Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Med Hypotheses ; 135: 109477, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31756588

RESUMEN

INTRODUCTION: Regular monitoring of uncomplicated type B aortic dissection is essential because 25-30% will progress to aneurysmal form. The predictive factors of this evolution are not clearly defined, but they seem to be correlated with hemodynamic data. HYPOTHESIS: Our goal is to create a patient-specific and real-time model of numerical simulation of the hemodynamics of uncomplicated type B aortic dissections in order to predict the evolution of these pathologies for earlier treatment. METHOD: This model consists in a coupling 0D (hydraulic-electric analogy) - 3D (CT angiography segmentation) of the aortic arch with optimization by comparison to the 2D Phase Contrast MRI data and using Reduced Order Models to drastically reduce computing times. We tested our model on a healthy and a dissected patient. Then we realized different systolic blood pressure scenarios for each case, which we compared. RESULTS: In the dissected patient, the blood pressure at the false lumen wall was less important than the true lumen. Furthermore, the aortic wall shear stress and the velocity fields in aorta increase at the entry and re-entry tears between the two lumens. The simulation of different blood pressures scenarios shows a decrease in all these three parameters related to the decrease of the systolic blood pressure. CONCLUSION: Our model provides reliable patient-specific and real-time 3D rendering. It has also allowed us to realize different flow variation scenarios to simulate different clinical conditions and to compare them. However, the model still needs improvement in view of a daily clinical application.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Disección Aórtica/fisiopatología , Disección Aórtica/epidemiología , Aneurisma de la Aorta/patología , Presión Sanguínea , Simulación por Computador , Femenino , Hemodinámica , Humanos , Hidrodinámica , Imagen por Resonancia Magnética , Masculino , Modelos Cardiovasculares , Estrés Mecánico , Sístole , Tomografía Computarizada por Rayos X
2.
Eur J Clin Microbiol Infect Dis ; 39(4): 629-635, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31773364

RESUMEN

The optimal timing of cardiac surgery in infective endocarditis (IE) remains debated: Early surgery decreases the risk of embolism, and heart failure, but is associated with an increased rate of positive valve culture. To determine the determinants, and the consequences, of positive valve culture when cardiac surgery is performed during the acute phase of IE, we performed a retrospective study of adult patients who underwent cardiac surgery for definite left-sided IE (Duke Criteria), in two referral centres. During the study period (2002-2016), 148 patients fulfilled inclusion criteria. Median age was 65 years [interquartile range, 53-73], male-to-female ratio was 2.9 (110/38). Cardiac surgery was performed after 14 days [5-26] of appropriate antibiotics. Valve cultures returned positive in 46 cases (31.1%). Factors independently associated with positive valve culture were vegetation size ≥ 10 mm (OR 2.83 [1.16-6.89], P = 0.022) and < 14 days of appropriate antibacterial treatment before surgery (OR 4.68 [2.04-10.7], P < 0.001). Positive valve culture was associated with increased risk of postoperative acute respiratory distress syndrome (37.0% vs. 15.7%, P = 0.008) but was associated neither with an increased risk of postoperative relapse nor with the need for additional cardiac surgery. Duration of appropriate antibacterial treatment and vegetation size are independently predictive of positive valve culture in patients operated during the acute phase of IE. Positive valve culture is associated with increased risk of postoperative acute respiratory distress syndrome.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/normas , Endocarditis Bacteriana/microbiología , Endocarditis Bacteriana/cirugía , Válvulas Cardíacas/microbiología , Enfermedad Aguda , Anciano , Antibacterianos/uso terapéutico , Bacterias/aislamiento & purificación , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/métodos , Recuento de Colonia Microbiana , Endocarditis Bacteriana/tratamiento farmacológico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Síndrome de Dificultad Respiratoria/etiología , Estudios Retrospectivos , Factores de Riesgo
3.
Ann Cardiol Angeiol (Paris) ; 67(6): 455-465, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30376969

RESUMEN

Aortic stenosis is a frequent disease in the elderly. Its prevalence is 0.4% with a sharp increase after the age of 65, and its outcome is very poor when the patient becomes symptomatic. The interventional procedure known as TAVI (trans-catheter aortic valve implantation), which was developed in France and carried out for the first time in Rouen by Prof. Alain Cribier and his team in 2002, has proven to be a valid alternative to surgical aortic valve replacement. At first, this technique was shown to be efficient in patients with contra-indications to surgical treatment or deemed to be at high surgical risk. Given the very promising outcomes achieved as a result of close heart team collaboration, appropriate patient selection, simplified procedures and reduced complication rates, transfemoral (TF) TAVI is now preferred in symptomatic intermediate risk patients>75 years old according to the latest ESC guidelines. In 2017, in France, TAVI is currently performed in 50 centers with on-site cardiac surgery. The 2016 TAVI outcomes recorded in the French national TAVI registry (France TAVI) are very encouraging and show that for 7133 patients treated (age 83.4±7 years, logistic Euroscore 14%), 87% of whom via the TF approach, cross-over to surgery was very low (0.5%) with a 3.0% in-hospital mortality rate. The substantial increase in TAVI indications and the improvement of its outcomes may in the near future call for a reconsideration of the number of high volume centers authorized to carry out this technique.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter , Anticoagulantes/uso terapéutico , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/epidemiología , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/epidemiología , Diagnóstico por Imagen , Francia/epidemiología , Prótesis Valvulares Cardíacas , Mortalidad Hospitalaria , Humanos , Selección de Paciente , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
4.
Ann Cardiol Angeiol (Paris) ; 66(1): 26-31, 2017 Feb.
Artículo en Francés | MEDLINE | ID: mdl-28129901

RESUMEN

The history of infective endocarditis (IE) is a good example of medical progress. Initially incurable, endocarditis, when diagnosed, was synonym of death. After significant diagnostic progress, thanks to Osler's contribution especially, the first surgeries and antibacterial drugs obtained very few successful cures. We had to wait until Flamming's discovery to observe frequent cures thanks to antibiotics. Surgery manages to push possibilities of cure a bit further. However, paravalvular extensions, described since the first surgical case of IE, was a real technical matter. Thus, the second half of 20th century was devoted to overcoming this surgical challenge. In this historical review, we describe the story of severe IE, especially with paravalvular involvement, by highlighting major progress - clinical and surgical, that allows its current management.


Asunto(s)
Cardiología/historia , Endocarditis/historia , Cirugía Torácica/historia , Inglaterra , Historia del Siglo XVII , Historia del Siglo XVIII , Historia del Siglo XIX , Historia del Siglo XX
5.
Rev Mal Respir ; 31(7): 591-600, 2014 Sep.
Artículo en Francés | MEDLINE | ID: mdl-25239580

RESUMEN

BACKGROUND: Thymic epithelial tumors (TET), including thymomas and thymic carcinomas, are rare and characterized by very different evolutionary patterns depending on histology and invasion stage. The therapeutic management is not well defined but is a subject of increasing interest. The descriptive and analytic objectives of this retrospective monocentric study were to analyze the clinical characteristics of patients with TET, and to assess the management of these tumors in our centre. METHODS: Adult patients with TET managed in the Rennes university hospital in the period 2000-2011 were selected via the pathology department. Their clinical and pathological features and survival were analyzed retrospectively. RESULTS: Fifty TET were retrieved (46 thymomas and 4 thymic carcinomas). Their clinical and histological features and their invasion stages were concordant with published studies. Their diagnostic and therapeutic managements were also in accordance with current guidelines. In univariate analysis, myasthenia and surgery were associated with better survival rates. CONCLUSION: Management of TET in Rennes university hospital is in accordance with guidelines.


Asunto(s)
Neoplasias Glandulares y Epiteliales/diagnóstico , Neoplasias Glandulares y Epiteliales/terapia , Neoplasias del Timo/diagnóstico , Neoplasias del Timo/terapia , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Francia , Hospitales Universitarios , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
6.
Artículo en Inglés | MEDLINE | ID: mdl-24110703

RESUMEN

The main objective of this work is to track the aortic valve plane in intra-operative fluoroscopic images in order to optimize and secure Transcatheter Aortic Valve Implantation (TAVI) procedure. This paper is focused on the issue of aortic valve calcifications tracking in fluoroscopic images. We propose a new method based on the Tracking-Learning-Detection approach, applied to the aortic valve calcifications in order to determine the position of the aortic valve plane in intra-operative TAVI images. This main contribution concerns the improvement of object detection by updating the recursive tracker in which all features are tracked jointly. The approach has been evaluated on four patient databases, providing an absolute mean displacement error less than 10 pixels (≈2mm). Its suitability for the TAVI procedure has been analyzed.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/patología , Calcinosis/cirugía , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Calcinosis/diagnóstico , Cateterismo Cardíaco , Fluoroscopía/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Interpretación de Imagen Asistida por Computador , Monitoreo Intraoperatorio , Cirugía Asistida por Computador
7.
Rev Pneumol Clin ; 69(3): 144-8, 2013 Jun.
Artículo en Francés | MEDLINE | ID: mdl-23597633

RESUMEN

Primitive tumors of the trachea are rare, accounting for 0.1% of the airway tumors. Cystic adenoid carcinoma (or cylindroma) represents the second most frequent type of tracheal cancers. Histologically speaking, this tumor type is divided in three patterns: cribriform, tubular and solid; it presents a slow growth, perineural invasion and potential local recurrence and metastasis. We presented herein the case of a 56-year-old female suffering from a cystic adenoid carcinoma of the low trachea. She has been treated by carinal resection with negative airway margin and complete reconstruction, with the help of an extra corporeal membrane oxygenation (ECMO).


Asunto(s)
Carcinoma Adenoide Quístico/terapia , Oxigenación por Membrana Extracorpórea , Neoplasias de la Tráquea/terapia , Carcinoma Adenoide Quístico/radioterapia , Carcinoma Adenoide Quístico/cirugía , Terapia Combinada , Femenino , Humanos , Persona de Mediana Edad , Procedimientos de Cirugía Plástica , Neoplasias de la Tráquea/radioterapia , Neoplasias de la Tráquea/cirugía
8.
Ann Cardiol Angeiol (Paris) ; 60(1): 15-20, 2011 Feb.
Artículo en Francés | MEDLINE | ID: mdl-20797692

RESUMEN

OBJECTIVE: Severely impaired patients may wait in France on a special and temporary high emergency national list (called SU). Some of these patients need mechanical circulatory support with ECMO. In order to compare two groups of patients on SU, who acceeded to heart transplantation (HT) with or without ECMO, we reviewed retrospectively 20 consecutive patients transplanted on SU between January 2004 and September 2007 in Rennes. PATIENTS AND METHODS: Among them, 10 were transplanted without ECMO and 10 others were implanted with a femoro-femoral ECMO before HT. RESULTS: (1) Considering the group SU without pretransplantation ECMO: 2 years survival rate was 70%. Mean hospital stay was 26.4 days. Three patients were implanted with ECMO for graft dysfunction during postoperative course, without inherent complication. None graft dysfunction occurred after initial hospitalization; (2) considering the group SU with pretransplantation ECMO: 2 years survival rate was 90% (one early death). Mean hospital stay was 45 days with multiple complications due to the ECMO (leg's ischemia: n = 2; lung oedema: n = 1; lymphorrhea: n = 3, low flow requiring change of canulae: n = 1). None graft dysfunction occurred after initial hospitalization. CONCLUSION: Although we didn't reach statistical significance, it seems that ECMO for patients in SU may be useful as bridge to transplant but with a higher morbidity than for similar patients transplanted without ECMO. Additional data from other transplant centers are needed to confirm our findings.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Trasplante de Corazón , Adulto , Tratamiento de Urgencia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Tiempo , Listas de Espera
9.
J Radiol ; 90(7-8 Pt 1): 804-12, 2009.
Artículo en Francés | MEDLINE | ID: mdl-19752785

RESUMEN

PURPOSE: To report our experience with endovascular stent-graft repair of descending thoracic aorta diseases in high risk patients. MATERIALS AND METHODS: Between 2000 and 2007, 49 high surgical risk patients (mean age: 64.6 years) underwent stent-graft placement, including 24 cases presenting acutely. Mean follow-up was 25.4 months. Etiologies included 15 aneurysms, 11 dissections, 10 penetrating ulcers, 9 false aneurysms, 2 ruptures of the aortic isthmus, 2 intramural hematomas. RESULTS: Access failure occurred in one patient. The overall mortality was 27.1% (n=13), nine related to the presenting pathology or treatment. Thirty-day mortality was 10.4% (n=5). Complications included vascular injury at the iliac or femoral artery access (10.2%), 1 case of flaccid paraplegia, 2 cases of transient paraparesis, 2 strokes, 2 stent migrations and 1 stent rupture. The rate of early endoleak was 39.6% while the rate of delayed endoleak was 14.6%. Seven patients (14.6%) required repeat endovascular interventions. Explantation was required in 2 cases. The latest available follow-up showed no lesion enlargement in 70.7% (n=29/41) of our patients. CONCLUSION: Descending thoracic aortic pathology can be treated using endografts in high risk patients, although significant morbidity and mortality remain. Because of the high rate of endoleaks, close follow-up is required.


Asunto(s)
Aorta Torácica , Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Rotura de la Aorta/cirugía , Implantación de Prótesis Vascular , Stents , Análisis Actuarial , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/mortalidad , Rotura de la Aorta/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Radiografía Torácica , Factores de Riesgo , Factores de Tiempo , Tomografía Computarizada por Rayos X/métodos
11.
Arch Mal Coeur Vaiss ; 98(12): 1192-8, 2005 Dec.
Artículo en Francés | MEDLINE | ID: mdl-16435597

RESUMEN

Transoesophageal echocardiography has shown a high incidence on non-obstructive thrombosis after mitral valve replacement with a mechanical prosthesis. The unpredictable outcome and the period during which the complication arises make treatment difficult. The aim of this study was to assess the tolerance and efficacy of the association of long-term heparin and oral anticoagulation, as recommended in this indication. All patients undergoing mitral valve replacement with a mechanical prosthesis between June 1999 and July 2001 were systematically included and studied by transoesophageal echocardiography in the immediate postoperative period. Those with non-obstructive thrombosis at least 5 mm in size were treated by heparin and oral coagulation until the thrombus disappeared on transoesophageal echocardiography. One hundred and fourteen patients undergoing 120 mitral valve replacements (6 reoperations) underwent transoesophageal echocardiography and non-obstructive thrombi measuring at least 5 mm were found on 26 occasions (21.7%). The association of heparin and oral coagulation was maintained for 7 to 115 days (average 20 days). No thromboembolic or haemorrhagic complications and no deaths were observed during this period. Two patients were treated with danaparoid and oral anticoagulation because of heparin-induced thrombocytopenia before the diagnosis. None of the patients died during follow-up (average 49 months); there were 4 recurrent non-obstructive thromboses, three of which were complicated by thromboembolic events with no sequellae in the first 8 months, again treated effectively with the association of heparin and oral anticoagulants; two cerebral embolic events without sequellae were observed without a demonstrable non-obstructive thrombus on transoesophageal echocardiography. The authors conclude that the association of heparin and oral anticoagulants seems well tolerated and effective in this small population and this would justify a large scale clinical trial.


Asunto(s)
Prótesis Valvulares Cardíacas/efectos adversos , Válvula Mitral/cirugía , Trombosis/etiología , Adulto , Anciano , Anticoagulantes/uso terapéutico , Aspirina/uso terapéutico , Quimioterapia Combinada , Ecocardiografía Transesofágica , Femenino , Fibrinolíticos/uso terapéutico , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/etiología , Enfermedades de las Válvulas Cardíacas/cirugía , Heparina/uso terapéutico , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Estudios Retrospectivos , Trombosis/diagnóstico por imagen , Trombosis/tratamiento farmacológico , Resultado del Tratamiento , Vitamina K/antagonistas & inhibidores
12.
Respiration ; 69(5): 456-60, 2002.
Artículo en Inglés | MEDLINE | ID: mdl-12232456

RESUMEN

Among embryonic aortic vascular malformations, persistence of a right aortic arch and aberrant left subclavian artery associated with a diverticulum of Kommerell is rare, and is estimated to occur in 0.1% of the general population. We report two cases of diverticulum of Kommerell in which tracheal compression due to the vascular ring induced respiratory symptoms such as asthmatic dyspnoea. This reminds us that at least a chest X-ray should be performed in newly diagnosed asthmatic patients, focusing on the trachea and upper mediastinum. In case of vascular abnormality, angiography and magnetic resonance are the best investigations to define the abnormal anatomy and guide surgery.


Asunto(s)
Aorta Torácica/anomalías , Asma/diagnóstico , Divertículo/diagnóstico , Adulto , Aorta Torácica/cirugía , Diagnóstico Diferencial , Divertículo/congénito , Divertículo/cirugía , Femenino , Humanos , Arteria Subclavia/anomalías , Arteria Subclavia/trasplante , Estenosis Traqueal/etiología
13.
Eur J Cardiothorac Surg ; 20(5): 918-22, 2001 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-11675175

RESUMEN

OBJECTIVE: The objective of this study was to analyze the feasibility of beating heart coronary surgery and to angiographically assess complete revascularisations with routine use of the two internal thoracic arteries (ITA), with the right ITA pedicled and placed through the transverse sinus. The authors report the results of their initial experience of coronary surgery without CPB, which began in December 1998. METHODS: From December 1998 to October 1999, 50 patients underwent non-urgent beating heart coronary revascularisation via a median sternotomy with the 2 ITA. Stabilization of the anastomotic site was ensured by the Octopus stabilizer 1 then 2. A troponin Ic assay was systematically performed in the initial postoperative period. With the patient's consent, postoperative angiography was performed before discharge. RESULTS: The mean number of anastomoses was 2.5+/-0.6 per patient (range: 2-4). Distal anastomoses by arterial grafts were performed in 87% of cases. In one case, the right ITA could not be kept pedicled and tunnelled in the transverse sinus and a Y graft onto the left ITA had to be performed. Left anterior descending-diagonal sequential bypass with the left ITA was performed in seven patients (14%). There was no operative mortality. One patient developed postoperative myocardial infarction. Follow-up angiography was performed in 42 cases (84%), with 104 anastomoses reviewed (85%). The patency rate for all anastomoses was 98.1%, with 90.4% of excellent results. The patency rate of the right ITA was 100%, with 90.5% of excellent results. CONCLUSIONS: Beating heart coronary surgery allows revascularisation of all coronary territories. This technique is not an obstacle to the use of the pedicled right ITA tunnelled in the transverse sinus. It is not associated with an increased postoperative morbidity and mortality, and the early follow-up angiographic results are excellent.


Asunto(s)
Arterias Mamarias/cirugía , Revascularización Miocárdica/métodos , Anciano , Anastomosis Quirúrgica , Angiografía Coronaria , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Grado de Desobstrucción Vascular
14.
J Heart Valve Dis ; 10(4): 443-8, 2001 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-11499587

RESUMEN

BACKGROUND AND AIM OF THE STUDY: Few long-term data are available on the Carpentier-Edwards Standard bioprosthesis in the mitral position. As for other bioprostheses, patient age at the time of implant is the main risk factor for structural deterioration, but no published report has analyzed the life-span of these bioprostheses with respect to this parameter. METHODS: A series of 139 patients who underwent mitral valve replacement with the Carpentier-Edwards Standard bioprosthesis between 1978 and 1987 was reviewed. Mean age at implant was 59.6+/-14.7 years (range: 17-79 years). Follow up was 98.4% complete; total follow up was 1,078.7 patient-years (pt-yr) (mean 8.4+/-4.1 years). Mean follow up in the subgroup of patients alive at the time of the survey was 10.4+/-3.4 years. RESULTS: Structural valve deterioration (SVD) occurred in 30 patients, with mean time to onset of deterioration 9.0+/-2.7 years (median 8.7 years). This time was independent of age at the time of implantation. Analysis by age group (< or =35, 36-50, 51-60, 61-65, 66-70, >70 years) showed deterioration to be more frequent in younger subjects (linear rates 7.9, 6.0, 3.3, 2.4, 0.6 and 0.4% pt-yr, respectively). Over the age of 65 years, the risk of SVD no longer varied with age, and was a rare complication. CONCLUSION: The mean time to onset of SVD was independent of patient age at the time of implant. After 65 years, the risk of SVD was low, without any significant variation. The Carpentier-Edwards Standard bioprosthesis may be used in the mitral position in subjects aged over 65 years, and with a low risk of deterioration.


Asunto(s)
Bioprótesis , Supervivencia de Injerto , Prótesis Valvulares Cardíacas , Válvula Mitral/cirugía , Adolescente , Adulto , Distribución por Edad , Factores de Edad , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Estudios Retrospectivos , Factores de Tiempo
15.
Bull Acad Natl Med ; 185(1): 163-74; discussion 174-5, 2001.
Artículo en Francés | MEDLINE | ID: mdl-11474565

RESUMEN

Aortic stenosis (AS) is the most common lesion currently encountered among valvular heart disease, particularly in elderly people. Severe functional impairment and risk of sudden death explain that surgical treatment is largely accepted. We report a retrospective analysis of institutional experience with aortic valve replacement (AVR) for AS from 1971-1997 in 4,129 patients. Age ranged from 13 to 91 years (mean 68 +/- 10) and degenerative disease was largely predominant (86%). For AVR, mechanical prostheses were used in 2,054 patients (50.2%) and bioprostheses in 2,075 (48.8%) in elderly group. Coronary artery revascularization was associated in 670 patients (16%). Operative mortality was 7% (303 pts) and main cause was left ventricular failure (52%). Late results were studied with a maximum follow-up of 26 years. Total follow-up represents 21,533 pt-years. Late death occurred in 1,108 patients between 1 month and 24 years after operation (mean 6.6 years). Reoperation was necessary in 136 cases. Actuarial survival--including operative mortality--was 77% and 56% at 5 and 10 years. A large functional improvement was observed in the vast majority of patients, 73% being I or II subgroups of the NYHA classification. Incremental risk factors for death (immediate as well as late) were older age, preoperative functional status, emergency, presence of cardiac failure, coronary artery lesions and associated morbidity. The choice of valvular prosthesis remains controversial, but the results show that AVR is the procedure of choice for the vast majority of patients wtih significant aortic valve disease.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Calcinosis/cirugía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/mortalidad , Calcinosis/complicaciones , Calcinosis/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Calidad de Vida , Estudios Retrospectivos , Factores de Tiempo
16.
Ann Thorac Surg ; 71(5 Suppl): S228-31, 2001 May.
Artículo en Inglés | MEDLINE | ID: mdl-11388192

RESUMEN

BACKGROUND: The aim of the study was to evaluate the long-term results of aortic valve replacement with the Carpentier-Edwards supraannular porcine bioprosthesis. METHODS: A total of 278 patients who underwent aortic valve replacement between January 1983 and December 1986 were reviewed. Mean age was 69.4+/-11.0 years (range 24 to 90 years). RESULTS: The operative mortality was 8.6% (24 patients). The total follow-up was 2367.1 years (mean 9.3+/-4.3 years, maximum 15.5). The late mortality rate was 6.8%/patient-year (162 patients) and the overall survival at 15 years was 26.5%+/-3.6%. Structural valve deterioration (SVD) occurred in 19 patients (linearized rate 0.8%/ patient-year). The mean time to onset of deterioration was 10.9+/-2.9 years. This time was independent of the age at the time of implantation. The freedom from SVD at 10, 12, and 15 years for patients aged less than 60 was respectively 87.6%+/-6.8%, 77.8%+/-8.9%, and 44.2%+/-12.9% (linearized rate 3.3%/patient-year). For patients aged 61 to 70 years, freedom from SVD was, respectively, 100%, 97.3%+/-2.1%, and 80.8%+/-8.3% (linearized rate 0.63% patient-year). For patients older than 70 years, it was respectively 99.1%+/-0.9%, 95.6%+/-2.6%, and 93.3%+/-3.3% (linearized rate 0.31%/patient-year). No significant difference was observed below the age of 60 years (< or =50 vs 51 to 60 years) or in the older subgroups (61 to 70 years, vs >70 years). CONCLUSIONS: The Carpentier-Edwards supraannular bioprosthesis in aortic position provides low rate of structural valve deterioration at 15 years in patients aged more than 60 years at the time of implantation. The mean time to onset of SVD is independent of the subject's age at the time of implantation. After 60 years, the risk of deterioration is low and does not present any significant variation. The Carpentier-Edwards supraannular bioprosthesis can reliably be used for aortic valve replacement in patients over the age of 60 years because, beyond this age, SVD is observed much more rarely.


Asunto(s)
Válvula Aórtica/cirugía , Bioprótesis , Prótesis Valvulares Cardíacas , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/mortalidad , Diseño de Prótesis , Falla de Prótesis , Reoperación , Tasa de Supervivencia
17.
J Heart Valve Dis ; 10(2): 171-6, 2001 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-11297203

RESUMEN

BACKGROUND AND AIM OF THE STUDY: The study aim was to examine prospectively the clinical performance and durability of the Medtronic Mosaic bioprosthesis, a stented porcine aortic valve that combines improvements in tissue preservation, notably net zero differential pressure fixation of the leaflets, with antimineralization treatment using 2-amino-oleic acid (AOA). METHODS: A total of 158 Mosaic valves was implanted; 152 in patients aged over 70 years, and six in patients aged <70 years with contraindications to anticoagulant therapy. Mean age was 73.7 years. All valves were implanted in the supraannular position. Thirty-two patients (20%) required concomitant procedures, including coronary revascularization, ascending aorta replacement and/or mitral annuloplasty. Postoperative anticoagulation (heparin) was prescribed for ten days, followed by antiplatelet therapy. No long-term oral anticoagulants were prescribed, except in some patients with atrial fibrillation. The follow up included routine clinical and blood work-up, and echocardiography at six months and one year after surgery. RESULTS: There were seven early (0-30 days) and five late deaths (>30 days). One death was caused by a hemorrhagic stroke at three months in a patient without anticoagulant or antiplatelet therapy. No thromboembolic complications or structural valve deterioration were observed during follow up. At two years, freedom from endocarditis and reoperation was each 99.6%. NYHA class was excellent, with 98% of patients in class I or II at one year. Patient survival was 92% at two years. Hemodynamically, the valve was performing well, with mean systolic gradients of 13.6, 13.2, 12.6 and 9.6 mmHg for the 21, 23, 25 and 27 mm valves, respectively. There was no evidence of structural valve deterioration. CONCLUSION: Long-term evaluations are mandatory to confirm the durability of any new bioprosthetic valve. Satisfactory early clinical and hemodynamic results with the new Mosaic bioprosthesis warrant its continued implantation in the aortic position for patients over the age of 70 years.


Asunto(s)
Válvula Aórtica/fisiopatología , Válvula Aórtica/trasplante , Prótesis Valvulares Cardíacas , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Análisis de Falla de Equipo , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/fisiopatología , Enfermedades de las Válvulas Cardíacas/cirugía , Hemodinámica/fisiología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Tiempo , Ultrasonografía
18.
J Thorac Cardiovasc Surg ; 121(1): 68-76, 2001 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-11135161

RESUMEN

OBJECTIVE: We describe a Pearson-type technique and evaluate its results for postintubation subglottic stenosis. METHODS: Forty-five patients underwent a partial cricoidectomy with primary thyrotracheal anastomosis, and 5 underwent simultaneous repair of a tracheoesophageal fistula as well. Twenty-four (53%) patients were referred to us after initial conservative (n = 21) or operative (n = 3) management. There were 27 cuff lesions, 7 stomal lesions, and 11 at both levels. The upper limit of the stenosis was 1.5 cm (range, 1-2.5 cm) below the cords, and the subglottic diameter was reduced by 60% in 38 (84%) of the patients. The length of airway resection ranged from 2 to 6 cm (median, 3 cm). Despite 23 thyrohyoid or suprahyoid releases, 8 anastomoses were under tension. RESULTS: Thirty-seven (82%) patients were extubated after the operation (n = 30) or within 24 hours (n = 7). Six patients required postoperative airway stenting (median, 5.5 days). Early (<30 days) complications occurred in 18 (41%) patients, mainly as transient airway and voice complaints, aspiration, and dysphagia. One (2%) patient died of myocardial infarction. Late morbidities were 2 failures occurring as bilateral recurrent nerve paralysis and restenosis requiring definitive tracheostomy. Patients had excellent or good anatomic (n = 42 [96%]), functional (n = 41 [93%]), or both types of long-lasting results, with no stenotic relapse. CONCLUSIONS: Partial cricoidectomy with primary thyrotracheal anastomosis can be applied in patients with postintubation stenosis extending up to 1 cm below the cords and measuring up to 6 cm in length with excellent-to-good definitive results. The association with a tracheoesophageal fistula does not contraindicate surgical repair.


Asunto(s)
Cartílago Cricoides/cirugía , Intubación Intratraqueal/efectos adversos , Laringoestenosis/cirugía , Cartílago Tiroides/cirugía , Tráquea/cirugía , Adolescente , Adulto , Anciano , Anastomosis Quirúrgica/métodos , Anastomosis Quirúrgica/mortalidad , Niño , Preescolar , Femenino , Humanos , Laringoestenosis/etiología , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tasa de Supervivencia
19.
Am J Respir Crit Care Med ; 162(4 Pt 1): 1429-34, 2000 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-11029357

RESUMEN

Because long-term pulmonary artery (PA) obstruction is associated with expansion of the systemic blood supply to the lung, chronic ischemia may not occur, and endothelium nitric oxide synthase (eNOS) function may be preserved in postobstructive pulmonary arteries. To test this hypothesis, we studied piglets 2 d or 5 wk after left PA ligation or a sham operation. We measured left lung ATP and lactate lung concentrations; calcium-dependent and calcium-independent NOS activities and eNOS protein; and left PA relaxations in response to acetylcholine, calcium ionophore, and sodium nitroprusside. Decreases in ATP and increases in lactate concentrations were significantly attenuated after 5 wk PA occlusion (p < 0.05 versus sham and 2-d ligation). Compared with sham and 2-d PA occlusion, calcium-dependent NOS activity and eNOS protein were lower in the long-term PA occlusion group. Calcium-independent NOS activity was unchanged. Acetylcholine and calcium ionophore relaxations were impaired after 5 wk, whereas only acetylcholine relaxation was impaired after 2-d PA occlusion. Relaxation to sodium nitroprusside remained unchanged. In conclusion, despite relative conservation of lung energy metabolism, prolonged PA occlusion decreased eNOS function and protein in postobstructive pulmonary arteries.


Asunto(s)
Endotelio Vascular/fisiopatología , Isquemia/fisiopatología , Pulmón/irrigación sanguínea , Óxido Nítrico Sintasa/fisiología , Óxido Nítrico/fisiología , Embolia Pulmonar/fisiopatología , Adenosina Trifosfato/metabolismo , Animales , Metabolismo Energético/fisiología , Ácido Láctico/metabolismo , Arteria Pulmonar/fisiopatología , Porcinos
20.
J Thorac Cardiovasc Surg ; 119(2): 268-76, 2000 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-10649202

RESUMEN

OBJECTIVE: We evaluated the outcome of different surgical techniques for postintubation tracheoesophageal fistula. METHODS: Thirty-two consecutive patients aged 51 +/- 23 years had tracheoesophageal fistulas resulting from a median of 30 days of mechanical ventilation via endotracheal (n = 12) or tracheostomy (n = 20) tubes. Tracheoesophageal fistulas were 2.5 +/- 1.2 cm long and were associated with a tracheal (n = 10) or subglottic (n = 3) stenosis in 13 patients. RESULTS: All but 3 patients were weaned from respirators before repair. All operations were done through cervical incisions and included direct division and closure (n = 9), esophageal diversion (n = 3), muscle interposition (n = 6), or, more recently, tracheal or laryngotracheal resection and anastomosis with primary esophageal closure (n = 14). Nine thyrohyoid and two supralaryngeal releases reduced anastomotic tension. Twenty-three patients (74%) were extubated after the operation (n = 16) or within 24 hours (n = 7), and 7 required a temporary tracheotomy tube. One postoperative death (3%) was associated with recurrent tracheoesophageal fistula. Seven complications (22%) included recurrent tracheoesophageal fistula (n = 1), delayed tracheal stenosis (n = 2), dysphagia (n = 2), and recurrent nerve palsy (n = 2). Complications necessitated reoperation (n = 1), dilation (n = 2), definitive tracheostomy (n = 1), Montgomery T tubes (n = 1), and Teflon injection of the vocal cords (n = 1). Twenty-nine patients (93%) had excellent (n = 24) or good (n = 5) anatomic and functional long-term results. Complications have been less common (7% vs 38%) and long-term results better (93% vs 65%) recently with tracheal or laryngotracheal resection and anastomosis with primary esophageal closure as compared with previous procedures. CONCLUSIONS: Postintubation tracheoesophageal fistula is usually best treated with tracheal or laryngotracheal resection and anastomosis with primary esophageal closure even in the absence of tracheal damage.


Asunto(s)
Esofagoplastia/métodos , Esófago/cirugía , Intubación Intratraqueal/efectos adversos , Tráquea/cirugía , Fístula Traqueoesofágica/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Anastomosis Quirúrgica , Colon/trasplante , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tasa de Supervivencia , Fístula Traqueoesofágica/etiología , Fístula Traqueoesofágica/mortalidad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA