Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Chiropr Man Therap ; 29(1): 19, 2021 05 26.
Artículo en Inglés | MEDLINE | ID: mdl-34039379

RESUMEN

BACKGROUND: The Commission of the European Communities (CEC) has published: European Guidelines on Quality Criteria for Diagnostic Radiographic Images. These guidelines are considered a gold standard, recommended for use in quality assurance protocols. The objectives of this study: 1) Propose a graded classification format for Danish chiropractic clinics according to the CEC-quality criteria for diagnostic radiographic images of the lumbar spine. 2) Propose a reporting principle for quality of radiographic images. 3) Document variation in radiation exposure among clinics. METHODS: This is a cross-sectional study of image quality based on random sampling from 148 chiropractic clinics. Clinics were included if using: 1) Digital radiography and 2) The chiropractic picture and archiving system (KirPACS) at the Nordic Institute of Chiropractic and Clinical Biomechanics (NIKKB) in Denmark. A sample of 296 lumbar spine series were randomly collected from KirPACS (January 2018). Two independent observers reviewed 50 lumbar spine series twice with a 4-week interval, testing intra- and inter-observer reproducibility. The same observers then reviewed the remaining 246 radiographic studies. All studies were evaluated using the CEC Quality Criteria. Patient radiation dose values were retrieved from KirPACS (First quarter of 2020). RESULTS: A reporting and classification principle of diagnostic image quality was used in 148 chiropractic clinics. Compliance with the 22 CEC Quality Criteria had proportions ranging from 0.72-0.96 for 18 criteria, while 4 criteria specifying detail and definition ranged between 0.20-0.66. The proposed rating system (A to E) revealed: 18 A clinics, 28 B clinics, 32 C clinics, 25 D clinics and 45 E clinics (A = highest quality; E = lowest quality). The patient radiation reference dose in Denmark is 7 mGy for the AP/PA lumbar spine. Very few clinics exceed the reference dose value, approximately 50% of clinics were below 5 mGy. CONCLUSION: A reporting principle is proposed for a graded classification format based on the CEC-quality criteria for diagnostic radiographic images of the lumbar spine. The Quality Criteria are for the most part met satisfactorily in 148 Danish chiropractic clinics, but important image details are compromised, in most cases, because of low patient radiation doses. The results of a patient radiation dose survey enabled documentation of variation in radiation exposure among chiropractic clinics.


Asunto(s)
Quiropráctica , Adhesión a Directriz , Vértebras Lumbares/diagnóstico por imagen , Radiografía/normas , Estudios Transversales , Dinamarca , Método Doble Ciego , Humanos
2.
Chiropr Man Therap ; 27: 20, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31069046

RESUMEN

Background: The Commission of the European Communities has published guidelines to be used as a gold standard for quality assessment of diagnostic radiographic images. Image quality and radiation dose must be monitored and optimally balanced for diagnostic purposes on patients. The objective of the current study was to assess intra- and inter-observer reproducibility in less experienced observers using the proposed European Guidelines on Quality Criteria for Diagnostic Radiographic Images in a quality assessment of lumbar spine radiographs in primary chiropractic practice in Denmark. Methods: Two observers initially evaluated lumbar spine radiographs randomly selected from fifty chiropractic clinics, all connected to the national PACS server (KirPACS) in Denmark. All evaluations were performed twice by both observers using a four-week interval and for compliance with the European Quality Criteria for Diagnostic Radiographic Images. Inter- and intra-observer reproducibility was calculated using kappa statistics. In the interpretation of the kappa coefficient, the standards for strength of agreement reported by Landis and Koch were followed. Results: The strength of the inter-observer agreement of general image quality at baseline ranged from moderate agreement (k = 0.47) to substantial agreement (k = 0.68). After four weeks, the inter-observer agreement still ranged from moderate agreement (k = 0.59) to substantial agreement (k = 0.71), but with increased agreement for both kappa coefficients. In relation to intra-observer agreement of general image quality, the strength for observer A ranged from moderate (k = 0.58) to substantial (k = 0.72) and the strength for observer B overall was substantial (k = 0.63-0.75). Conclusion: The European Guidelines on Quality Criteria for Diagnostic Radiographic Images are considered a gold-standard and used in a method for quality assurance within the Danish chiropractic profession. The inter-rater and intra-rater agreements in this study, using the CEC-criteria, were found mostly acceptable. With appropriate attention to clear understanding of the individual criteria and sufficient training, this method is found to be reliable, even using less experienced observers, to carry out Diagnostic Radiographic Image Quality-assurance in primary care settings.


Asunto(s)
Quiropráctica/normas , Personal de Salud/normas , Radiografía/normas , Columna Vertebral/diagnóstico por imagen , Dinamarca , Humanos , Variaciones Dependientes del Observador , Guías de Práctica Clínica como Asunto , Radiografía/métodos , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA