1.
Radiat Prot Dosimetry ; 199(15-16): 1968-1972, 2023 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-37819306

RESUMEN

In proton therapy, most treatment planning systems (TPS) use a fixed relative biological effectiveness (RBE) of 1.1 all along the depth-dose profile. Innovative TPS are now investigated considering the variability of RBE with radiation quality. New TPS need an experimental verification in the quality assurance (QA) routine in clinics, but RBE data are usually obtained with radiobiological measurements that are time consuming and not suitable for daily QA. Microdosimetry is a useful tool based on physical measurements which can monitor the radiation quality. Several microdosimeters are available in different research institutions, which could potentially be used for the QA in TPS. In this study, the response functions of five detectors in the same 62-MeV proton Spread Out Bragg Peak is compared in terms of spectral distributions and their average values and microdosimetric RBE. Their different response function has been commented and must be considered in the clinical practice.


Asunto(s)
Terapia de Protones , Protones , Radiometría , Efectividad Biológica Relativa
2.
Sci Rep ; 9(1): 11498, 2019 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-31395962

RESUMEN

Layered double hydroxides show intriguing physical and chemical properties arising by their intrinsic self-assembled stacking of molecular-thick 2D nanosheets, enhanced active surface area, hosting of guest species by intercalation and anion exchanging capabilities. Here, we report on the unprecedented emerging intense ultraviolet photoluminescence in Zn/Al layered double hydroxide high-aspect-ratio nanoplatelets, which we discovered to be fully activated by drying under vacuum condition and thermal desorption as well. Photoluminescence and its quenching were reproducibly switched by a dehydration-hydration process. Photoluminescence properties were comprehensively evaluated, such as temperature dependence of photoluminescence features and lifetime measurements. The role of 2D morphology and arrangement of hydroxide layers was demonstrated by evaluating the photoluminescence before and after exfoliation of a bulk phase synthetized by a coprecipitation method.

3.
Nanotechnology ; 29(37): 375704, 2018 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-29947334

RESUMEN

The accurate determination of the geometrical features of quasi one-dimensional nanostructures is mandatory for reducing errors and improving repeatability in the estimation of a number of geometry-dependent properties in nanotechnology. In this paper a method for the reconstruction of length and spatial orientation of single nanowires (NWs) is presented. Those quantities are calculated from a sequence of scanning electron microscope (SEM) images taken at different tilt angles using a simple 3D geometric model. The proposed method is evaluated on a collection of SEM images of single GaAs NWs. It is validated through the reconstruction of known geometric features of a standard reference calibration pattern. An overall uncertainty of about 1% in the estimated length of the NWs is achieved.

5.
Med Phys ; 43(9): 5205, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27587052

RESUMEN

PURPOSE: Small field output correction factors have been studied by several research groups for the PTW 60019 microDiamond (MD) dosimeter, by comparing the response of such a device with both reference dosimeters and Monte Carlo simulations. A general good agreement is observed for field sizes down to about 1 cm. However, evident inconsistencies can be noticed when comparing some experimental results and Monte Carlo simulations obtained for smaller irradiation fields. This issue was tentatively attributed by some authors to unintentional large variations of the MD active surface area. The aim of the present study is a nondestructive experimental determination of the MD active surface area and active volume. METHODS: Ten MD dosimeters, one MD prototype, and three synthetic diamond samples were investigated in the present work. 2D maps of the MD response were recorded under scanned soft x-ray microbeam irradiation, leading to an experimental determination of the device active surface area. Profiles of the device responses were measured as well. In order to evaluate the MD active volume, the thickness of the diamond sensing layer was independently evaluated by capacitance measurements and alpha particle detection experiments. The MD sensitivity, measured at the PTW calibration laboratory, was also used to calculate the device active volume thickness. RESULTS: An average active surface area diameter of (2.19 ± 0.02) mm was evaluated by 2D maps and response profiles of all the MDs. Average active volume thicknesses of (1.01 ± 0.13) µm and (0.97 ± 0.14) µm were derived by capacitance and sensitivity measurements, respectively. The obtained results are well in agreement with the nominal values reported in the manufacturer dosimeter specifications. A homogeneous response was observed over the whole device active area. Besides the one from the device active volume, no contributions from other components of the housing nor from encapsulation materials were observed in the 2D response maps. CONCLUSIONS: The obtained results demonstrate the high reproducibility of the MD fabrication process. The observed discrepancies among the output correction factors reported by several authors for MD response in very small fields are very unlikely to be ascribed to unintentional variations of the device active surface area and volume. It is the opinion of the authors that the role of the volume averaging as well as of other perturbation effects should be separately investigated instead, both experimentally and by Monte Carlo simulations, in order to better clarify the behaviour of the MD response in very small fields.


Asunto(s)
Diamante , Radiometría/instrumentación , Método de Montecarlo , Reproducibilidad de los Resultados , Propiedades de Superficie
6.
Med Phys ; 42(8): 4636-44, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26233191

RESUMEN

PURPOSE: Aim of the present work is to evaluate the synthetic single crystal diamond Schottky photodiode developed at the laboratories of "Tor Vergata" University in Rome in a new dosimeter configuration specifically designed for offline wireless in vivo dosimetry (IVD) applications. METHODS: The new diamond based dosimeter, single crystal diamond detector (SCDD-iv), consists of a small unwired detector and a small external reading unit that can be connected to commercial electrometers for getting the detector readout after irradiation. Two nominally identical SCDD-iv dosimeter prototypes were fabricated and tested. A basic dosimetric characterization of detector performances relevant for IVD application was performed under irradiation with (60)Co and 6 MV photon beams. Preirradiation procedure, response stability, short and long term reproducibility, leakage charge, fading effect, linearity with dose, dose rate dependence, temperature dependence, and angular response were investigated. RESULTS: The SCDD-iv is simple, with no cables linked to the patient and the readout is immediate. The range of response with dose has been tested from 1 up to 12 Gy; the reading is independent of the accumulated dose and dose rate independent in the range between about 0.5 and 5 Gy/min; its temperature dependence is within 0.5% between 25 and 38 °C, and its directional dependence is within 2% from 0° to 90°. The combined relative standard uncertainty of absorbed dose to water measurements is estimated lower than the tolerance and action level of 5%. CONCLUSIONS: The reported results indicate the proposed novel offline dosimeter based on a synthetic single crystal diamond Schottky photodiode as a promising candidate for in vivo dosimetry applications with photon beams.


Asunto(s)
Radiometría/instrumentación , Radioisótopos de Cobalto , Diamante , Diseño de Equipo , Modelos Lineales , Fotones , Radiometría/métodos , Temperatura , Tecnología Inalámbrica/instrumentación
7.
Phys Med ; 31(8): 897-902, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26160702

RESUMEN

PURPOSE: To characterize a synthetic diamond dosimeter (PTW Freiburg microDiamond 60019) in high dose-per-pulse electron beams produced by an Intra Operative Radiation Therapy (IORT) dedicated accelerator. METHODS: The dosimetric properties of the microDiamond were assessed under 6, 8 and 9 MeV electron beams by a NOVAC11 mobile accelerator (Sordina IORT Technologies S.p.A.). The characterization was carried out with dose-per-pulse ranging from 26 to 105 mGy per pulse. The microDiamond performance was compared with an Advanced Markus ionization chamber and a PTW silicon diode E in terms of dose linearity, percentage depth dose (PDD) curves, beam profiles and output factors. RESULTS: A good linearity of the microDiamond response was verified in the dose range from 0.2 Gy to 28 Gy. A sensitivity of 1.29 nC/Gy was measured under IORT electron beams, resulting within 1% with respect to the one obtained in reference condition under (60)Co gamma irradiation. PDD measurements were found in agreement with the ones by the reference dosimeters, with differences in R50 values below 0.3 mm. Profile measurements evidenced a high spatial resolution of the microDiamond, slightly worse than the one of the silicon diode. The penumbra widths measured by the microDiamond resulted approximately 0.5 mm larger than the ones by the Silicon diode. Output factors measured by the microDiamond were found within 2% with those obtained by the Advanced Markus down to 3 cm diameter field sizes. CONCLUSIONS: The microDiamond dosimeter was demonstrated to be suitable for precise dosimetry in IORT applications under high dose-per-pulse conditions.


Asunto(s)
Diamante , Electrones , Radiometría/instrumentación , Radioterapia Asistida por Computador/instrumentación , Aceleración
8.
Med Phys ; 42(4): 2085-93, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25832098

RESUMEN

PURPOSE: To investigate for the first time the dosimetric properties of a new commercial synthetic diamond detector (PTW microDiamond) in high-energy scanned clinical carbon ion beams generated by a synchrotron at the CNAO facility. METHODS: The detector response was evaluated in a water phantom with actively scanned carbon ion beams ranging from 115 to 380 MeV/u (30-250 mm Bragg peak depth in water). Homogeneous square fields of 3 × 3 and 6 × 6 cm(2) were used. Short- and medium-term (2 months) detector response stability, dependence on beam energy as well as ion type (carbon ions and protons), linearity with dose, and directional and dose-rate dependence were investigated. The depth dose curve of a 280 MeV/u carbon ion beam, scanned over a 3 × 3 cm(2) area, was measured with the microDiamond detector and compared to that measured using a PTW Advanced Markus ionization chamber, and also simulated using fluka Monte Carlo code. The detector response in two spread-out-Bragg-peaks (SOBPs), respectively, centered at 9 and 21 cm depths in water and calculated using the treatment planning system (TPS) used at CNAO, was measured. RESULTS: A negligible drift of detector sensitivity within the experimental session was seen, indicating that no detector preirradiation was needed. Short-term response reproducibility around 1% (1 standard deviation) was found. Only 2% maximum variation of microDiamond sensitivity was observed among all the evaluated proton and carbon ion beam energies. The detector response showed a good linear behavior. Detector sensitivity was found to be dose-rate independent, with a variation below 1.3% in the evaluated dose-rate range. A very good agreement between measured and simulated Bragg curves with both microDiamond and Advanced Markus chamber was found, showing a negligible LET dependence of the tested detector. A depth dose curve was also measured by positioning the microDiamond with its main axis oriented orthogonally to the beam direction. A strong distortion in Bragg peak measurement was observed, confirming manufacturer recommendation on avoiding such configuration. Very good results were obtained for SOBP measurements, with a difference below 1% between measured and TPS-calculated doses. The stability of detector sensitivity in the observation period was within the experimental uncertainty. CONCLUSIONS: Dosimetric characterization of a PTW microDiamond detector in high-energy scanned carbon ion beams was performed. The results of the present study showed that this detector is suitable for dosimetry of clinical carbon ion beams, with a negligible LET and dose-rate dependence.


Asunto(s)
Carbono/uso terapéutico , Radioterapia de Intensidad Modulada/instrumentación , Modelos Lineales , Fotones , Dosis de Radiación , Radiometría/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos
9.
Rev Sci Instrum ; 85(12): 123105, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25554270

RESUMEN

Investigations of emission of harmonics from argon gas jet irradiated by 700 fs, 5 mJ pulses from a KrF laser are presented. Harmonics conversion was optimized by varying the experimental geometry and the nozzle size. For the collection of the harmonic radiation silicon and solar-blind diamond semiconductor detectors equipped with charge preamplifiers were applied. The possibility of using a single-crystal CVD diamond detector for separate measurement of the 3rd harmonic in the presence of a strong pumping radiation was explored. Our experiments show that the earlier suggested 0.7% conversion efficiency can really be obtained, but only in the case when phase matching is optimized with an elongated gas target length corresponding to the length of coherence.

10.
Med Phys ; 40(12): 121702, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24320488

RESUMEN

PURPOSE: To investigate the dosimetric properties of a synthetic single crystal diamond Schottky diode for accurate relative dose measurements in large and small field high-energy clinical proton beams. METHODS: The dosimetric properties of a synthetic single crystal diamond detector were assessed by comparison with a reference Markus parallel plate ionization chamber, an Exradin A16 microionization chamber, and Exradin T1a ion chamber. The diamond detector was operated at zero bias voltage at all times. Comparative dose distribution measurements were performed by means of Fractional depth dose curves and lateral beam profiles in clinical proton beams of energies 155 and 250 MeV for a 14 cm square cerrobend aperture and 126 MeV for 3, 2, and 1 cm diameter circular brass collimators. ICRU Report No. 78 recommended beam parameters were used to compare fractional depth dose curves and beam profiles obtained using the diamond detector and the reference ionization chamber. Warm-up∕stability of the detector response and linearity with dose were evaluated in a 250 MeV proton beam and dose rate dependence was evaluated in a 126 MeV proton beam. Stem effect and the azimuthal angle dependence of the diode response were also evaluated. RESULTS: A maximum deviation in diamond detector signal from the average reading of less than 0.5% was found during the warm-up irradiation procedure. The detector response showed a good linear behavior as a function of dose with observed deviations below 0.5% over a dose range from 50 to 500 cGy. The detector response was dose rate independent, with deviations below 0.5% in the investigated dose rates ranging from 85 to 300 cGy∕min. Stem effect and azimuthal angle dependence of the diode signal were within 0.5%. Fractional depth dose curves and lateral beam profiles obtained with the diamond detector were in good agreement with those measured using reference dosimeters. CONCLUSIONS: The observed dosimetric properties of the synthetic single crystal diamond detector indicate that its behavior is proton energy independent and dose rate independent in the investigated energy and dose rate range and it is suitable for accurate relative dosimetric measurements in large as well as in small field high energy clinical proton beams.


Asunto(s)
Diamante , Protones , Radiometría/instrumentación , Estudios de Factibilidad , Modelos Lineales , Dosis de Radiación
11.
Phys Med Biol ; 58(22): 8121-33, 2013 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-24200743

RESUMEN

High-energy electron beams generated by linear accelerators, typically in the range 6 to 20 MeV, are used in small field sizes for radiotherapy of localized superficial tumors. Unshielded silicon diodes (Si-D) are commonly considered suitable detectors for relative dose measurements in small electron fields due to their high spatial resolution. Recently, a novel synthetic single crystal diamond diode (SCDD) showed suitable properties for standard electron beams and small photon beams dosimetry. The aim of the present study is twofold: to characterize 6 to 15 MeV small electron beams shaped by using commercial tubular applicators with 2, 3, 4 and 5 cm diameter and to assess the dosimetric performance under such irradiation conditions of the novel SCDD dosimeter by comparison with commercially available dosimeters, namely a Si-D and a plane­parallel ionization chamber. Percentage depth dose curves, beam profiles and output factors (OFs) were measured. A good agreement among the dosimeters was observed in all of the performed measurements. As for the tubular applicators, two main effects were evidenced: (i) OFs larger than unity were measured for a number of field sizes and energies, with values up to about 1.3, that is an output 30% greater than that obtained at the 10 × 10 cm2 reference field; (ii) for each diameter of the tubular applicator a noticeable increase of the OF values was observed with increasing beam energy, up to about 100% in the case of the smaller applicator. This OF behavior is remarkably different from what typically observed for small blocked fields having the same size and energy as those used in this study. OFs for tubular applicators depend considerably on the field size, so interpolation is unadvisable to predict the linear accelerator output for such applicators whereas reliable high-resolution detectors, as the silicon and diamond diodes used in this work allow OF measurements with uncertainties of about 1%.


Asunto(s)
Diamante , Electrones/uso terapéutico , Aceleradores de Partículas/instrumentación , Radioterapia/instrumentación , Silicio
12.
Med Phys ; 40(2): 021712, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23387735

RESUMEN

PURPOSE: To investigate the dosimetric properties of synthetic single crystal diamond based Schottky diodes under irradiation with therapeutic electron beams from linear accelerators. METHODS: A single crystal diamond detector was fabricated and tested under 6, 8, 10, 12, and 15 MeV electron beams. The detector performances were evaluated using three types of commercial detectors as reference dosimeters: an Advanced Markus plane parallel ionization chamber, a Semiflex cylindrical ionization chamber, and a p-type silicon detector. Preirradiation, linearity with dose, dose rate dependence, output factors, lateral field profiles, and percentage depth dose profiles were investigated and discussed. RESULTS: During preirradiation the diamond detector signal shows a weak decrease within 0.7% with respect to the plateau value and a final signal stability of 0.1% (1σ) is observed after about 5 Gy. A good linear behavior of the detector response as a function of the delivered dose is observed with deviations below ±0.3% in the dose range from 0.02 to 10 Gy. In addition, the detector response is dose rate independent, with deviations below 0.3% in the investigated dose rate range from 0.17 to 5.45 Gy∕min. Percentage depth dose curves obtained from the diamond detector are in good agreement with the ones from the reference dosimeters. Lateral beam profile measurements show an overall good agreement among detectors, taking into account their respective geometrical features. The spatial resolution of solid state detectors is confirmed to be better than that of ionization chambers, being the one from the diamond detector comparable to that of the silicon diode. A good agreement within experimental uncertainties was also found in terms of output factor measurements between the diamond detector and reference dosimeters. CONCLUSIONS: The observed dosimetric properties indicate that the tested diamond detector is a suitable candidate for clinical electron beam dosimetry.


Asunto(s)
Diamante/química , Electrones , Radioterapia/instrumentación , Electrodos , Dosis de Radiación , Radiometría
13.
J Synchrotron Radiat ; 19(Pt 6): 1015-20, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23093764

RESUMEN

A novel beam position monitor, operated at zero bias voltage, based on high-quality chemical-vapor-deposition single-crystal Schottky diamond for use under intense synchrotron X-ray beams was fabricated and tested. The total thickness of the diamond thin-film beam monitor is about 60 µm. The diamond beam monitor was inserted in the B16 beamline of the Diamond Light Source synchrotron in Harwell (UK). The device was characterized under monochromatic high-flux X-ray beams from 6 to 20 keV and a micro-focused 10 keV beam with a spot size of approximately 2 µm × 3 µm square. Time response, linearity and position sensitivity were investigated. Device response uniformity was measured by a raster scan of the diamond surface with the micro-focused beam. Transmissivity and spectral responsivity versus beam energy were also measured, showing excellent performance of the new thin-film single-crystal diamond beam monitor.

14.
Med Phys ; 39(7): 4493-501, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22830781

RESUMEN

PURPOSE: To determine the potentialities of synthetic single crystal diamond Schottky diodes for accurate dose measurements in radiation therapy small photon beams. METHODS: The dosimetric properties of a diamond-based detector were assessed by comparison with a reference microionization chamber. The diamond device was operated at zero bias voltage under irradiation with high-energy radiotherapic photon beams. The stability of the detector response and its dose and dose rate dependence were measured. Different square field sizes ranging from 1 × 1 cm(2) to 10 × 10 cm(2) were used during comparative dose distribution measurements by means of percentage depth dose curves (PDDs), lateral beam profiles, and output factors. The angular and temperature dependence of the diamond detector response were also studied. RESULTS: The detector response shows a deviation from linearity of less than ±0.5% in the 0.01-7 Gy range and dose rate dependence below ±0.5% in the 1-6 Gy∕min range. PDDs and output factors are in good agreement with those measured by the reference ionization chamber within 1%. No angular dependence is observed by rotating the detector along its axis, while ∼3.5% maximum difference is measured by varying the radiation incidence angle in the polar direction. The temperature dependence was investigated as well and a ±0.2% variation of the detector response is found in the 18-40 °C range. CONCLUSIONS: The obtained results indicate the investigated synthetic diamond-based detector as a candidate for small field clinical radiation dosimetry in advanced radiation therapy techniques.


Asunto(s)
Diamante/química , Diamante/efectos de la radiación , Radiometría/instrumentación , Cristalización , Diseño de Equipo , Análisis de Falla de Equipo , Ensayo de Materiales , Fotones/uso terapéutico , Dosis de Radiación , Radiometría/métodos
15.
Appl Radiat Isot ; 67(7-8 Suppl): S183-5, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19375336

RESUMEN

We report on a new solid state dosimeter based on chemical vapor deposition (CVD) single crystal diamond fabricated at Roma "Tor Vergata" University laboratories. The dosimeter has been specifically designed for direct neutron dose measurements in boron neutron capture therapy (BNCT). The response to thermal neutrons of the proposed diamond dosimeter is directly due to (10)B and, therefore, the dosimeter response is directly proportional to the boron absorbed doses in BNCT. Two single crystal diamond detectors are fabricated in a p-type/intrinsic/metal configuration and are sandwiched together with a boron containing layer in between the metallic contacts (see Fig.1). Neutron irradiations were performed at the Frascati Neutron Generator (FNG) using the 2.5 MeV neutrons produced through the D(d,n)(3)He fusion reaction. Thermal neutrons were then produced by slowing down the 2.5 MeV neutrons using a cylindrical polymethylmethacrylate (PMMA) moderator. The diamond dosimeter was placed in the center of the moderator. The products of (10)B(n,alpha)Li nuclear reaction were collected simultaneously giving rise to a single peak. Stable performance, high reproducibility, high efficiency and good linearity were observed.


Asunto(s)
Terapia por Captura de Neutrón de Boro/instrumentación , Neutrones Rápidos/uso terapéutico , Radiometría/instrumentación , Planificación de la Radioterapia Asistida por Computador/instrumentación , Boro/uso terapéutico , Terapia por Captura de Neutrón de Boro/estadística & datos numéricos , Diamante , Diseño de Equipo , Humanos , Isótopos/uso terapéutico , Italia , Neoplasias/radioterapia , Fármacos Sensibilizantes a Radiaciones/uso terapéutico , Radiometría/estadística & datos numéricos , Planificación de la Radioterapia Asistida por Computador/estadística & datos numéricos
16.
Radiat Prot Dosimetry ; 120(1-4): 345-8, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16644955

RESUMEN

Polycrystalline chemical vapour deposited (CVD) diamond film is an interesting material for neutron detection and dosimetry. However, the use of CVD diamond detectors is still limited by the low-level signal pulse produced because of the high energy required to produce an electron-hole pair in diamond (13.2 eV) and by the reduced charge collection efficiency owing to several types of traps for electrons and holes in CVD films. A new type of CVD diamond detector with high gain (HG) contacts was produced as part of the collaboration between the ENEA Fusion Division and the Faculty of Engineering of Rome 'Tor Vergata' University. In this paper the performance of the HG CVD diamond detector is presented and possible applications of CVD diamond detectors to neutron dosimetry are also discussed.


Asunto(s)
Diamante/química , Diamante/efectos de la radiación , Neutrones , Dosimetría Termoluminiscente/instrumentación , Dosimetría Termoluminiscente/métodos , Cristalización , Relación Dosis-Respuesta en la Radiación , Diseño de Equipo , Análisis de Falla de Equipo , Ensayo de Materiales , Dosis de Radiación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
17.
Radiat Prot Dosimetry ; 110(1-4): 233-6, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-15353651

RESUMEN

CVD diamond is an interesting material for radiation detection, its atomic number (Z = 6) is close to that of soft tissues (Z = 7.1) and it can also work in harsh environments. Since many years CVD diamond films have been grown at the Faculty of Engineering, Rome 'Tor Vergata' University, and in 1998 a collaboration with ENEA Fusion Division was established to develop fast neutron monitors to be used in fusion tokamak environment. In this paper the first test of a 120 microm thick polycrystalline CVD diamond detector used for monitoring 14.7 MeV neutrons emission produced with the Frascati Neutron Generator (FNG) is reported. The detector operates in air and in pulse mode. The time irradiation profiles recorded with the CVD diamond detector were compared with those recorded by the standard monitors available at FNG (SSD, fission chamber, NE-213). Good stability and capability to operate in neutron flux up to 1.5 x 10(8) n cm(-2) s(-1) was observed. The radiation hardness property was also investigated using a 460 microm thick film and these results are also reported.


Asunto(s)
Diamante/efectos de la radiación , Análisis de Falla de Equipo/instrumentación , Neutrones Rápidos , Exposición Profesional/análisis , Protección Radiológica/instrumentación , Radiometría/instrumentación , Transductores , Exposición a Riesgos Ambientales/análisis , Diseño de Equipo , Análisis de Falla de Equipo/métodos , Transferencia Lineal de Energía , Dosis de Radiación , Protección Radiológica/métodos , Radioisótopos/análisis , Radiometría/métodos , Reproducibilidad de los Resultados , Dispersión de Radiación , Sensibilidad y Especificidad