Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Blood Press Monit ; 28(6): 295-302, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-37910023

RESUMEN

OBJECTIVE: The objective of this study is to identify 24-h blood pressure (BP) characteristics after acute stroke in Indian hospitalized patients. METHODS: In total, 769 patients [284 women (36.9%)] admitted at a hospital in South India were analyzed. Of these, 364 patients (47.3%) had recently experienced stroke. All patients underwent ambulatory blood pressure measurement (ABPM) so that ABPM patterns and ABPM risk parameters of stroke and non-stroke patients could be compared. Additionally, to investigate the relationship between ABPM parameters and stroke, a stepwise logistic regression analysis was employed. RESULTS: Stroke patients had significantly higher BP than non-stroke patients (24-h ABP: 145.0 ±â€…22.1 vs. 133.7 ±â€…20.5 mmHg, P < 0.001), with similar dipping status. ABPM parameters mostly associated with stroke (all P < 0.001) were: nighttime [odds ratios (OR): 1.587, 95% confidence interval (95% CI): 1.341-1.885], 24-h (1.584, 1.34-1.881), minimum nighttime (1.582, 1.339-1.879), daytime (1.540, 1.304-1.827), and morning SBP (1.517, 1.287-1.797). Non-dipping status was relatively more common in stroke patients (79% vs. 71%, P < 0.05) but dipping percentage did not show a significant linear relationship with stroke. CONCLUSION: Several ABPM characteristics were strongly associated with stroke in Indian hospitalized patients. Specifically, minimum nighttime and average morning SBP may be considered as important and practical parameters for its relationship with stroke.


Asunto(s)
Monitoreo Ambulatorio de la Presión Arterial , Accidente Cerebrovascular , Humanos , Femenino , Presión Sanguínea , Pueblo Asiatico , Determinación de la Presión Sanguínea
2.
J Hum Hypertens ; 37(2): 130-133, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-35760957

RESUMEN

A group of experts from reputable blood pressure measuring device (BPMD) manufacturers was invited to provide industry perspectives on the global use of validated BPMD. The authors support the recommendations of (1) using the consolidated universal ISO 81060-2:2018 in all future validation studies to ensure consistent and trustworthy quality standards; (2) validation studies to be led by investigators independent from the manufacturer; (3) validation study results to be published in peer-reviewed journals with an independent investigator as the corresponding author; and (4) validated BPMDs to be listed on validated device registries such as STRIDE BP, Validated Device Listing (VDL), and others that are backed by acknowledged scientific associations. The authors call for public awareness of the existence of legally marketed consumer BPMDs that lack sufficient evidence of clinical accuracy. Other important issues and future considerations were discussed, including the need: for awareness building and promoting the use of validated BPMDs among practitioners; to identify a non-mercury sphygmomanometer based reference device to validate BPMDs; to include all cuffs available for use with each BPMD in the validation study; for the promotion of validation studies for special patient populations; for validated wrist BPMDs as an alternative for some patients; for technical innovations to help reduce limitations related to the human aspect of validation studies; for validation of cuffless BPMDs; for validation through equivalency to validated base models; and to use validated BPMD in remote patient monitoring programs. A future collaborative to find solutions to support the use of validated BPMD is envisaged.


Asunto(s)
Determinación de la Presión Sanguínea , Hipertensión , Humanos , Presión Sanguínea , Determinación de la Presión Sanguínea/métodos , Hipertensión/diagnóstico , Esfigmomanometros
3.
Artículo en Inglés | MEDLINE | ID: mdl-36468352

RESUMEN

Hypertension guidelines recommend measuring blood pressure (BP) in both arms at least once. However, this is seldom done due to uncertainties regarding measurement procedure and the implications of finding a clinically important inter-arm BP difference (IAD). This study aimed to provide insight into the prevalence of clinically important IADs in a large Indian primary care cohort. A number of 134678 (37% female) unselected Indian primary care participants, mean age 45.2 (SD 11.9) years, had BP measured in both arms using a standardized, triplicate, automated simultaneous measurement method (Microlife WatchBP Office Afib). On average, there were clinically minor differences in right and left arm BP values: systolic BP 134.4 vs. 134.2 mmHg (p<0.01) and diastolic BP 82.7 vs. 82.6 mmHg (p<0.01), respectively. Prevalence of significant mean systolic IAD between 10 and 15 mmHg was 7813 (5.8%). Systolic IAD ≥ 15 mmHg 2980 (2.2%) and diastolic IAD ≥ 10 mmHg 7151 (5.3%). In total, there were 7595 (5.6%) and 8548 (6.3%) participants with BP above the 140/90 mmHg threshold in only the left or right arm, respectively. Prevalence of participants with elevated BP on one arm only was highest in patients with a systolic IAD ≥ 15 mmHg; 19.1% and 13.7%, for left and right arm, respectively. This study shows that a substantial prevalence of IAD exist in Indian primary care patients. BP is above the diagnostic threshold for hypertension in one arm only for 6% of participants. These findings emphasise the importance of undertaking bilateral BP measurement in routine clinical practice. This article is protected by copyright. All rights reserved.

4.
J Clin Hypertens (Greenwich) ; 24(8): 993-1002, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35811439

RESUMEN

Hypertension guidelines recommend measuring blood pressure (BP) in both arms at least once. However, this is seldom done due to uncertainties regarding measurement procedure and the implications of finding a clinically important inter-arm BP difference (IAD). This study aimed to provide insight into the prevalence of clinically important IADs in a large Indian primary care cohort. A number of 134 678 (37% female) unselected Indian primary care participants, mean age 45.2 (SD 11.9) years, had BP measured in both arms using a standardized, triplicate, automated simultaneous measurement method (Microlife WatchBP Office Afib). On average, there were clinically minor differences in right and left arm BP values: systolic BP 134.4 vs 134.2 mmHg (p < .01) and diastolic BP 82.7 vs 82.6 mmHg (p < .01), respectively. Prevalence of significant mean systolic IAD between 10 and 15 mmHg was 7,813 (5.8%). Systolic IAD ≥ 15 mmHg 2,980 (2.2%) and diastolic IAD ≥ 10 mmHg 7,151 (5.3%). In total, there were 7,595 (5.6%) and 8,548 (6.3%) participants with BP above the 140/90 mmHg threshold in only the left or right arm, respectively. Prevalence of participants with elevated BP on one arm only was highest in patients with a systolic IAD ≥ 15 mmHg; 19.1% and 13.7%, for left and right arm, respectively. This study shows that a substantial prevalence of IAD exists in Indian primary care patients. BP is above the diagnostic threshold for hypertension in one arm only for 6% of participants. These findings emphasize the importance of undertaking bilateral BP measurement in routine clinical practice.


Asunto(s)
Hipertensión , Hormona Adrenocorticotrópica/deficiencia , Presión Sanguínea/fisiología , Determinación de la Presión Sanguínea/métodos , Enfermedades del Sistema Endocrino , Femenino , Enfermedades Genéticas Congénitas , Humanos , Hipertensión/diagnóstico , Hipertensión/epidemiología , Hipoglucemia , Masculino , Persona de Mediana Edad , Prevalencia , Atención Primaria de Salud
6.
PLoS One ; 17(3): e0263619, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35358208

RESUMEN

BACKGROUND: Type 2 diabetes mellitus (T2DM) worldwide continues to increase, in particular in India. Early T2DM diagnosis followed by appropriate management will result in more cardiovascular event free life years. However, knowledge of the cardiovascular profile of newly diagnosed T2DM patients is still limited. The aim of this study was to understand the extent of cardiovascular disease (CVD) risk of newly diagnosed T2DM patients in India. METHODS: A cross sectional observational study was conducted to evaluate clinical laboratory and socio-demographic parameters of 5,080 newly diagnosed T2DM patients (48.3 ± 12.8 years of age; 36.7% female). In addition, we determined their cardiovascular risk according to the guidelines of the Lipid Association of India (LAI) and the criteria of the QRISK3 score. RESULTS: Of the newly T2DM diagnosed patients in India 2,007(39.5%) were classified as "High risk" and 3,073 (60.5%) were classified as "Very high risk" based on LAI criteria. On average, patients had 1.7 ± 0.9 major atherosclerotic cardiovascular disease (ASCVD) risk factors. Low HDL-C value was the most frequent major risk (2,823; 55.6%) followed by high age (2,502; 49.3%), hypertension (2,141; 42.1%), smoking/tobacco use (1,078; 21.2%) and chronic kidney disease stage 3b or higher (568; 11.2%). In addition, 4,192 (82.5%) patients appeared to have at least one cholesterol abnormality and, if the latest LAI recommendations are applied, 96.5% (4,902) presented with lipid values above recommended targets. Based on the QRISK3 calculation Indian diabetes patients had an average CVD risk of 15.3 ± 12.3%, (12.2 ± 10.1 vs. 17.1 ± 13.5 [p<0.001] for females and males, respectively). CONCLUSIONS: Newly diagnosed Indian T2DM patients are at high ASCVD risk. Our data therefore support the notion that further extension of nationwide ASCVD risk identification programs and prevention strategies to reduce the occurrence of cardiovascular diseases are warranted.


Asunto(s)
Aterosclerosis , Enfermedades Cardiovasculares , Diabetes Mellitus Tipo 2 , Adulto , Enfermedades Cardiovasculares/diagnóstico , Enfermedades Cardiovasculares/epidemiología , Estudios Transversales , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/epidemiología , Femenino , Factores de Riesgo de Enfermedad Cardiaca , Humanos , India/epidemiología , Lípidos/uso terapéutico , Masculino , Factores de Riesgo
7.
J Clin Hypertens (Greenwich) ; 24(1): 74-82, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34904364

RESUMEN

Cardiovascular diseases have become the major cause of death in India, but overall awareness is still low. Therefore, the initiative was undertaken to set up health care screening booths at eight airports and one hospital throughout India to increase awareness and to determine cardiovascular risk factors. Participants were screened for hypertension (systolic blood pressure (BP) ≥140 mmHg or diastolic BP≥90 mmHg), diabetes [fasting blood glucose (FBG) level ≥126  or ≥200 mg/dL for random blood glucose (RBG)], and body mass index (BMI). Among 100 107 participants screened (46 ± 13 years; 17% women), prevalence of diabetes was 12 571 (15%), hypertension: 30 345 (33%) and overweight: 61 219 (65%). Diabetes was treated more often than hypertension (44% vs 11%). Hypertension and diabetes prevalence values were relatively high in young obese adults; BMI correlated significantly (p < .001) stronger to both systolic BP and RBG for subjects younger than 40 years than for those who were older (r = 0.27 vs r = 0.06 and r = 0.15 vs r = 0.03, respectively). Among obese women aged 60 years and older the hypertension prevalence was higher than 40%, in obese men this prevalence value was already seen from the group of 30 to 40 years old. For participants older than 50 years with hypertension, diabetes prevalence was 20%. These results show that screening initiatives like these are highly needed to increase the overall awareness of diabetes and particularly of hypertension. Systematic screening programs also help to identify specific patient populations and cope with undertreatment of those at the highest cardiovascular risk. The fact that women were underrepresented in the present screening campaign suggests actions are needed to encourage them to participate in health care programs.


Asunto(s)
Enfermedades Cardiovasculares , Hipertensión , Adulto , Anciano , Aeropuertos , Presión Sanguínea , Enfermedades Cardiovasculares/prevención & control , Femenino , Factores de Riesgo de Enfermedad Cardiaca , Humanos , Hipertensión/diagnóstico , India/epidemiología , Masculino , Persona de Mediana Edad , Prevalencia , Factores de Riesgo
9.
J Clin Hypertens (Greenwich) ; 22(7): 1154-1162, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32558208

RESUMEN

Women are underrepresented in groups of patients seeking hypertension care in India. The present paper reports trends in office and ambulatory blood pressure measurement (OBPM, ABPM) and 24-h heart rate (HR) with sex in 14,977 subjects untreated for hypertension (aged 47.3 ± 13.9 years, males 69.4%) visiting primary care physicians. Results showed that, for systolic blood pressure (SBP), females had lower daytime ABPM (131 ± 16 vs. 133 ± 14 mm Hg, P < .001) but higher nighttime ABPM (122 ± 18 vs. 121 ± 16 mm Hg, P < .001) than males. Females had higher HR than men at daytime (80 ± 11 vs 79 ± 11.5 bpm) and nighttime (71 ± 11 vs 69 ± 11), respectively (all P < .001). Dipping percentages for SBP (7.4 ± 7.3 vs 9.3 ± 7.4%), DBP (10.1 ± 8.6 vs. 12.3 ± 8.9%), and HR (10.7 ± 7.9 vs. 12.8 ± 9.2%) were lower (P < .001) for females than for males, respectively. Females more often had isolated nighttime hypertension as compared to males (14.9%, n = 684% vs 10.6%, n = 1105; P < .001). BP patterns and HR showed clear differences in sex, particularly at nighttime. As females were more often affected by non-dipping and elevated nighttime SBP and HR than males, they should receive ABPM, at least, as frequently as men to document higher risk necessitating treatment.


Asunto(s)
Monitoreo Ambulatorio de la Presión Arterial , Adulto , Presión Sanguínea , Ritmo Circadiano , Femenino , Frecuencia Cardíaca , Humanos , Hipertensión/diagnóstico , Hipertensión/epidemiología , India/epidemiología , Masculino , Persona de Mediana Edad
10.
J Hypertens ; 38(7): 1262-1270, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32195821

RESUMEN

OBJECTIVE: India Heart Study (IHS) is aimed at investigating the agreement between office blood pressure measurement (OBPM) and self (S)BPM in a hypertension-naive population. METHODS: A total of 18 918 individuals (aged 42.6 ±â€Š11.7 years, 62.7% men), visiting 1237 primary care physicians across India, underwent OBPM. They performed SBPM for a period of 1 week using a validated oscillometric BP monitor that was preprogrammed to adhere to a guideline-based SBPM-schedule and blinded to the results. Thereafter, individuals underwent a second OBPM. Available laboratory results were obtained. Thresholds for elevated OBPM and SBPM were 140/90 and 135/85 mmHg, respectively. RESULTS: On the basis of first-visit OBPM and SBPM, there were 5787 (30.6%) individuals with normotension; 5208 (27.5%) with hypertension; 4485 (23.7%) with white-coat hypertension (WCH) and 3438 (18.2%) with masked hypertension. Thus, a diagnosis contradiction between SBPM and first-visit OBPM was seen in 9870 (41.9%) individuals. On the basis of second-visit OBPM, the normotension, hypertension, WCH and masked hypertension prevalence values were 7875 (41.6%); 4857 (25.7%); 2397 (12.7%) and 3789 (20.0%). There was poor agreement (kappa value 0.37) between OBPM of visit 1 and 2 with a diagnosis difference in 6027 (31.8%) individuals. The majority of masked hypertension and WCH individuals had BP values close to thresholds. CONCLUSION: There was a poor agreement between OBPM of visit1 and visit 2. Likewise, the agreement between OBPM at both visits and SBPM was poor. SBPM being considered to have a better correlation with patient prognosis should be the preferred method for diagnosing hypertension.


Asunto(s)
Determinación de la Presión Sanguínea/métodos , Presión Sanguínea , Hipertensión/diagnóstico , Autocuidado , Adulto , Femenino , Humanos , Hipertensión/fisiopatología , India/epidemiología , Masculino , Hipertensión Enmascarada/diagnóstico , Persona de Mediana Edad , Visita a Consultorio Médico , Oscilometría , Prevalencia , Atención Primaria de Salud , Reproducibilidad de los Resultados , Hipertensión de la Bata Blanca/diagnóstico
11.
J Hum Hypertens ; 34(6): 457-467, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-31484988

RESUMEN

The present paper reports differences between office blood pressure (BP) measurement (OBPM) and ambulatory blood pressure measurement (ABPM) in a large multi-centre Indian all comers' population visiting primary care physicians. ABPM and OBPM data from 27,472 subjects (aged 51 ± 14 years, males 68.2%, treated 45.5%) were analysed and compared. Patients were classified based on the following hypertension thresholds: systolic BP (SBP) ≥ 140 and/or diastolic BP (DBP) ≥90 mmHg for OBPM, and SBP ≥ 130 and/or DBP ≥ 80 mmHg for 24-h ABPM, and SBP ≥ 120 and/or DBP ≥ 70 mmHg for night-time ABPM and SBP ≥ 135 and/or DBP ≥ 85 mmHg for daytime ABPM, all together. White coat hypertension (WCH) was seen in 12.0% (n = 3304), masked hypertension (MH) in 19.3% (n = 5293) and 55.5% (n = 15,246) had sustained hypertension. Isolated night-time hypertension (INH) was diagnosed in 11.9% (n = 3256). Untreated subjects had MH relatively more often than treated subjects (23.0% vs. 14.8%, p < 0.0001; respectively). Females had higher relative risk (RR) of having WCH than males (RR 1.16 [CI 95, 1.07-1.25], p < 0.0001). Whereas, males had higher RR of MH than females (RR 1.09 [CI 95, 1.02-1.17] p < 0.01). INH subjects had lower average systolic and diastolic dipping percentages (0.7 ± 6.6/ 2.2 ± 7.9 vs. 9.0 ± 7.3/11.9 ± 8.5, p < 0.001) than those without INH. In conclusion, for diagnosis of hypertension there was a contradiction between OBPM and ABPM in approximately one-third of all patients, and a substantial number of patients had INH. Using ABPM in routine hypertension management can lead to a reduction in burden and associated costs for Indian healthcare.


Asunto(s)
Monitoreo Ambulatorio de la Presión Arterial , Hipertensión , Presión Sanguínea , Determinación de la Presión Sanguínea , Femenino , Humanos , Hipertensión/diagnóstico , Hipertensión/tratamiento farmacológico , Hipertensión/epidemiología , India/epidemiología , Masculino
12.
J Clin Hypertens (Greenwich) ; 21(12): 1784-1794, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31769171

RESUMEN

The present paper reports trends in office blood pressure (BP) measurement (OBPM) and ambulatory blood pressure measurement (ABPM) with age in a large multi-center Indian all comers' population visiting primary care physicians. ABPM and OBPM data from 27 472 subjects (aged 51 ± 14 years, males 68.2%, treated 45.5%) were analyzed and compared. Individual differences between OBPM and ABPM patterns were compared for patients according to 10-year age categories. Results showed that systolic (S) BP values started to increase with age from the age of 40, BP variability (SD) increased from the age of 30 years. Diastolic (D) BP values started to decrease from the age of 50 years. Mean OBPM values were higher than daytime ABPM values (all P < .001) in all age-groups. The prevalence of white coat hypertension (WCH) and masked hypertension (MH) was based on OBPM and daytime, 24-hour, and nighttime average BPs together. WCH decreased with age from 15.1% and 12.4% in treated and untreated subjects at the youngest age to 7.2% and 6.9% in the oldest age, respectively. MH prevalence was higher for untreated than for treated subjects but remained similar for all age-groups (range of 18.6%-21.3%). The prevalence of reverse dippers increased with age from the youngest to oldest group with 7.3%-34.2% (P < .001 for trend). Dippers prevalence decreased from 42.5% to 17.9% from the youngest to oldest age-groups, respectively (P < .001 for trend). These findings confirm that BP patterns show clear differences in trends with age, particularly regarding nighttime BP.


Asunto(s)
Determinación de la Presión Sanguínea/instrumentación , Monitoreo Ambulatorio de la Presión Arterial/métodos , Presión Sanguínea/fisiología , Hipertensión/fisiopatología , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Antihipertensivos/uso terapéutico , Variación Biológica Poblacional/fisiología , Estudios de Casos y Controles , Ritmo Circadiano , Diástole/fisiología , Femenino , Humanos , Hipertensión/diagnóstico , Hipertensión/tratamiento farmacológico , India/epidemiología , Masculino , Hipertensión Enmascarada/diagnóstico , Hipertensión Enmascarada/tratamiento farmacológico , Hipertensión Enmascarada/epidemiología , Persona de Mediana Edad , Prevalencia , Atención Primaria de Salud/estadística & datos numéricos , Sístole/fisiología , Hipertensión de la Bata Blanca/diagnóstico , Hipertensión de la Bata Blanca/tratamiento farmacológico , Hipertensión de la Bata Blanca/epidemiología
13.
Blood Press ; 28(1): 15-22, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30460865

RESUMEN

PURPOSE: Hypertension guidelines recommend measuring blood pressure (BP) on both arms, since an abnormal inter-arm difference (IAD) in BP is associated with an increased risk of vascular abnormalities and cardiovascular (CV) disease. We tested whether an automatic oscillometric BP monitor allowing simultaneous both arm BP measurement might be effective for screening of subjects with potential vascular disease. MATERIALS AND METHODS: 220 consecutive subjects from an unselected sample of individuals of a small Italian community were screened using an automated upper-arm electronic BP monitor (Microlife WatchBP Office). Seated BP was measured in triplicate at 1 min interval. Demographic and clinical data were collected prior to any BP measurement. An average IAD difference >20 mmHg for systolic (S) and/or >10 mmHg for diastolic (D) BP was considered abnormal. RESULTS: In 9 subjects (4.1%) an abnormal IAD was found, with lower BPs measured in the non-dominant arm (147 ± 28/78 ± 9 vs. 154 ± 15/92 ± 11 mmHg dominant, p<.01). Subjects with a significant IAD were significantly older (71 ± 8 vs. 57 ± 15 years, p=.005), had a greater body mass index (BMI: 32 ± 7 vs. 25 ± 4 kg/m2, p=.0001), higher BP levels (154 ± 15/92 ± 11 vs. 133 ± 18/80 ± 10 mmHg, p=.001) and were more likely to report obesity (56 vs. 13%, p=.001), a history of hypertension (67 vs. 35%, p=.044) or cardiovascular disease (33 vs. 10%, p=.034) than subjects with normal IAD. In a multivariate analysis, a higher BMI [odds ratio (95% confidence interval): 1.29 (1.11, 1.51)] and SBP [1.06 (1.01, 1.10)] were significantly associated with a larger risk of an abnormal IAD (p=.001 and p=.012, respectively). CONCLUSIONS: An abnormal IAD in BP is associated with a larger prevalence of CV risk factors and CV disease. Our study confirms that simultaneous both arm BP measurement must always be accomplished in subjects at risk for or with established CV disease.


Asunto(s)
Determinación de la Presión Sanguínea/métodos , Enfermedades Cardiovasculares/diagnóstico , Tamizaje Masivo/métodos , Adulto , Factores de Edad , Anciano , Índice de Masa Corporal , Humanos , Hipertensión , Italia , Persona de Mediana Edad , Obesidad , Características de la Residencia , Factores de Riesgo
14.
PLoS Med ; 14(9): e1002389, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28926573

RESUMEN

BACKGROUND: Self-monitoring of blood pressure (BP) appears to reduce BP in hypertension but important questions remain regarding effective implementation and which groups may benefit most. This individual patient data (IPD) meta-analysis was performed to better understand the effectiveness of BP self-monitoring to lower BP and control hypertension. METHODS AND FINDINGS: Medline, Embase, and the Cochrane Library were searched for randomised trials comparing self-monitoring to no self-monitoring in hypertensive patients (June 2016). Two reviewers independently assessed articles for eligibility and the authors of eligible trials were approached requesting IPD. Of 2,846 articles in the initial search, 36 were eligible. IPD were provided from 25 trials, including 1 unpublished study. Data for the primary outcomes-change in mean clinic or ambulatory BP and proportion controlled below target at 12 months-were available from 15/19 possible studies (7,138/8,292 [86%] of randomised participants). Overall, self-monitoring was associated with reduced clinic systolic blood pressure (sBP) compared to usual care at 12 months (-3.2 mmHg, [95% CI -4.9, -1.6 mmHg]). However, this effect was strongly influenced by the intensity of co-intervention ranging from no effect with self-monitoring alone (-1.0 mmHg [-3.3, 1.2]), to a 6.1 mmHg (-9.0, -3.2) reduction when monitoring was combined with intensive support. Self-monitoring was most effective in those with fewer antihypertensive medications and higher baseline sBP up to 170 mmHg. No differences in efficacy were seen by sex or by most comorbidities. Ambulatory BP data at 12 months were available from 4 trials (1,478 patients), which assessed self-monitoring with little or no co-intervention. There was no association between self-monitoring and either lower clinic or ambulatory sBP in this group (clinic -0.2 mmHg [-2.2, 1.8]; ambulatory 1.1 mmHg [-0.3, 2.5]). Results for diastolic blood pressure (dBP) were similar. The main limitation of this work was that significant heterogeneity remained. This was at least in part due to different inclusion criteria, self-monitoring regimes, and target BPs in included studies. CONCLUSIONS: Self-monitoring alone is not associated with lower BP or better control, but in conjunction with co-interventions (including systematic medication titration by doctors, pharmacists, or patients; education; or lifestyle counselling) leads to clinically significant BP reduction which persists for at least 12 months. The implementation of self-monitoring in hypertension should be accompanied by such co-interventions.


Asunto(s)
Monitoreo Ambulatorio de la Presión Arterial/métodos , Presión Sanguínea , Hipertensión/prevención & control , Hipertensión/fisiopatología , Antihipertensivos/uso terapéutico , Humanos , Hipertensión/tratamiento farmacológico , Estilo de Vida , Educación del Paciente como Asunto , Ensayos Clínicos Controlados Aleatorios como Asunto
15.
Pulse (Basel) ; 3(3-4): 205-16, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27195242

RESUMEN

Accumulating evidence indicates that central blood pressure (CBP) is a better cardiovascular risk predictor than brachial blood pressure (BP). Although more additional benefits of CBP-based treatment above usual hypertension treatment are to be demonstrated, the demand for implementing CBP assessment in general clinical practice is increasing. For this, the measurement procedure must be noninvasive, easy to perform, and cost- and time-efficient. Therefore, oscillometric devices with the possibility to assess CBP seem the best option. Recently, such an oscillometric BP monitor, the Microlife WatchBP Office Central, was developed, which demonstrated its high accuracy in a validation study against invasive BP measurement. Calibration errors of this device are limited because the procedure is automated, standardized, and performed at the same place of and within 30 s from pulse wave assessment. The transformation from the peripheral pulse wave to CBP is done by means of an individual-based pulse wave analysis according to a theory of arterial compliance and wave reflections. In addition, the device has demonstrated to enable a more reliable diagnosis of hypertension by CBP than by peripheral BP, with a lower frequency of over- and underdiagnosis. Altogether, the available clinical evidence suggests that the Microlife WatchBP Office Central fulfills the criteria for general clinical use.

16.
BMJ Open ; 6(4): e010745, 2016 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-27072571

RESUMEN

OBJECTIVE: Timely detection of atrial fibrillation (AF) may effectively prevent cardiovascular consequences. However, traditional diagnostic tools are either poorly reliable (pulse palpation) or not readily accessible (ECG) in general practice. We tested whether an automatic oscillometric blood pressure (BP) monitor embedded with an algorithm for AF detection might be effective for opportunistic screening of asymptomatic AF in the community. SETTING: A community-based screening campaign in an unselected population to verify the feasibility of AF screening with a Microlife WatchBP Office BP monitor with a patented AFIB algorithm. When possible AF was detected (≥2 of 3 BP measurements reporting AF), a doctor immediately performed a single-lead ECG in order to confirm or exclude the presence of the arrhythmia. The main demographic and clinical data were also collected. PARTICIPANTS: 220 consecutive participants from an unselected sample of individuals in a small Italian community. PRIMARY AND SECONDARY OUTCOME MEASURES: Number of patients detected with AF and diagnosed risk factors for AF. RESULTS: In 12 of 220 participants, the device detected possible AF during the BP measurement: in 4 of them (1.8%), the arrhythmia was confirmed by the ECG. Patients with AF were more likely to be older (77.0±1.2 vs 57.2±15.2 years, p=0.010), obese (50.0 vs 14.4%, p=0.048) and to suffer from a cardiovascular disease (50.0 vs 10.6%, p=0.014) than patients without AF. Participants with a positive BP AF reading and non-AF arrhythmias (n=8) did not differ in their general characteristics from participants with a negative BP AF reading and were younger than patients with AF (mean age 56.4±14.8, p=0.027; 5 of 8 participants aged <65 years). CONCLUSIONS: Opportunistic screening of AF by BP measurement is feasible to diagnose this arrhythmia in unaware participants, particularly in those older than 65 years, who are the target patient group recommended by current AF screening guidelines.


Asunto(s)
Algoritmos , Fibrilación Atrial/diagnóstico , Monitoreo Ambulatorio de la Presión Arterial , Servicios de Salud Comunitaria , Técnicas de Diagnóstico Cardiovascular , Tamizaje Masivo/métodos , Oscilometría , Adulto , Anciano , Anciano de 80 o más Años , Presión Sanguínea , Monitoreo Ambulatorio de la Presión Arterial/instrumentación , Monitoreo Ambulatorio de la Presión Arterial/métodos , Técnicas de Diagnóstico Cardiovascular/instrumentación , Electrocardiografía , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Médicos , Características de la Residencia , Esfigmomanometros , Adulto Joven
17.
Int J Cardiol ; 203: 465-73, 2016 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-26547741

RESUMEN

Several guidelines recommend opportunistic screening for atrial fibrillation (AF) in subjects aged ≥ 65 years using pulse palpation during routine blood pressure (BP) measurement. However, this method has limited diagnostic accuracy. A specific algorithm for AF detection during automated BP measurement was developed and implemented in a novel oscillometric device (Microlife WatchBP Home-A). In 2013, the UK National Institute for Health and Care Excellence (NICE) recommended this device for AF screening during routine office BP measurement in primary care in subjects ≥ 65 years. A review and meta-analysis of the evidence on the diagnostic accuracy of this algorithm were performed. Six studies (n=2332) investigated the accuracy of AF detection using the Microlife BP monitor and estimated a pooled sensitivity at 0.98 (95% CI 0.95, 1.00) and specificity 0.92 (0.88, 0.96). Analysis of 4 studies (n=1126) showed more readings to improve specificity (from 0.86 to 0.91) and sensitivity (from 0.97 to 0.99). Taking 3 sequential readings with at least 2 detecting AF gave the highest diagnostic accuracy. A single study (n=139) of paroxysmal AF screening with home BP monitoring (3316 days) showed sensitivity 99% and specificity 93%. Another study (n=46) of AF screening with 24h ambulatory BP monitoring showed that AF detected in >15% of all readings has high probability of AF diagnosis requiring confirmation by 24h electrocardiography. AF detection with routine automated BP measurement is a reliable screening tool in the elderly, which requires confirmation by electrocardiography. Paroxysmal AF might also be detected by routine automated home or ambulatory BP monitoring.


Asunto(s)
Fibrilación Atrial/diagnóstico , Determinación de la Presión Sanguínea/métodos , Monitores de Presión Sanguínea , Frecuencia Cardíaca , Envejecimiento , Fibrilación Atrial/fisiopatología , Determinación de la Presión Sanguínea/instrumentación , Diagnóstico Precoz , Práctica Clínica Basada en la Evidencia , Guías como Asunto , Humanos , Metaanálisis como Asunto , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad
18.
Expert Rev Med Devices ; 9(6): 635-40, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23249156

RESUMEN

Atrial fibrillation (AF) is a significant risk factor for stroke and early detection of AF may help to identify patients in need of treatment. Automated blood pressure (BP) monitors with implemented AF or arrhythmia detection systems may be a useful tool for early diagnosis of AF. A systematic review (Medline/PubMed, Embase, Cochrane) of studies was performed to assess the accuracy of modified BP monitors (for diagnosing AF). A total of five studies (four tests in the physician's office and one at home) were selected. For the most accurate AF detection, three sequential BP measurements should be performed. Direct comparison against a 12-lead ECG showed that the highest sensitivity, 97% (95% CI: 94-100%), for detecting AF was obtained when three readings were assessed with two or three AF-positive readings. The highest specificity (97%) was obtained when performing three measurements, of which all three must be AF positive. The modified BP monitor (Microlife Corporation, Taipei, Taiwan) has high potential in improving AF screening.


Asunto(s)
Fibrilación Atrial/diagnóstico , Monitores de Presión Sanguínea , Oscilometría/instrumentación , Monitoreo Ambulatorio de la Presión Arterial/instrumentación , Humanos , Pulso Arterial
19.
Hypertens Res ; 35(9): 883-91, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22739420

RESUMEN

Measurement of the ankle-brachial index (ABI) using a Doppler device is widely used to identify subjects with peripheral artery disease (PAD), and those who are at high risk of cardiovascular disease. This paper presents a systematic review (Medline/PubMed, Embase and Cochrane) and meta-analysis of studies assessing the usefulness of automated oscillometric devices for ABI estimation and PAD detection compared with the conventional Doppler method. A total of 25 studies including 4186 subjects were analyzed. A random-effects model analysis showed that the average oscillometric ABI was similar to the Doppler ABI (mean difference ± s.e. 0.020 ± 0.018, P=0.3) but that the absolute differences were significant (0.048 ± 0.009, P<0.01). The pooled correlation coefficient (r) between the oscillometric and Doppler ABI was 0.71 ± 0.05. Simultaneous arm-leg measurements resulted in a smaller difference between the average oscillometric ABI value and the average Doppler ABI value than did sequential measurements (-0.012 ± 0.022 vs. 0.040 ± 0.026, respectively, P<0.01). The average sensitivity and specificity of the oscillometric ABI estimation in PAD diagnosis was 69 ± 6% and 96 ± 1%, respectively (with Doppler ABI taken as the reference). These data suggest that an automated ABI measurement obtained by oscillometric blood pressure monitors is a reliable and practical alternative to the conventional Doppler measurement for the detection of PAD. To increase the sensitivity of the PAD diagnosis based on an oscillometric ABI, a higher threshold of 1.0 might be preferable.


Asunto(s)
Índice Tobillo Braquial/métodos , Oscilometría/métodos , Presión Sanguínea/fisiología , Enfermedades Cardiovasculares/diagnóstico , Humanos , Enfermedad Arterial Periférica/diagnóstico , Enfermedad Arterial Periférica/diagnóstico por imagen , Ultrasonografía Doppler/métodos
20.
Am J Hypertens ; 25(1): 54-9, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21993365

RESUMEN

BACKGROUND: Although it is generally acknowledged that electronic monitoring of adherence to treatment improves blood pressure (BP) control by increasing patients' awareness to their treatment, little information is available on the long-term effect of this intervention. METHODS: In this observational study among a total of 470 patients with mild-to-moderate hypertension, adherence was measured in 228 patients by means of both the Medication Event Monitoring System (MEMS) and pill count (intervention group), and in 242 patients by means of pill count alone (control group). During a follow-up period of 1 year consisting of seven visits to the physician's office, BP measurements were performed and medication adjusted based on the achieved BP. In addition, at each visit adherence to treatment was assessed. RESULTS: On the basis of pill counts, median adherence to treatment did not differ between the intervention group and the control group (96.1% vs. 94.2%; P = 0.97). In both groups, systolic and diastolic BP decreased similarly: 23/13 vs. 22/12 mm Hg in the intervention and control group respectively. Drug changes and the number of drugs used were associated with BP at the start of study, but not with electronic monitoring. CONCLUSIONS: In this study, electronic monitoring of adherence to treatment by means of MEMS did not lead to better long-term BP control nor did it result in less drug changes and drug use.


Asunto(s)
Antihipertensivos/uso terapéutico , Presión Sanguínea/efectos de los fármacos , Hipertensión/tratamiento farmacológico , Adulto , Antihipertensivos/administración & dosificación , Determinación de la Presión Sanguínea , Monitoreo Ambulatorio de la Presión Arterial , Monitoreo de Drogas , Femenino , Estudios de Seguimiento , Humanos , Hipertensión/fisiopatología , Masculino , Persona de Mediana Edad , Cooperación del Paciente
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...