasing skin attenuation with increasing frequency. However, the dampening effect was 3-12 dB higher in patients than in cadavers at all frequencies. CONCLUSION: The TT was not significantly different for patients compared to cadaver heads. The value of promontory motion to estimate TT in patients need to be further evaluated. The skin attenuates a BC stimulus by 10-20 dB in patients and by a smaller amount in cadaver heads, probably due to changes in the properties of the Thiel-conserved skin.


Asunto(s)
Conducción Ósea , Audífonos , Conducción Ósea/fisiología , Cadáver , Audición , Humanos , Sonido , Vibración
7.
Otol Neurotol ; 43(2): e181-e190, 2022 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-34772884

RESUMEN

OBJECTIVE: To assess the prevalence and implications of phase changes in extracochlear electrocochleography (ECochG) recordings during cochlear implantation. MATERIALS AND METHODS: Extracochlear ECochG recordings were performed before and after insertion of the cochlear implant (CI) electrode by a recording electrode placed on the promontory. Acoustic stimuli were tone bursts at 250, 500, 750, and 1,000 Hz. The pure tone average (PTA) was determined before and approximately 4 weeks after surgery. RESULTS: Extracochlear ECochG recordings in 69 ears of 68 subjects were included. At 250 Hz, the mean phase change was 43° (n = 50, standard deviation (SD) 44°), at 500 Hz 36° (n = 64, SD 36°), at 750 Hz 33° (n = 42, SD 39°), and at 1,000 Hz 22° (n = 54, SD 27°). Overall, in 48 out of 210 ECochG recordings a phase change of ≥45° (23%) was detectable. Ears with an amplitude drop >3 dB and a phase change ≥45° (n = 3) had a complete or near complete loss of residual cochlear function in all cases. A phase change of ≥90° in one recording was not associated with a larger amplitude change of the ECochG signal (1.9 dB vs. -0.9 dB, p = 0.1052, n = 69), but with a significantly larger postoperative hearing loss (17 dB vs. 26 dB, p = 0.0156, n = 69). CONCLUSIONS: Phase changes occur regularly in extracochlear ECochG recordings during cochlear implantation. Phase changes of ≥90° with or without amplitude changes in the ECochG signal are associated with a larger postoperative hearing loss and could therefore represent an independent marker for cochlear trauma or changes of inner ear mechanics relevant for the postoperative hearing outcome.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Sordera , Pérdida Auditiva , Audiometría de Respuesta Evocada , Cóclea , Sordera/cirugía , Pérdida Auditiva/diagnóstico , Pérdida Auditiva/cirugía , Humanos
8.
Otol Neurotol ; 42(8): 1129-1135, 2021 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-34191788

RESUMEN

OBJECTIVE: To analyze the cost effectiveness of cochlear implantation (CI) for the treatment of single-sided deafness (SSD). STUDY DESIGN: Cost-utility analysis in an adapted Markov model. SETTING: Adults with single-sided deafness in a high-income country. INTERVENTION: Unilateral CI was compared with no intervention. MAIN OUTCOME MEASURE: Incremental cost-effectiveness ratios were compared with different cost-effectiveness thresholds ($10,000 to $150,000) for different age, sex, and cost combinations. The calculations were based on the quality-adjusted life year (QALY), national life expectancy tables, and different cost settings. The health utility values for the QALY were either directly collected from published data, or, derived from published data using a regression model of multiple utility indices (regression estimate). RESULTS: The regression estimate showed an increase of the health utility value from 0.62 to 0.74 for SSD patients who underwent CI. CI for SSD was cost effective for women up to 64 years ($50,000 per-QALY threshold), 80 years ($100,000 per-QALY threshold), and 86 years ($150,000 per-QALY threshold). For men, these values were 58, 77, and 84, respectively. Changing the discount rate by up to 5% further increased the cutoff ages up to 5 years. A detailed cost and age sensitivity analysis is presented and allows testing for cost effectiveness in local settings worldwide. CONCLUSIONS: CI is a cost-effective option to treat patients with SSD.


Asunto(s)
Implantación Coclear , Sordera , Adulto , Análisis Costo-Beneficio , Sordera/cirugía , Femenino , Humanos , Esperanza de Vida , Masculino , Años de Vida Ajustados por Calidad de Vida
9.
J Clin Med ; 10(11)2021 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-34071847

RESUMEN

A retrospective analysis to quantify age-related changes of the incudo-malleolar joint (IMJ) and incudo-stapedial joint (ISJ), and to analyse changes in the air-bone gap (ABG) with age, was performed. Defined histologic parameters of 153 IMJ and 106 ISJ from subjects aged from birth to 70 years were correlated to age. Additionally, audiograms of 1760 ears of 974 other subjects aged 20 to 80 years were retrospectively analysed and the ABG was correlated to age. The joint space (age group from 0 to 10 compared to 61 to 70 years) became significantly wider with age (IMJ: from a mean of 44 µm to 100 µm, p < 0.001; ISJ: from a mean of 28 µm to 69 µm, p < 0.009. The thickness of cartilage of the incus decreased in the first 20 years of life (IMJ, from a mean of 88 µm to 65 µm, p < 0.01; ISJ: from a mean of 44 µm to 35 µm, p < 0.01). The ABGs of younger ears (20-40 years) was significantly larger at 500 Hz compared to older ears (60-80 years) by 2-4 dB, while it was significantly smaller by 3-5 dB at 4000 Hz (p < 0.0017). Interindividual variations in all age groups were large for both analyses. The increased joint spaces could potentially reduce the stiffness in the joints and explain the increase in ABG at 4000 Hz and the drop at 500 Hz. While the average change is small and of minimal clinical relevance, a larger increase of ABG with age is seen in some subjects.

10.
Front Surg ; 8: 638057, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33681285

RESUMEN

Introduction: The Clavien-Dindo classification is a broadly accepted surgical complications classification system, grading complications by the extent of therapy necessary to resolve them. A drawback of the method is that it does not consider why the patient was operated on primarily. Methods: We designed a novel index based on Clavien-Dindo but with respect to the surgical indication. We surveyed an international panel of otolaryngologists who filled out a questionnaire with 32 real case-inspired scenarios. Each case was graded for the surgical complication, surgical indication, and a subjective rating whether the complication was acceptable or not. Results: Seventy-seven otolaryngologists responded to the survey. Mean subjective rating and surgical complication grading for each scenario showed an inverse correlation (r 2 = 0.147, p = 0.044). When grading the surgical complication with respect to the surgical indication, the correlation with the subjective rating increased dramatically (r 2 = 0.307, p = 0.0022). Conclusion: We describe a novel index grading surgical complications with respect to the surgical indication. In our survey, most respondents judged a complication as acceptable or not according to its grade but kept in mind the surgical indication. This subjective judgment could be quantified with our novel index.

11.
J Clin Med ; 10(2)2021 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-33477270

RESUMEN

The reliable prediction of cochlear implant (CI) speech perception outcomes is highly relevant and can facilitate the monitoring of postoperative hearing performance. To date, multiple audiometric, demographic, and surgical variables have shown some degree of correlation with CI speech perception outcomes. In the present study, postsurgical acoustic and electric hearing thresholds that are routinely assessed in clinical practice were compared to CI speech perception outcomes in order to reveal possible markers of postoperative cochlear health. A total of 237 CI recipients were included in this retrospective monocentric study. An analysis of the correlation of postoperative pure-tone averages (PTAs) and electric CI fitting thresholds (T-/C-levels) with speech perception scores for monosyllabic words in quiet was performed. Additionally, a correlation analysis was performed for postoperative acoustic thresholds in intracochlear electrocochleography (EcochG) and speech recognition scores in a smaller group (n = 14). The results show that neither postoperative acoustic hearing thresholds nor electric thresholds correlate with postoperative speech perception outcomes, and they do not serve as independent predictors of speech perception outcomes. By contrast, the postoperative intracochlear total EcochG response was significantly correlated with speech perception. Since the EcochG recordings were only performed in a small population, a large study is required to clarify the usefulness of this promising predictive parameter.

12.
Cochlear Implants Int ; 22(2): 103-110, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33148136

RESUMEN

Objective: To investigate impedance change of cochlear implant (CI) electrodes from CochlearTM in patients with straight and precurved electrodes, and to determine if impedance change of the basal electrodes are indicative for cochlear electrode migration. Methods: Retrospective case series at an academic tertiary referral center. Five hundred sixty patients (414 precurved, 146 straight) received a CI from CochlearTM between January 2010 and August 2018. Electrode impedance measured intraoperatively and during follow-up has been assessed. In case of impedance change of the 3 most basal electrodes a computer tomography (CT) scan has been performed. Cochlear position of the electrode array has been determined and compared to the one day postoperative electrode position (plain radiography). Results: Changes in electrode impedance in the basal electrodes occurred in 2.1% ears (n = 12). CT scan was available in 9 patients and revealed a migration of the electrode array in 6 patients. Straight electrode types showed a significantly higher migration rate than precurved electrode types (4.1% vs 0%). Conclusions: Electrode impedance is a useful tool to investigate electrode array integrity as well as to raise suspicion of possible electrode migration. Patients implanted with a straight electrode from CochlearTM array might benefit from lead wire fixation.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Cóclea/cirugía , Impedancia Eléctrica , Electrodos Implantados/efectos adversos , Humanos , Estudios Retrospectivos
13.
Audiol Neurootol ; 26(3): 135-139, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-32877899

RESUMEN

INTRODUCTION: Semicircular canal dehiscence (SCD) is defined as a defect of the bone overlying the semicircular canal. It has a relatively high prevalence of 3% in the general population, which makes it likely that a certain number of patients receiving a cochlear implant (CI) would have it. However, little is known about the influence of SCD on the CI outcome. Therefore, the aim of this study was to determine the influence of SCD on CI outcome with regard to short- and long-term word perception and hearing preservation. METHODS: This study was a retrospective analysis of postoperative word perception ability in the electric-only condition after 6, 12, and ≥18 months and of hearing preservation 4 weeks after surgery in CI recipients with and without SCD. All patients received a preoperative 1.5- or 3-tesla magnetic resonance imaging. RESULTS: Fifty-five patients were included. Forty-eight patients (87%) had no SCD, and 7 patients (13%) had SCD. Mean postoperative word perception scores were 66% in the non-SCD group versus 50% in the SCD group (p = 0.17) after 6 months, 74 versus 64% (p = 0.28) after 12 months, and 77 versus 73% (p = 0.62) after 18 or more months. The mean postoperative hearing loss in patients with functional residual hearing before surgery (n = 34) was 22 dB in the non-SCD group versus 31 dB in the SCD group (p = 0.15). CONCLUSIONS: CI outcome is comparable between recipients without and with SCD. Specifically, hearing preservation rate and word perception ability in the electric-only condition seem not affected by SCD. The rate of progress of word perception ability in the first 12 months after cochlear implantation is not influenced by SCD.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Pérdida Auditiva/cirugía , Dehiscencia del Canal Semicircular/complicaciones , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Pérdida Auditiva/complicaciones , Pérdida Auditiva/diagnóstico por imagen , Pérdida Auditiva/fisiopatología , Pruebas Auditivas , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Estudios Retrospectivos , Dehiscencia del Canal Semicircular/diagnóstico por imagen , Dehiscencia del Canal Semicircular/fisiopatología , Percepción del Habla/fisiología , Resultado del Tratamiento , Adulto Joven
14.
Ear Hear ; 42(2): 414-424, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-32826509

RESUMEN

OBJECTIVES: (1) To correlate simultaneously recorded intra- and extracochlear electrocochleography (ECochG) signals during electrode insertion into the cochlea, (2) to track changes in the ECochG signal during insertion and removal of an electrode, and (3) to correlate the findings with the preoperative residual hearing. We hypothesized that intracochlear ECochG recordings show signal changes not reflected in simultaneous extracochlear ECochG recordings. DESIGN: During cochlear implantation in human cochlear implant recipients, a short, slim, custom-made electrode was inserted and removed in a stepwise manner. At each step, ECochG recordings were simultaneously recorded by an extracochlear electrode near the round window and via the inserted electrode. The acoustic stimulus was a 500 Hz tone burst at 110 to 130 dB SPL. RESULTS: The mean amplitude difference between intra- and extracochlear ongoing ECochG responses was 14 dB (range 9 to 24 dB; n = 10) at the beginning of insertion. Intracochlear ECochG responses were larger in all cases. Extracochlear ECochG responses remained stable while intracochlear recordings showed large variations regarding amplitude and phase during the electrode array insertion. Intracochlear signal changes during insertion were reversible with retraction of the electrode. There were only weak to moderate (rs = 0.006 to 0.4), nonsignificant correlations of residual preoperative hearing with maximum amplitudes and amplitude changes during electrode insertion and removal in intracochlear recordings. CONCLUSIONS: Signals in intracochlear ECochG recordings are reliably larger than ECochG signals recorded simultaneously from an extracochlear location. Intracochlear ECochG recordings show reversible amplitude and phase changes during insertion, not reflected in simultaneous extracochlear ECochG recordings. Such changes are most likely due to the movement of the recording electrode in relation to the signal generators. Residual high-frequency hearing is associated with larger ECochG signal amplitudes. Modeling of expected intracochlear ECochG changes during electrode insertions may allow detection of cochlear trauma in the future.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Audiometría de Respuesta Evocada , Cóclea/cirugía , Electrodos , Humanos , Ventana Redonda
15.
Eur Arch Otorhinolaryngol ; 278(2): 561-565, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32583181

RESUMEN

PURPOSE: Aural fullness is a common symptom of middle ear diseases, most importantly Eustachian tube dysfunction (ETD). Yet, aural fullness may also be caused by inner ear disorders, such as hydropic ear diseases. Here, we report our experience with endolymphatic hydrops (EH) mimicking ETD. Furthermore, we review the literature related to (i) EH as a differential diagnosis of symptoms suggesting ETD and (ii) the pathophysiology and treatment of aural fullness due to inner ear disorders. METHODS: We retrospectively included adult patients with aural fullness as chief complaint and radiographically diagnosed EH. Hearing and Eustachian tube function were assessed using audiometry, tympanometry, and tubomanometry. Primarily suspected ETD was treated by balloon dilatation of the Eustachian tube (BDET). The endolymphatic space of the inner ear was imaged using gadolinium-enhanced MRI (Gd-MRI) including a 3D-real inversion-recovery sequence after intravenous gadolinium administration. RESULTS: We report three affected ears of two patients (two females, age 42 and age 51) with aural fullness as chief complaint. Audiometry of main speech frequencies was normal in all affected ears. In one ear, there was a type A tympanogram and in two ears, there was a type B tympanogram. In both patients, medical treatment for ETD and BDET were unsuccessful. Gd-MRI of the inner ears revealed cochlear EH in 3/3 ears affected by aural fullness, but not in the unaffected ear. CONCLUSION: EH may underlay cases with aural fullness and could in these cases explain unsuccessful treatment for ETD. As ETD is often treated by invasive procedures, distinguishing ETD from EH as the underlying cause of aural fullness is important. Our findings raise the question whether Gd-MRI to rule out EH is indicated in patients with unexplained aural fullness, in particular after unsuccessful interventional treatment for ETD.


Asunto(s)
Enfermedades del Oído , Hidropesía Endolinfática , Trompa Auditiva , Adulto , Enfermedades del Oído/diagnóstico por imagen , Hidropesía Endolinfática/diagnóstico por imagen , Trompa Auditiva/diagnóstico por imagen , Femenino , Gadolinio , Humanos , Imagen por Resonancia Magnética , Estudios Retrospectivos
16.
Otol Neurotol ; 41(3): 318-326, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31834213

RESUMEN

OBJECTIVE: To determine the correlation between intraoperative changes of electrocochleography (ECochG) responses and traumatic cochlear implant insertions as well as postoperative hearing loss. METHODS: ECochG, radiological, and audiological data were collected prospectively in a cochlear implant recipient with otosclerosis and assumed cochlear trauma during electrode insertion. A systematic review was conducted within PubMed-NCBI, EMBASE, and the Cochrane Library using the terms "Cochlear implant" and "Electrocochleography." Original studies that evaluated intraoperative ECochG responses and postoperative hearing loss were selected and analyzed. RESULTS: The case report revealed a drop of intra- and extracochlear ECochG signals during electrode insertion. The postoperative computed tomography scan suggested a scalar dislocation. There was no measurable hearing 4 weeks after surgery. Within the database search, nine articles met the inclusion criteria. All were case series reports (range from 2 to 36 subjects) with a total of 173 subjects. Due to the heterogeneous data, a meta-analysis was unfeasible. CONCLUSIONS: In concordance with some findings in the literature, the presented case report suggests that a drop of intra- and extracochlear ECochG signals during the insertion of the electrode array is associated with cochlear trauma and postoperative hearing loss in some cases. However, the literature is inconclusive regarding the correlation between intraoperative changes of the ECochG signals and postoperative hearing preservation. More studies investigating the correlation are needed to provide sufficient data.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Audiometría de Respuesta Evocada , Cóclea/cirugía , Audición , Humanos
17.
Swiss Med Wkly ; 149: w20171, 2019 Dec 16.
Artículo en Inglés | MEDLINE | ID: mdl-31880806

RESUMEN

AIM OF THE STUDY: The aim of this multicentre, prospective, open, nonrandomised clinical trial was to demonstrate the clinical efficiency and outcomes of cochlear implants (CIs) in adult patients with post-lingual single-sided deafness (SSD). METHODS: A group of five left and five right SSD participants were investigated with various clinical tests and questionnaires before and 12 months after CI activation. Changes in hearing thresholds, speech understanding in noise, sound localisation, tinnitus (Tinnitus Handicap Inventory; THI), subjective hearing ability (Speech, Spatial and Qualities of Hearing Scale; SSQ), and quality of life (WHOQOL-BREF) were assessed. In addition, the pre- and postoperative results of the SSD patients were compared with an age- and gender-matched normal hearing control group. RESULTS: Surgery was uncomplicated in all patients. Two years after implantation, 9 of the 10 patients used their CI regularly for an average of more than 11 hours a day. A significant improvement in speech understanding in noise measured in the sound field using the Oldenburg sentence test could be demonstrated in the two situations in which patients with SSD experience the greatest difficulty: speech from the front and noise at the healthy ear, and speech to the implanted ear and noise from the front. The sound localisation test showed significant improvement of the mean localisation error and the root mean square error after CI activation. Furthermore, a significant reduction of the THI was measured, and the SSQ showed a significant improvement in the subscale speech comprehension and in the subscale spatial hearing. Also, quality of life measured with the WHOQOL-BREF showed a general improvement, which was significant in the global subscale. For this questionnaire, there was no significant difference between the normal-hearing control group and the patients after 12 months of CI use. CONCLUSION: This study confirmed the clinical benefit of cochlear implantation in patients with SSD. The significant improvement of speech understanding in noise, sound localisation, tinnitus perception, subjective hearing ability, and in particular the improved quality of life support the recommendation that patients with recently acquired SSD should be offered a CI. (Clinical trial registration number on clinicaltrial.gov: NCT01749592).


Asunto(s)
Implantes Cocleares/psicología , Pérdida Auditiva Bilateral/psicología , Pérdida Auditiva Bilateral/cirugía , Calidad de Vida/psicología , Adulto , Implantación Coclear/métodos , Femenino , Audición , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Habla , Encuestas y Cuestionarios
18.
Otol Neurotol ; 40(7): 892-899, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31157721

RESUMEN

OBJECTIVE: To analyze the impact of age at implantation on the cost-effectiveness of cochlear implantation (CI). STUDY DESIGN: Cost-utility analysis in an adapted Markov model. SETTING: Adults with profound postlingual hearing loss in a "high income" country. INTERVENTION: Unilateral and sequential CI were compared with hearing aids (HA). MAIN OUTCOME MEASURE: Incremental cost-effectiveness ratio (ICER), calculated as costs per quality adjusted life year (QALY) gained (in CHF/QALY), for individual age and sex combinations in relation to two different willingness to pay thresholds. 1 CHF (Swiss franc) is equivalent to 1.01 USD. RESULTS: When a threshold of 50,000 CHF per QALY is applied, unilateral CI in comparison to HA is cost-effective up to an age of 91 for women and 89 for men. Sequential CI in comparison to HA is cost-effective up to an age of 87 for women and 85 for men. If a more contemporary threshold of 100,000 CHF per QALY is applied, sequential CI in comparison to unilateral CI is cost-effective up to an age of 80 for women and 78 for men. CONCLUSIONS: Performing both sequential and unilateral CI is cost-effective up to very advanced ages when compared with hearing aids.


Asunto(s)
Implantación Coclear/economía , Implantes Cocleares/economía , Adulto , Factores de Edad , Algoritmos , Análisis Costo-Beneficio , Femenino , Humanos , Masculino , Persona de Mediana Edad , Años de Vida Ajustados por Calidad de Vida
19.
Otol Neurotol ; 40(4): e424-e429, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30870377

RESUMEN

OBJECTIVE: To assess by electrocochleography (ECoG) at which times during cochlear implantation changes of cochlear function occur. METHODS: Tone bursts with a frequency of 500 or 750 Hz were used as acoustic stimuli. The recording electrode was placed on the promontory and left in an unchanged position for all ECoG recordings. RESULTS: Eight subjects were included. After opening the cochlea, an increase of the amplitude of the ECoG signal was detectable in four subjects (mean change 3.9 dB, range from 0.2 to 10.8 dB). No decreases were detectable after opening the cochlea or during the first half of the insertion of the CI electrode array (mean change 0.5 dB, range from -2.2 to 1.6 dB). During the second half of the insertion, the amplitude of the ECoG signal decreased in four subjects (mean change -2.5 dB, range from -0.04 to -4.8 dB). If a decrease occurred during the second half of the insertion, then the decrease continued in the earliest phase after insertion of the CI electrode array (mean change -2.1 dB, range from -0.5 to -5.8 dB). CONCLUSION: Pressure changes inside the cochlea can lead to an increase of ECoG signals after opening the cochlea. If detectable, then a decrease of ECoG signals occurs during the second half of the insertion of the CI electrode array and continues in the earliest phase after completed insertion. These findings suggest that cochlear trauma occurs toward the end of the insertion and that trauma-dependent postoperative mechanisms contribute to postoperative hearing loss.


Asunto(s)
Audiometría de Respuesta Evocada/métodos , Cóclea/fisiopatología , Cóclea/cirugía , Implantación Coclear/métodos , Monitorización Neurofisiológica Intraoperatoria/métodos , Adulto , Anciano , Berlin , Implantes Cocleares , Femenino , Pérdida Auditiva/cirugía , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
20.
Int J Audiol ; 58(6): 333-338, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30688126

RESUMEN

OBJECTIVE: To evaluate the quality of perceived sound after stapedotomy over a 1-year follow-up period focussing on incidence of dysacusis, particularly distorted sound perception (DSP). DSP was assessed by (i) determination of the frequencies and hearing level that such perceptions are elicited by pure tones (pure-tone-evoked distorted sound perception, PTE-DSP), a novel psychoacoustic measurement introduced in this paper, and (ii) assessment of patient-reported occurrence of DSP using the Amsterdam Post Operative Sound Evaluation (APOSE) questionnaire (APOSE-DSP). DESIGN: Prospective study. STUDY SAMPLE: Patients (n = 23) with otosclerosis undergoing stapedotomy. RESULTS: An air-bone gap of <20 dB was achieved in 100% of the patients. Three weeks postoperatively, 48% of the patients reported measured PTE-DSP and 39% of the patients experienced APOSE-DSP. The PTE-DSP significantly decreased during the 1-year follow-up period (p = 0.03). Postoperatively, APOSE-DSP was associated with a smaller benefit (improvement in air conduction; p = 0.03), yet, a lower bone conduction pure-tone average was associated with PTE-DSP (p = 0.006). CONCLUSIONS: DSP after stapedotomy is associated with a smaller benefit 3 months after stapedotomy. DSP commonly occur after stapedotomy, but decrease over time. This is important information to be included in patient counselling before stapedotomy.


Asunto(s)
Audición , Cirugía del Estribo , Adulto , Anciano , Audiometría de Tonos Puros , Percepción Auditiva , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...